The Hoffrichter Trend 300 is a respiration therapy device designed to treat nighttime sleep apnea in patients weighing at least 30 kg. It provides positive airway pressure in two pressure levels and is intended for use with nasal breathing masks equipped with an exhalation port. Features of the Trend 300 include:
- Electronically controlled blower for pressure generation
- Fast control circuit to minimize patient burden
- Pressure control applied directly in the breathing mask
- Respiratory trigger with microcontroller for optimized release criteria
- Dynamic adjustment of release criteria to various sleeping phases
advertisement
▼
Scroll to page 2
of 32
TREND 300 TRE USER`S MANUAL ND 300 Serial Number Each HOFFRICHTER device is provided with a serial number which guarantees the product can be traced back. The serial number is on the type identification plate to be found on the reverse of the device. In case of any query or complaint, please always state the serial number. Conformity 0123 Respiration Therapy Device 2 The device complies with the requirements of the directives 93/42/CEE. TREND 300 Contents Legend of Symbols 04 Safety Instructions 05 Intended Use 08 Technology of TREND 300 09 Hints to be observed before starting 10 Description of the Device 11 Proper Use of the Device 14 Use of Oxygen 16 Cleaning Instruction, Changing of Filter 17 Alarm Functions of TREND 300 18 Functions of TREND 300 19 Trouble Shooting 23 Display Indications 26 Inspection and Check 27 Approved Accessories 28 Technical Data 29 TREND 300 - Patient Pass 30 Respiration Therapy Device TREND 300 3 Legend of Symbols Information on the Type Identification Plate: Pay attention to user´s manual Applied part type BF Protection class II (insulation - enclosed) CE - Conformity Statement Do not dispose of the device with normal domestic waste. For information on the proper disposal of the device, pleasa contact your responsible customer service. Respiration Therapy Device 4 TREND 300 Safety Instructions Before first use of your CPAP-device, please read this manual thoroughly. Keep the manual in a safe place, so that you will be able to consult it whenever necessary. Attention! HOFFRICHTER GmbH shall not be held liable for any damages or consequential damages, consequences for safety, reliability and performance of the device, in case of: Power Supply TREND 300 has a switched mode power pack with a wide power supply range of 100 V~ … 240 V~, 50 ... 60 Hz. This allows connection to power supply lines all over the world. It should be noted that this unit must be connected only to a grounded contact socket outlet. This device is a product of protection class II (protective insulation). The grounding wire of the power cord is internal used as functional earth. DC operation is also possible with 24 V DC, e.g. for mobile use in a truck or caravan. Connect the unit to a DC power source only with the connecting cable supplied. ■ Tampering, modifying, adding expansion features, adjustment, repair and maintenance executed by persons who have not been authorized by us. ■ Building in accessory and spare parts which have been fabricated by other manufactures and not been released by us for use in the respiration therapy device TREND 300 . ■ Using the therapy device in a different way than what has been described in the manual. Respiration Therapy Device TREND 300 5 Safety Instructions Please observe the following points in order to avoid dangerous situations which may occur: 1. Use the device exclusively for your own respiration therapy and only according to what has been directed by your physician. 2. Only use accessory recommended and offered by your authorized dealer. 3. Check the alarm functions of the device at regular intervals (see page 18). 4. Make sure the small opening in the mask or in the connecting piece between mask and tube is always free so that the exhaled air containing CO2 can escape. 5. Never place TREND 300 in a cupboard shelf or under the bed. Make sure the air circulation around the device is not hindered. 6. Keep the unit away from heaters and heated surefaces. Respiration Therapy Device 6 TREND 300 7. In case oxygen is given to you in connection with the respiration therapy make sure that all regulations in view of general and fire safety during dealing with oxygen will be observed. 8. During mobile use, the device is only to switched on in the parked car. 9. You should immediately consult your physician if due to use of the device problems such as dryness of the mucous membranes in nose and pharynx, trouble of the frontal sinus, earache, a runny nose, hypersensitiviy of the skin, irritability, change of mood, disturbance of the sense of direction or memory defects occur. 10. You are requested to contact your authorized dealer immediately, if the device does not function in a proper way. Safety Instructions In order to maintain electric safety please observe the following points: ■ Do not switch on the device if casing or cable are damaged. ■ Do not open the casing of TREND 300. In case of failures always contact your authorized dealer. Stand-by-Operation When the turbine is switched off the unit is in stand-by mode and this is indicated by the illuminated display with date and time. When an air humidifier is connected to the unit, this is in standby mode; the present heater setting is indicated. The power consumption in this operating mode is approx. 3,5 Watts. ■ The device is always to be kept dry. ■ Never use the device in damp rooms or in a bathroom. ■ Never place vessels or glasses filled with liquids on the device. ■ In case the device falls into water, do not touch it. ■ Do not place the device in the near of water-containing vessels (or a bath-tub). ■ Before cleaning the device the AC power plug is always to be pulled out of the socket. By switching off the device with the main switch on the reverse of the device TREND 300 is totally switched off. In this case the internal clock is supplied by a built-in battery. ■ TREND 300 can safely remain in standby operation all the time. NOTE: The memory of the digital trigger may be inaccurate if the mask is put on and taken off repeatedly while the fan is running. If the digital trigger does not change the pressure correctly there after, it is recommended to set back the trigger computer memory. Turning the ventilator off and on once is sufficient. Respiration Therapy Device TREND 300 7 Intended Use Intended Use Contraindications The TREND 300 is for treatment of nighttime sleep apnea in patient weighing at least 30 kg. The respiration therapy may be contraindicated for patients with the following pre-existing medical conditions: This device is not intended for use with ventilatordependent patients. ■ ■ ■ ■ The TREND 300 provides positive airway pressure in two pressure levels. This device is designed to be used with nasal breathing masks equipped with an exhalation port to allow a continuous flow of air through the mask. Do not wear the mask with the device turned off as rebreating of the air occurs. Refer to the manufacturer´s instructions for the mask and exhalation port. Devices equipped with an AquaTREND accessory humidifier provide humidification of the air delivered to the patient. Respiration Therapy Device 8 TREND 300 Bullous lung diseases Pneumothorax Extremely low blood pressure Pneumocephalus or pre-existing CSF leaks or head trauma. Acute sinus or middle ear infection may be an indication to suspend the therapy. Contact your physician if you have questions about this condition. Devices equipped with an AquaTREND accessory humidifier are not intended for use with medications, aromatic oils or other substances added to the humidifier water. Not for use with patients whose supraglottic airways have been bypassed. Technology of TREND 300 TREND 300 is a respiration BILEVEL therapy unit for treatment of nighttime sleep apnea. An air humidifier can be obtained as an accessory. For the pressure generation TREND 300 has an electronically controlled blower. In order to keep the patient's burdening as low as possible the turbine has been equipped with sufficient power reserves as well as a fast control circuit. The pressure control is applied directly in the breathing-mask. So the breathing musculature needs not balance out the flow losses of the breathing air in tube and humidifier. That means the breathing work is made as easy as possible. NOTE: No negative pressure is been generated during exspiration phase. Trigger device The respiratory trigger recognises the patients efforts to breathe in and out and transmits them to a control mechanism. The trigger mechanism of the TREND 300 has its own microcontroller to optimise the release of the trigger by dynamic adjustment of the release criteria to various sleeping phases. In conjunction with optimal flank adjustment the patient experiences a pleasant ventilation which gives him or her the impression that the unit pursues the natural breathing mechanisms without any inertia. TREND 300 has separate air ductings for breathing air and convection air for the electronics. The cold temperature technology applied in the power electronics ensures a low temperature and a long life of the device. For the control of all functions TREND 300 has a built-in microcomputer. The integrated quartz alarm clock increases the comfort during use of the device. The air heats up marginally on passing through the unit and has a higher water uptake capacity. Particularly in winter when the room air is dry the mucous membranes in the mouth and nose can dry out. This is unpleasent and in isolated cases also leads to infections. Air humidification may therefore also be necessary in conjunction with respiration therapy. AquaTREND accessory devices are available which provide humidification. The humidifier simply clicks into position and can be removed by pressing the release button. Refer to the AquaTREND user´s manual or contact your dealer for more information. Respiration Therapy Device TREND 300 9 Hints to be observed before starting Before operating the device, please pay attention to the following: Please pay attention to the following advices for setting up: 1. Never switch on the device if it has recently been in a very cold environment. Wait approximately one hour for temperature compensation. 1. Never place the device near a heater or radiator. Make sure the air circulation especially under and behind the device is not hindered by furniture, curtains or pillows. 2. Check the filter cassette at regular intervals and change it regular (see pages 17, 26). Never use the device without filter cassette. 2. Place the device beside your bed on a firm and even surface such as a nightstand or bedside table. 3. Clean the mask system regularly, and check the accessory especially the therapeutic tube, mask and fixing straps. We recommend to wash the face before going to bed as skin oils and cosmetic should be removed. Thus, the life-span of the mask will be increased and skin irritations can be avoided. 4. Verify that the measuring tube (smaller tube) is correctly attached, open and free of moisture or obstructions. If water enters this tube during cleaning, take special care to remove it. Respiration Therapy Device 10 TREND 300 3. During mobile operation the device is also to be placed on an even and firm surface which should have a border preventing from falling down. Front View Description of the Device Release Button Air Outlet Control Key (Top) for accessories ON/OFF Display HOFFRICHTER TREND 300 Input Key Connectors for AquaTREND (accessory) Measuring Tube Connection Program Keys Respiration Therapy Device TREND 300 11 Back of the Device Description of the Device Air Input Filter Cassette (Top) TREND 300 DC IN 24 V Fernbedienung Remote Control AC Power Plug AC Power Switch Type Identification Plate Respiration Therapy Device 12 TREND 300 DC-Input RS232-Interface Accessory and Spare Parts Description of the Device Cable for Motor Car Measuring Tube Filter Cassette Stoppers Carrier Bag Power Supply Cable Exhalation Port (additional accessory) Breathing-Mask (additional accessory) Therapy Tube (1,80 m) Respiration Therapy Device TREND 300 13 Proper Use of the Device 1. As soon as the device is placed properly please connect it with the power supply cable to an earthing contact socket. 2 3a 2. Switch on the AC power switch on the back of the device. The device welcomes you with a little text in the display. Afterwards the display switches over to indication of current date and time. ON/OF F TREND 300 HOFFRICH DC IN 24 V TER TREND 300 Fernbedienung Remote Control 3. Connect the therapeutic tube a) to the air outlet and b) to the breathing-mask. The device must be used with an exhalation port. 4. Connect the measuring tube to the sensor socket (measuring tube connection). 5. Put on the breathing-mask. If the automatic operating mode has been selected the device will start working upon the first breath. In case of manual operating mode you must press the control key (ON/OFF) for starting the device. 6. Now first TREND 300 starts with the prescribed pressure for the certain period of time you have selected for mask test. During this time you should fit the mask correctly in order to eliminate possible leakages. Respiration Therapy Device 14 TREND 300 3b 4 ON/OFF HO FF RI CH TE R TREND 300 Proper Use of the Device 7.Place the therapy tube in such a way that there is no tension onto the mask when you lay down. 8.Breathe deeply and calmly and only through the nose. If the softstart-function is activated the device will after leakage test automatically reduce the therapeutic pressure first and then gradually increase it until the value prescribed is reached. This enables you to fall asleep while the device is working with a reduced pressure. ON/OFF TREND 300 NOTE: Read in the section "Programming" how the time for softstart and mask test can be adjusted to your individual requirements. Respiration Therapy Device TREND 300 15 Use of Oxygen Please observe the following advices if you must additionally inhale oxygen during the respiration-therapy: If you want to lead the oxygen directly into the breathing-mask please use a non-buckling tube made from material approved for medical applications. Consult your authorized dealer. NOTE: At a fixes flow rate of supplemental oxygen flow, the inhaled oxygen concentration will vary, depending on the pressure settings. Refer to the oxygen suppliers instruction for use. WARNING! Oxygen promotes combustion processes. Observe the valid rules for fire safety during use of oxygen, to reduce the risk of fire. Keep the oxygen instruments free from oils. All sources of ignition including smoking or smoking materials must be kept away from the device and preferably out of the room. Respiration Therapy Device 16 TREND 300 WARNING! If oxygen is used with this therapy device, the oxygen flow must be turned off when the therapy device is not operating. ■ For therapy first switch on turbine and then switch on oxygene. ■ For ending therapy first turn off oxygene then turn off turbine. Please program "Automatic OFF" as described on pages 19 - 22. ■ Before each use, check the proper fit of the tube connections. Cleaning Instructions, Changing of Filter Daily Cleaning of the Breathing-Mask ■ Disconnect the mask and exhalation port from the therapy tube. ■ Clean the breathing mask in accordance with the instructions of the manufacturer of the mask. Weekly cleaning of the device ■ Unplug the AC power cord or switch off the main switch. ■ Clean the device with a cloth moistened with soap water. Afterwards wipe the device dry. Weekly Cleaning of the Therapy Tube ■ Disconnect the tubing from the TREND 300 and the mask and exhalation port. ■ Before cleaning: The measuring tube has to be closed tightly with the stoppers. ■ Use mild soap water and rinse the measuring tube very carefully with clear water. Air-dry the tube very well. ■ After cleaning: Remove the stoppers. Cleaning of the fixing straps (if necessary) ■ Separate the fixing straps from the breathing-mask. ■ Clean the fixing straps in accordance with the instructions of the manufacturer of the straps. A chemical or thermic desinfection of the device or parts of the device by the user is not necessary. Before change of patient the hygienical reprocessing of the device has to be realised by the authorised dealer or manufacturer. Changing the filter ■ If the filter is dirty or the display reads > FI LTER <, the filter cassette must be changed (see pages 26 and 27). Press on the underside of the unit on the filter cassette protrusion and remove the cassette from the top. (see picture) ■ To reset the message please keep the input key pressed while switching on the device. TREND 300 V DC IN 24 Fernbedienung Remote Control Changing the filter cassette Respiration Therapy Device TREND 300 17 Alarm Functions of TREND 300 Power Failure Wake-up Alarm Probably you won't notice a power failure at night-time. As a consequence you would permanently inhale the exhausted air from the therapy tube. Therefore TREND 300 has an alarm mechanism responding if a power failure occurs at night-time or if a fuse becomes defective. In this case an acoustic alarm would wake you up so that you can take off the mask and breathe fresh air. The alarm can be switched off by pressing the control key (ON/OFF). After the end of power failure the turbine of TREND 300 starts again automatically. For higher comfort TREND 300 has an integrated alarm-clock. It can be activated and deactivated with the program keys. The alarm-clock raises alarm at the pre-set wake time. If you press the control key once the alarm will stop for the next five minutes and if you press it twice the alarm will be totally switched off. Mask Alarm This alarm function is active only if the automatic function is switched off. If at night-time the mask slips down or the therapeutic tube is pulled off the device won't switch off automatically but raise an acoustic alarm. This additional safety function, however, requires that the device is switched on and off with the control key (ON/OFF) each morning and evening. Respiration Therapy Device 18 TREND 300 Check of the Power Failure Alarm: Use the device with running turbine and pull out the AC power plug or switch off the AC power switch. Now the acoustic alarm should be occur. Check every month if the acoustic signal lasts long enough (guide value 1 min). After pressing the control key or switching on the power supply the acoustic signal will stop. Check of the Mask Alarm: Use the device with running turbine and switch off automatic function. Do not fix the mask to the face. After 10 seconds an acoustic signal will occur. Functions of TREND 300 For programming the functions of TREND 300 three keys are available: = Input key = Program key = Program key By holding the INPUT key pressed, you reach the input mode after 1 second, and then you see the menu of TREND 300 in the display. The following 2 different kinds of menu can be activated: Standard-Menu Hints for (1) to (4): The display first indicates the menu line (1). After adjustment of I-Pressure the lines (2) to (4) will be indicated step by step and can be set by the doctor. Complete-Menu WAKE TIME ........04:45 WAKE TIME .......04:45 TIME ........................ 16:24 TIME ..........................16:24 DATE ................. DATE ....................12.11.02 12.11.02 EXIT MENU Example: Setting alarm clock Press key for 1 second. Display indicates: RAMP................0s/0min WAKE TIME.......... 04:45 AUTOMATIC...........OFF (1) NOTE: If you prefer instead of the standard-menu the complete-menu (or reverse) contact your dealer please. The display always shows two lines. With the keys and you can choose which lines are to be indicated. A triangle symbol in front of a line means that this line has been chosen. I-SET.......... ......12,0hPa EXIT MENU! (PIN-protected) (2) E-SET. . . . . . . 8,0hPa (PIN-protected) (3) I-SLOPE.......... 0,5s (PIN-protected) (4) E-SLOPE........0,5s (PIN-protected) TRIGGER ................ 3 MODE............BILEV-S BRIGHTNESS ...100% After pressing key again the hour of the alarm time is flashing and can be changed by the keys and . Press key again for changing alarm minute according to same procedure. To come back to the menu press the key again. For leaving the menu select point " E X I T M E N U !" : OPERATION......01937h EXIT MENU! Respiration Therapy Device TREND 300 19 Functions of TREND 300 WAKE TIME.......... 06:00 All functions are programmed in the same way: EXIT MENU! Press for 1 s, and choose the line requested with the keys and : Press Input key to leave the programming mode. During standard operation the display indicates date and time: SA 28.FEB 12:42 The alarm clock can be activated or deactivated by the keys and . With the key the alarm clock can be switched on. For controlling the programmed alarm time is indicated for a short time in the display. After this a bell symbol shows that the alarm clock is active. SA 28.FEB 12:42 With the key the alarm clock can be switched off (e.g. on Sunday). In this case the bell symbol is not indicated. NOTE: If there is no key pressed during programming for 30 seconds the programming mode will be left automatically. Respiration Therapy Device 20 TREND 300 By pressing the key the following options can be chosen: WAKE TIME WAKE HOUR, WAKE MINUTE TIME HOUR, MINUTE DATE YEAR, MONTH, DAY, WEEKDAY RAMP 1. mask test time: 2. softstart time: AUTOMATIC ON, OFF I-SET 1. PIN INPUT! 0...90 s (in 5 s-steps) 0 . . . 6 0 m i n (in 1 min-steps) following selection after: 2 . 3 , 0 . . . 1 8 , 0 h P a (in 0,5 hPa-steps) E-SET 3 , 0 . . . 1 8 , 0 h P a (in 0,5 hPa-steps) I-SLOPE 0,0 ... 1,5 s (in 0,1 s-steps) E-SLOPE 0,0 ... 1,5 s (in 0,1 s-steps) TRIGGER MODE 1 ... 5 BILEV-S BRIGHTNESS 100%, 50% COUNTER POWER, BLOWER, FILTER, THERAPY (time indicate in h) (only indicate, not selection possibility) EXIT MENU! If you want to finish the programming, choose the menu line “EXIT MENU!” and press key . Functions of TREND 300 Date, Time Date and time of the internal clock can be adjusted. The internal clock has a built-in battery with reserve power for 8 years without mains connection. You can adjust the weekdays (Mo thru Su), day (1 till 31), month (1 till 12), year (00 till 99), hour (00 till 24) and minute (00 till 59). The clock serves for indicating the right date, for the right function of the alarm-clock and for the exact recording of current events. Ramp After each turbine start the computer of TREND 300 checks whether a softstart-ramp has been programmed. During the time which you have preset the softstart function slowly raises the pressure from 3 hPa (mbar) up to the pressure prescribed by your physician. This should ease your falling asleep. Before starting softstart TREND 300 checks the proper fitting of the mask using the full pressure for the selected time. Especially if you feel you have not yet got used to the respiration-therapy the softstart can give you relief. The delay time of TREND 300 can be adjusted between zero (in this case the therapeutic pressure prescribed is instantly given) and 60 minutes (the therapeutic pressure prescribed is built-up within 60 min). be programmed. This mask test runs under full therapy pressure before starting ramp and checks whether there is a leakage. pressure in hPa 10 pressure prescribed: 10 hPa (mbar) The pressure is gradually increased up to the therapeutic pressure mask test Softstart time programmed in min 0-90 s 3 time in min 0 15 30 45 60 To ensure that there is no mask leakage even during the high therapy pressure a mask test time up to 90 s can Respiration Therapy Device TREND 300 21 Functions of TREND 300 Automatic Operation In case of automatic operation you have only to put on the mask. As soon as you breathe the turbine of TREND 300 will be switched on. If you take off the mask the turbine will be switched off automatically after a delay time of 5 seconds. During automatic operation the device also will be switched off if mask or tube drop off unnoticed at night-time. That is why TREND 300 optionally offers the function "Automatic OFF" with mask-alarm. If you choose this function you must press the CONTROL key (ON/OFF) for switching on the device each evening and switching off each morning. In this case you get an acoustic alarm if the mask drops off at nighttime. Pressure (I-Set, E-Set, I-Slope, E-Slope) The adjustment of the desired pressures and slopes is done by the physician who has a special remote control. Without remote control, however, it is also possible to change the pressure adjustment of the device provided that a respective PIN has been programmed. The PIN will enable the service company to do the respective work if necessary. Please, never try to "crack" the PIN. You should better talk to your physician in case of any doubt about the pressure prescribed. Respiration Therapy Device 22 TREND 300 Trigger The trigger sensitivity is adjustable in 5 steps. Example: TRIGGER .... 1 (lowest trigger threshold = highest trigger sensitivity) TRIGGER .... 3 (medium trigger threshold * factory adjustment) TRIGGER .... 5 (highest trigger threshold = lowest trigger sensitivity) NOTE: The adjustment of the trigger sensitivity should ever be made by your physician. Brightness You can adjust the brightness of the display to suit your needs by selecting between two stages: ■ 100% = maximum brightness, the display is easily legible also in brightly lit rooms. ■ 50% = minimum brightness, the display is easily legible in slightly darkened rooms. In the event of an alarm, the display always switches automatically to 100% brightness for the duration of the alarm. Power Under this point you find the running time of the turbine, the operation time of the filter, the total operation time including stand-by operation and the therapy time of TREND 300. Trouble Shooting PROBLEM POSSIBLE CAUSE HELP Pain in nose, nasal cavity or ears Inflammation Stop therapy and contact your doctor Unpleasant feeling of too high pressure Problem with prescribed high pressure Contact your doctor You are not yet used to the respiration-therapy Relax and use softstart function Dryness and irritation of nose and throat Dry treatment air Consult your doctor about prescribing the addition of AquaTREND humidifier Symptoms of sleep apneas appear again Your personal life conditions have changed Contact your doctor Devise is not operating properly Check device by an authorized company Respiration Therapy Device TREND 300 23 Trouble Shooting PROBLEM POSSIBLE CAUSE HELP Irriteted or dry eyes Leakage between mask and skin Check correct position of mask New mask if defective Wet nose Reaction to the air flow Contact your doctor about use of a humidifier Head cold, sinus drainage or discomfort Normal cold or sinus infection Stop use if your condition interferes with treatment, contact your doctor Cold nose Low room temperature Increase room temperature Warm up tube under your pillow Inflammation of the skin under the mask Wrong mask size Contact your doctor Fixing straps too short Relax the straps Allergic reaction Contact your doctor Respiration Therapy Device 24 TREND 300 Trouble Shooting PROBLEM POSSIBLE CAUSE Air too warm Dirty filter Exchange filter Air input is blocked Make sure air input is clear Heating too close to TREND 300 Check position of TREND 300 Device is defective Ask your authorized dealer Water in measuring tube Make sure air input is clear Softstart function is active Decrease softstart time Air input is blocked Make sure air input is clear Measuring tube is disconnected or blocked Check measuring tube Leakage in device Ask your authorized dealer Water in measuring tube Dry measuring tube Water in measuring tube Dry measuring tube Device is defective Contact service company No air flow Low air flow Turbine works always with maximum speed Therapy pressure is not constant HELP Respiration Therapy Device TREND 300 25 Display Indications In the following table the most important display indications are shown. The sense off all other indications can be taken from context. MASK TEST. . .55s You still have 55 s for fitting the mask correctly. After that time the softstart function starts. SOFTSTART 10:33 You still have 10 min and 33 s until the full therapeutic pressure is reached. CHECK BREATHING MASK The mask has dropped down from your face or you haven't put it on during "Automatic OFF" and running turbine. ALARM-CLOCK ON In normal operation you have pressed the key and got the message that you will be woken up at a quater to six o'clock. ALARM-CLOCK OFF In normal operation you have pressed the key and got the message that the alarm-clock has been switched off right now. WAKE ALARM Wake alarm has been triggered. Press the control key once in order to start the slumber. If you press the main key for the second time during the slumber phase the alarm is finally switched off. SLUMBER. . . 1:18 You still have 1 min and 18 s until the alarm-clock is ringing again. WAKE ALARM OFF You have pressed the control key and finished the slumber phase. > FILTER < You are required to exchange the filter cassette (see page 17). If switching on the device after filter exchange please keep the input key pressed in order to reset the message. > SERVICE < TREND 300 needs a security check. Please inform your after-sales service as only the authorized service people can reset this message. The device can be used furtheron. PUT ON MASK! You are required to put on the mask and to breathe through the nose. TAKE OFF MASK! During activated automatic one has tried to switch off the device by hand. Please take off the mask. The device switches off the therapeutic pressure after a few seconds. BAT: 24,6 V Voltage on board of a vehicle (if battery operation) POWER FAILURE After the end of power failure the turbine of TREND 300 restarts automatically. RESTART TURBINE Respiration Therapy Device 26 TREND 300 Inspection and Check Although all parts of TREND 300 are proved to have a long life the device should be examined from time to time. A device check is necessary if the message " S E R V I C E !" appears in the display. In this case we urgently recommend you to have the device examined and maintained by the authorized after-sales service because only these people have the necessary tools and measuring devices. Also in case of the " S E R V I C E !" display, the device can be used furtheron. Please pay attention to the following check-list: ■ weekly check of the alarm function "Power failure" (see page 18) ■ weekly check of "Mask Alarm" (see page 18) ■ check of the filter cassette and if necessary replacement by a new one Attention! The display message " S E R V I C E !" cannot be removed if the maintenance is executed by an unauthorized workshop. For a long lifetime of your TREND 300 device note the following points: 1. Please follow the cleaning instruction on the page 17. 2. Check the system at regular intervals. Respiration Therapy Device TREND 300 27 Approved Accessories Specification HOFFRICHTER Order-No. Filter Cassette AC Power Supply Cable Therapy Tube Stoppers 00007870 31100001 00007116 44000012 (for closing measuring tube during tube cleaning) Carrier Bag User´s Manual Cable for motor car 00007860 00007877 00009212 Plug-In-Humidifier AquaTREND III-H0 AquaTREND III-H1 AquaTREND III-H5 00007992 00007993 00007990 NOTE: The TREND 300 should be used only with therapy tubes provided by the manufactuer. Respiration Therapy Device 28 TREND 300 Concerning available approved therapy masks and additional accessories please contact your authorized dealer. Technical Data Dimensions (B X T X H) 230 x 225 x 110 mm Mass ca. 2,5 kg Power supply 100 V~ … 240 V~, 50 ... 60 Hz 24 V DC Pressure range IPAP, EPAP: 3 … 18 hPa (mbar) in steps of 0,5 hPa Power consumption without humidifier 22 W (average value) Power consumption of stand-by <5W Pressure variance < ± 0,08 hPa (mbar) at 10 hPa according to DIN EN ISO 17510 Inner resistance Noise level without mask < 0,12 hPa s/l < 27 dB(A) at 10 hPa (mbar) according to DIN EN ISO 17510 Constant display pressure value, bargraph, date, time, alarm clock state Operating Altitude - 400 m ... 3500 m above sea level Operating Temperature 5 °C ... 40 °C Storage Temperature - 40 °C ... 70 °C CE-mark according to the EC-directives 93/42/ECC, concerning medical devices, class IIa Data subject to technical alteration Respiration Therapy Device TREND 300 29 TREND 300 - patient pass name serial-No. software-version first name type of mask mask size street Therapy process postal zip code/place date telephon weight high birth. on health insurance company blood pressure apnea index medicine IPAP-Set hospital-stamp EPAP-Set I-Slope E-Slope family doctor-stamp therapy standing next service executed customer service-stamp Respiration Therapy Device 30 TREND 300 Notes Respiration Therapy Device TREND 300 31 MANUFACTURER: SALES & SERVICE: HOFFRICHTER GmbH Mettenheimer Straße 12/14 19061 Schwerin, Germany Tel.: +49-385-39925-0 Fax: +49-385-39925-25 Mail: [email protected] URL: www.hoffrichter.de HOFFRICHTER type names: TREND 110 Monolevel Typ 5CP 102 TREND 210 Monolevel Typ 5CP 210 TREND 300 Bilevel Typ 5CP 301 TREND 400 Bilevel ST20 Typ 5CP 401 TREND 500 Bilevel ST33 Typ 5CP 501 AutoTREND Auto CPAP Typ 5CP 253 AquaTREND III-H0 humidifier Typ 5CP 931 AquaTREND III-H1 humidifier Typ 5CP 941 AquaTREND III-H5 humidifier Typ 5CP 961 TREND 300-eng-1208-06
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project