Tripp Lite SMX5000XLRT3U is a 5kVA line interactive UPS with a sine wave output, designed for server, network, and telecommunications equipment. It offers protection against blackouts, voltage fluctuations, and transient surges. With an expandable battery runtime, it provides power backup during outages, ensuring seamless operation of critical devices. Its LED indicators and audible alarms keep you informed about power status and battery conditions. The USB, serial, and EPO interfaces enable remote monitoring and control.
advertisement
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: [email protected]
Model Number: SMX5000XLRT3U
SmartPro 5kVA Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 3U Rack/Tower,
USB, Serial, EPO, 230V
Highlights
5kVA / 5000VA line interactive 3U rack/tower UPS; Sine wave output
230V nominal output during brownouts to 170V and overvoltages to 282V
USB, Serial, EPO & optional SNMP/Web card monitoring options
3U all-in-one chassis; 98% efficiency
Hardwire input; 8 C13 & 3 C19 outlets
Description
5000VA line interactive UPS system for server, network and telecommunications equipment. 5kVA UPS with internal batteries installs in only 3 rack spaces with a depth of only 635mm / 25 inches. High 98% line-power efficiency rating reduces energy consumption and BTU heat output.
Expandable battery runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs. Uninterruptible Power Supply (UPS) switches to battery-derived AC output during power failures and extreme voltage variations. Line interactive Automatic Voltage Regulation (AVR) offers voltage boost during brownouts and voltage reduction during overvoltage conditions to maintain regulated 230v output over an input range of 170-282V. Supports hardwire input. Includes C19 and C13 output receptacles.
Network-grade AC surge and noise suppression. Network management interfaces support communications via USB, DB9 serial and
SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces at once. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. 3-stage metered current monitoring and battery charge status LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rackmount installation accessories included; 2-9USTAND tower kit and 2POSTRMKITWM two post rack mounting accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs.
Package Includes
SMX5000XLRT3U UPS system
PowerAlert Software and Cabling
Mounting hardware for 4 post rackmount installation
Warranty information
Instruction manual
Features
5000VA/3750 watt max. output power capacity compatible with International 230V input voltage
3U rack/tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 635mm / 25in
Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges
Line Interactive Automatic Voltage Regulation (AVR) corrects 230V nominal input from 170 to 282VAC to usable 230V levels without consuming battery power
AVR circuits boost undervoltages from 170 to 199V by 12% and reduce overvoltages from 245 to 282V by 12%
Network interfaces support simultaneous communications via USB, DB9 serial or contact closure and SNMPWEBCARD slot
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff and activate self-test
Built-in Emergency Power Off (EPO) interface with cable
Sine wave output in AC and battery mode
Expandable runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs
Half/full load runtime of 27/10 minutes with internal batteries
Includes 11 output receptacles (3 C19/8 C13)
Hardwire input AC connection
3 stage metered LEDs offer current monitoring and battery charge level
Mains power and voltage regulation LEDs offer at-a-glance power status information
Front panel switches support self-test and alarm cancel functions
Included adjustable mounting rails support installation in 4 post 19 inch racks
Supports 2 post rackmount installation with optional 2POSTRMKIT accessory
Supports upright tower placement with optional 2-9USTAND accessory
CE, GOST, SASO listed
Specifications
OUTPUT
Output Volt Amp Capacity
(VA)
Output kVA capacity (kVA)
Output Watt Capacity
(watts)
Output kW capacity
Output power factor
Nominal Output Voltage(s)
Supported
Nominal Voltage details
Frequency compatibility
Output voltage regulation
(line mode)
Output voltage regulation
(Battery mode)
Built-in UPS output receptacles
Included output power cables
Output circuit breaker
Output AC waveform (AC mode)
Output AC waveform
(battery mode)
INPUT
Rated input current (at maximum load)
Nominal Input Voltage(s)
Supported
UPS input connection type
Phase
5000
5
3750
3.75
0.75
220V; 230V; 240V
230v nominal inverter output voltage
50 / 60 Hz
-17%, +8%
+/- 5%
8 C13 outlet(s); 3 C19 outlet(s)
Includes 3 C13 to C14 output power cables
15A (x3) breaker supports 1 C19 outlet each, 10A (x2) breaker supports 4 C13 outlets each
Sine wave
Pure Sine wave
27A
230V AC
Hardwire
Single-Phase
BATTERY
Full load runtime (minutes)
External battery pack compatibility
8.5 min. (3750w)
Half load runtime (minutes) 20 min. (1875w)
Expandable battery runtime Extended runtime supported via optional external battery packs
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery cartridge (internal UPS battery replacement)
48
Less than 4 hours from 10% to 90%
RBC94-3U (quantity 3)
Battery Access
Battery replacement description
VOLTAGE REGULATION
Voltage regulation description
Front panel battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 170 to 282
Overvoltage correction Input voltages between 245 and 282 are reduced by 12%
Undervoltage correction
LEDS ALARMS & SWITCHES
Input voltages between 170 and 199 are boosted by 12%
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms
Alarm cancel operation
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Switches
SURGE / NOISE SUPPRESSION
2 Switches control off/on power status and alarm-cancel/self-test operation
UPS AC suppression joule rating
480
UPS AC suppression response time
Instantaneous
Yes EMI / RFI AC noise suppression
PHYSICAL
Installation form factors supported with optional accessories
Primary form factor
2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Rackmount
5.2 x 17.5 x 25 UPS / Power Module dimensions in primary form factor (height x width x depth / inches)
UPS / Power Module dimensions in primary form factor (height x width x depth / cm)
13.3 x 44.4 x 63.5
Rack Height
Secondary form factor
UPS / Power Module weight
(lbs)
UPS / Power Module weight
(kg)
3U
Tower (requires
143
64.9
UPS Shipping dimensions
(height x width x depth / inches)
11.3 x 23 x 31.5
UPS Shipping dimensions
(height x width x depth / cm)
28.6 x 58.4 x 80
Shipping weight (lbs) 182
2-9USTAND )
Shipping weight (kg)
Cooling method
UPS housing material
ENVIRONMENTAL
Operating Temperature
Range
82.6
Fans
Steel
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
271 AC mode BTU / hr. (full load)
AC mode efficiency rating
(100% load)
COMMUNICATIONS
Communications interface
Network monitoring port description
98%
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Supports detailed monitoring of UPS and site power conditions
PowerAlert software
Communications cable
Included
USB and DB9 cabling included
WatchDog compatibility
LINE / BATTERY TRANSFER
Transfer time
Supports Watchdog application, OS and hard-reboot restart options for remote applications
2-4 milliseconds
170 Low voltage transfer to battery power (setpoint)
High voltage transfer to battery power (setpoint)
SPECIAL FEATURES
Grounding lug
Cold Start (startup in battery mode during a power failure)
282
Back panel grounding lug
Cold-start operation supported
High availability UPS features
Green & high efficiency features
CERTIFICATIONS
UPS Certifications
UPS Certification details
WARRANTY
Product Warranty Period
(International)
Product Warranty Period
(Mexico)
Product Warranty Period
(Puerto Rico)
Hot swappable batteries
Greater than 95% efficiency - GREEN UPS
CE
Class A (EMI)
2-year limited warranty
2-year limited warranty
2-year limited warranty
Related Items
Optional Products
Related Model
SNMPWEBCARD
ENVIROSENSE
SRSWITCH
BP48V27-2US
BP48V24-2U
BP48V60RT-3U
PDU12IEC
2-9USTAND
MODBUSCARD
2POSTRMKITHD
Description
For remote monitoring and control via SNMP, Web, or Telnet.
Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD or switched PDU.)
Magnetic Door Switch Kit for front and rear doors; requires ENVIROSENSE
BP48V27-2US - 2U External 48V Rack/Tower Battery pack for select Tripp Lite UPS
Systems
BP48V24-2U - 2U External 48V Rack/Tower Battery Pack for select Tripp Lite UPS
Systems
External Battery Pack and Cable. 3U, Expandable, Blue 2-Point Connector
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical networking equipment
Enables Tower Placement of Rackmount UPS Systems
For remote monitoring and control via MODBUS protocol
Enables 2-Post Rackmount Installation of 3U and Larger UPS, Transformer and Battery
Pack Components
More information, including related products, owner's manuals, and additional technical specifications, can be found online at http://www.tripplite.com/sku/SMX5000XLRT3U .
Copyright © 2014 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.
1
1
1
1
1
1
Qty.
1
1
1
1
advertisement
Key Features
- 5kVA / 5000VA line interactive 3U rack/tower UPS; Sine wave output
- 230V nominal output during brownouts to 170V and overvoltages to 282V
- Add optional WEBCARDLX with latest version of PADM20 for enhanced remote management
- 3U all-in-one chassis; 98% efficiency
- Hardwire input; 8 C13 & 3 C19 outlets
Related manuals
advertisement