TempStar® HH/GPX

Models

TempStar® HH/GPX

Project

Item

Quantity

CSI Section 11400

Approval

Date

Standard Features

• Multi-cycle timer (Extra Heavy,

Heavy, Medium, Normal)

• Built-in pressure regulator and

gauge

• Extended 15 second high tempera-

ture rinse provides superior cover-

age and rapid drying

• 20-3/4" wide X 27" high (527 mm X

686 mm) opening accommodates

18" X 26" (457 mm X 660 mm) sheet

pans and 60 quart mixing bowls

• Auto-fill / auto-start

• Safety door switch

• External gas booster heater

- Capable of minimum 70˚F (21˚C)

degree temperature rise

- Recirculates water through stain-

less steel coils in wash tank to

maintain 150˚F (66˚C) degree

minimum temperature

• Hi-limit thermostat and low water

protection

• Top mounted controls for ease of

installation

• Unique lower counter-rotating

wash arms and upper wash arm

provide optimum spray coverage

and superior cleaning action

• Unique split-door design for insta-

llations with low ceiling heights

• Large scrap tray

• Self-draining stainless steel pump

• Detergent/rinse additive signal

connection fuse box

• Delime/manual wash switch

• Adjustable bullet feet

• Uses standard 20” X 20”

(508 mm X 508 mm) racks

• Front dress panel

Mandatory Specs

Specify how far booster will be placed from unit

Specify altitude for proper booster size

Options

Water Hammer Arrestor

Flanged Feet

Drain Quench System

Scaltrol

False Panel

Safety Door Interlock

Accessories

36-Compartment Rack

4-1/8” tall (105 mm)

5-5/8” tall (143 mm)

7” tall (178 mm)

Combination Rack

Peg Rack

Sheet Pan Rack - for 18” X 26”

(457 mm X 660 mm) baking pans

Specifications

Uses 1.36 gallons (5 liters) of 180˚F (82˚C) water per rack

Total automatic normal cycle - 62 seconds

53 racks per hour normal cycle

2 hp wash pump motor

Single point connections for all utilities

Built-in water pressure regulator and pressure gauge

Field convertible from straight through to corner and vice versa

Heavy duty stainless steel construction

SHIPPING ADDRESS

6209 North U.S. Highway 25E

Gray, KY 40734

MAILING ADDRESS

P.O. Box 1060

Barbourville, KY 40906

Tel: 1-888-800-5672

Fax: 606-523-1799 [email protected]

www.jacksonmsc.com

4 [102mm]

4 [102mm]

8634 [2202mm]

73 [1856mm]

C

25 [637mm]

17 [432mm]

27 [687mm]

LEGEND

A - DRAIN 1 1/2” NPT

B - WATER INLET 1/2” NPT

C - ELECTRICAL CONNECTION

D - OUTLET TO BOOSTER

HEATER 3/4” NPT

E - INLET FROM BOOSTER

HEATER 3/4” NPT

All vertical dimensions are +/- 1/2" due to adjustable bullet feet.

2514 [639mm]

3 [79mm]

C

3 [77mm]

C

2514 [642mm]

32 [813mm]

734 [194mm]

E

1 [25mm]

A 34 [861mm]

1134 [298mm]

312 [92mm]

1034 [274mm]

34 [866mm]

D B

18 [456mm]

1634 [426mm]

A

5 [126mm]

4

[387mm]

E

1134 [298mm]

MODEL NO.

TempStar® HH/GPX

MACHINE DIMENSIONS

HEIGHT WIDTH

76-3/4”

(1949 mm)

25-1/4”

(641 mm)

DEPTH

25-1/4”

(641 mm)

DRAIN

HEIGHT

11-3/4”

(298 mm)

SHIPPING INFORMATION

WEIGHT CLASS CUBE

420 lbs

(191 kg)

92.5

74.9

cu. ft.

HEIGHT

79”

(2007 mm)

WIDTH

33”

(838 mm)

DEPTH

49”

(1245 mm)

DIMENSION REQUIREMENTS

Minimum Ceiling Height (Recommended)

Wall Clearance (Minimum)

Standard Table Height

Inside Clearance

OPERATING CAPACITY

Racks per Hour

Normal

53

OPERATING CYCLE (seconds) Wash

Normal 45

Medium

Heavy

Extra Heavy

103

163

283

Medium

28

Rinse

15

15

15

15

Heavy

19

Dwell

2

2

2

2

88” (2 meters)

4” (102 mm)

34” (864 mm)

27” (686 mm)

Extra Heavy

11

Total Cycle

62

120

180

300

OPERATING TEMPERATURES

Wash (Minimum)

Rinse (Minimum)

APPROXIMATE TOTAL LOAD AMPS

150˚F (66 °C)

180˚F (82 °C)

115V/60HZ/1PH

208V/60HZ/1PH

208V/60HZ/3PH

230V/60HZ/1PH

230V/60HZ/3PH

AMPS

25

13

13

13

13

GAS REQUIREMENTS

Natural Gas (Inches-water column)

LP Propane Gas (Inches-water column)

Gas Booster Capacity (BTU)

Input

Output

WATER REQUIREMENTS

Inlet Tempterature

40˚F / (4˚C) Rise

70˚F / (21˚C) Rise

Gallons per Hour

Waterline Size IPS (Minimum-inches)

Drainline Size IPS (Minimum-Inches)

Flow Pressure (PSI)

Wash Tank Capacity

Booster Tank Capacity

Pump Capacity (GPM)

WASH PUMP MOTOR

Wash Pump Motor

HOW TO SPECIFY: TempStar® HH/GPX

Maximum

10.5 (267 mm)

13.0 (330 mm)

Minimum

5.0 (127 mm)

11.0 (292 mm)

105,000

84,800

140˚F (60˚C)

110˚F (43˚C)

72.1 gal (273 L)

3/4”

1-1/2”

15-25

8 gal (30 L )

3 gal (11 L )

73 gal (276 L )

2 hp

SHIPPING ADDRESS

6209 North U.S. Highway 25E

Gray, KY 40734

MAILING ADDRESS

P.O. Box 1060

Barbourville, KY 40906

Tel: 1-888-800-5672

Fax: 606-523-1799 [email protected]

www.jacksonmsc.com

07610-002-66-62 (02/10)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement