CASSETTE AIR CONDITIONER

Operation Manual

AB142ACNBC

AU142AANBC

(HBU-14CM03/R1)

Please read this operation manual before using the air conditioner.

Please keep this manual carefully and safely.

No.0010577033 A

051101*********

Contents

Cautions ...........................................................................................

1-2

Main Points of Operation..................................................................

3-4

Part Name .......................................................................................

5

Remote Controller Functions........................................................

6-13

Safety Precautions.......................................................................

14-15

Maintenance .....................................................................................

16

Troubleshooting ...........................................................................

17-19

When Trouble Happens ...................................................................

20

Customer Need-to-know .................................................................

21

Installation Tools ..............................................................................

22

Installation Procedures ................................................................

23-30

Installation Procedures,Check and Test Run ....................................

31

Cautions

Disposal of the old air conditioner

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, antipollution method of disposal.

Disposal of the packaging of your new air conditioner

All the packaging materials in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

Safety Instructions and Warnings

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to t h e a s s e m b l y, o p e r a t i o n a n d maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before opening inlet grill.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

1

********

Cautions

All electrical repairs must be carried The power cable should be H05RN-F 3G 2.5mm.

out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.

5. The wiring method should be in line with the local standard.All the cables shall have got the European authentication certificate.

6.

The air breaker should be all-pole switch.

and the distance between it's two

Do not damage any parts of the air conditioner that carry refrigerant by connecters should no less than 3mm.

7. Air conditioner must use special power supply piercing or perforating the air conditioner's tubes with sharp or system (above 20A), and qualified electrician makes wiring and fixing according to wiring pointed items, crushing or twisting any tubes, or scraping the coatings off the regulations specified in national standard.

8. In socket, exactly distinguish earth wire with surfaces. If the refrigerant spurts out and gets into eyes, it may result in neutral wire and it is wrong to connect them together.

serious eye injuries.

Do not obstruct or cover the

9. A leakage breaker must be installed.

10. Connection method is Y-connection .If the ventilation grille of the air conditioner.

Do not put fingers or any other things power cord is damaged, it must be replaced by professional people of manufacturer or its into the inlet/outlet and swing louver.

maintenance department or similar to avoid

Do not allow children to play with the dangers.

air conditioner. In no case should

11. The air breaker and the power switch should children be allowed to sit on the installed the conveniently reachable place for outdoor unit.

user.

Specifications

Attention:

The refrigerating circuit is leak-proof.

As a result of poor conditions of the electrical

The machine is adaptive in following

MAINS, shortly voltage drops can appear situation

1. Applicable ambient temperature range: when starting the EQUIPMENT. This can influence other equipment (et.Blinking of a

Maximum: D.B / W.B

Indoor

32 C/ 23 C lamp). If the MAIN-IMPEDANCE Zmax< 0.

Minimum: D.B / 18 C/ 14 C

Cooling 4624277HM, such disturbance are not

Maximum:

Outdoor

D.B

43 C/ 26 C expected. In case of need , you may contact

Minimum: D.B

15 C your local supply authority for further

2. If the supply cord is damaged, it must be information.

replaced by the manufacturer or its service

Other Instructions agent or a similar qualified person.

Attention:

3. If the fuse on PC board is broken please

1. The waste battery shall be disposed properly.When

change it with the type of T 3.15A /250VAC.

throw away the waste batteries, please perform in

4.

Use copper wire only. The connecting cable accordance with the local regulation.

should be H05RN-F4G(3X2.5+1X0.75)mm

2

2. The indoor unit installation height is at least 2.5m.

certificate.

*

2

Main Points of Operation

Operation of Air Conditioner

When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode.

3-minute Protection Function

If you restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect the machine.

Variation of Fan Speed

If fan speed in auto mode, it will automatically lower when the room temperature close to the setting temperature in cooling mode.

In heating mode,the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops.

In Dry mode,fan speed will be automatically varied.

Remote Control:

There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a faraway place.

3

Main Points of Operation

Power Failure Compensation(to be applied for a necessary situation):

After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again.

Setting Method: When the remote controller is on (excluding timer mode and fan mode),press

the ìsleepingî button on the remote controller 10 times within 5 seconds,and

after the buzzer rings 4 times,the air conditioner will enter the state of power

failure compenstation.

Cancel Method:Press the ìsleepingî button on the remote controller 10 times within 5 seconds,

and after the buzzer rings 2 timer,the power failure compensation mode will be

cancelled.

Note: When a power failure suddenly occurs during the air conditioner si working after the

power after the power failure compensationis set,if the air conditioner will not be used

for a long time, please cut off the power supply to prevent its operation from being res-

umed after the power is supplied again, or press the ì Switch On/Off î button after the

power comes again.

4

Part Name

Indoor unit

Swing louver

(Air flow direction can be adjusted by using the SWING button on the remote controller)

Operation Panel

Air Inlet Grille

Air Filter

(Inside of the Inlet Grille)

Operating Control Panel

1

COMP TIMER OPER POWER

2 3 4 5 6

2

3

1

4

5

6

Remote receiver

Compressor Lamp

TIMER Lamp

OPERATION Lamp

Power Lamp

Emergency switch

Outdoor unit

Air inlet

Connecting piping and electrical wiring

Drain hose

Air outlet

5

Remote Controller Functions

2

3

4

5

6

7

8

23

24

25

26

27

28

29

30

31

1

Remote controller

AUTO

ON OFF

C

SWING

TEMP

ON

OFF

FAN

MODE

CLOCK SET

TIMER

LOCK RESET

SLEEP

22

21

20

19

18

17

16

15

14

13

12

11

10

9

1.TEMP Setting Button

(Used to set temperature, setting ranges:

16 C to 30 C)

2.SWING Button

Press once auto swing, press again the swing louver fixed on the present swing position.

3.Power ON/OFF Button (used for unit

start and stop)

After power on, the LCD of remote controller will display the previous operation state (except for TIMER,SLEEP and SW-

ING state).

4.Operation MODE

Used to select operation mode.

Every time press MODE button,operation mode changes according ot hte following order:

AUTO COOL DRY FAN

5.CLOCK Button

Used to set correct time.

6.TIMER Button

Used to select TIMER mode:TIMER ON,TIMER

OFF, TIMER ON/OFF.

(Note: if time of TIMER ON is the same as TIMER

OFF,TIMER ON/OFF cannot be set)

7.LOCK Button

Used to lock operation button and LCD display contents: after press this button, other button are out of function, lock state display appears; press again,cancel lock state and lock state display disappeared.

8.RESET Button

Used to sharp article press this button can reset the remote controller back to normal condition when it in malfunction state.

9.Battery Loaded Indication

10.HOUR Adjustment

Used to set clock and timer setting

11.SLEEP Button

(The clock must be corrected before set sleep function)

Used to set sleep mode.

12.SET Button

Used to confirm TIMER and CLOCK settings.

13.FAN Button

Used to select fan speed:LOW,MID,HIGH,AUTO.

NOTE: 1.Single cooling air conditioner does not have the displays and functions related to heating.

2.This kind of unit does not have the following related functions and displays: 15 18 19

21 22 23 24 26 30

6

Remote Controller Functions

14.TIMER OFF Display

15.HUMIDIFICATION Display

16.TEMPERATURE Display

17.LOCK State Display

18.BATTERY Energy Display

Display when in low battery to remind customer to change the battery.

19.STRONG/QUITE Run Display

20.SIGNAL SENDING Display

21.NEW AIR Display

22.ELECTRICAL HEATING Display

23.HEALTH Display

Display when healthy run function is set.

24.SLEEP State Display

25.Operation MODE Display

AUTO RUN COOL RUN DRY RUN

FAN RUN

When electronic-strated type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter.

Loading of the battery (load the batteries as illustrated)

Remove the battery cover

First slightly press the position marked with and push down the cover,then as shown in the figure:holding the upper part of the remote controller with the left hand and the right hand slightly grasps the battery box cover and forces on the arrow direction to remove the cover.

26.COMFORTABLE RUN Display

27.FAN SPEED Display

28.AUTO SWING Display

29.TIMER Display

30.FILTER Display

31.TIMER ON Display

LO

MID

HI

AUTO

AUTO

Remote Controllerí Operation

When in use, put the signal transmission head directly to the receiver hole on the indoor unit

The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.

Donít throw the controller,prevent it from being damaged.

Load the battery

Be sure that the loading is in line with the ì + î ì - î pole request as illustrated on the botton of the box.

Put on the cover again

Installing the cover is opposite to removing it

Confirmation indicator

If no indication after press ON/OFF button,reload the batteries.

Note:

Use two new same-typed batteries when loading.

If the remote controller canít run normally during operation ,please remove the batteries and reload them few minutes later that will be ok

If the display of remote controller is faded(sometimes run abnormally),which indicates no battery,so please change the batteries

Hint:

Remove the batteries in case unit will not be in usage for a long period.if there is any display after taking-out just need to press reset button with a sharp article.

When throw away the waste batteries, please perform in accordance with the local regulation.

When throw away the waste batteries, please perform in accordance with the local regulation.

Clock Set

When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:

1.Press CLOCK button,clock indication of ì AM ì or ìPMî flashes.

2.Press or to set correct time,each press will increase or decrease

1 min. If the button is kept pressed, time will increase or decrease quickly.

3.After time setting is confirmed,press ìSETî , AM or PM stop flashing,

while clock starts working.

Note:AM means morning and PM means afternoon.

MODE

CLOCK

1

TIMER

SET

2

SLEEP

3

LOCK RESET

7

Remote Controller Functions

Fan Operation

1.Unit start

Press ON/OFF button, unit starts.

Previous operation status appears on LCD (except for

TIMER ,SLEEP, and SWING setting).

2.Select operation mode

Press MODE button. For each press,operation mode changes as follows:

AUTO COOL DRY FAN

Then select FAN

3. Adjust fan speed

Press FAN button.For each press,fan speed changes as follows:

TEMP

SWING

4

ON

OFF

1

FAN

3

2

MODE

CLOCK SET

TIMER

LOCK RESET

SLEEP

LOW MID HIGH

Air conditioner will run at the selected fan speed.

When in AUTO mode,unit will adjust fan speed according to room temperature automatically.

4. Unit stop

Press ON/OFF button,unit stops.

About FAN Operation

FAN operation refers that the air conditioner only run

FAN,no COOL operation,and in this status the unit canít operate AUTO FAN as well no temperature settings.

8

Remote Controller Functions

AUTO run, COOL , DRY Operation

C

1. Unit start

Press ON/OFF button,unit starts.

Previous operation status appears on LCD (except for

TIMER,SLEEP and SWING setting)

2.Select operation mode

Press MODE button. For each press,operation mode changes as follows:

3

SWING

5

TEMP

ON

OFF

1

FAN

4

3

2

MODE

CLOCK SET

TIMER

LOCK

RESET

SLEEP

AUTO COOL DRY FAN

Then select AUTO run or select COOL operation or select DRY operation

3.Temperature setting

Press TEMP button.

Every time the button is pressed, temp. setting increases

1 C, if the button is kept pressed, temp. setting will increase quickly.

Every time the button is pressed, temp. setting decreases

1 C, if the button is kept pressed, temp. setting will decrease quickly.

Set proper temperature

4.Adjust FAN button

Press FAN button .For each press, fan speed changes as follows:

AUTO

COOL operation starts when room temp.is

higher than temp.

setting.

Ultra-low air flow

Temp. setting +2 C

Temp.setting

On reaching temp.setting

+2 C, unit will run in mild

DRY mode.

AUTO LOW MID HIGH

Air conditioner will run at the selected fan speed.

5. Unit stop

Press ON/OFF button,unit stops.

In ATUO mode,the temperature setting is not displayed on LCD.In this mode,during running air conditioner will select COOL ,HEAT or FAN mode automatically according to the room temperature.

In DRY mode,when room temperature becomes 2 C higher than temperature setting, unit will run intermittently at LOW speed regardless of FAN setting,When room temperature is lower than temperature setting,unit will only run in FAN mode.

9

Remote Controller Functions

Air flow direction adjust

AUTO SWING AUTO SWING

Press SWING button.

Up and down airflow vary upwards and downwards.Left and right airflow vary left and right sides.

When the automatic swing louver moves to the proper angle,press SWING button can fix the airflow direction.

Always use SWING button on the remote controller to adjust louver or flaps because adjusting by hand result in air conditioner running abnormally.

AUTO

C

In COOL or DRY mode, the louver is not permitted to be in downwards position for a long time because the water vapor close to the grille may be condensed and the water may drop from the air conditioner.

SWING

TEMP

ON

OFF

FAN

MODE

CLOCK

TIMER

LOCK

SET

RESET

SLEEP

Please carefully set temperature when infants, children,old people or patients use the air conditioner.

In case of great humidity ,if the vertical flaps all are towards left or right,the louver will drop water.

Donít pull louver directly by hand which will make it work abnormally.If the louver work abnormally,stop unit,restart and adjust it by remote controller.

After unit stops:

Displays on the LCD disappear.

All indicators on the indoor unit go out.

Swing louver automatically closes .

Hints:

As cold airflows downward in COOL mode,adjusting airflow horizontally will be much more helpful for a better air circulation

Be careful not to catch a cold when cold air blows downward directly.

10

Remote Controller Functions

Sleep Function

Before going to bed you can press down the SLEEP button and the air conditioner will run by the comfortable sleeping mode to make you sleep more comfortable.

Before use this function, the clock must be corrected.

Usage of SLEEP function

After unit start,first by running mode and then press SLEEP button once.Mark the air conditioner have the previous-set sleep time(first power-on or after carrying out sleep function is 1h),the sleep symbol will appear. Press time button / , you can choose the time in 1~8 hours.Each time the button is pressed the time increases/decreases 1 hour and ì xh î appears in the humidity setting part ,ì OFF î appears in ì TIMER OFF î display part and the sleep symbol disappears.

Operation Mode

1.In COOL, DRY mode

One hour after sleeping operation start, the temp.

is 1 C higher than the setting one. After another hour the temp. rises 1 C and then run continuously for another 6 hrs and then close. The actual temp.

is higher than the setting one which is to prevent from being too cool to your sleep.

2.In AUTO mode.

The air conditioner will run in corresponding sleep operation according to the automatically selected operation mode.

3.In FAN run

Canít use SLEEP function.

SLEEP RUN BEGINS SLEEP RUN STOPS about 6 hrs

1 hrs increase 1 C increase 1 C

SETTING T SHUT DOWN

In COOL,DRY mode

Note:

After setting SLEEP function ,it is forbidden to calibrate clock.

If the set sleep-time does not reach 8 hours, unit will stop operation automatically after set time is complete.

Set ì TIMER OFF îIn COOL,DRY mode function first, then set SLEEP, unit will perform sleep function.

After set SLEEP function, the TIMER function cannot be set.

Set ì TIMER ON îIn COOL,DRY mode function first,then set SLEEP, the sleep function can only be set before TIMER ON time.

After setting SLEEP function,press CLOCK button to show the time; press

TEMP button to show the temperature setting; press again to change the temperature.

OFF

SWING

TEMP

ON

OFF FAN

MODE

CLOCK

TIMER

LOCK

SET

RESET

SLEEP

11

Remote Controller Functions

Timer ON/OFF Function

Set clock correctly before starting TIMER operation

1.Unit start

After unit starts ,select your desired operation mode(operation mode will be displayed on LCD)

2.TIMER mode selection

Press TIMER button on the remote controller to change TIMER mode.Every time the button is pressed,display of TIMER mode changes as follows:

ON OFF ON OFF

AM 12:00

PM

12:00 AM 12:00

PM

12:00

TIMER ON TIMER OFF TIMER ON-OFF blank

ON

C

Then select TIMER mode as needed (TIMER ON or TIMER OFF).

SWING

TEMP

ON

OFF

1

FAN

MODE

CLOCK

2

TIMER

LOCK

SET

3 4

SLEEP

RESET

3.TIMER setting (press time adjust button)

Every time the button is pressed , time increases 10 minutes.

If the button is kept pressed ,time will change quickly.

Every time the button is pressed , time decreases 10 minutes.

If the button is kept pressed ,time will change quickly.

It can be adjusted within 24 hours at will.

4.Confirm setting

After set correct time,press SET button to confirm time. And now

ON

Time displayed: unit starts or stops at X hour X min (TIMER ON or TIMER OFF)

5.Cancel TIMER mode

Just press TIMER button several times until TIMER mode disappears

Hints:

After replacing batteries or a power failure happens,TIMER setting should be reset.

Remote controller possesses memory function,when use TIMER mode next time,just press SET button after mode selection if timer setting is the same as previous one.

Note:

After setting TIMER function,the remote controller displays TIMER time.If you want to see clock time, just press CLOCK button once it will display clock time (continuously press twice,you can adjust clock, see page 6 for details), and 5 seconds later it will back to TIMER time.

12

Remote Controller Functions

Timer ON-OFF Function

Set clock correctly before starting TIMER operation

1.Unit start

After unit start ,select your desired operation mode(operation mode will be displayed on LCD)

2.TIMER mode selection

Press TIMER button on the remote controller to change TIMER mode.Every time the button is pressed,display of TIMER mode changes as follows:

ON OFF ON OFF

AM 12:00

PM

12:00 AM 12:00

PM

12:00

TIMER ON TIMER OFF TIMER ON-OFF blank

OFF

C

ON Then select TIMER ON-OFF mode.

ON will flash.

SWING

TEMP

ON

OFF

1

FAN

MODE

CLOCK

2

4

TIMER

5

SET

3 6

SLEEP

RESET

3.Time setting for TIMER ON

Press time button

Every time the button is pressed , time increases 10 minutes.

If the button is kept pressed ,time will change quickly.

Every time the button is pressed , time decreases 10 minutes.

If the button is kept pressed ,time will change quickly.

It can be adjusted within 24 hours at will.AM stands for morning and PM stands for afternoon.

4.Timer confirming for TIMER ON

After set correct time,press TIMER button to confirm time. And now

ON stops flash,while OFF starts flash

Time displayed : unit starts at X hour X min.

5.Timer setting for TIMER OFF

Press time button, and follow the same procedures in ì Time setting for TIMER ONî

6.Time confirming for TIMER OFF

After time setting, press SET button to confirm time.

OFF stops flash.

Time displayed : unit starts at X hour X min.

7.Canel TIMER mode

Just press TIMER button several times until TIMER mode disappears.

According to the time setting sequence of TIMER ON or TIMER OFF, either start-stops or stops-start can be realized.

If the time setting of TIMER ON is the same as TIMER OFF, the TIMER

ON-OFF function cannot be set.

13

Safety Precautions

Carefully read the following information in order to operate the air conditioner correctly.

Below are listed four kinds of Safety Cautions and Suggestions:

WARNING: Incorrect operations may result in severe consequences of death or serious injures.

CAUTION : Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences.

: It must be strictly prohibited where marked with ì Prohibited î, otherwise may result in

machine damages or endanger the userípersonal safety.

INSTRUCTION: This information can ensure the correct operation of the machine.

Be sure to conform with the following important Safety Cautions.

The Safety Cautions should be at hand so that they can be checked at any time when needed.

If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user.

WARNING

If any abnormal phenomena are found (e.g.

smell of firing),please cut off the power supply immediately, and contact the dealer to find outí the handling method.

Call the dealer to take measures to prevent the refrigerant from leaking.

In such case,to continue using the air conditioner will damage the conditioner,and may cause electrical shock or fire hazard.

Switch off

The leaked refrigerant over certain density may cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage

When air conditioner is removed and reinstalled dealer should be responsible for them.

Incorrect installation may cause water leaking, electrical shock and fire hazard.

When need maintenance and repair,call dealer to handle it.

Incorrect maintenance and repair may cause water leak, electrical shock and fire hazard.

Donít dismantle the outlet of the outdoor unit.

The exposure of fan is very dangerous witch may harm human beings.

Donít put figures or any other things into the inlet/outlet and swing louver while the conditioner is in operation

Because the high-speed fan is very dangerous and may cause injures.

After a long time use of air conditioner the base should be checked for any damages.

If the damaged base is not repaired, the unit may fall down and cause accidents.

14

Safety Precautions

No goods or nobody is permitted to be placed on or stand on outdoor unit.

The falling of goods and people may cause accidents.

WARNING

Donít clean air conditioner with water.

Otherwise may cause shock.

Don't operate the air conditioner with damp hands.

Otherwise will be shocked.

Only use correct type fuse.

May not use wire or any other materials replacing fuse,otherwise may cause faults or fire accidents.

Donít place any burning unit in the airflow of air conditioner,which may cause incomplete combustion

No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident.

Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.

Connect earthing wire.

Earthing wire should not be connected to the gas pipe, water pipe,lightning rod or phone line,incorrect earthing may cause shock.

Use discharge pipe correctly to ensure efficient discharge.

In correct pipe usage may cause water leaking.

Air conditioner canít be be installed in the environment with inflammable gases.

The inflammable gases near to air conditioner may cause fire hazard.

Not permitted when running

Installed electrical-leaking circuit breaker.

It easily causes electrical shock without circuit breaker.

When use the fumigating insecticide donít operate air conditioner.

Otherwise the poisonous chemicals may settle in air conditioner, which harm the health of chemical-allergic people.

15

Maintenance

Clean the unit

Turn off the power supply switch Do not touch with wet hand. Do not use hot water or volatile liquid

ON

OFF press the locks

Take down air inlet grille

As the figure, press the two locks on air inlet grille vertically, and make it move to grille, then rise it up 45 degree gently to take out the grille.

Take down the filter

Press the outside two edges of inlet grille with the thumbs, and pull out the filter corner with the forefingers, to rise the filter up after it moves away from the locks, then take out the filter.

filter corner lock grille edge

Clean the air filter

Clean the air filter with water or vacuum cleaner.

Use the detergent or neutral soapy water if the air filter is too dirty. Then rinse the air filter with water,and reinstall after drying.

Caution:

Do not clean the air filter with hot water over 40 C, otherwise may damage the filter.

Sweep the filter carefully.

take out the grille

Clean indoor (outdoor ) unit

Clean with hot wet cloth and neutral detergent, then wipe with dry cloth.Do not use too hot water (over 40 C) which may result in fading and deforming. Do not use insecticide and chemical washing agent.

16

Troubleshooting

Seasonal Reserve

Post-season Care

Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well.

Stop operation and turn off the power supply switch .Electric

power is consumed even the air conditioner is in stop.

Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.

Pre-season Care

See that there is no obstacles blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reducing the working efficiency.

Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in machine damages or cause malfunciton due th dust inside the unit

17

Troubleshooting

The followings are not malfuncition

Water flowing sound is heard

Hua

Hua

When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction.

Cracking sound is heard

It smells.

During operation, white fog comes out of indoor unit.

This is caused by heat expansion or contraction of plastics

Air blown out from the indoor unit sometimes smells. The smell results from smells of furniture, paint , tobacco absorbed by indoor unit.

When in COOL or DRY mode, a thin water fog can be seen blown out of unit ,this is the condensed fog because the suddenly cooled indoor air is blown out.

Automatically switch into FAN mode during cooling.

To prevent frost from being accumulated on the indoor unit heat exchanger, it sometimes automatically switched into the FAN mode,but it will soon back to the cooling mode.

The air conditioner cannot be restarted soon after it stops.

Air conditioner does not start?

This is because of the self-protection function of the system, therefore,it cannot be restarted for about three minutes after it stops.

Please wait for three minutes

18

Troubleshooting

Air does not blow or the fan speed cannot be changed during drying.

In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting

Water or vapor generated from the outdoor unit during heating.

Please check the following things about your air conditioner before making a service call.

Unit fails to start.

Is the power supply switch on ?

Is city supply power normal ?

Is the earth leakage breaker in action ?

**?

ON

OFF

Power supply switch is not in

ON position.

Be sure to turn off the power supply switch immediately and contact the sales dealer.

19

When Trouble Happens

The operation controller adjusted as required

Insufficient cooling or heating

Air filter too dirty ?

Horizontal swing louver upward ? (in HEAT mode)

Any obstacle exists at the air inlet or outlet?

Door or window left opened ?

Any other heat sources in the room?

Insufficient cooling

Sunlight direct into the room ?

Too crowed in the room ?

Cooled air blown out ( when heating)

When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed,stop the operation of the air conditioner and contact your sales dealer.

1.The fuse or breaker often shuts down.

2.Water drops off during cooling or drying operation.

3.There is an irregularity in operation or abnormal sound that is audible.

20

Customer Need-to-know

Customer Need-to-know

Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well.

Be careful not to scratch the surface of the case during moving the air conditioner.

Please keep the installation manual for future reference when maintenance and changing installation place.

After installation ,please use the air conditioner according to the specification in the operation manual.

Adjust suitable airflow direction

Using Directions

Avoid direct sunlight and airflow

Keep the proper indoor temperature.

Too cool is not good for your health.

Furthermore,it will result in excessive consumption of electric power.

Effectively use timer.

Using TIMER mode, you can make the room temperature reach a suitable temperature when you wake up or back home.

Optimal temperature

ATTENTION: after finishing installation,confirm no refrigerant leakage.

21

C

D

A

B

E

F

Installation Tools

Installation tools

The installation tools listed in the following sheet can be used as required.

1. Screw driver

2. Hacksaw

3. Drill with a diameter of 60mm

4. Inner hexagon spanner,shifting

spanner

5. Spanner (14, 17, 19,24,27mm)

6. Pipe cutter

7. Pipe expander

8. Knife

9. Pincers

10. Leakage detector or soapy water

11. Band tape

12. Scraper

13. Refrigerant oil

Standard accessories

The following parts mentioned in this manual are the installation accessories we prepared.

Symbol Parts Name

Adhesive tape

Pipe clamp

Connecting hose

Drainage hose

Non-hydroscopic heat insulating material

Gypsum powder

22

Installation Procedures

Installation of Outdoor Unit

Selection of installation place

Place strong enough to support unit weight, and will not cause vibration and noise.

Place where discharged wind and noise do not cause nuisance to the neighbors, and is sufficiently ventilated.

Place where is less affected by rain or direct sunlight and sea breeze.

Place with enough space for smooth air flow.

The unit cannot be installed on an unspecified metal frame (e.g. theft guard net).

It shall be not less than 2.5m high from the ground if the outdoor unit is installed close to a street.

Easy for maintenance.

Fixing the unit

Fix outdoor unit bracket to the wall using anchor bolt (M10).

Fasten the outdoor unit onto the installation bracket with bolt (M10) and nut ,and keep it horizontal.

If installation on the wall or on top of a roof, bracket shoukd be fixed securely to resist earthquake or storms.

Be sure to use rubber pad during installation against unit vibration.

Install the unit in such a way that the angle of inclination is lees than 3 degrees.

140 500 140

Installation dimension of outdoor unit (mm)

Open space requirement around the unit

L

2

Air inlet

Air inlet

L

3

Air outlet

L

1

500

(Servicing space)

Note :

(1). Fix the parts with screws

(2).Don't intake the strong wind directly to the

outlet air-flow hole.

(3).A one meter distance should be kept from the

unit top

(4).Don't block the surroundings of the unit with

sundries

23

Installation Procedudres

1.Selection of Installation Place

(1) Place above the ceiling where have enough space to arrange the unit.

(2) Place where the drainage pipe can be arranged well.

(3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked.

(4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop).

(5) Do not set the unit in the place where destructive gas (such as sulfuric acid gas) or pungent

gas (thinner and gasoline) concentrates and retains.

(6) Place strong enough to support the unit weight.

(7) No expensive articles such as television and piano below indoor unit.

(8) Enough space for maintenance.

(9) Place more than 1m away from television and radio to avoid disturbing television and radio.

(10) Easy for maintenance.

Air outlet Air inlet Air outlet

1.5m

1.5m

2.5m Over

2.Installation Preparation

(1) Position of ceiling opening between unit and suspending bolt (front view of unit).

Overlap between ceiling and ornament panel shall be 25mm

Suspending bolts

Ceiling

Ornament panel

Distance between suspending bolts 535mm

Indoor unit 570mm

Ceiling opening 650mm

Ornament panel 700mm

(2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of remote controller,

indoor unit connection wires) to the indoor unit before installation in order to connect indoor unit

immediately after installation.

24

Installation Procedures

(3) Install a suspending bolt

To support the unit weight ,anchor bolt should be used in the case of already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field.

Before going on installing, adjust space to ceiling.

Roof

Anchor bolt

Long nut or thread

Suspending bilt M10

Ceiling

Note: All the above mentioned parts shall be prepared in feild, the diameter of suspending bolt is M10

Installation of indoor unit

<Installation Example>

In case of no ceiling

Install unit temporally

Put suspending bracket on the suspending bolt to hang the unit up. Be sure to use nut and washer at both end of the breaket to secure firmly.

After installation on the ceiling

(1) Adjust unit to its right position (Refer to preparation for installation-(1))

(2)Check that unit is horzontal.

Water pump and floating switch is installed inside indoor unit,check four corners of the unit for its lever using horizontal comparator or PVC tube with water.(If unit is tilting against the direction of water drainage,problem may occur on floating water leakage.)

Nut (Prepare in feild)

Washer (Prepared in feild)

In the case of ceiling already exists

(1)Install unit temporally

Put suspending bracket on the suspending bolt to hang the unit up.Be sure to use nut and washer at both end of the bracket to secure it firmly.

(2)Adjust the height and position of the unit.

(3)Proceed with procedure (4) of ì In the case of no ceiling ì

Suspending bolts

Fasten (double nuts) leveler

Polythene pipe

25

Insert

Washer fixing pad

(prepared in feild)

[ secure the washer firmly]

Installation Procedures

3.Installation of water drainage pipe

(1) Install water drainage pipe

Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size:

25mm; O.D.: 32mm )

Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming.

If downward slope of drainpipe cannot be made,lifting pipe shall be installed.

Keep a distance of 1-1.5m between suspending bolts, to make water hose straight.

1-1.5m

slope over 1/100

Use the drainage hose and clip provided with unit.

Insert water pipe into water plug until it reaches the white tape.

Tighten the clip until head of the screw is less than 4mm from hose.

Wind the drainage hose to the clip using seal pad for heat insulation.

Insulate drainage hose in the room.

Clip

Large size seal pad

(accessory)

Clip

Tape(white) Draingage hose

4mm below

Cautions for the water drainage lifting pipe

Installation height of water drainage lifting pipe shall be less than 280mm

There should be a right angle with unit ,300mm from unit.

300mm below 1-1.5m

Drainage hose

Suspending bracket

Water drainage lifting pipe

280mm unter

Drainage hose

Clip

220mm

< Note >

The slope of water drainage hose shall be within 75mm , make the drainage plug not to bear excessive force.

If several water hoses join together, of as per following procedures.

Slope below 1/100

Connection drainage hose with a T-joint

Specifications of the selected drainage hoses shall meet the requirements for the unit running

26

Installation Procedures

4. Installation of Ornament Panel

Install ornament panel on indoor unit

(1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and

check that the dimension of the ceiling opening is correct. Take off the lever gauge before install

the ornament panel.

(2)Fasten the screws to make the height difference between the two sides of indoor unit less than

5mm.

(3) First fix it with screws temporally.

(4) Fasten the two temporally fixing screws and other two, and tighten the four screws.

(5) Connect the wires of synchro-motor.

(6) Connect the wire of signal.

(7) If no response of remote controller,check whether the wiring is correct,restart remote controller

10 seconds after shut off power supply.

Electric control box

Limits of panel board installation

(1)Install the panel board in the direction shown in

the figure.

(2)The incorrect direction will result in water leakage,

meanwhile swing and signal receiving are displayed

that cannot be connected.

27

Installation Procedures

Piping Connection

Flare connection

Gas pipe

Indoor

Unit

3-way valve

Outdoor unit

Liquid pipe

(1) Dimension of connecting pipe

Gas pipe

Liquid pipe

12.7mm

6.35mm

3-way valve

Flare connection

90 + 0.5

Fit the nut on and fasten

*

(2) The maximum length and drop height of connecting pipe

The maximum length is 10m

The maximum drop height is 5m.

To ensure the efficiency ,Pipes shall be as short as possible.

Spanner

Cautions for piping connection

Do not twist or deform the connecting pipe.

Do not mix dusts.

The bending radius shall be as large as possible.

Both gas pipe and liquid pipe shall be heat insulation.

No leakage in the flare.

Spanner

Joint

N u t

(3) Piping connection

Connecting method

Smear refrigerant oil on the joints of piping and flare.

The bending radius shall be as large as possible.

Align the pipe center when fastening, and tighten the nut, as shown in the figure.

Pay attention to not mix foreign matters such as sands in.

Diameter of Pipe

Liquid Pipe 6.35mm

Gas Pipe 12.7mm

Tighten Torque

18 N. m

50N. m

If not aligned ,tighten the nut by force will damage the nut that result in gas leakage

28

Installation Procedures

(4) Purging method ( the refrigerant is R407C)

To use vacuum pump

1

Detach the service port's cap of 3-way valve, the valve rod's cap for 3-way valve and 3-way's, connect the service port into the projection of charge hose

(low) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump.

3-way valve

3-way valve

Liquid pipe

6.35mm(1/4'')

Gas pipe

15.88mm(5/8'')

Gaugemanifold

2

Open the handle at low in gaugemanifold, operate vacuum pump. If the scale-moves of gause (low) reach vacuum condition in a moment, check 1 again.

2 Open

Vacuum pump

3

Vacuumize for over 15min. And check the level gauge which should read -0.1 MPa (-76 cm Hg) at low pressure side. After the completion of vacuumizing, close the handle 'Lo' in gaugemanifold and stop the operation of the vacuum pump.

Check the condition of the scale and hold it for 1-2min.

If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of 3 .

3 Close

3-way valve

4

Open the valve rod for the 3-way valve to and angle of anticlockwise 90 degree.

After 6 seconds later, close the 3-way valve and male the inspection of gas leakage.

90

90

3-way valve

4

Service port

90 for 6 sec.

5

No gas leakage?

In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed steps.

6

6

Detach the charge hose from the service port, open

3-way valve and 3-way. Turn the valve rod anticlockwise until hitting lightly.

If it does not stop gas leakage, discharge whole refrigerants from the serice port.

After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder.

3-way valve

6

7

To prevent the gas leakage, turn the service port's cap, the valve rod'd cap for 3-way valve and 3-way's a lottle more than the point where the torque increases suddenly.

8

After attaching the each caps, check the gas leakage around the caps.

3-way valve

3-way valve

6

CAUTION:

If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.

3-way valve

7 Valve rod cap

7 Valve rod cap

7 Service port cap

If needing to recycle the refrigerant gas when installation or repair , please refer to the following procedures:

1. Cut off the power

2. (After confirming the power is cut off) pull the power cable plug terminals of the low-pressure pressure-switch out.

3. (After confirming the power cable terminals of the low-pressure pressure-switch is cut off) After powering on the unit again

and switch to COOLING mode,perform refrigerant gas recycling according to the normal refrigerant gas recycling procedure.

4. After finishing refrigerant gas recycling , cut off the power , then insert the power cable terminals of the low-pressure

pressure-switch properly.

29

*

Installation Procedures

Electrical Wiring

Cautions: Use copper wire only.Parameters of connecting line :

H05RN-F 4G(3x2.5mm

2

+1x0.75)mm

2

Power supply :1PH,220-230V~,50Hz, connect from indoor unit.

The parameters is : H05RN-F 3x2.5mm

2

Wiring methods:

1.Wiring method of ring termianl

For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and tighten screw.

1(L)

Wiring method of ring terminal

Correct crimp connection of wire

Incorrect crimp connection of wire

2. Wiring method of straight terminal

For connecting line which end is not a ring, its wiring method as follows: loosen wiring screw ans insert the end of connecting line totally into the terminal block,then tighten the screw and pull the connecting line slightly to confirm that it is clamped firmly.

Terminal block

Crimp connection clamp

Crimp connection method of connecting line

After finishing wiring.connecting line must be fastened by wire clamp,which pressed on the external sheath of the connecting line, as shown in the right figure:

Wiring of indoor unit

Open air inlet grill

Take the leading end of connecting line

Connect connecting line according to wiring methods and wiring diagram of indoor and outdoor unit

INDOOR UNIT

TERMINAL BLOCK

Fasten connecting line according to crimp connection method of connecting line.

Reinstall air inlet grill.

OUTDOOR UNIT

TERMINAL BLOCK

POWER SUPPLY: 1PH,220-230V~,50Hz

L N 1 2 3

BR BL Y/G Y/G

W B

4

BL BR

1 2 3

W B R

4

BR

5

G Y/G

Y/G

1.Installation fixing

Fix outdoor unit installation bracket on the wall using a

M10 anchor bolt.Fix outdoor unit on the installation bracket firmly using bot(M10) and nut, and keep it on horizontal level.

When installing on the wall or on the roof ,fix the bracket, firmly to prevent earthquake or storm.

Be sure to use rubber-damping cushion to reduce unit vibration.

2.Installation of drain elbow

Installation of drain elbow.(Only for heat pump type air conditioner, no drain elbow for single cooling type).If use drain elbow,please install as shown in the figure.

Do not use drain elbow in cold place (temperature successively below 0 C)

3. Connection of outdoor piping

Connect the connecting pipe according to the piping connection method

4.Wiring connection

1.Open the wiring cover and loosen the wiring clamp.

2.Lead the connecting wire out and pass it through the wiring clamp.

Drain eblow

Terminal

Wire clamp

Power supply

Connecting wire between inner and outer

3.Connect the connecting wire according to the wiring method and

diagram

4. Confirm the ends of wire are connected well, safe and correct.

5. After finishing wiring, press the connecting wire according to the wire crimp connection method and reinstall the cover.

Drain hose

30

Installation Procedures,Check and Test Run

Other Instructions

1.Configuration of power supply

Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard.

In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together.

A leakage breaker must be installed.

Parameters of power supply: H05RN-F 3G 2.5

mm

2; connected wire : H05RN-F 3x2.5mm

2

+1x0.75mm

2

Connection method is Y-connection .If the power cord is damaged, it must be replaced by professional people of manufacturer or its maintenance department or similar to avoid dangers.

2.Pipe cutting and expanding

Must remove burrs if cut pipes with pipe cutter.

Expand flare after insert the pipe expander.

Liquid pipe

Gas pipe

Diameter of pipe

6.35mm (1/4î)

12.7mm (1/2î)

Dimension A (mm)

0.8~1.5

1.2~2.0

A

Pipe expander

Correct Incorrect

Deflection Crack occurs Broken Incomplete Over outward

Installation check and test run

Require customers to use air conditioner according to the operation manual.

The items checked during test run,please mark in

No gas leakage on the pipe joint ?

How about the thermal insulation of the pipe joint:

Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly?

Is the wiring of indoor and outdoor unit secured firmly?

Is the drainage hose arranged correct?

Is the earthing wire connected firmly?

Is the power supply voltage conformed to the electrical regulation?

Any noise?

Is the display on the control board (LCD) correct?

Cooling normal?

Does the indoor temperature regulator work normally?

For the power supply

L shall be connected to the live wire.

N shall be connected to the neutral wire.

Shall be connected to the earth wire.

31