Numatic NVR170 Owner Instructions
Add to my manuals
12 Pages
Numatic NVR170 is a vacuum cleaner intended for indoor use in the collection of dry materials. It is primarily used commercially, for example in hotels, schools, hospitals, factories, shops, and offices. The vacuum cleaner has a 7.2 L drum size and a cleaning range of 26.4 m. It weighs 8.0 Kg and has a sound pressure of ≤ 70 dB (A). The vacuum cleaner is Class II and has dimensions of 360 mm x 370 mm x 390 mm. It comes with a TriTex filter and HepaFlo bags.
advertisement
www.numatic.co.uk
GB
Original Instructions -
CAUTION, Read instructions before using the machine.
AS0
NVR170-11
(620w)
EVR170-11
(420w)
Kit AS0
Assembly
Start Power On Indicator Light
6
9
1
4
3
7 8 2
1
10
5
Cleaning
2
Tool tidy
Wand docking
Notes
.............................................................................................................
.............................................................................................................
.............................................................................................................
.............................................................................................................
.............................................................................................................
.............................................................................................................
.............................................................................................................
............................................................................................................
1 2
Fitting the Face
1
2
Removing the Face
1
7.2 L
2
26.4 m
3
8.0 Kg
1 2
Drum Size Cleaning Range
3
4
≤ 70 dB (A)
0.5 dB(A)
Weight
(Ready to work)
5
Class II
4
Sound Pressure (LpA)
Uncertainty (KpA)
5
Protection Class
6
Data
360 mm x 370 mm x 390 mm
6
Dimensions
Schematic Diagram
604165
604015
Replacement Parts
TriTex Filter
TriTex-Filter
HepaFlo Bags
NVM 1CH (Pack of 10) (170)
5
6
3
4
7
1
2
8
9
10
Voltage / Supply
Frequency
Rated Input Power
Weight (ready to work)
Company Name & Address
Model
Machine yr/wk Serial number
WEEE Logo
Protection Class 2 Symbol
CE Mark
1
2
3
7
Rating Label
4
5
6
PPE (personal protective equipment). That may be required for certain operations.
About your machine
8 9 10
Ear Protection Safety Footwear Head Protection Safety Gloves
Eye Protection Protective Clothing
Dust / Allergens
Protection
Hi Viz Jacket
NOTE: A risk assessment should be conducted to determine which PPE should be worn.
Caution Floor Sign
WEEE Legislation (Waste, Electrical and Electronic Equipment)
Vacuum cleaner, accessories and packaging should be sorted for environmentally - friendly recycling.
(Only for EU Countries)
Do not dispose of vacuum cleaner into household waste! According to the European Directive
2012/19/EU on waste electrical and electronic equipment and its incorporation into national law.
Vacuum cleaners that are no longer suitable for use must be separately collected and sent for recovery in an environmentally - friendly manner.
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or the
Numatic Technical helpline +44 (0)1460 269268
MAINTENANCE Daily
Keep the machine clean, including hoses and tubes.
Ensure the bag and filter are fitted.
Regularly examine the power cord.
Check dust bag frequently.
Check filters are clean.
Mains leads:
Safety Critical Components
H05-V2V2-F 10 m x 2 Core x 0.75 mm 2
GB
Information for DRY use Vacuum cleaners
WARNING
Read the instruction manual before using the machine.
Operators shall be adequately instructed on the use of their machine.
As with all electrical equipment, care and attention must be exercised at all times during use, in addition to ensuring that routine and preventative maintenance is carried out periodically to ensure safe operation.
Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render this equipment unsafe and the manufacturer can accept no responsibility in this respect.
Maintenance should only be carried out by a qualified person.
This machine is for DRY USE only and must not be stored outside or used in wet conditions.
The machine shall be disconnected from the mains by removing the plug from the supply socket during cleaning or maintenance and when replacing parts or converting the machine to another function.
This machine is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge.
This appliance is intended to be cleaned and maintained by an adult.
Children being supervised are not to play with the machine.
This machine is not a toy.
This machine is not suitable for picking up hazardous or explosive dust.
Contact your local distributor if you require a machine capable of performing these tasks.
CAUTION
Ensure that the filtration system fitted to the machine is suitable for the material being collected.
This vacuum cleaner is intended for indoor use in the collection of dry materials.
This machine should be stored indoors only.
NOTES
The primary use for this machine is commercial, for example in hotels, schools, hospitals, factories, shops and offices.
This product complies with the requirements of clause 20 of IEC/EN 60335-2-69 Stability and Mechanical
Hazards.
This vacuum cleaner is fitted with a thermal protection device. If the vacuum cleaner stops working, remove the plug from the wall before investigating where the fault lies.
If the vacuum cleaner has a blockage, switch off, remove the plug from the socket, inspect the floor tool, tubes and hose for debris. If the floor tool, tubes and hose are clear, replace the dust bag and clean the filter.
The vacuum cleaner should be inspected after use for damage.
The vacuum cleaner should be stored in a dry place.
When moving from one place to another, consider the weight of the machine.
•
Keep your machine clean including hoses and tubes.
Change dust bag frequently.
Keep filters clean.
•
•
Keep diffuser filter (where fitted) clean.
Use filter bags, they will enhance performance and help keep machine clean.
Use a Numatic Original filter bag under fine dust conditions.
Keep hoses and tubes clear.
•
•
Replace any worn or damaged parts immediately.
Only use the socket outlet on the machine for purposes specified in the instructions.
Only use the brushes provided with the machine. The use of other brushes may impair safety.
Regularly examine the power cord. If damage is found such as cracking or ageing the power cord must be
• replaced by a qualified person.
Only replace the power cord with the correct Numatic approved replacement part.
•
Pull on the cable to unplug the machine from the power supply.
Use to suck up hot ashes or lighted cigarette ends.
Use steam cleaners or pressure washers to clean the machine or use in the rain.
•
Immerse in water for cleaning.
Attempt machine maintenance or cleaning unless the power supply plug has been removed from the
• supply outlet.
Use in wet environments or to collect wet materials.
Under any circumstances place foreign objects including (but not limited to) air fresheners, air freshener capsules or scented beads of any type into the top filter of the machine. Doing so can be dangerous and risk damage to the machine and may invalidate the machine warranty.
Numatic International Limited warrant to the original purchaser that its products are free of defects in both material or workmanship for the period shown below:-
Homecare and Cleancare Vacuum cleaners........................................ 2 Years
Rotary Floor Machines.......................................................................... 2 Years
Twintec Auto Scrubber Dryer................................................................ 1 Year
Mopping, Compacts, Combi and Servocare Products......................... 1 Year
Individual Accessories and Spare Parts........................................... 6 Months
Note: This warranty expressly excludes consumable parts such as carbon brushes, floor brushes, mops, batteries etc, that are considered replaceable from time to time during the normal working life of the machine.
A. The warranty period commences from the date the goods are purchased.
B. All warranty claims must be processed through the Dealer from whom the equipment was purchased. The Dealer will co-operate with the purchaser
C. If the original Dealer is no longer able to fulfil his obligations please contact
Numatic International Limited with full details of the claim and proof of purchase so that this may be processed without delay.
D. Any warranty claim can only relate to the specific part that is proven to be at fault and for which a replacement will be supplied but cannot be extended to constitute a claim against the complete machine.
E. Numatic International will supply the Dealer with any warranty parts required, subject to the claim being validated, after return of the faulty items in accordance with Numatic International Limited’s General Conditions of Sale.
F. Claims will not be accepted if they are the result of fair wear and tear, misuse or abuse of any kind.
G. No replacement will be given unless the appropriate evidence of the validity of the claim has been provided to the satisfaction of Numatic International Limited.
H. Numatic International Limited reserve the right to charge for any unnecessary work carried out as a result of an invalid claim.
I. No variation to this warranty may be made or implied by any member of Numatic
International Limited or its Dealers unless such variation is in writing and authorised by the Company.
Numatic International Limited. Chard, Somerset, TA20 2GB
Telephone: 01460 68600 Fax: 01460 68458
© Numatic International Limited 2016
233058 08/16 (A03)
Numatic International Limited.
Chard, Somerset TA20 2GB ENGLAND
Tel: 01460 68600 www.numatic.co.uk
Numatic International GmbH. Fränkische Straße 15–19
D-30455 Hannover, DEUTSCHLAND
Tel: 05 11 98 42 16 0 www.numatic.de
Numatic International SAS. 13 / 17 rue du Valengelier
77500 CHELLES, FRANCE
Tel: 01 64 72 61 61 www.numatic.fr
BeNeLux Distribution, Numatic International BV
Postbus 101, 2400 AC Alphen aan den Rijn, NEDERLAND
Tel: 0172 467 999 www.numatic.nl
Numatic International (Pty.) Ltd.
16th & Pharmaceutical Roads, Midrand, Gauteng,
SOUTH AFRICA 1685
Tel: 0861 686 284 www.numatic.co.za
Numatic International Schweiz AG.
Sihlbruggstrasse 142, 6340 Baar. SCHWEIZ
Tel: 0041 (0) 41 76 80 76 - 0 www.numatic.ch
Numatic International ULDA. Centro de Negócios da Maia,
Rua Albino José Domingues, 581, 4470 – 034 Maia PORTUGAL
Tel: +351 220 047 700 www.numatic.pt
Numatic International SLU. C/ La Forja, 41, 08840 Viladecans
(Barcelona), Spain
Tel: +34 93 647 22 22 www.numatic.es
Specification subject to change without prior notice www.numatic.co.uk © Numatic International Limited