Symmons S-9600TS-PLR-TRM Origins 1-Handle Wall-Mounted Tub/Shower Valve Trim Kit (Valve Not Included) Installation & Operation Instructions

Add to My manuals
8 Pages

advertisement

Symmons S-9600TS-PLR-TRM Origins 1-Handle Wall-Mounted Tub/Shower Valve Trim Kit (Valve Not Included) Installation & Operation Instructions | Manualzz

Origins

®

Origins Trim Series

Origins Trim Series with TA-10 Flow Control Spindle & T-12A Cap Assembly

Installation & Operation Instructions

Model Numbers

TRIM ONLY

S-9600-P-TRM

Shower Valve Trim

S-9600-PLR-TRM

Shower Valve Trim

S-9601-P-TRM

Shower Trim

S-9601-PLR-TRM

Shower Trim

S-9602-P-TRM

Tub/Shower Trim

S-9602-PLR-TRM

Tub/Shower Trim

S-9603-PLR-TRM

Hand Shower Trim

S-9604-PLR-TRM

Tub/Hand Shower Trim

S-9606-PLR-TRM

Tub/Shower/Hand Shower Trim

S-9608-PLR-TRM

Shower/Hand Shower Trim

TRIM, TA-10, T-12A

S9600PTRMTC

Shower Valve Trim

S9600PLRTRMTC

Shower Valve Trim

S9601PTRMTC

Shower Trim

S9601PLRTRMTC

Shower Trim

S9602PTRMTC

Tub/Shower Trim

S9602PLRTRMTC

Tub/Shower Trim

S9603PLRTRMTC

Hand Shower Trim

S9604PLRTRMTC

Tub/Hand Shower Trim

S9606PLRTRMTC

Tub/Shower/Hand Shower Trim

S9608PLRTRMTC

Shower/Hand Shower Trim

S-9600-P-TRM

S9600PTRMTC

S-9600-PLR-TRM

S9600PLRTRMTC

S-9601-P-TRM

S9601PTRMTC

S-9601-PLR-TRM

S9601PLRTRMTC

S-9602-P-TRM

S9602PTRMTC

S-9602-PLR-TRM

S9602PLRTRMTC

S-9603-PLR-TRM

S9603PLRTRMTC

S-9604-PLR-TRM

S9604PLRTRMTC

Compliance

• ASME A112.18.1/CSA B125.1

T-12A TA-10

Warranty

Limited Lifetime - to the original end purchaser in consumer/residential installations.

5 Years - for industrial/commercial installations.

Refer to www.symmons.com/warranty for complete warranty information.

Go to www.symmons.com/register to register your

Symmons product.

S-9606-PLR-TRM

S9606PLRTRMTC

S9608PLRTRM

S9608PLRTRMTC

1. Recommended Tools

FIGURE 1

Adjustable Wrench

2. Dimensions

FIGURE 2

Allen Wrench (3mm) Drill Phillips Screwdriver Safety Glasses Thread Seal Tape

JJ

II

EE

LL

FF

TT

E

F

G

H

I

J

A

B

C

D

K

L

X

Y

Z

T

U

V

W

P

Q

R

S

M

N

O

Measurements

6-3/8", 162 mm

3", 76 mm

Diverter Valve Hole Size

Min. Ø 3", 76 mm

Max. Ø 3-1/4", 83 mm

3 1/2", 89 mm

Male 1/2" NPT fitting must protrude 3/8" from finished wall

Ref. 10", 254 mm

Ref. 77", 1956 mm

Shower Valve Hole Size

Min. Ø 3", 76 mm

Max. Ø 4", 102 mm

2-7/8", 73 mm

Rough-in

2-3/8" ± 1/2", 60 mm ± 13 mm

Trim with tub spout:

Ref. 32", 813 mm

Trim without tub spout:

Ref. 42", 1067 mm

Male 1/2" NPT fitting must protrude 4" from finished wall

5-1/2", 140 mm

Ø 2-1/2", 64 mm

Ø 2-3/4", 70 mm

Ø 4-1/4", 108 mm

Ø 2-1/2", 64 mm

Ø 5-3/4", 146 mm

Ø 2-1/2", 64 mm

Ø 3-1/8", 79 mm

36", 914 mm

39", 991 mm

2-7/8", 73 mm

2-1/8", 54 mm

3-5/8", 92 mm

3-3/8", 86 mm

XX ZZ

Notes:

1) Valve body and piping not included and shown as reference only.

2) Plaster shield (p/n T-176) for dry wall, plaster or other type walls 1/2" or greater.

3) All dimensions measured from nominal rough-in (see J as reference).

4) Dimensions subject to change without notice.

2

3. Parts Breakdown (Model Numbers Ending in TRMTC)

LIMIT STOP

SCREW

2

Item

1

2

Replacement Parts

Description

Cap Assy.

Part Number

T-12A

Flow Control Spindle TA-10

PACKING

NUT

1

FIGURE 3

IMPORTANT: Model numbers ending in TRMTC coordinate with Temptrol pressure balancing valves ordered with Test Cap. The Test Cap is used to allow pressurization of system. Do not remove test cap from valve during wall construction, installation of valve or pressurization of system.

WARNINGS:

1. Test cap rated for pressure testing up to 200 psi maximum. DO NOT exceed 200 psi while pressure testing valve body.

2. Do not expose valve with test cap to heat for longer than 2 minutes when soldering copper tubing. Doing so may damage the internal components of the valve and will void the product warranty.

3. Ensure test cap is re-torqued to 30 lb-ft after soldering valve body.

4. Installation - Remove Test Cap (Model Numbers Ending in TRMTC)

Flow control spindle (TA-10) and cap assembly (T-12A) will come factory assembled for all model numbers ending in

TRMTC . When ready to remove Test Cap and install trim, follow the instructions below:

1) Check for leaks around the valve assembly and all pipe fittings.

2) Remove test cap from valve (FIGURE 4.1).

3) If system is dirty, flush valve.

4) Thread flow control spindle and cap assembly into valve body. Turn clockwise to secure to valve (FIGURE 4.2).

FIGURE 4.1

FIGURE 4.2

5. Installation - Adjust Packing Nut (Model Numbers Ending in TRMTC)

1) Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.

2) Place handle over flow control spindle.

3) Tighten packing nut for positive frictional resistance as handle is rotated from shut-off position across adjustment range.

6. Installation - Setting Limit Stop Screw (Model Numbers Ending in TRMTC)

The temperature limit stop screw limits valve handle from being turned to maximum position resulting in excessive hot water discharge temperatures.

WARNING: Failure to adjust limit stop screw properly may result in serious scalding.

1) Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.

2) Place handle on flow control spindle and open valve to maximum desired temperature.

3) Turn limit stop screw clockwise until it seats.

3

7. Parts Breakdown

FIGURE 7

C

A

D

B

H

E

G

E

F

F

J

N

P

I

I

O

K

D

EF-109*

*Order in-line vacuum breaker (EF-109) for hand shower systems without dual checks.

L

M

K

L

M

N

O

Item

A

B

C

D

E

F

G

H

J

I

P

Replacement Parts

Description

Showerhead

Shower Arm

Flange

Part Number

4-141

300S

'PLR' Handle

Dome Cover

Diverter Escutcheon

Screws

'P' Handle

RTS-063

T-19

96-66-DIV-ESC

Shower Escutcheon

Screws

Tub Spout

Hand Shower

Wall Elbow

Slide Mechanism

60" Hose

Diverter/Volume

Control Handle

RTS-061

Standard (P):

S-9600-P-ESC

Brass (P):

S-9600-P-B-ESC

Standard (PLR):

S-9600-PLR-ESC

Brass (PLR):

S-9600-PLR-B-ESC

060

ADACHS

40A

FP-SM6

RTS-045

Standard:

RTS-062

Brass:

RTS-062-B

Notes:

1) Append appropriate suffix for premium finish.

2) Append appropriate flow rate to showerhead or hand shower for low flow.

3) Apply a bead of silicone around the perimeter of all shower trim installed flush to the finished wall. Leave opening on bottom of escutcheons for weep hole.

4) Apply plumber tape to all threaded connections.

4

8. Installation - Shower Valve Trim

1) Place diverter/volume control handle into slot in shower escutcheon (FIGURE 8.1).

2) Secure large shower escutcheon to Temptrol pressure balancing valve using mounting screws. Guide handle into control port on valve body (FIGURE 8.2).

3) Install dome cover by turning clockwise (FIGURE 8.3).

4) A: Install 'P' handle to shower valve. Secure with

set screw. Install plug button (FIGURE 8.4).

B: Install 'PLR' handle to shower valve. Secure with set screw (FIGURE 8.4).

FIGURE 8.1

FIGURE 8.3

9. Installation - Diverter Valve Trim

1) Secure small diverter escutcheon to Symmons diverter valve using mounting screws (FIGURE 9.1).

2) Install dome cover by turning clockwise (FIGURE 9.2).

3) Install handle to diverter valve. Secure with set screw

(FIGURE 9.3).

FIGURE 9.1

FIGURE 9.3

FIGURE 8.2

FIGURE 8.4

A B

FIGURE 9.2

10. Installation - Showerhead & Tub Spout

1) Attach arm and flange to shower pipe. Turn clockwise to tighten (FIGURE 10.1).

2) Install showerhead to shower arm. Turn clockwise to tighten (FIGURE 10.2).

3) Install tub spout to stub out pipe. Turn clockwise to tighten (FIGURE 10.3).

FIGURE 10.1

FIGURE 10.3

FIGURE 10.2

5

11. Installation - Slide Bar Assembly

1) Remove slide bar ends from slide bar flanges. Using flanges as a guide, drill 1/8" pilot holes into studs or wood blocking. With slide bar in position, secure to wall using screws. Attach slide bar ends to bar flanges

(FIGURE 11.1).

2) Remove screw cap from slide mechanism (FIGURE 11.2).

3) Remove wand holder from slide mechanism

(FIGURE 11.3).

4) Remove lever handle from slide mechanism

(FIGURE 11.4).

5) Install slide mechanism components to slide bar following STEPS 11.2 - 11.4 in reverse. Flat edge on (N1) and (N2) must be aligned. Arrows on (N1) and (N3) identify bottom side (FIGURE 11.5).

Note: Adjust screw cap for ease of movement of slide assembly.

6) Press tabs on wall elbow flange. Install wall elbow to pipe fitting. Turn clockwise to secure (FIGURE 11.6).

7) Attach small end of hand shower hose to wall elbow.

Turn clockwise to tighten (FIGURE 11.7).

8) Attach large end of hand shower hose to hand shower wand. Turn clockwise to tighten (FIGURE 11.8).

FIGURE 11.1

3

1

FIGURE 11.2

4

2

FIGURE 11.5

N1

N3

SLIDE

LOCK

SLIDE

FIGURE 11.6

1

2

N2

FIGURE 11.3

FIGURE 11.7

FIGURE 11.4

FIGURE 11.8

6

12. Operation (Temperature Control)

1) Turn shower handle counterclockwise approximately 1/4 turn to put valve in cold position (FIGURE 12.1).

2) Turn shower handle counter- clockwise approximately 1/2 turn to put valve in warm position (FIGURE 12.2).

3) Turn shower handle counter- clockwise approximately 3/4 turn to put valve in hot position (FIGURE 12.3).

FIGURE 12.1

FIGURE 12.2

13. Operation (VersaFlex™ Diverter Control)

Turn diverter control handle clockwise to divert to tub spout or other Symmons accessory .

Turn diverter control handle counterclockwise to divert to shower or other Symmons accessory .

FIGURE 13.1

TUB/ACCESSORY SHOWER/ACCESSORY

14. Operation (Volume Control)

Turn volume control handle clockwise to increase volume.

Turn volume control handle counterclockwise to decrease volume.

FIGURE 14.1

DECREASE INCREASE

15. Operation (Dual Outlet Diverter Control)

Note: Additional handle positions for

same output are illustrated.

1) Cartridge is factory set to divert to function 1 (FIGURE 15.1).

2) Turn handle to position 2 to divert to function 2 (FIGURE 15.2).

3) Turn handle to position 3 to share functions 1 and 2 (FIGURE 15.3).

FIGURE 15.1

FIGURE 15.2

FIGURE 12.3

FIGURE 15.3

7

16. Troubleshooting Chart

Problem

Finish is spotting.

Cause

Elements in water supply may cause water staining on finish.

Solution

Clean finished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse with water.

WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.