HoMedics AF-10 Downloadable Instruction Book
Add to my manuals
14 Pages
HoMedics AF-10 True HEPA Air Cleaner: Breathe easier with the HoMedics AF-10 True HEPA Air Cleaner. This air purifier features a True HEPA filter that captures 99.97% of airborne particles as small as 0.3 microns, including dust, pollen, pet dander, and smoke. It also has a pre-filter to capture larger particles, and an odor-reducing pre-filter to remove unwanted smells. Choose from three fan speeds for customized air purification, and let the Clean/Reset Filter Indicator remind you when it's time to clean or replace the filter.
advertisement
Correo electrónico: [email protected]
De lunes a viernes
8:30 a.m. a 7:00 p.m. (EST)
1-800-466-3342
GARANTÍA LIMITADA POR DOS AÑOS
HoMedics vende sus productos con la intención de que no tengan defectos de fabricación ni de mano de obra por un plazo de dos años a partir de la fecha de compra original, con las siguientes excepciones. HoMedics garantiza que sus productos no tendrán defectos de material ni de mano de obra bajo condiciones de uso y servicio normales. Esta garantía se extiende únicamente a consumidores y no a distribuidores.
Para obtener servicio de garantía en su producto HoMedics, póngase en contacto con un
Representante de Relaciones con el Consumidor por el teléfono 1-800-466-3342 para obtener asistencia. Asegúrese de tener a mano el número de modelo del producto.
No se aceptarán pagos contra entrega.
HoMedics no autoriza a nadie, incluyendo, pero sin limitarse a, distribuidores, posteriores consumidores compradores del producto a un distribuidor, o compradores remotos, a obligar a
HoMedics de forma alguna más allá de las condiciones aquí establecidas. La garantía de este producto no cubre daños causados por uso inadecuado o abuso, accidente, conexión de accesorios no autorizados, alteración del producto, instalación inadecuada, reparaciones o modificaciones no autorizadas, uso inadecuado de la fuente de energía/electricidad, cortes de energía, caída del producto, funcionamiento incorrecto o daño de una pieza de funcionamiento debido al no cumplimiento del mantenimiento recomendado por el fabricante, daños durante el transporte, robo, descuido, vandalismo, condiciones climáticas, pérdida de uso en el período durante el cual el producto está en una instalación de reparación o a la espera de piezas o reparación, o cualquier otra condición, sin importar cual sea, que se encuentre fuera del control de HoMedics.
Esta garantía es válida únicamente si el producto es comprado y operado en el país en el cual se compró el producto. Un producto que requiera modificaciones o adaptación para habilitar su funcionamiento en cualquier país que no sea aquél para el que fue diseñado, fabricado, aprobado y/o autorizado, o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía.
LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA. NO HABRÁ NINGUNA
OTRA GARANTÍA EXPRESA NI IMPLÍCITA, INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN
O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A
PRODUCTOS CUBIERTOS POR ESTA GARANTÍA. HOMEDICS NO TENDRÁ RESPONSABILIDAD
ALGUNA POR NINGÚN DAÑO INCIDENTAL, CONSECUENTE NI ESPECIAL. BAJO NINGÚN CONCEPTO
ESTA GARANTÍA REQUERIRÁ MÁS QUE LA REPARACIÓN O CAMBIO DE ALGUNA PIEZA O PIEZAS
QUE SE HALLEN DEFECTUOSAS DENTRO DEL PERÍODO DE VIGENCIA DE ESTA GARANTÍA. NO
SE EFECTUARÁN REEMBOLSOS. SI NO HAY PIEZAS DE REPUESTO DISPONIBLES PARA LOS
MATERIALES DEFECTUOSOS, HOMEDICS SE RESERVA EL DERECHO DE REALIZAR SUSTITUCIONES
EN VEZ DE REPARAR O CAMBIAR.
Esta garantía no se extiende a la compra de productos abiertos, usados, reparados, embalados otra vez y/o abiertos y vueltos a cerrar, incluyendo entre otras cosas la venta de dichos productos en sitios de remate por Internet y/o la venta de dichos productos por revendedores o mayoristas. Todas y cada una de las garantías cesarán y terminarán inmediatamente con respecto a cualquier producto o pieza del mismo que estén reparados, cambiados, alterados o modificados sin el consentimiento previo explícito y por escrito de HoMedics.
Esta garantía le proporciona derechos legales específicos. Es posible que usted tenga derechos adicionales que pueden variar de un país a otro. Debido a las regulaciones de ciertos países, es posible que algunas de las limitaciones y exclusiones no se apliquen en su caso.
Por más información con respecto a nuestra línea de productos en los EE.UU., visítenos en: www.homedics.com
HoMedics® es una marca registrada de HoMedics, LLC.
© 2014 HoMedics, LLC. Reservados todos los derechos.
IB-AF10
Pl ea se
Tak e A Moment
Register
No w
Your Product At:
www.homedics.com/register
Your valuable input regarding this product will help us create the products you will want in the future.
True HEPA Air Cleaner
El manual en español empieza a la página 15
Instruction Manual and
Warranty Information AF-10
IMPORTANT SAFETY INSTRUCTIONS:
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN
CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER
– TO REDUCE THE RISK OF ELECTRIC SHOCK:
• Always unplug the air cleaner from the electrical outlet immediately after using and before cleaning.
• Keep cord away from heated surfaces.
• Always place the air cleaner on a firm, level surface.
• Always place the air cleaner at least six (6) inches away from walls and three (3) feet from heat sources such as stoves, radiators, or heaters.
• DO NOT operate where aerosol (spray) products are being used or where oxygen is being administered.
• DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
• DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
• DO NOT place in or drop into water or other liquid.
• Keep dry - DO NOT operate in wet or moist conditions.
• Check your air cleaner cord and plug connections. Faulty wall outlet connections or loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tightly in the outlet.
2
WARNING
– TO REDUCE THE RISK OF BURNS, FIRE,
ELECTRIC SHOCK OR INJURY TO PERSONS:
• Extreme caution is necessary when any air cleaner is used by or near children or invalids and whenever the air cleaner is left operating and unattended.
• Always unplug the air cleaner when not in use.
• Do not operate the air cleaner with a damaged cord or plug, or after the air cleaner malfunctions, or has been dropped or damaged in any manner. Return to HoMedics Consumer Relations for examination, electrical or mechanical adjustment, or repair.
• This air cleaner is not intended for use in bathroom, laundry areas and similar moist indoor locations. Never locate air cleaner where it may fall into a bathtub or other water container.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic areas where it can be tripped over.
• To disconnect the air cleaner, first turn controls to the OFF position, then remove plug from outlet.
• Do not tilt or move the air cleaner while it is in operation. Shut off and remove plug from outlet before moving.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the air cleaner.
• To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on any soft surface, like a bed, where openings may become blocked.
• Use this air cleaner only for its intended use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
• DO NOT use outdoors.
3
This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA. US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product.
The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model’s CADR for Dust and the electrical energy it consumes, or CADR/Watt.
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE
Technical Specifications
Input voltage
Rated Frequency
Power
Weight
Noise Level
Unit Height
120 V
60 HZ
38 Watts
8.50 lbs
<60 dB
13.5"
Main Features of the HoMedics True HEPA Air Cleaner
Control Panel HEPA Filter
Pre-Filter
Grill Cover
Main Unit
4 5
NOTE: This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature. To do so could result in an electric shock hazard.
Control Panel
Power ON/OFF Control Clean/Reset Filter Indicator Button
1 2 3
CLEAN FILTER
Fan Speed Selection (Low/Medium/High)
NOTE: The Clean/Reset Filter Indicator MUST be pressed to reset the indicator after you have cleaned and replaced the filter.
6
Operating Instructions
Turning the Unit On
• Take the air cleaner out of the box and remove the clear protective plastic bag.
• Place the air cleaner on a firm level surface.
• Before turning the air cleaner ON, you need to check that the True HEPA filter is firmly in place and did not become loose during shipping. You may also choose to install the optional odor reducing pre-filter.
1. To check the True HEPA filter, open the front grill by pulling on the tabs on either side of the top of the grill cover. Fig. 1
Fig. 1
2. Open the cover outward until the tabs at the bottom of the grill cover easily slide away from the unit. Fig. 2
Fig. 2
3. The True HEPA filter will be resting inside the unit. Make sure that the filter is firmly seated inside of the unit. Fig. 3
Fig. 3
7
Fig. 4
4. Place the tabs at the bottom of the grill cover into the base of the unit.
Gently push the grill cover back into place until you hear a click sound indicating that the grill is firmly latched. Fig. 4
Plug the power cord into a standard
AC outlet.
To Install Optional Odor Reducing Pre-Filter
Pre-Filter
1. Remove optional pre-filter from plastic bag.
2. Remove front cover from air cleaner unit. Fig 5-6
3. Attach pre-filter to adhesive on inside of front grill cover. Press firmly. Fig 7
4. Replace front grill cover on air cleaner unit. Fig 8
Fig. 5
Fig. 7
8
Fig. 6
Fig. 8
NOTE: Unit will not operate unless True HEPA filter and grill are properly installed.
1. On/Off and Fan Speed Settings
• To turn the air cleaner on, press the ON/OFF Control. When the air cleaner is on, the ON/OFF Control will illuminate and the air cleaner will start to operate on
LOW speed.
• This air cleaner has 3 fan speed settings: LOW (1), MEDIUM (2), and HIGH (3).
The higher the fan speed setting, the faster the air will be cleaned. To select or change fan speed, slide the FAN SPEED Control until desired speed is reached.
• To turn the air cleaner off, press the ON/OFF Control.
Clean Filter Indicator Button
This air cleaner is equipped with a CLEAN FILTER indicator button to let you know when the True HEPA filter requires cleaning. Generally this is every 480 hours of use. When the True HEPA filter requires cleaning, the CLEAN FILTER indicator button on the control panel will illuminate.
If the air cleaner is used daily, we recommend cleaning the True HEPA filter more frequently.
Replacing True HEPA Filter
With regular cleaning the life of the True HEPA filter is approximately 12-18 months under typical household usage and conditions. We recommend replacing your filter every year. To purchase replacement True HEPA filters, model # AF-10FL, go back to your retailer (where you purchased your air cleaner), or visit www.homedics.com.
After cleaning or replacing the True HEPA filter, be sure to reset the filter indicator by pressing the CLEAN/RESET FILTER INDICATOR
BUTTON for several seconds until an audible chime sounds and the light turns off.
9
Cleaning the True HEPA Filter
Make sure that the air cleaner is turned OFF and unplugged from the outlet before cleaning.
1. Open the front grill cover by gently pulling on the tabs on either side of the top of the grill cover. Fig. 9
Fig. 9
2. Open the grill cover outward until the tabs at the bottom of the grill cover easily slide away from the unit. Fig. 10
Fig. 10
3. Remove the True HEPA filter from the main unit. Fig. 11
Fig. 11
10
4. Use the brush attachment with your vacuum cleaner. Run the attachment along both sides of the True HEPA filter, cleaning thoroughly between the accordion folds of the filter. Fig. 12
Fig. 12
5. Place the clean True HEPA filter back in the main unit, making sure it is firmly seated inside the unit. Fig. 13
Fig. 13
6. Place the tabs at the bottom of the grill cover into the base of the unit. Gently push the grill cover back into place until you hear a click sound indicating that the grill cover is firmly latched. Fig. 14
Fig. 14
11
Cleaning and Maintenance
For best performance, we recommend:
• Vacuum the True HEPA filter and pre-filter using the brush attachment of your vacuum cleaner once a month.
• NEVER use water or any household cleaners or detergents to clean the True HEPA filter or pre-filter.
• Clean off the outside of the unit with a dry cloth once a month.
• NEVER use water, wax, polish, or any chemical solution to clean the outside of the unit.
• Clean off the grill cover using a damp cloth or the brush attachment of your vacuum once a month.
• NEVER use wax, polish, or any chemical solution to clean the grill cover.
• Replace the True HEPA filter every 12-18 months.
12
Troubleshooting
Problem
Unit will not operate
Possible Cause
• Unit is not plugged in
• No power to unit
Solution
• Plug unit in
• Press the ON/OFF button to turn the power on
• Check circuits, fuses, try a different outlet
Reduced airflow or poor filtering
Excessive noise
CLEAN FILTER indicator light will not go off
• The front grill may be blocked
• True HEPA filter may be clogged
• Check to make sure nothing is blocking the front grill and air outlet
• Check and clean filter
• Replace the filter
• The unit is not level • Place the unit on a flat, level surface
• The filter needs to be cleaned
• The filter needs to be replaced
• CLEAN/RESET
FILTER INDICATOR has not been reset
• Remove filter from unit and clean using brush attachment on your vacuum
• Replace filter –
Model # AF-10FL
• Press and hold the
CLEAN/RESET
FILTER INDICATOR
BUTTON until an audible chime sounds and the light turns off
13
e-mail: [email protected]
Monday-Friday
8:30 am – 7:00 pm (EST)
1-800-466-3342
LIMITED TwO YEAR wARRANTY
HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of two years from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service. This warranty extends only to consumers and does not extend to
Retailers.
To obtain warranty service on your HoMedics product, contact a Consumer Relations Representative by telephone at 1-800-466-3342 for assistance. Please make sure to have the model number of the product available.
No COD’s will be accepted.
HoMedics does not authorize anyone, including, but not limited to, Retailers, the subsequent consumer purchaser of the product from a Retailer or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/ power supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturers recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.
This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed, manufactured, approved and/ or authorized, or repair of products damaged by these modifications is not covered under this warranty.
THE wARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE wARRANTY. THERE
SHALL BE NO OTHER wARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED wARRANTY
OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE
COMPANY wITH RESPECT TO PRODUCTS COVERED BY THIS wARRANTY. HOMEDICS SHALL
HAVE NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES.
IN NO EVENT SHALL THIS wARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT
OF ANY PART OR PARTS wHICH ARE FOUND TO BE DEFECTIVE wITHIN THE EFFECTIVE PERIOD
OF THE wARRANTY. NO REFUNDS wILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE
MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT
SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired, repackaged and/or resealed products, including but not limited to sale of such products on Internet auction sites and/ or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are repaired, replaced, altered, or modified, without the prior express and written consent of HoMedics.
This warranty provides you with specific legal rights. You may have additional rights which may vary from state to state. Because of individual state regulations, some of the above limitations and exclusions may not apply to you.
For more information regarding our product line in the USA, please visit: www.homedics.com
HoMedics® is a registered trademark of HoMedics, LLC.
© 2014 HoMedics, LLC. All rights reserved.
IB-AF10
Tó me se un momento ah
Registre
ora su producto en:
www.homedics.com/register
Su valioso aporte sobre este producto nos ayudará a crear los productos que usted deseará en el futuro.
Limpiador de aire
HEPA auténtico
Manual de instrucciones e información de garantía AF-10
INSTRUCCIONES DE SEGURIDAD
IMPORTANTES:
CUANDO UTILICE PRODUCTOS ELÉCTRICOS, ESPECIALMENTE
CUANDO HAYA NIÑOS PRESENTES, SIEMPRE SE DEBEN CUMPLIR
CIERTAS PRECAUCIONES BÁSICAS DE SEGURIDAD, QUE INCLUYEN
LO SIGUIENTE:
LEA TODAS LAS INSTRUCCIONES ANTES DE USAR
PELIGRO
– PARA REDUCIR EL RIESGO DE DESCARGA
ELÉCTRICA:
• Siempre desenchufe el limpiador de aire del tomacorriente inmediatamente después de usarlo y antes de limpiarlo.
• Mantenga el cable alejado de superficies calientes.
• Siempre coloque el limpiador de aire sobre una superficie firme y nivelada.
• Siempre coloque el limpiador de aire por lo menos a 6 (seis) pulgadas de distancia de las paredes y a 3 (tres) pies de las fuentes de calor, como hornos, radiadores o calentadores.
• NO lo haga funcionar donde se utilizan productos de rociado por aerosol ni donde se está administrando oxígeno.
• NO intente tomar un artefacto que haya caído al agua. Desenchufe inmediatamente.
• NO coloque ni guarde el artefacto en un lugar donde pueda caerse o ser tirado hacia una tina o pileta.
• NO lo coloque ni lo deje caer en agua ni en ningún otro líquido.
• Manténgalo seco - NO lo haga funcionar si está mojado o en condiciones húmedas.
• Controle el cable del limpiador de aire y las conexiones del enchufe. Las conexiones defectuosas en el tomacorriente de la pared o los enchufes sueltos pueden hacer que el tomacorriente o el enchufe se sobrecalienten. Asegúrese de que el enchufe encaje justo en el tomacorriente.
16
ADVERTENCIA
– PARA REDUCIR EL RIESGO DE
QUEMADURAS, INCENDIO, DESCARGA ELÉCTRICA O LESIONES A
LAS PERSONAS:
• Se debe ser extremadamente precavido cuando cualquier limpiador de aire es usado por o cerca de niños o personas inválidas y cuando el limpiador de aire se deje funcionando sin supervisión.
• Desenchufe siempre el limpiador de aire cuando no lo esté usando.
• No haga funcionar el limpiador de aire con un cable o un enchufe dañado, o después de que el limpiador de aire no funcione adecuadamente, se haya caído o dañado de cualquier manera. Devuelva a Atención al consumidor de HoMedics para que lo examinen, lo ajusten eléctrica o mecánicamente o lo reparen.
• Este limpiador de aire no está diseñado para usarse en baños, áreas de lavado de ropa ni en ubicaciones húmedas similares en interiores. Nunca coloque el limpiador de aire donde pueda caer a una tina u otro contenedor de agua.
• No pase el cable por debajo de alfombras. No cubra el cable con tapetes, tapetes para corredor ni cubiertas similares. No pase el cable por debajo de muebles o electrodomésticos. Coloque el cable alejado de las áreas de tránsito en donde pueda ocasionar tropezones.
• Para desconectar el limpiador de aire, primero coloque todos los controles en la posición “OFF” (apagado) y luego retire el enchufe del tomacorriente.
• No incline ni mueva el limpiador de aire mientras esté en funcionamiento. Apáguelo y retire el enchufe del tomacorriente antes de cambiarlo de lugar.
• No introduzca ni permita que entren objetos extraños por cualquier abertura de ventilación o de escape ya que esto puede causar una descarga eléctrica o incendio, o dañar el limpiador de aire.
• Para evitar un posible incendio, no bloquee de ninguna forma las entradas ni los escapes de aire. No utilice sobre ninguna superficie blanda, como una cama, en donde las aberturas puedan obstruirse.
• Utilice este limpiador de aire solamente para el uso para el cual está diseñado y como se describe en este manual. Cualquier otro uso no recomendado por el fabricante puede causar incendio, descarga eléctrica o lesiones a las personas.
• NO lo use en exteriores.
17
Este producto obtuvo la certificación ENERGY STAR cumpliendo estrictas pautas de eficiencia energética establecidas por US
EPA. US EPA no respalda ninguna declaración del fabricante sobre aire interior más saludable a partir del uso de este producto.
La eficiencia energética de este modelo calificado según
ENERGY STAR se mide basándose en una relación entre la
CADR (tasa de suministro de aire limpio) para el polvo y la energía eléctrica que consume o CADR/vatio.
PARA REFERENCIA FÁCIL CONSERVE ESTAS INSTRUCCIONES
IMPORTANTES
Especificaciones Técnicas
Voltaje de entrada
Frecuencia clasificada
Corriente
Peso
Nivel de ruido
Altura de la unidad
120 V
60 HZ
38 vatios
8.50 libras
<60 dB
13.5"
Funciones principales del limpiador de aire HEPA
Auténtico HoMedics
Panel de control
Unidad principal
Filtro HEPA Auténtico
Prefiltro
Placa de la rejilla
18 19
NOTA: Este artefacto tiene un enchufe polarizado (una hoja es más ancha que la otra). Para reducir el riesgo de descarga eléctrica, este enchufe está diseñado para encajar sólo en un sentido en un tomacorriente polarizado. Si el enchufe no encaja completamente en el tomacorriente, dele la vuelta. Si aún no encaja, póngase en contacto con un electricista calificado. NO intente ignorar esta función de seguridad. Hacerlo podría tener como resultado un peligro de descarga eléctrica.
Panel de control
Control de energía ON/OFF
(encendido/apagado)
Botón indicador de limpieza/reajuste de filtro
1 2 3
CLEAN FILTER
Selección de velocidad del ventilador (baja/media/alta)
NOTA: El indicador de limpieza/reajuste de filtro DEBE presionarse para reiniciar el indicador después de haber limpiado y cambiado el filtro.
20
Instrucciones de uso
Encendido de la unidad
• Retire el limpiador de aire de la caja y quite la bolsa plástica protectora transparente.
• Coloque el limpiador de aire sobre una superficie firme y nivelada.
• Antes de encender el limpiador de aire, debe verificar que el filtro HEPA esté bien asegurado y que no se haya aflojado durante el envío. También puede optar por instalar el prefiltro opcional reductor de olores.
1. Para controlar el filtro HEPA, abra la rejilla delantera jalando de las lengüetas que se encuentran a ambos lados de la parte superior de la placa de la rejilla.
Fig. 1
2. Abra la placa hacia afuera hasta que las lengüetas de la parte inferior de la placa de la rejilla se deslicen fácilmente por la unidad. Fig. 2
Fig. 2
3. El filtro HEPA estará apoyado dentro de la unidad. Asegúrese de que el filtro se encuentre bien apoyado dentro de la unidad. Fig. 3
Fig. 3
21
4. Coloque las lengüetas que se encuentran en la parte inferior de la rejilla en la base de la unidad. Empuje la rejilla hacia atrás hasta que escuche un clic que indica que la rejilla se encuentra bien firme. Fig. 4
Fig. 4
Enchufe el cable de energía en un tomacorriente CA estándar. Enchufe el cable de energía en un tomacorriente
CA estándar.
Para instalar el prefiltro opcional reductor de olores
Pre-Filter
1. Retire el prefiltro opcional de la bolsa plástica.
2. Retire la cubierta delantera de la unidad limpiadora de aire.
Figuras 5 y 6
3. Fije el prefiltro a los sujetadores de gancho y aro en la parte interior de la cubierta delantera. Presione con firmeza. Fig. 7
4. Vuelva a colocar la cubierta delantera de la unidad limpiadora de aire. Fig. 8
Fig. 5
Fig. 7
22
Fig. 6
Fig. 8
NOTA: la unidad no funcionará a menos que el filtro HEPA y la rejilla estén correctamente instalados.
1. Encendido/apagado y configuración de velocidad del ventilador
• Para encender el limpiador de aire, presione el control ON/OFF (encendido/ apagado) .
Cuando el limpiador de aire esté encendido, el control ON/OFF (encendido/ apagado) se iluminará y el limpiador de aire comenzará a funcionar en velocidad
BAJA.
• El limpiador de aire tiene una configuración de 3 velocidades de ventilador:
BAJA (1), MEDIA (2) y ALTA (3). Cuanto más alta la configuración de velocidad del ventilador, más aire se limpiará. Para seleccionar o cambiar la velocidad del ventilador, deslice el control de VELOCIDAD DE VENTILADOR hasta lograr la velocidad deseada.
• Para apagar el limpiador de aire, presione el control ON/OFF encendido/apagado) .
Botón indicador de limpiar filtro
Este limpiador de aire está equipado con un botón indicador CLEAN FILTER (limpiar filtro) para informarle cuando es necesario limpiar el filtro HEPA. Generalmente esto es cada 480 horas de uso. Cuando sea necesario limpiar el filtro HEPA, se encenderá el botón indicador de LIMPIAR FILTRO en el panel de control.
Si se usa el limpiador de aire diariamente, le recomendamos limpiar el filtro HEPA con más frecuencia.
Cambio de filtro HEPA
Con la limpieza regular la vida útil del filtro HEPA es de aproximadamente 12 a 18 meses en condiciones de hogar y uso típicas. Recomendamos cambiar su filtro todos los años. Para comprar filtros HEPA de repuesto, modelo
AF-10FL, diríjase a su distribuidor (en donde compró su limpiador de aire) o visite www.homedics.com.
Después de limpiar o cambiar el filtro HEPA, asegúrese de reiniciar el indicador de filtro presionando el BOTÓN INDICADOR LIMPIEZA/
REINICIO DE FILTRO durante varios segundos hasta que se escuchen sonidos de campanadas y las luces se apaguen.
23
Limpieza del filtro HEPA
Asegúrese de que el limpiador de aire esté apagado y desenchufado del tomacorriente antes de limpiar.
1. Abra la rejilla delantera jalando de las lengüetas que se encuentran de cada lado de la parte superior de la placa de la rejilla. Fig. 9
Fig. 9
2. Abra la placa hacia afuera hasta que las lengüetas de la parte inferior de la placa de la rejilla se deslicen fácilmente por la unidad. Fig. 10
Fig. 10
3. Retire el filtro HEPA de la unidad principal.
Fig. 11
Fig. 11
24
4. Use el accesorio de cepillo con su aspiradora. Pase el accesorio por ambos lados del filtro HEPA, limpiando bien entre los pliegues plisados del filtro. Fig. 12
Fig. 12
5. Vuelva a colocar el filtro HEPA en el limpiador de aire en la dirección que indican las flechas en los lados del filtro.
Asegúrese de que el filtro se encuentre bien apoyado dentro de la unidad.
Fig. 13
Fig. 13
6. Coloque las lengüetas que se encuentran en la parte inferior de la rejilla en la base de la unidad. Empuje la rejilla hacia atrás hasta que escuche un clic que indica que la rejilla se encuentra bien firme. Fig. 14
Fig. 14
25
Limpieza y mantenimiento
Para un mejor desempeño, recomendamos:
• Aspire el filtro HEPA usando el accesorio de cepillo de su aspiradora una vez al mes
• NUNCA use agua ni ningún otro limpiador o detergente doméstico para limpiar el filtro HEPA
• Limpie el exterior de la unidad con un paño seco una vez al mes
• NUNCA use agua, cera, lustrador ni ninguna otra solución química para limpiar la parte externa de la unidad
• Limpie la placa de la rejilla usando un paño húmedo o el accesorio de cepillo de su aspiradora una vez al mes
• NUNCA use cera, lustrador ni ninguna otra solución química para limpiar la placa de la rejilla
• Cambie el filtro HEPA cada 12 a 18 meses
26
Diagnóstico y resolución de problemas
Problema Causa posible
La unidad no funciona • La unidad no está enchufada
• La unidad no recibe energía eléctrica
Flujo de aire reducido o poca filtración
• La rejilla delantera puede estar obstruida
• Un filtro HEPA puede estar obstruido
Ruido excesivo
La luz indicadora de
LIMPIAR FILTRO no se apaga
• La unidad no está nivelada
• Debe limpiar el filtro
• Debe cambiar el filtro
• No se ha reiniciado el INDICADOR DE
LIMPIEZA/REINICIO
DE FILTRO
Solución
• Enchufe la unidad
• Oprima el botón ON/
OFF para encenderla.
• Revise los circuitos, los fusibles; pruebe otro tomacorriente
• Verifique que no haya nada obstruyendo la rejilla delantera y la salida de aire
• Verifique y limpie el filtro
• Cambie el filtro
• Coloque la unidad en una superficie plana y nivelada
• Quite el filtro de la unidad y limpie usando el accesorio de cepillo de su aspiradora
• Cambie el filtro – N.º de modelo AF-10FL
• Mantenga presionado el BOTÓN INDICA-
DOR DE LIMPIEZA/
REINICIO DE FILTRO hasta escuchar un sonido de campana y que la luz se apague
27
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- 60 dB
- Number of speeds: 3
- HEPA filter Removable filter
- 38 W
- Black