TempStar™ HH/GPX

Models

TempStar™ HH/GPX

Project

Item

Quantity

CSI Section 11400

Approval

Date

Standard Features

Multi-cycle timer (Extra Heavy,

Heavy, Medium, Normal)

Built-in pressure regulator and gauge

Extended 15 second high temperature rinse provides superior coverage and rapid drying

20 3/4” (527 mm) wide X 27” (686 mm) high opening accommodates

18” (457 mm) X 26” (660 mm) sheet pans and 60 quart mixing bowls

Auto-fill / auto-start

Safety door switch

External gas booster heater

- Capable of minimum 70˚F

(21˚C) degree temperature rise

- Recirculates water through stainless steel coils in wash tank to maintain 150˚F (66˚C) degree minimum temperature

Hi-limit thermostat and low water protection

Top mounted controls for ease of installation

Unique lower counter-rotating wash arms and upper wash arm provide optimum spray coverage and superior cleaning action

Unique split-door design for installations with low ceiling heights

Large scrap tray

Self-draining stainless steel pump

Detergent/rinse additive signal connection fuse box

Delime/manual wash switch

Adjustable bullet feet

Uses standard 20” X 20”

(508 mm X 508 mm) racks

Front dress panel

Mandatory Specs

Specify incoming water

temperature

Specify how far booster

will be placed from unit

Specify altitude for

proper booster size

Optional Features

Water hammer arrestor

Flanged feet

Drain quench system

Scaltrol

Accessories

36” (914 mm) compartment

rack 4 1/6” (4 mm) tall

36” (914 mm) compartment

rack 5 5/8” (16 mm) tall

36” (914 mm) compartment

rack 7” (178 mm) tall

Combination rack

Peg rack

Sheet pan rack 18” X 26” /

(457 mm X 660 mm) baking

pans

Specifications

U s e s 1 . 3 6 g a l l o n s ( 5 l i t e r s ) o f 1 8 0 ˚F

(82˚C) w a t e r p e r r a c k

T o t a l a u t o m a t i c n o r m a l c y c l e - 6 2 s e c o n d s

5 3 r a c k s p e r h o u r n o r m a l c y c l e

2 H P W a s h P u m p M o t o r

Highway 25E

P. O. Box 1060

Barbourville, KY 40906

Tel: 606-523-9795

Tel: 1-888-800-5672

Fax: 606-523-9196

E-mail: [email protected]

S i n g l e P o i n t c o n n e c t i o n s f o r a l l u t i l i t i e s

B u i l t - i n w a t e r p r e s s u r e r e g u l a t o r a n d p r e s s u r e g a u g e

F i e l d c o n v e r t i b l e f r o m s t r a i g h t t h r o u g h t o c o r n e r o p e r a t i o n s

H e a v y d u t y s t a i n l e s s s t e e l c o n s t r u c t i o n www.jacksonmsc.com

07610-002-66-62 (09/07)

4 [102mm]

4 [102mm]

8634 [2202mm]

73 [1856mm]

C

25 [637mm]

17 [432mm]

27 [687mm]

LEGEND

A - DRAIN 1 1/2” NPT

B - WATER INLET 1/2” NPT

C - ELECTRICAL CONNECTION

D - OUTLET TO BOOSTER

HEATER 3/4” NPT

E - INLET FROM BOOSTER

HEATER 3/4” NPT

All vertical dimensions are +/- 1/2" due to adjustable bullet feet.

2514 [639mm]

3 [79mm]

C

3 [77mm]

C

2514 [642mm]

32 [813mm]

DIMENSIONS--STANDARD MODEL moDel no.

heIght

SIze wIDth

734 [194mm]

E

1 [25mm]

DePth

DrAIn heIght

34 [866mm]

D B

A 34 [861mm]

18 [456mm]

1134 [298mm]

312 [92mm]

1034 [274mm]

ShIPPIng Info weIght ClASS Cube

1634 [426mm]

A

E

5 [126mm]

1514 [387mm] heIght

1134 [298mm]

DImenSIonS wIDth DePth

TempStar™ HH/GPX

76-3/4”

(1949 mm)

DIMENSION REQUIREMENTS

Minimum Ceiling Height (Recommended)

Wall Clearance (Minimum)

Standard Table Height

Inside Clearance

25-1/4”

(641 mm)

25-1/4”

(641 mm)

11-3/4”

(298 mm)

420 lbs

(191 kg)

88” / (2 meters)

4” / (102 mm)

34” / (864 mm)

17-1/4”/ (438 mm)

92.5

71.4

cu. ft.

85”

(2159 mm)

44”

(1118 mm)

33”

(838 mm)

GAS REQUIREMENTS

Natural Gas (Inches-water column)

Maximum

10.5 / (267 mm)

Minimum

5.0 / (127 mm)

LP Propane Gas (Inches-water column) 13.0 / (330 mm) 11.0 / 292 mm)

Gas Booster Capacity (BTU)

Input

Output

105,000

84,800

OPERATING CAPACITY

Racks per Hour

OPERATING CYCLE (sec)

Normal

Medium

Heavy

Extra Heavy

OPERATING TEMPERATURES

Wash (Minimum)

Normal

53

Wash

45

103

163

283

Rinse (Minimum)

WASH PUMP MOTOR

Wash Pump Motor Horsepower

Medium

28

Rinse

15

15

15

15

Heavy

19

Dwell

2

2

2

2

Extra Heavy

11

Total Cycle

62

120

180

300

150˚F / (66˚C)

180˚F / (82˚C)

2 HP

WATER REQUIREMENTS

Inlet Tempterature

40˚F / (4˚C) Rise

70˚F / (21˚C) Rise

Gallons per hour

Waterline Size IPS (Minimum-inches)

Drainline Size IPS (Minimum-Inches)

Flow Pressure (PSI)

Tank Capacity

Wash Tank

Booster Tank

Pump Capacity (GPM)

APPROXIMATE TOTAL LOAD AMPS

140˚F / (82˚C)

110˚F / (60˚C)

72.1 / 273 Ltr.

3/4

1-1/2

15-25

8 Gal. / (30 ltr)

3 Gal. / (11 ltr)

73 Gal / (276 ltr)

How To Specify - TempStar™ HH/GPX

115V/60HZ/1PH

208V/60HZ/1PH

230V/60HZ/3PH

230V/60HZ/1PH

230V/60HZ/3PH

AMPS

25

13

13

13

13

Highway 25E

P. O. Box 1060

Tel: 606-523-9795

Tel: 1-888-800-5672 www.jacksonmsc.com

07610-002-66-62 (09/07)

Barbourville, KY 40906 Fax: 606-523-9196

E-mail: [email protected]

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement