Bosch D9124 is an addressable fire alarm control panel designed for complex alarm systems in various settings like schools, hospitals, and manufacturing plants. It offers features such as alarm verification to reduce false alarms, auxiliary and standby power for continuous operation, and central station communication for remote monitoring. With its modular design and a range of compatible products, the D9124 provides flexibility and scalability for different applications.
advertisement
Fire Alarm Systems | D9124 Addressable Fire Alarm Control Panel (FACP)
D9124 Addressable Fire Alarm Control
Panel (FACP)
▶ 24 VDC, 4 A power for initiation circuits and NACs;
12 VDC, 1.4 A power for system accessories
▶ Up to eight supervised or 32 unsupervised remote annunciators
▶ One-man Fire Test Mode
▶ Schedules (Skeds function) service reminder for local systems
▶ Low battery, AC power supply, and battery lead supervision
▶ Dual phone line monitor
The D9124 FACP controls complex alarm systems used in schools, universities, manufacturing plants, and health care facilities. Program it for fire, fire supervisory, intrusion, or access control applications. Program it locally using the
D5200CE hand-held programmer or remotely using RPS over telephone lines or local-area or wide-area networks
(LAN or WAN).
The D9124 FACP is a modular assembly, installed in a red steel enclosure, which can be surface- or flush-mounted.
The enclosure has keyed controller access making it suitable for installation in public access areas.
Functions
Alarm Verification
The alarm verification feature reduces potential false alarms by requiring a reset and a second alarm signal from the device before the control panel raises an alarm condition.
Auxiliary and Standby Power
The 4 A, 24 VDC power supply charges the standby batteries and powers auxiliary devices. The power supply responds to low battery or battery disconnect conditions with a
Trouble LED and a Trouble Relay for sounders or lights.
Five system power trouble conditions are selected by DIP switches. They can be individually linked to a central station, or grouped to activate a trouble relay, allowing a single supervised address to monitor the power supply.
A pair of 12 V batteries provides standby power. Two additional batteries provide standby power for initiating devices and notification appliances. All four batteries are housed within the panel enclosure.
Note Batteries are not included in the D9124 and must be purchased separately.
Central Station Communication
Events can be communicated to a central station by the digital communicator or by adding an optional Ethernet interface module. The optional Bosch D6500 or D6600
NetCom Receiver and Modem IIIa 2 reporting format provide individual point reporting to monitoring facilities.
The D5500 Remote Programming Software (RPS) allows the following to be controlled from a central station:
• Resetting notification appliances
Activating or deactivating remote annunciation
•
Activating or deactivating relays
Supervising battery condition
• Setting point status and armed status
Enabling or disabling reporting functions
•
Shunting reporting points during servicing
www.boschsecurity.com
2 | D9124 Addressable Fire Alarm Control Panel (FACP)
Event Log Storage, Viewing, and Printing
The D9124's memory log stores time, date, point, and user
ID for up to 1000 events. Programming options allow restricting specific event reports to the central station receiver. A programming option allows the log to record certain functions entered at command centers.
Display the 1000 events in memory at the fire system controller(s) or retrieve them with a single phone call by a central station using Bosch RPS version 3.7.025 or higher.
The D9131A Parallel Printer Interface Module allows an onsite parallel printer to print events as they are stored in the log: recording time, date, account number, event, point ID, point text, and if the message was transmitted to a receiver.
Inputs
The D9124 Control Panel is a 127-point addressable system that is expandable to 246 addressable points. The control panel receives information from alarm initiating points through integrated devices over a two-wire multiplex zone expansion system. Each addressable point accommodates both normally-open and normally-closed devices with endof-line (EOL) resistor supervision. Each point is programmable for fire, fire supervisory, intrusion, or access control applications.
Outputs
System notification appliance capacity can be extended beyond the two supervised circuits by adding D8129 Octorelay Modules. Up to 128 relay outputs can be operated through the controller or the central station, or they can be programmed for automatic operations.
Notification appliances can be programmed for steady, pulsed, California March Time, or Temporal Code 3 patterns. Temporal Code 3 patterns can be synchronized using the appropriate synchronization modules.
Notification Appliance Circuits (NACs)
The D9124 FACP has two supervised, on-board NACs with individual circuit silencing.
User Interface
A D1256 Fire Alarm keypad is visible and accessible behind a locked, clear sliding panel located on the enclosure door.
It displays programmable text identifying specific initiating and supervisory devices. It also provides point annunciation, signal silence, trouble silence, detector reset, and annunciator reset. The sliding panel lock is keyed to match the Bosch manual pull stations for resetting the system.
Also available as options are:
•
D1255R Security/Fire Keypad
D1257 Remote Fire Alarm Annunciator
• D1260 Keypad
Certifications and Approvals
Region
USA
Hong Kong
Certification
UL AMCX: Central Station Alarm Units
(UL1610, UL1635), APAW: Police Station
Alarm Units (UL365, UL464), UOJZ:
Control Units, System (UL864)
FM
CSFM 7165-1615: 113 and 7170-1615:
144 July 2008
NYC-MEA 12-92-E, Vol. IV 12-92-E, Vol. IV
12-92-E, Vol. X11 12-92-E, Vol. 12
HKFSD
Installation/Configuration Notes
Compatible Products
The following products are compatible with the D9124
FACP:
Category
Batteries and
Power Supply
Products
Product ID Product Description
BATB-40 Battery box
Detectors
Keypads and
Annunciators
BATB-80
D126
D1218
D7038
D285
D285TH
D298M
D298S
FMM-462
D603
D604
D605
D720B/R
Battery box
12 V, 7 Ah standby battery
12 V, 18 Ah standby battery
Power supply address circuit module
Photoelectric smoke head
Photoelectric smoke head with heat
Zonex smoke master base
Zonex smoke single base
Manual station
Rate-of-rise heat detector head
Fixed (135°F) heat detector head
Fixed (190°F) heat detector head
Security and fire keypads
Modules
D1255B/R Security and fire keypads
D1256 Fire command center
D1257 Remote fire alarm annunciator
D1260
D125B
D129
D130
D136
D192C
D192E
ATM keypad
Powered loop interface module
(Dual, Class B)
Initiation circuit module
(Dual, Class A)
Relay module
Plug-in relay
Bell supervision module
Bell supervision module
D9124 Addressable Fire Alarm Control Panel (FACP) | 3
Category
Programming
Products
Product ID Product Description
D192G Bell supervision module
D8125 POPEX module
D8125MUX Zonex to dual multiplex interface
D8128D
D8129
OctoPOPIT module
Octo-relay module
D8130
D9127U
D9127T
D9131A
DX4020
D5200CE
Release module
POPIT module (no tamper)
POPIT module (tamper)
Parallel printer interface module
Ethernet interface module
Handheld programmer
RPS
RPS-LITE
RPS-INTL
Remote Programming Software
Remote Programming Software
Remote Programming Software
Parts Included
The D9124 Addressable Control Panel is shipped in three boxes. One box contains:
Quant.
Component
1 D9412GLTB Control Panel (less terminal blocks)
Another box contains:
Quant.
Component
1 D9101 Enclosure Assembly with Door
The third box contains a D9100 Accessory Module Carrier that includes the following:
Quant.
Component
1
1
2
1
D192C Indicating Circuit Supervision Modules
D928 Dual Phone Line Switcher
D8125 POPEX Module (additional optional)
D9142LC 24 VDC Power Supply
The third box also contains:
1
1
2
2
Quant.
Component
1
1
1
1
D1256 Fire Alarm Keypad
D1601 Transformer
Wiring Harness
Wiring Harness for the D8125 POPEX Module
560 Ω Resistors (for D192C Modules)
D161 Dual Modular Telephone Cords
D162 Dual Modular Telephone Cord
Literature pack
Technical Specifications
Environmental Considerations
Relative Humidity: Up to 85%; non-condensing
Temperature (operating): +32°F to +122°F (0°C to +50°C)
Inputs
Sensor Circuits: Up to two 8125 POPEX modules,
119 addresses per module
Sensor Circuit Protection: Power limited to 4 A; short circuit, reverse polarity, thermal overload and current overload protection on-board
Sensor Loop Technology: Four-wire addressable circuits
Mechanical Properties
Color:
Material:
Dimensions (H x W x D)
Enclosure Box:
Red
16-gauge (1.5 mm) steel
Removable Door:
36.1 in. x 22.1 in. x 3.2 in.
(92 cm x 56 cm x 8.1 cm)
37.1 in. x 23.3 in. x 1.1 in.
(94 cm x 59 cm x 2.8 cm)
Outputs
Off-board relays:
On-board NACs:
Power Requirements
Up to 16 optional D8129 Relay Modules (eight relay outputs per module)
Two; 1.8 A maximum per circuit
Current (operating)
Alarm + sensor load:
Idle:
Power (auxiliary):
Power (primary):
874 mA
412 mA
24 VDC nominal at 1.8 A
120 VAC, 60 Hz, 360 VA
Ordering Information
D9124 Addressable Fire Alarm Control
Panel (FACP)
Up to eight supervised or 32 unsupervised remote annunciators
Accessories
D113 Battery Lead Supervision Module
Supervises wiring connections for two 12 V batteries connected to the same set of charging terminals.
D122 Dual Battery Harness
Harness with circuit breaker. Connects two batteries to a compatible control panel.
D135A Low‑battery Disconnect Module
Disconnects the control panel from the battery when the battery level drops to 9.5 VDC.
D9124
D113
D122
D135A
www.boschsecurity.com
4 | D9124 Addressable Fire Alarm Control Panel (FACP)
Ordering Information
D127 Reversing Relay Module
Reports two separate alarm conditions to the central station.
D136 Plug‑In Relay
Maximum rating is 1 A at 24 VDC or 2 A at
12 VDC. Available individually (D136) or in a package of 25 (D136‑25).
D138 Mounting Bracket, Right Angle
Used to mount accessory modules in D8103,
D8108A, and D8109 enclosures.
D127
D136
D138
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180 [email protected]
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330 [email protected]
www.boschsecurity.com
© Bosch Security Systems Inc. 2010 | Data subject to change without notice
T1113332363 | Cur: en-US, V5, 4 Jul 2010
Asia-Pacific: Represented by
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6258 5511
Fax: +65 6571 2698 [email protected]
www.boschsecurity.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement