T&+1 01

3

Installation and

UseMareGuide

Model and serkl number plate

-(behlndfrontpanel)

Control panel r

Control panel

I

Model and serial number

Models

AIR CONDITIONERS

ACS602 ACS802 ACSlOP ACC602

a-%

Contents

Important Safety Instructions. . . . , . . . .

Electrical Requlnments . . . . . . . . . , . . . .

Receptacle wiring . . . . . . . . . . . . . . . , . . . .

Electrical requirements . . . . . . . . . . . , . . . .

Elect&al connection . . . . . . . . . . . . . . . . .

Instsllatlon Instructions. . . . . . . . . . . . . ,

Installation instructions for models

ACS602, ACS602 and ACS102 . . . . . .

Installation instructions for model ACC602 . . . . . . . . . . . . . . . . . . . .

Operating Instructions . . . . . . . . . . . . . . .

Starting your air conditioner . . . . . . . . . . .

The exhaust control . . . . . . . . . . . . . . . . . .

Changing air direction . . . . . . . . . . . . . . . . .

Cleaning and caring for your air conditioner . . . . . . . . . . . . . . . . . . . . .

H You Need Service Or Assistance . . . .

WhIrlpool Room Alr Conditioner

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . .

01990 Whirlpool Corporation

P&N

-2

3

mportant Safety nstrudions

:

3

4

4

6

11

11

11

11

12

15

16 r0 reduce the rtsk of firs, Mctrksl shock of mraonai injury wbeh using your air condi-

:ioner, follow these basic precautions:

1 Read ail instructions i&ore using your air conditioner.

1 Complete the installation requirements as described in the instaliatlon Instructions.

) Never allow chlidren to operate or piay with the air conditioner.

) Do Not operate the alr conditioner with tbs front panel removed.

1 Never clean air conditioner parts with flammable fluids. The fumes can create a fire hazard or explosion. l

FOR YOUR SAFETY. l l

Thank you for buylng a Whirlpool appliance.

Piease complete and mall the Owner

Aeglstratlon Card provided wlth this prod- uct. Then complete the form below. Have this information ready if you need service or call with a question.

Copy model and serial numbers from plate

(see diagram on page 12) and purchase date from sales slip.

Keep this book and sales slip together in a handy place.

M-1 Number

Sertrl Number

Purchaee Date

Ssrvka Com~nny Phone Number

DO NOT STORE OR USE GASOLINE OR

DTHER FLAMMABLE VAPORS AND LIG-

UIDS IN THE VICINITY OF THIS OR ANY

DTHER APPLIANCE. THE FUMES CAN

CREATE A FIRE HAZARD OR EXPLOSION. t is your responsibility to be sure your air conditioner:

) Is installed in a window that will hold the weight, and is secured according to the

Installation Instructions.

B Is connected only to the proper kind of outlet, with the correct electrical supply and grounding. (See Installation Instructions.)

) Is the right size for the area you want to cool.

D Is used only to do what window air condi- tioners are designed to do.

) Is not used by anyone unable to operate it properly.

B Is properly maintained.

) Also, remove the Energy Label and Buy

Guide. Use a damp cloth to take off any glue residue. Do not use sharp instruments, flam- mable fluids or abrasive cleaners. These can damage the material.

- SAVE THESE INSTRUCTIONS -

Electrical requirements are different for the two models pictured on the cover, depending on the ampere rating of your unit. The number of amperes is printed on the serial plate, which is attached to the front of the unit behind the front panel. (See diagram on page 12.)

Observe all local governing codes and ordinances.

Do not, under any circumstances, remove the power supply cord grounding prong.

Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring installed by a qualified electri- cian. Observe National Electrical Code and all local governing codes and ordinances.

&Prong l l l

Electrical Shock Hazard

Check with a qualified electrician if you are in doubt as to whether the appliance Is properly grounded. Do not modify the power supply cord plug - if it will not fft the outlet, have a proper outlet installed by a qualified electrician. improper connection of the equipment-grounding conductor can result In a risk of eiectrlcai shock.

Do not use an extension cord with this appliance. Such use may resuit In a fire, eiectrlcai shock or other personal Iniuw.

Do not have a fuse in the neutral or grounding circuit. This could result In a risk of eiectrlcai shock.

A 115 volt, 60 Hz AC only, 15 ampere fused elec- trical supply is required (time delay fuse or time delay circuit breaker required). It is recommended that a separate circuit, serving only this appliance, be provided for models with serial plate amperes up through 7.5. A separate circuit is required for models with serial plate amperes of 7.6 through 12.0.

Electrical connection

Electrical ground is required on this appliance.

Recommended grounding method

For your personal safety, this appliance must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong grounding type wall receptacle, grounded in accordance with the National Electrical Code, ANSVNFPA 70-l&

(or to the latest), and local codes and ordinances.

If a mating wall receptacle is not available, it is the responsibility of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.

3

Eloctrlcal Rsqulramsnts

Continusd

Electrically grounded metal coid water pipe

(removepelnt,etc.) 7 f

Grounded eyelet

~‘- 1

Ground assembly

(attach to grounded metal cold water pipe) t--Gmundlng-

1 all receptacle

Temporary grounding msthod

If changing and property grounding the wall recap tacle is impossible and where local codes permit

(consuft your electrical inspector), a temporary adapter may bs plugged into the existing P-prong wall receptacle to mate with the 3-prong power supply cord. This, however, is not recommended.

If this is done, however, you must connect the grounded eyelet on the adapter to the wall mcep tacfe cover plate screw and from this same screw, you must connect a separate copper ground wire

(Xl4 minimum) to a grounded cold water pipe.

‘Do not ground to a gas supply pipe. Do not connect to electrfcal supply until appliance is grounded. Do not, under any circumstances, remove the power supply cord grounding prong.

‘Cold water pipe must have metal continuity to electrical ground and not be interrupted by pIas- tic, rubber or other electrically insulating corlneC- tors (including water meter or pump) wfthout adding a jumper wire at these connections.

For models ACS602, ACS802 and ACSlOP, follow installation instructions below. For model ACC802, follow installation instructions on page 8.

Instructions

ACM02 and ACSIM

To help avoid any installation problems and to help assure trouble-free perfomtance of your new air conditioner, read these installation instructions, as well as the operating instructions and electrical requirements before installing your unit. l l l

Personal InJury Hazard

Because thls air conditioner wslghs about

90 to 105 pounds, it is recommended that you have somsons hsip you Install your nsw unit and that you both uss propsr lift- ing techniques.

Inspect the condition of ths wlndow whefa ths air condftionsr will be Installed. Bs sure it wlii support the weight of ths unit. mh appliance must be Instalisd accord ing to ail applicable codes and ordinances.

0 Handle ths air wndttlonsr wlth care.

Watch out for the sharp metal ffns on ths front and rear colis. l

Be sum air conditioner doss not fall oui of window during or aftsr lnstaliatlon. m Do not uss ths collected watsr for drinking purposes. It is not sanitary.

Faiiurs to follow ths abovs prsoautions could msuit In psrsonal Injury.

1. Unpack mounting parts before installing your air conditioner. Make sure you have all the necessary parts. A normal installation can be made with a screwdriver, saw, small level, pocket knife, tape measure, drill and Ye: VW” and %s” drill bits.

Description of parts

1 Shelf (1)

2 Support bracket (1)

3 Sill bracket (1)

4 VW” bolt (2)

4A %s” nut (2)

48 W’ flat washer (2)

4C

%6’ lockwasher (2)

5 Translucent panel (1)

6 Screw-10x1”(2)

6A screw - 10 x

13/4”

(2)

7 Screw - 8 x Vi” (5)

8 Side seal strip (1)

9 Lower track seal (1)

10 Locking bracket (1)

11 Foam seal strip (1)

12 Panel frame (1)

13 Thread cutting screw

#B/J2 x

W’

(4)

If using Item 13 for fastening Item 10 or 12 to metal or plastic, use VW” dia. or #28 drill.

2. Pick the correct window. First, decide what room(s) you want to cool. Then choose a window that will allow the air-conditioned air to flow freely and directly into the room(s) you want cooled.

Remember, it’s difficult to move air around corners.

If the inner sliding window slides to the left, the unit will be installed on the right. Remove window screen if there is one. Choose a sliding window that’s also near an electrical outlet. (Refer to

“Electrical Requirements” on page 3 for type of receptacle and wiring needed.) Do not use an extension cofd.

The sliding window in which you place your air conditioner should have an opening of at least

15%” wide and 21%” to 40%” high (see diagram).

For installations up to 62%” high, a special kit (Part

No. 977449) is available. For windows as low as

20%~‘: you must install without filler frame and remove top angle on unit, reinstalling 3 screws into top of cabinet.

This model may also bs installed in steel hinged casement windows. The steel hinged casement window must have an opening at least 15%” wide and no more than 18%” wide.

3. Place shelf in window wlth tabs down against the track surface.

5

8

Instdlsth

Contlnwd

InstmcUoms

Room side t

-It=-“‘”

Uw screws 5 or 5A

Prodrill ‘Hu” holes if truks are metal

4. Attach support bracket (Item 2) loosely to the underside of shelf with either short or long leg down and with end of bracket either toward or away from window, depending upon con&uction and depth of wall and window sill (see diagram).

Attach sill bracket (Item 3). Each bracket is attached using one %s” bolt, nut and washers

(Items 4,4A, 48 and 4C).

5. With the assembled shelf and brackets still in the window opening, adjust brackets until she8 is firmly seated and sloping down to outsiie. If you

Wtiout a level, place the translucent panel (Item

5) on shelf. The top of long side of the panel will be

%s” back from the window line (see diagram).

5. If slope back is correct, tighten all nuts securely. Install lower track seal (Item 9) shown in diagram. This track seal has two holes which line up with matching screw holes in shelf.

7. install shelf 2%” from side of window open- ing, securing it in place with screws 6 or 8A.

8. Measure height of opening (see diagram).

Subtract 20%~” from measured height. This will be the actual height of translucent panel.

9. Measure out the distance determined in

Step 8 and mark it along the 20%” side of translu- cent panel. Clamp panel between a board and an appropriate supporting surface close to the mark and cut with fine tooth saw. Remove burrs.

10. Lift vertically removing panel frame from unit. Slide translucent panel into groove in frame, keeping honeycomb side to the face side of frame

(see diagram). Slide frame back into place on unit.

Panel should enter the top angle groove.

11. Peel backing from seal strip (Item 8) and press it onto side filler frame guides on each side of unit. seal strip

Slldlng sash sod strip

IL

. sesl strip

12. Place unit in window by testing unit on shelf. Push unit toward window so side angles are sealing against the side jamb stop (see diagram).

Slide the opened window sash firmly to make cer- tain the frame and unit sealing strips are sealing.

13. Using %I” drill, install locking screws

(Item 7). Use two screws in top jamb and in the side bottom flanges. If you need additional holding strength, add two more screws at upper sides of filler frame (marked “A’). Also, two screws can be added at unit sides (marked “6”). However, if you add screws at “6,” you must use a %I$ drill bit to predrill through the plastic sides of air conditioner.

Slldlng sash

14. Lock the sliding sash at bottom using lock bracket (Item 10) and screw (Item 7) as shown in diagram at left. Use a W’ drill bit to drill through track before inserting screw.

Thck

(room side)

15. Cut seal strip (Item 11) to length. Install it between space of opened sash and glass of the closed sash (see diagram).

7

8

Mdsngk

16ort66au6a

Addwood ushown

Add l

ngt8 towoodstop

16. For lnstallatlon In windows havlng no side flanges or with wood stops.

The flanges (top and two sides) on the air condi- tioner must mate against companion flanges on the window, not more than %s” (.2 cm) in thickness.

On the side with the opened sash, the leading edge of the sash becomes the flange. On the top and jamb side of most metal windows, the flange is there.

In windows where there are no flanges or where there are thick wood flanges or stops, use metal angles or wood to provide a stop for the unit flange. Diagrams at left show three suggested methods.

17. For installation in steel casement windows.

Follow Steps 2 and 3 on page 5. NOTE In

Step 3, the shelf tabs must butt to the front of fhe bottom angle on the casement (see diagram at left).

When Step 3 Is flnlshed, follow Steps 4 through 10 on page 6, and Steps 11 and 12 on page 7. Then proceed with the final two para- graphs in this Step 17, which immediately follow.

Open wlndow at least 18(p to allow room for unit cabinet. If necessary, remove window crank handle so the window will open wide enough. Tii opened window to the wall or frame to prevent the window from swinging.

Drill Vu” holes in the window jamb top to line up with holes in filler frame (see diagram at left). Use two thread cutting screws (Item 13) to secure unit. If you need additional holding strength, add screws at the bottom of the unit side channels (see Step 13 diagram). y l

14%”

I

Center unlt In

RI valkbk eponhq i Room

instructions model ACC602

To help avoid any installation problems and to help assure trouble-free performance of your new air conditioner, mad these installation instructions, as well as the operating instructions and electdcal requirements before installing your unit.

Inspect the condition of the window where the air conditioner will be installed. Be sure it will support the weight of the unit.

I Personal InJury Hazard

Bewraalrcondltlonerdoesnotfalloutof window during InsfallaUon. Pomona1 InJury ordamagecoufdruult.

I

l

Fersonal InJury M

Becauss this alr condltloner weighs &out

78 to 75 pounds, it Is recom- that you have somsone help you Install your newunltandthatyoubothuse~llft- lng techniques. l l

This appliance must be Installad according to all appllcabla codes and ordinances.

Handle the air condltloner wlth care.

Watch out for the sharp metal flns on ths front and rear tolls. l

Do not use the collected water for drlnklng purposes. lt Is not sanitary.

Fallum to follow ths above precautkns could result In parsonal InJury.

1. Unpack mounting parts before installing your air condiiioner. Be sure you have all the net- essary parts (see top two diagrams at left). This air conditioner will fit most steel casement windows. A nom-rat installation can be made with a screw- driver, W socket driver, tape measure and drill.

Description of parts (top two diagrams at left)

1 #lO x 3/e” long s.m. screw

2 #l O-32 x 3/e long math. screw

3 Bottom mounting bracket

4 Knurled knob screw

5 Top mounting bracket

NOTE: Above parts (not shipped loose) installed on unit by factory.

2. Pick the correct window. First, decide what room(s) you want to cool. Then choose a window that will allow the air-conditioned air to flow frwfy and directly into the room(s) you want cooled.

Remember, its diiicult to move air around comers.

Choose a window that’s alao near an ektrical outlet. (Refer to “Electrical Flequirlements” on page 3 for type of mceptacle and wiring needed.)

Do not use an extension cord.

To be able to use the window mounting parts shown in the diagram to the left of Step 1 aboW, the window should have a minimum width of 14%” and a maximum width of 16” (see “A” in bottom diagram). Ths window shoufd have a minimum height of 10%” and a maximum height of 11W

(see 9” in bottom diagram).

3. Remove the glass from the frame opening selected. Clear away any hardened putty.

4. Before slldlng unit through the casement opening, remove the bottom window bra&t

(Item 3) on both sides of the unit. NOTE: Only the topscmws(lteml)needtoberemoved.

9

Inst8lktlon In-s

Continued

5. Check the knurled knob screws to see that the top mounting brackets (Item 5) are Mracted to the center of the unit. They must not interfere witft the window frame when the unit is installed.

6. Lift the unit into the window opening and slide it back until the mounting frame comes into contact with the window frame.

10 shestlnsw

SWOWS-

7. Replace the bottom mounting brackets

(Item 3) by hooking the bracket over the window frame. Replace the top screws (Item 1) in the mounting bracket, leaving them loose enough so them is about %s” of play Tighten the bottom screws (Item 2). This will pull the unit mounting flange tightly to the window frame, sealing and locking the air conditioner in place.

Y4”

Max. -I I_

Back of air condltlonor

8. Loosen the two knurled knob screws and slide the top mounting bracket (Item 5) toward the outside of the unit, engaging the window frame.

Tighten the knurled knob screw in this position.

This will lock the unit in place so it cannot tftt into the room. The Installation Is now complete.

9. Optional mounting instructions. If the win- dow thickness will not allow you to use the four mounting brackets provided with the unit, remove brackets and fasten flanges of unit with sheet metal screws. These screws are not included with your air conditioner. The window opening for your installation must not be wider than 151

CLDWD

WEW

CLDSED

“Ml, OFF

LO Coo(

Fan only

WIT DFF

Starting your air conditioner

l.Setexhaustcont~0I(iiyourunitisso equipped) to CLOSED for maxfmum cooling.

2.ChooseeitherLOCOOLorHICOOLfan speed aetling.

LOCOOL . . . . . . . . . . . . . . fors&epklgcomfort

HICOOL . . . . . . . . . . . . . . formaxfmumcooflng

FANONLY . . . . . . . . . . . . forcim&tfngroomeir whennocoolinglsdealled

3. lbrn the thermostat conb’olto06

(mid-setting). You can a@st the air amWooer cooling performance by-%l* L control to a higher number for IM&UTI cooling.

Lower the number setting for less arolfng. Mu wfll need to experiment to find the setting which s&3 you best.

NOTE: If you turn your air conditioner off or if the compressor shuts off, wait at least tfuee minutes before turning it back on or you may blow a fuse or trip a circuit breaker.

The exhaust control setting draws stale or smoky air from the room.

1. To exhaust room alr

Set exhaust control to OPEN. Adjust fan control to speed desired. If no cooling is desired, use FAN

ONLY setting.

2. To circulate room alr

Set exhaust control to CLOSED. Adjust fan control to FAN ONLY

The louvers in the grille area at the top of the air conditioner control the direction of the coofed air

If your untt looks Ike Flgure A, move the lever at the top of the grille to the right, feft or straight ahead. Simply move the lever in the direction you want the air to go.

me rear verkal

louvers in the grille can be adjusted left, rfght or straight ahead. The front set is fixed and directed upward.

If your unit looks Ike Figure B, turn the circular air discharge grilles on top of the unit. Both grillescanbeadjustedtotherfghtorfeft+orad- justed indivfdually.

11

Model and wrlal number

and caring for your air conditioner

Proper use and care of your air condiiner will help ensure lonaer life of the unit and lower operat- ing’costs. Follow these instructions carefully.CalI your Whirlpool servicing dealer for an annual checkup.

Cleaning front panel

Mod.1 and urlal numkr plate l l

ElectrIcal Shock and

Flra Hazard

Unplug power cord from receptacle before cleaning unlt. Failure to do so could mlt

In electrical shock or personal Injury.

Do not use flammable flulds, solvents, abrasive cleaners, or strong detergents.

Fire or product damage could result.

1. Remove the front panel from unit when clean- ing. Press down at top edge of the front, as shown in diagrams at left (depending on your model).

2. When the front moves away from top of cabinet, pull top of front toward you.

3. Lift up and away from the bottom spring clips.

4. Clean front panel with warm water and mild soap or detergent. Use a soft cloth. Rinse and dry. Replace front panel.

5. Wipe control panel clean with a soft dry cloth.

Cleaning air conditioner filter

The filter is cleanable. A clean filter helps remove dust, lint and other particles from the air. Check every two weeks to see if filter needs cleaning.

1. Remove front panel as shown above.

2. Remove filter by releasing it from plastic clips as shown in diagrams at left (depending on your model).

3. Clean filter, using a vacuum cleaner.

-OR-

4. If very dirty, wash filter with warm water and mikf detergent. Air dry thoroughly before replacing.

Annual maintenance for your air condttloner l l l

Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year.

Call the service company recommended by your dealer to:

Inspect and clean the coils and condensate water passages.

Check fan and oil the fan motor.

The compressor is sealed and needs no oiling.

Expense of annual inspection is customer’s responsibility.

-OR- lf you are familiar with electrical appliances, you can do the cleaning and maintenance yourself. If you choose to do so, follow these steps:

1. Disconnect power supply.

2. Remove unit from cabinet. Wrap the motor, electrical control box and electrical terminals boxinplasticfilmandmakesumnowateror other liquid gets inside any of these parts. lt could damage the insulation and cause serious trouble.

3. Carefully clean and hose out the base, coils and condensate pans. Clean at least once a year or more often if the condenser coils and pans col- lect dirt, sand, leaves, insects or algae. Also, cleanifyoudetectanodorfmmtheaircondf- tioner. While the cabinet is open, this is a goal time to oil the fan motor. See page 14.

4. Remove plastic film from motor and elecfri& parts.

5. Replace unit in cabinet.

6. Reconnect power supply.

NOTE: II is a good idea to wait 24 hours before starting the unit again. This albws time for all amastodryout.

EbctrlcalShockand

Personal Injury Hazard

l Dbconnwtpowercordfromreceptwb

before performlng any maintenance. Be sure no llquld gets Into the motor, ebctrkal control box or compwsor ebctrkal termlnab. l

Ebcause your alr condltloner weighs fmm

70to105pounds,ltbrecommendEdtha youhavetxBmaonahelpyouwhenyou remove and reinstall your unlt and that yoUbothll&9propMllftlngbChfIlq~. l

Handb the alr condmmrwtthcare.

Watchoutforthesharpmetalflnsonthe front and reer colb.

l

Donotu6ethecolbctedwaferfordrlnklng purposea. ft Is not sanltafy.

Fallure to follow the above precmutlona couldmsultInebcWcal

-or-

Ww

13

14

Olllng the fan motor

Electrlcal Shock Hazard

Disconnect power cord from receptacle before oiling motor. Fallure to do so could result In personal InJury.

1. Oil the fan motor per instructions on the motor.

To add oil, pull out the oil hole plug at each end of the motor (see diagram). An easy-to-use one-ounce capsule of especially recommended oil (Part No. 10943) can be ordered from your

Whirlpool servicing dealer, or use SAE X20 non-detergent oil.

2. Replace the plug to keep dirt from motor bearings.

3. Reinstall the unit in cabinet after performing maintenance. Refer to the “Installation instruc- tions” section for your unit. l l l l l l l

Energy saving tips

Improve home insulation (seal doors, windows, and close fireplace flue).

Close blinds or drapes on sunny side of house; add window awnings.

Keep air filter clean. Don’t block air flow with drapes or furniture.

Ventilate attic (high temperature levels add to normal cooling load).

Try not to use heat producing appliances during the honest part of the day. Turn lights, radios, televisions, and other appliances off when not needed.

Keep heat registers and cool air returns closed or blocked off so cooled air won’t escape.

Use a vent fan in areas where cooking, laundry, or bathing is done to pull out extra heat and moisture near its source.

If You Need Service Or Assistance these steps:

1. gefore calling for assistance...

Performance problems often result from little things you can Lnd and fix your& without tools of any kind.

Air oendWonor won? run: l l l

Is unit plugged into a live circuit with proper voltage?

Is swttch turned on?

Is thermostat set correctly? l l

Has a fuse blown or a circuit breaker tripped?

Has the local power failed? l l

Unit blows fuses or trips circuit breaker:

Am time-delay fuses being used?

Is an extension cord being used? (Do not use an extensfon cwd to run your air condltloner.) l

Are you waiting three minutes after turning cooling circuft off before trying to restart unit?

Unittumsonandoff,ordoesnotcooiroom: l l

Is fitter clean?

Am coils clean (both evaporator [inside] and condenser l b-w)?

Is there excessive moisture or heat (open vessel cook- ing, showers, etc.)? l

Try setting fan to higher speed. l

Try setting thermostat to a cooler setting. operating sounds: l

When your room air conditioner is operatfng nomuiiy, you will hear sounds such as: l

Droplets of water hitting the condenser, causing a

‘pinging” or “clicking” sound. Water droplets help to coolthe condenser. l l l

Air movement from the fan, especially on high fan speed -%I.

Clicks from the thermostat cycle.

Sounds also may be caused by house construction - such as vibration of the unit due to wall construction or unsteady window mounting area.

2. if you need assistance’...

Call WhIrlpool COOL-LINE@ wrvlco assistance w

. IntheU.& numkr. Dfai free from a-r, l-am-253-1301 andtatkwkhoneofourtrainedconsuttants.Theconsul- tantcaninstructyouinhowtoobtafnsattsfactoryopera- ttonfromyourapptianceor,ifsewiceisneceeaary, tecomrnencl a qualified senrice company in your area.

3. if you need service?.. vkf l9

Whirtpoolhasanationwide

01

- workof-Whi& ssnriceannpaniw3.whirlpool

(KRVICE servicetechniciansar9batned tofllHilltheprodlGt~and provide after-warranty servtce, anywhere in the united

States. To locate the authorized Whfdpool m con+ pany in your area, call our COOL-LINE0 m as&t- ante telephone number (see Step 2) or bok In your telephone directory Yellow Pages under:

-

SERVICE COMPANIES

XYf2;EMy;; CO

.%9-m

4. if you have a problem:..

Call our COOL-LINE service assistance telephone number (see Step 2) and talk with one of our cons~fMM% or if you prefer, write to:

Mr. Donald Skinner

Director of Consumer Relations

Whirlpool Corporation

2ow M-63

Senton Harbor, MI 49022

Please include a daytime phone number in your correspondence.

6. if you need FSP@ replacement parts?..

FSP is a registered trademark of Whirlpool Corporation for qualii parts. Look for this symbol of quatii w you need a replacement part for your Whirtpool appliance. FSP replacement parts will fit rtgM and ti right, because they are made to the same exacting spec- ifications used to build every new Whirlpoot appliance.

To locate FSP replacement parts in your area, refer to

Step 3 above or call the Whirtpool COOL-LINE m assistance number in Step 2.

6. if you are not satisfied with how the pro&km was soived~.. l

Contact the Major Appliance Consumer Action Panef

(MACAP). MACAP is a group of independent am- sumer experts that voices consumer views at the high- est levels of the major appliance industry. l

Contact MACAP only when the dealer, authorized sew- icer or Whirlpool have failed to resofve your problem. l

Major Appliance Consumer Actton Panet

20 North Wacker Drive

Chicago, IL 6CNO6

MACAP will in turn inform us of your actton.

‘When requesting assistance, please provtde: model number, serial number, date of purchase, and a oompietedeacripiionoftheprobtem.Thle~ isrwededinordertob&errespondtoyourrequeet.

15

Room Air Conditioner

Warranty

LENGTH OF WARRANTY 1 WHIRLPOOL WILL PAY FOR

FULL OWE-YEAR WARRANTY

From Date of Purchase

FSP@ replacement parts and repair labor to correct defects in materials or workrnanshib.

FULLFIVE-YEAR WARRANTY

From Date of Purchase

FSP replacement parts and repair labor to correct defects in materials or workmanship in the sealed refrigeration system.

These parts are:

1. Compressor 4. Drier-Strainer

2. Evaporator 5. Connecting Tubing

3. Condenser

WHIRLPOOL WILL NOT PAY FOR

A sefvice calls to:

1. Correct the installation of the air conditioner.

2. Instruct you how to use the air conditioner.

3. Replace house fuses or correct house wiring.

4. Clean or replace air filter.

B. Pi up and delivery. This product is designed to be repaired in the home.

C. Damage to the air conditioner caused by accident, misuse, fire, flood, acts of God or use of pmhcts not approved by Whirlpool.

D. The removal and reinstallation of the air conditioner if it is installed in an overhead or other ineccessible location or not installed in accordance with published installation instructions.

Bewke under the full warranties must be provided by an authorized Whirfpoolsu service company.

WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL

DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so thii limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may alao have other rights which vary from state to state.

Gutside the United States, a different warranty may apply. For details, please contact your franchised

Whirlpod distributor or military exchange. lf you need servfce, first see the ‘Service and Assistance” section of this book. After checking ‘Service and As&tan& additional help can be found by calling our COOL-LINE@ service assistance telephone number, 1-8OOk-13Ol, from anywhere in the U.S.