Tripp Lite SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial Datasheet


Add to my manuals
5 Pages

advertisement

Tripp Lite SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial Datasheet | Manualzz

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine

Wave UPS, Extended Run, SNMP, Webcard, 3U

Rack/Tower, USB, DB9 Serial

MODEL NUMBER: SMX5000XLRT3U

Highlights

5kVA / 5000VA line interactive

3U rack/tower UPS; Sine wave output

230V nominal output during brownouts to 170V and overvoltages to 282V

USB, Serial, EPO & optional

SNMP/Web card monitoring options

3U all-in-one chassis; 98% efficiency

Hardwire input; 8 C13 & 3 C19 outlets

Package Includes

SMX5000XLRT3U UPS system

PowerAlert Software and Cabling

Mounting hardware for 4 post

Description

5000VA line interactive UPS system for server, network and telecommunications equipment. 5kVA UPS with rackmount installation

Warranty information

Instruction manual internal batteries installs in only 3 rack spaces with a depth of only 635mm / 25 inches. High 98% line-power efficiency rating reduces energy consumption and BTU heat output. Expandable battery runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U

(multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs. Uninterruptible Power Supply (UPS) switches to battery-derived AC output during power failures and extreme voltage variations. Line interactive Automatic Voltage Regulation (AVR) offers voltage boost during brownouts and voltage reduction during overvoltage conditions to maintain regulated 230v output over an input range of 170-282V. Supports hardwire input. Includes C19 and

C13 output receptacles. Network-grade AC surge and noise suppression. Network management interfaces support communications via USB, DB9 serial and

SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces at once. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. 3-stage metered current monitoring and battery charge status LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rackmount installation accessories included;

2-9USTAND tower kit and 2POSTRMKITWM two post rack mounting accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs.

Features

5000VA/3750 watt max. output power capacity compatible with International 230V input voltage

3U rack/tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 635mm / 25in

Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges

Line Interactive Automatic Voltage Regulation (AVR) corrects 230V nominal input from 170 to 282VAC to usable 230V levels without consuming battery power

AVR circuits boost undervoltages from 170 to 199V by 12% and reduce overvoltages from 245 to 282V by 12%

Network interfaces support simultaneous communications via USB, DB9 serial or contact closure and SNMPWEBCARD slot

Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP

Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery

1 / 5

capacity, internal UPS temperature, AC line frequency, timed inverter shutoff and activate self-test

Built-in Emergency Power Off (EPO) interface with cable

Sine wave output in AC and battery mode

Expandable runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs

Half/full load runtime of 27/10 minutes with internal batteries

Includes 11 output receptacles (3 C19/8 C13)

Hardwire input AC connection

3 stage metered LEDs offer current monitoring and battery charge level

Mains power and voltage regulation LEDs offer at-a-glance power status information

Front panel switches support self-test and alarm cancel functions

Included adjustable mounting rails support installation in 4 post 19 inch racks

Supports 2 post rackmount installation with optional 2POSTRMKIT accessory

Supports upright tower placement with optional 2-9USTAND accessory

CE, GOST, SASO listed

Specifications

General Info

RoHS Y

OUTPUT

Output Volt Amp Capacity (VA)

Output kVA Capacity (kVA)

Output Watt Capacity (Watts)

Output kW Capacity (kW)

Power Factor

Nominal Output Voltage(s)

Supported

5000

5

3750

3.75

0.75

220V; 230V; 240V

Nominal Voltage Details

Frequency Compatibility

Output Voltage Regulation (Line

Mode)

Output Voltage Regulation (Battery

Mode)

230v nominal inverter output voltage

50 / 60 Hz

-17%, +8%

+/- 5%

Output Receptacles

Included Output Power Cables

Output Circuit Breakers

Output AC Waveform (AC Mode)

(8) C13; (3) C19

Includes 3 C13 to C14 output power cables

15A (x3) breaker supports 1 C19 outlet each, 10A (x2) breaker supports 4 C13 outlets each

Sine wave

Output AC Waveform (Battery Mode) Pure Sine wave

2 / 5

INPUT

Rated input current (Maximum Load) 27A

Nominal Input Voltage(s) Supported 230V AC

UPS Input Connection Type Hardwire

UPS Input Connection Description

Input Phase

Hardwire input supports International 230V input (L, N, PE)

Single-Phase

BATTERY

Full Load Runtime (min.)

Half Load Runtime (min.)

Expandable Battery Runtime

External Battery Pack Compatibility

DC System Voltage (VDC)

Battery Recharge Rate (Included

Batteries)

Internal UPS Replacement Battery

Cartridge

Battery Access

Battery Replacement Description

8.5 min. (3750w)

20 min. (1875w)

Extended runtime supported via optional external battery packs

BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)

48

Less than 4 hours from 10% to 90% (typical, full load discharge)

RBC94-3U (quantity 3)

Front panel battery access door

Hot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage Regulation Description

Overvoltage Correction

Undervoltage Correction

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 170 to 282

Input voltages between 245 and 282 are reduced by 12%

Input voltages between 170 and 199 are boosted by 12%

USER INTERFACE, ALERTS & CONTROLS

Switches 2 Switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status

Audible Alarm

LED Indicators

Audible alarm indicates power-failure, overload and low-battery conditions

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

UPS AC Suppression Response

Time

EMI / RFI AC Noise Suppression

480

Instantaneous

Yes

3 / 5

PHYSICAL

Installation Form Factors Supported with Included Accessories

Installation Form Factors Supported with Optional Accessories

Primary Form Factor

UPS Power Module Dimensions

(hwd, in.)

UPS Power Module Dimensions

(hwd, cm)

Installed Whole System Maximum

Rack Depth (in.)

Installed Whole System Maximum

Rack Depth (cm)

4 post 19 inch rackmount

2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)

Rackmount

5.2 x 17.5 x 25

13.3 x 44.4 x 63.5

25

63.5

Rack Height (U Spaces)

UPS Power Module Weight (lbs.)

3

143

UPS Power Module Weight (kg) 64.9

UPS Shipping Dimensions (hwd / in.) 11.3 x 23 x 31.5

UPS Shipping Dimensions (hwd / cm)

28.6 x 58.4 x 80

Shipping Weight (lbs.)

Shipping Weight (kg)

Cooling Method

UPS Housing Material

182

82.6

Fans

Steel

ENVIRONMENTAL

Operating Temperature Range

Storage Temperature Range

Relative Humidity

AC Mode BTU / Hr. (Full Load)

AC Mode Efficiency Rating (100%

Load)

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

0 to 95%, non-condensing

271

98%

COMMUNICATIONS

Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions

PowerAlert Software

Communications Cable

WatchDog Compatibility

Included

USB and DB9 cabling included

Supports Watchdog application, OS and hard-reboot restart options for remote applications

4 / 5

LINE / BATTERY TRANSFER

Transfer Time

Low Voltage Transfer to Battery

Power (Setpoint)

High Voltage Transfer to Battery

Power (Setpoint)

7 ms (AC to Battery); 1 ms (Battery to AC) typical

170

282

SPECIAL FEATURES

Grounding Lug

Cold Start (Startup in Battery Mode

During a Power Failure)

High Availability UPS Features

Green Energy-Saving Features

Back panel grounding lug

Cold-start operation supported

Hot swappable batteries

Greater than 95% efficiency - GREEN UPS

CERTIFICATIONS

UPS Certifications

UPS Certification Details

CE

Class A (EMI)

WARRANTY

Product Warranty Period

(International)

Product Warranty Period (Mexico)

Product Warranty Period (Puerto

Rico)

2-year limited warranty

2-year limited warranty

2-year limited warranty

© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

5 / 5

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • 5kVA / 5000VA line interactive 3U rack/tower UPS; Sine wave output
  • 230V nominal output during brownouts to 170V and overvoltages to 282V
  • Add optional WEBCARDLX with latest version of PADM20 for enhanced remote management
  • 3U all-in-one chassis; 98% efficiency
  • Hardwire input; 8 C13 & 3 C19 outlets

Related manuals

advertisement