CASSETTE AIR CONDITIONER
Operation
Manual
AB142ACNAC
AU142AANAC
(HBU-14CL03/R1)
AB142ACBAC
AU142AABAC
(HBU-14HL03/R1)
No.0010571459
Main points of Operation
Operation of Air Conditioner
When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode.
3-minute Protection Function
If restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect the machine.
Variation of Fan Speed
If fan speed in auto mode, it will automatically lower when the room temperature close to the setting temperature in cooling mode.
In heating mode,the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops.
In Dry mode,fan speed will be automatically varied.
Remote Control:
There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a faraway place.
3
Main points of Operation
Prevent Cool Air Blowing Off
In heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off.
Wait a minute
Defrosting Function
In heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defrost a few minutes. During defrosting, both indoor and outdoor fan will stop running. When defrosting finished, air conditioner will automatically back to running.
Defrosting Running
Hints
The air conditioner absorbs heat form outside and releases inside when in heating mode, therefore the outside environmental temperature will affect heating effects.
Power Failure Compensation(to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press
the ìsleepingî button on the remote controller 10 times within 5 seconds,and
after the buzzer rings 4 times,the air conditioner will enter the state of power
failure compenstation.
Cancel Method:Press the ìsleepingî button on the remote controller 10 times within 5 seconds,
and after the buzzer rings 2 timer,the power failure compensation mode will be
cancelled.
Note: When a power failure suddenly occurs during the air conditioner si working after the
power after the power failure compensationis set,if the air conditioner will not be used
for a long time, please cut off the power supply to prevent its operation from being res-
umed after the power is supplied again, or press the ì Switch On/Off î button after the
power comes again.
4
Name of Each Part
Indoor unit
Swing louver
(Air flow direction can be adjusted by using the SWING button on the remote controller)
Electrical Components Case
Air Inlet Grille
Air Filter
(Inside of the Inlet Grille)
outdoor unit
Air Inlet (side)
Air Inlet (back)
Conneting pipe and electrical wiring
Air Outlet
(blow out hot air when cooling and cool air when heating)
5
Name of Each Part
2
3
4
5
6
7
8
24
25
26
27
28
29
30
31
32
1
Remote controller
AUTO
ON OFF
C
SWING
TEMP
ON
OFF
FAN
MODE FILTER
CLOCK SET
TIMER
LOCK RESET
SLEEP
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
1.TEMP Setting Button
(Used to set temperature, setting ranges:
16 C to 30 C)
In Up/Down function,for controlling up and down filter.
2.SWING Button
Press once auto swing, press again the swing louver fixed on the present swing position.
3.Power ON/OFF Button (used for unit
start and stop)
After power on, the LCD of remote controller will display the previous operation state (except for TIMER,SLEEP and SW-
ING state).
4.Operation MODE
Used to select operation mode.
Every time press MODE button,operation mode changes according ot hte following order:
AUTO COOL DRY HEAT
11.SLEEP Button
(The clock must be corrected before set sleep function)
Used to set sleep mode.
12.SET Button
FAN
5.CLOCK Button
Used to set correct time.
6.TIMER Button
Used to select TIMER mode:TIMER ON,TIMER
OFF, TIMER ON/OFF.
(Note: if time of TIMER ON is the same as TIMER
OFF,TIMER ON/OFF cannot be set)
7.LOCK Button
Used to lock operation button and LCD display contents: after press this button, other button are out of function, lock state display appears; press again,cancel lock state and lock state display disappeared.
8.RESET Button
Used to sharp article press this button can reset the remote controller back to normal condition when it in malfunction state.
9.Battery Loaded Indication
10.HOUR Adjustment
Used to set clock and timer setting
Used to confirm TIMER and CLOCK settings.
13. FILTER Button
Used to set up/down function of filter.
14.FAN Button
Used to select fan speed:LOW,MID,HIGH,AUTO.
NOTE: 1.Single cooling air conditioner does not have the displays and functions related to heating.
2.This kind of unit does not have the following related functions and displays: 16 19
20
22 23 24 25 27
5
Name of Each Part
15.TIMER OFF Display
16.HUMIDIFICATION Display
17.TEMPERATURE Display
18.LOCK State Display
19.BATTERY Energy Display
Display when in low battery to remind customer to change the battery.
20.STRONG/QUITE Run Display
21.SIGNAL SENDING Display
22.NEW AIR Display
23.ELECTRICAL HEATING Display
24.HEALTH Display
Display when healthy run function is set.
25.SLEEP State Display
26.Operation MODE Display
AUTO RUN COOL RUN DRY RUN HEAT RUN
FAN RUN
When electronic-strated type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter.
Loading of the battery (load the batteries as illustrated)
Remove the battery cover
First slightly press the position marked with and push down the cover,then as shown in the figure:holding the upper part of the remote controller with the left hand and the right hand slightly grasps the battery box cover and forces on the arrow direction to remove the cover.
27.COMFORTABLE RUN Display
28.FAN SPEED Display LO
MID
HI
AUTO
AUTO
29.AUTO SWING Display
30.TIMER Display
31.FILTER Display
32.TIMER ON Display
Remote Controllerí Operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Donít throw the controller,prevent it from being damaged.
Load the battery
Be sure that the loading is in line with the ì + î ì - î pole request as illustrated on the botton of the box.
Put on the cover again
Installing the cover is opposite to removing it
Confirmation indicator
If no indication after press ON/OFF button,reload the batteries.
Note:
Use two new same-typed batteries when loading.
If the remote controller canít run normally during operation ,please remove the batteries and reload them few minutes later that will be ok
If the display of remote controller is faded(sometimes run abnormally),which indicates no battery,so please change the batteries
Hint:
Remove the batteries in case unit will not be in usage for a long period.if there is any display after taking-out just need to press reset button with a sharp article
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1.Press CLOCK button,clock indication of ì AM ì or ìPMî flashes.
2.Press or to set correct time,each press will increase or decrease
1 min. If the button is kept pressed, time will increase or decrease quickly.
3.After time setting is confirmed,press ìSETî , AM or PM stop flashing,
while clock starts working.
Note:AM means morning and PM means afternoon.
MODE
CLOCK
1
TIMER
FILTER
SET
2
SLEEP
3
LOCK RESET
7
Safety Cautions
Carefully read the following information in order to operate the air conditioner correctly.
Below are listed four kinds of Safety Cautions and Suggestions:
WARNING: Incorrect operations may result in severe consequences of death or serious injures.
CAUTION : Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences.
: It must be strictly prohibited where marked with ì Prohibited î, otherwise may result in
machine damages or endanger the userípersonal safety.
INSTRUCTION: This information can ensure the correct operation of the machine.
Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any time when needed.
If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user.
WARNING
If any abnormal phenomena are found (e.g.
smell of firing),please cut off the power supply immediately, and contact the dealer to find outí the handling method.
Call the dealer to take measures to prevent the refrigerant from leaking.
In such case,to continue using the air conditioner will damage the conditioner,and may cause electrical shock or fire hazard.
Switch off
The leaked refrigerant over certain density may cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage
When air conditioner is removed and reinstalled dealer should be responsible for them.
Incorrect installation may cause water leaking, electrical shock and fire hazard.
When need maintenance and repair,call dealer to handle it.
Incorrect maintenance and repair may cause water leak, electrical shock and fire hazard.
Donít dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous witch may harm human beings.
Donít put figures or any other things into the inlet/outlet and swing louver while the conditioner is in operation
Because the high-speed fan is very dangerous and may cause injures.
After a long time use of air conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
8
Safety Cautions
No goods or nobody is permitted to be placed on or stand on outdoor unit.
The falling of goods and people may cause accidents.
WARNING
Donít clean air conditioner with water.
Otherwise may cause shock.
Don't operate the air conditioner with damp hands.
Otherwise will be shocked.
Only use correct type fuse.
May not use wire or any other materials replacing fuse,otherwise may cause faults or fire accidents.
Donít place any burning unit in the airflow of air conditioner,which may cause incomplete combustion
No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident.
Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Connect earthing wire.
Earthing wire should not be connected to the gas pipe, water pipe,lightning rod or phone line,incorrect earthing may cause shock.
Use discharge pipe correctly to ensure efficient discharge.
In correct pipe usage may cause water leaking.
Air conditioner canít be be installed in the environment with inflammable gases.
The inflammable gases near to air conditioner may cause fire hazard.
Not permitted when running
Installed electrical-leaking circuit breaker.
It easily causes electrical shock without circuit breaker.
When use the fumigating insecticide donít operate air conditioner.
Otherwise the poisonous chemicals may settle in air conditioner, which harm the health of chemical-allergic people.
9
Guide to Operation
Fan Operation
1.Unit start
Press ON/OFF button, unit starts.
Previous operation status appears on LCD (except for
TIMER ,SLEEP, and SWING setting).
2.Select operation mode
Press MODE button. For each press,operation mode changes as follows:
AUTO COOL DRY HEAT FAN
Then select FAN
3. Adjust fan speed
Press FAN button.For each press,fan speed changes as follows:
TEMP
SWING
4
ON
OFF
1
FAN
3
FILTER
2
MODE
CLOCK SET
TIMER
LOCK RESET
SLEEP
LOW MID HIGH
Air conditioner will run at the selected fan speed.
When in AUTO mode,unit will adjust fan speed according to room temperature automatically.
4. Unit stop
Press ON/OFF button,unit stops.
About FAN Operation
FAN operation refers that the air conditioner only run
FAN,no COOL and HEAT operation,and in this status the unit canít operate AUTO FAN as well no temperature settings.
10
Guide to Operation
AUTO run, COOL , HEAT and DRY Operation
C
1. Unit start
Press ON/OFF button,unit starts.
Previous operation status appears on LCD (except for
TIMER,SLEEP and SWING setting)
2.Select operation mode
Press MODE button. For each press,operation mode changes as follows:
3
SWING
5
TEMP
ON
OFF
1
FAN
4
3
FILTER
2
MODE
CLOCK SET
TIMER
LOCK
RESET
SLEEP
AUTO COOL DRY HEAT FAN
Then select AUTO run or select COOL operation or select DRY operation or select HEAT operation
3.Temperature setting
Press TEMP button.
Every time the button is pressed, temp. setting increases
1 C, if the button is kept pressed, temp. setting will increase quickly.
Every time the button is pressed, temp. setting decreases
1 C, if the button is kept pressed, temp. setting will decrease quickly.
Set proper temperature
4.Adjust FAN button
Press FAN button .For each press, fan speed changes as follows:
AUTO
COOL operation starts when room temp.is
higher than temp.
setting.
Ultra-low air flow
Temp. setting +2 C
Temp.setting
On reaching temp.setting
+2 C, unit will run in mild
DRY mode.
AUTO LOW MID HIGH
Air conditioner will run at the selected fan speed.
5. Unit stop
Press ON/OFF button,unit stops.
In ATUO mode,the temperature setting is not displayed on LCD.In this mode,during running air conditioner will select COOL ,HEAT or FAN mode automatically according to the room temperature.
In DRY mode,when room temperature becomes 2 C higher than temperature setting, unit will run intermittently at LOW speed regardless of FAN setting,When room temperature is lower than temperature setting,unit will only run FAN operation.
In HEAT mode,warm air will blow out after a short period of time due to cold-draft prevention function,
11
Guide to Operation
Air flow direction adjust
AUTO SWING AUTO SWING
Press SWING button.
Up and down airflow vary upwards and downwards.Left and right airflow vary left and right sides.
When the automatic swing louver moves to the proper angle,press SWING button can fix the airflow direction.
Always use SWING button on the remote controller to adjust louver or flaps because if adjust it by hand may result in air conditioner running abnormally.
AUTO
C
In COOL or DRY mode, the louver is not permitted to be in downwards position for a long time because the water vapor close to the grille may be condensed and the water may drop from the air conditioner.
SWING
TEMP
ON
OFF
FAN
MODE FILTER
CLOCK
TIMER
LOCK
SET
RESET
SLEEP
Please carefully set temperature setting when infants,children,old people and patients use the air conditioner.
In case of great humidity ,If the vertical flaps all towards left or right,the louver will drop water.
Donít pull louver directly by hand which will make it work abnormally.If the louver work abnormally,stop unit,restart and adjust by remote controller.
After unit stops:
Displays on the LCD disappear.
All indicators on the indoor unit go out.
Swing louver automatically close the air outlet.
Hints:
As cold airflows downward in COOL mode,adjusting airflow horizontally will be much more helpful for a better air circulation
AS warm airflows upward in HEAT mode,adjusting airflow downward will be much more helpful for a better air circulation.
Be careful not to catch a cold when cold air blows downward directly.
12
Guide to Operation
Sleep Function
Before going to bed you can press down the SLEEP button and the air conditioner will run by the comfortable sleeping mode to make you sleep more comfortable.
Before use this function, the clock must be corrected.
Usage of SLEEP function
After unit start,first set running mode and then press SLEEP button once.Mark the air conditioner have the previous-set sleep time(first power-on or after carrying out sleep function is 1h),the sleep symbol will appear. Press time button / , you can choose the time in 1~8 hours.Each time the button is pressed the time increases/decreases 1 hour and ì xh î appears in the humidity setting part ,ì OFF î appears in ì TIMER OFF î display part and the sleep symbol disappears.
Operation Mode
1.In COOL, DRY mode
One hour after sleeping operation start, the temp.
is 1 C higher than the setting one. After another hour the temp. rises 1 C and then run continuously for another 6 hrs and then close. The actual temp.
is higher than the setting one which is to prevent from being too cool to your sleep.
2.In HEAT mode
One hour after sleeping operation start, the temp.
decreases 2 C lower than the setting one. After another hour decreases by 2 C more. The temperature will automatically rise by 1 C after an other
3 hrs operation ,and then automatically close after
3 hrs continuous operation.The actual temperature is lower than the setting one which is to prevent from being too hot to your sleep.
3.In AUTO mode.
The air conditioner will run in corresponding sleep operation according to the automatically selected operation mode.
4.In FAN run
Canít use SLEEP function.
SLEEP RUN BEGINS SLEEP RUN STOPS about 6 hrs
1 hrs increase 1 C increase 1 C
SETTING T SHUT DOWN
In COOL,DRY mode
SETTING T SHUT DOWN
1 hrs
1 hrs decrease 2 C decrease 2 C about 6 hrs
3 hrs increase 1 C
SLEEP RUN BEGINS SLEEP RUN STOPS
In HEAT mode
Note:
After setting SLEEP function ,it is forbidden to calibrate clock.
If the set sleep-time does not reach 8 hours, unit will stop operation automatically after set time is complete.
Set ì TIMER OFF îIn COOL,DRY mode function first, then set SLEEP, unit will perform sleep function.
After set SLEEP function, the TIMER function cannot be set.
Set ì TIMER ON îIn COOL,DRY mode function first,then set SLEEP, the sleep function can only be set before TIMER ON time.
After setting SLEEP function,press CLOCK button to show the time; press
TEMP button to show the temperature setting; press again to change the temperature.
13
OFF
SWING
TEMP
ON
OFF FAN
MODE FILTER
CLOCK
TIMER
LOCK
SET
RESET
SLEEP
Guide to Operation
Timer ON/OFF Function
Set clock correctly before starting TIMER operation
1.Unit start
After unit start ,select your desired operation mode(operation mode will be displayed on LCD)
2.TIMER mode selection
Press TIMER button on the remote controller to change TIMER mode.Every time the button is pressed,display of TIMER mode changes as follows:
ON OFF ON OFF
AM 12:00
PM
12:00 AM 12:00
PM
12:00
TIMER ON TIMER OFF TIMER ON-OFF blank
ON
C
Then select TIMER mode as needed (TIMER ON or TIMER OFF).
SWING
TEMP
ON
OFF
1
FAN
MODE FILTER
CLOCK
2
TIMER
LOCK
SET
3 4
SLEEP
RESET
3.TIMER setting (press time adjust button)
Every time the button is pressed , time increases 10 minutes.
If the button is kept pressed ,time will change quickly.
Every time the button is pressed , time decreases 10 minutes.
If the button is kept pressed ,time will change quickly.
It can be adjusted within 24 hours at will.
4.Confirm setting
After set correct time,press SET button to confirm time. And now
ON
Time displayed: unit starts or stops at X hour X min (TIMER ON or TIMER OFF)
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears
Hints:
After replacing batteries or a power failure happens,TIMER setting should be reset.
Remote controller possesses memory function,when use TIMER mode next time,just press SET button after mode selection if timer setting is the same as previous one.
Note:
After setting TIMER function,the remote controller displays TIMER time.If you want to see clock time, just press CLOCK button once it will display clock time (continuously press twice,you can adjust clock, see page 6 for details), and 5 seconds later it will back to TIMER time.
14
Guide to Operation
Timer ON-OFF Function
Set clock correctly before starting TIMER operation
1.Unit start
After unit start ,select your desired operation mode(operation mode will be displayed on LCD)
2.TIMER mode selection
Press TIMER button on the remote controller to change TIMER mode.Every time the button is pressed,display of TIMER mode changes as follows:
ON OFF ON OFF
AM 12:00
PM
12:00 AM 12:00
PM
12:00
TIMER ON TIMER OFF TIMER ON-OFF blank
OFF
C
ON Then select TIMER ON-OFF mode.
ON will flash.
SWING
TEMP
ON
OFF
1
FAN
MODE FILTER
CLOCK
2
4
TIMER
5
SET
3 6
SLEEP
RESET
3.Time setting for TIMER ON
Press time button
Every time the button is pressed , time increases 10 minutes.
If the button is kept pressed ,time will change quickly.
Every time the button is pressed , time decreases 10 minutes.
If the button is kept pressed ,time will change quickly.
It can be adjusted within 24 hours at will.AM refers to morning and PM refers to afternoon.
4.Timer confirming for TIMER ON
After set correct time,press TIMER button to confirm time. And now
ON stops flash,while OFF starts flash
Time displayed : unit starts at X hour X min.
5.Timer setting for TIMER OFF
Press time button, and follow the same procedures in ì Time setting for TIMER ONî
6.Time confirming for TIMER OFF
After time setting, press SET button to confirm time.
OFF stops flash.
Time displayed : unit starts at X hour X min.
7.Canel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
According to the time setting sequence of TIMER ON or TIMER OFF, either start-stops or stops-start can be realized.
If the time setting of TIMER ON is the same as TIMER OFF, the TIMER
ON-OFF function cannot be set.
15
Guide to Operation
Filter Up/Down
After air conditioner operated for a period, dusts were gradually accumulated on the filter ,and the filter up/down function can be used to clean the filter.
1.Whether unit start or stop, continuously press FILTER
button 3 seconds,and enter into the filter up/down waiting
status (when unit stops,the yellow TIMER indicator flashes,
filter and clock displayed on the remote controller and no
others.Only the FILTER button and the temperature button
SWING
TEMP
ON
OFF FAN
1
MODE FILTER
CLOCK SET
TIMER
LOCK RESET
SLEEP
up/down waiting status, the up/down mechanism makes
the filter to move downward and do not stop until reach
the maximum limit.
up/down waiting status , the up/down mechanism makes
the filter to move upward till near to the surface board and
then automatically adjust to reset (when adjusting to reset,
it will not be controlled by the remote controller till the adju-
stment is finished, and the remote controller can control
again.
6.Continuously press FILTER button 3 seconds again to
cancel the filter up/down waiting mode (unit stops, the
yellow timer indicator stops flashing, the filter backs to
the original position , the remote controller backs to off
status and only clock is displayed).
Note:
If the filter does not thoroughly back to the original position,only need to operate several times repeatedly.
16
Maintenance
Clean the unit
Turn off the power supply switch Do not touch with wet hand. Do not use hot water or volatile liquid
ON
OFF
The 4 fixed bolts must be loosed as shown in the figure by arrow if they are bolts, the method is that: push the blots inward till to another edge.
Generally the fixed blots are opened for inlet grille easily up and down as well cheaning the air filter.After open it,lower the inlet grille using remote controller, the maximum distance is 2.24m.
Then turn the 1 rotated clamps 90 degree as shown in the figure, hold the air filter and nearly in the horizontal direction slightly pull it out.
Fixing nolt
Fixing nolt
Fixing nolt
Rotary fixing clamp
Outward drawable filter
Clean the air filter
Clean the air filter with water or vacuum cleaner.
Use the detergent or neutral soapy water if the air filter is too dirty. Then rinse the air filter with water,and reinstall after drying.
Caution:
Do not clean the air filter with hot water over 40 C, otherwise may damage the filter.
Sweep the filter carefully.
Clean indoor (outdoor ) unit
Clean with hot wet cloth and neutral detergent, then wipe with dry cloth.Do not use too hot water (over 40 C) which may result in fading and deforming. Do not use insecticide and chemical washing agent.
17
Troubleshooting
Seasonal Reserve
Post-season Care
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well.
Stop operation and turn off the power supply switch .Electric
power is consumed even the air conditioner is in stop.
Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
Pre-season Care
See that there is no bostacles blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reduce the working efficiency.
Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in machine damages or cause malfunciton due th dust inside the unit
To prevent compressor when start in HEAT mode, please cut in the power supply switch 12 hours before starting run,furthermore, always keep the power supply switch on during the using senson.
18
Troubleshooting
The followings are not malfuncition
Water flowing sound is heard
Hua
Hua
When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction.
Cracking sound is heard
It smells.
During operation, white fog comes out of indoor unit.
This is caused by heat expansion or contraction of plastics
Air blown out from the indoor unit sometimes smells. The smell results from smells of furniture, paint , tobacco absorbed by indoor unit.
When in COOL or DRY mode, a thin water fog can be seen blown out of unit ,this is the condensed fog because the suddenly cooled indoor air is blown out.
Automatically switch into FAN mode during cooling.
To prevent frost from being accumulated on the indoor unit heat exchanger, it sometimes automatically switched into the FAN mode,but it will soon back to the cooling mode.
The air conditioner cannot be restarted soon after it stops.
Air conditioner does not start?
This is because of the self-protection function of the system, therefore,it cannot be restarted for about three minutes after it stops.
Please wait for three minutes
19
Troubleshooting
Air does not blow or the fan speed cannot be changed during drying.
In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting
Water or vapor generated from the outdoor unit during heating.
This happens when the frost accumulated on the outdoor unit is removed (during defrosting operation).
Defrosting operation
During heating,indoor fan is still running even unit is stopped.
To get ride of the excess heat, indoor fan will continue running for a while after unit automatically stops.
Please check the following things about your air conditioner before making a service call.
Unit fails to start.
Is the power supply switch on ?
Is city supply power normal ?
Is the earth leakage breaker in action ?
**?
ON
OFF
Power supply switch is not in
ON position.
Be sure to turn off the power supply switch immediately and contact the sales dealer.
20
When trouble happens
The operation controller adjusted as required
Insufficient cooling or heating
Air filter too dirty ?
Horizontal swing louver upward ? (in HEAT mode)
Any obstacle exists at the air inlet or outlet?
Door or window left opened ?
Any other heat sources in the room?
Insufficient cooling
Sunlight direct into the room ?
Too crowed in the room ?
Cooled air blown out ( when heating)
When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed,stop the operation of the air conditioner and contact your sales dealer.
The fuse or breaker often shuts down.
Water drops off during cooling or drying operation.
There is an irregularity in operation or abnormal sound that is audible.
21
Customer Need-to-know
Customer Need-to-know
Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well.
Be careful not to scratch the surface of the case during moving the air conditioner.
Please keep the installation manual for future reference when maintenance and changing installation place.
After installation ,please use the air conditioner according to the specification in the operation manual.
Adjust suitable airflow direction
Using Directions
Avoid direct sunlight and airflow
Keep the proper indoor temperature.
Too cool or hot is not good for your health.
Furthermore,it will result in excessive consumption of electric power.
Effectively use timer.
Using TIMER mode, you can make the room temperature reach a suitable temperature when you wake up or back home.
Optimal temperature
ATTENTION: after finishing installation,confirm no refrigerant leakage.
22
Installation Tools
Installation tools
The installation tools listed in the following sheet can be used as required.
Following in the list are the accessories supplied with the unit,which can be used as required
1. Screw driver
2. Hacksaw
3. Drill with a diameter of 60mm
4. Inner hexagon spanner,shifting
spanner
5. Spanner (14, 17, 19,24,27mm)
6. Pipe cutter
7. Pipe expander
8. Knife
9. Pincers
10. Leakage detector or soapy water
11. Band tape
12. Scraper
13. Refrigerant oil
Standard accessories
The following parts mentioned in this manual are the installation accessories we prepared.
No.
Accessory parts
1
2
3
4
5
6
7
8
9
Remote controller
Battery
Wire clamp
30x100mm
35x120mm
Heat insulation sheathing
Heat insulation sheathing
Drain elbow
Connecting wire
Qty.
1
2
6
1
1
1 for cooling and heating mode unit
None for cooling only mode
1
4
2 for cooling and heating mode unit
1 for cooling only mode
Symbol Parts Name
Piping hole cover
Rubber cushion
Refrigerant oil
10
***
1
A Adhesive tape
11 1
Plastic clip
B Pipe clamp 12
Blastic cap
Putty
4x25 Screw
1
C
D
Connecting hose
Drainage hose
13
14
15
Steel nail cement
Pipe supporting plate
4
8
1
E
Non-hydroscopic heat insulating material
16
17
Drain hose
Main pipes
1
1
F Gypsum powder
23
Installation Procedures
Installation of Outdoor Unit
Selection of installation place
Place strong enough to support unit weight, and will not cause vibration and noise.
Place where discharged wind and noise do not cause nuisance to the neighbors, and is sufficiently ventilated.
Place where is less affected by rain or direct sunlight and sea breeze.
Place with enough space for smooth air flow.
The unit cannot be installed on an unspecified metal frame (e.g. theft guard net).
It shall be not less than 2.5m high from the ground if the outdoor unit is installed close to a street.
Easy for maintenance.
Fixing the unit
Fix outdoor unit bracket to the wall using anchor bolt (M10).
Fasten the outdoor unit onto the installation bracket with bolt (M10) and nut ,and keep it horizontal.
If installation on the wall or on top of a roof, bracket shoukd be fixed securely to resist earthquake or storms.
Be sure to use rubber pad during installation against unit vibration.
Install the unit in such a way that the angle of inclination is lees than 3 degrees.
140 500
Installation dimension of outdoor unit (mm)
140
24
Installation Procedudres
1.Selection of Installation Place
(1) Place above the ceiling where have enough space to arrange the unit.
(2) Place where the drainage pipe can be arranged well.
(3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked.
(4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop).
(5) Do not set the unit in the place where destructive gas (such as sulfuric acid gas) or pungent
gas (thinner and gasoline) concentrates and retains.
(6) Place strong enough to support the unit weight.
(7) No expensive articles such as television and piano below indoor unit.
(8) Enough space for maintenance.
(9) Place more than 1m away from television and radio to avoid disturbing television and radio.
(10) Easy for maintenance.
Air outlet Air inlet Air outlet
1.5m
1.5m
2.5m Over
2.Installation Preparation
(1) Position of ceiling opening between unit and suspending bolt (front view of unit).
Overlap between ceiling and ornament panel shall be 15mm
Suspending bolts
Distance between suspending bolts 460mm
Indoor unit 570mm
Ceiling opening 600mm
Ornament panel 630mm
Ceiling
Ornament panel
(2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of remote controller,
indoor unit connection wires) to the indoor unit before installation in order to connect indoor unit
immediately after installation.
25
Installation Procedures
(3) Install a suspending bolt
To support the unit weight ,anchor bolt should be used in the case of already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field.
Before going on installing, adjust space to ceiling.
Roof
Anchor bolt
Long nut or thread
Suspending bilt M10
Ceiling
Note: All the above mentioned parts shall be prepared in feild, the diameter of suspending bolt is M10
Installation of indoor unit
<Installation Example>
In case of no ceiling
Install unit temporally
Put suspending bracket on the suspending bolt to hang the unit up. Be sure to use nut and washer at both end of the breaket to secure firmly.
After installation on the ceiling
(1) Adjust unit to its right position (Refer to preparation for installation-(1))
(2)Check that unit is horzontal.
Water pump and floating switch is installed inside indoor unit,check four corners of the unit for its lever using horizontal comparator or PVC tube with water.(If unit is tilting against the direction of water drainage,problem may occur on floating water leakage.)
Nut (Prepare in feild)
Washer (Prepared in feild)
In the case of ceiling already exists
(1)Install unit temporally
Put suspending bracket on the suspending bolt to hang the unit up.Be sure to use nut and washer at both end of the bracket to secure it firmly.
(2)Adjust the height and position of the unit.
(3)Proceed with procedure (4) of ì In the case of no ceiling ì
Suspending bolts
Fasten (double nuts) leveler
Polythene pipe
26
Insert
Washer fixing pad
(prepared in feild)
[ secure the washer firmly]
Installation Procedures
3.Installation of water drainage pipe
(1) Install water drainage pipe
Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size:
25mm; O.D.: 32mm )
Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming.
If downward slope of drainpipe cannot be made,lifting pipe shall be installed.
Keep a distance of 1-1.5m between suspending bolts, to make water hose straight.
1-1.5m
Slope over 1/100
Use the drainage hose and clip provided with unit.
Insert water pipe into water plug until it reaches the white tape.
Tighten the clip until head of the screw is less than 4mm from hose.
Wind the drainage hose to the clip using seal pad for heat insulation.
Insulate drainage hose in the room.
Large size seal pad
(accessory)
Clip
Clip
Tape(white)
Draingage hose
4mm below
Cautions for the water drainage lifting pipe
Installation height of water drainage lifting pipe shall be less than 280mm
There should be a right angle with unit ,300mm from unit.
Drainage hose
Suspending bracket
280mm unter
Water drainage lifting pipe
220mm
Drainage hose
Clip
< Note >
The slope of water drainage hose shall be within 75mm , make the drainage plug not to bear excessive force.
If several water hoses join together, of as per following procedures.
Slope below 1/100
Connection drainage hose with a T-joint
Specifications of the selected drainage hoses shall meet the requirements for the unit running
27
Installation Procedure
4. Installation of Ornament Panel
Install ornament panel on indoor unit
(1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and
check that the dimension of the ceiling opening is correct. Take off the lever gauge before install
the ornament panel.
(2)Fasten the screws to make the height difference between the two sides of indoor unit less than
5mm.
(3) First fix it with screws temporally.
(4) Fasten the two temporally fixing screws and other two, and tighten the four screws.
(5) Connect the wires of synchro-motor.
(6) Connect the wire of signal.
(7) If no response of remote controller,check whether the wiring is correct,restart remote controller
10 seconds after shut off power supply.
Drain hose
Pipe
Pipe
Display window
Limits of panel board installation
(1)Install the panel board in the direction shown in
the figure.
(2)The incorrect direction will result in water leakage,
meanwhile swing and signal receiving are displayed
that cannot be connected.
Louver motor
Liquid inlet pipe
Drain hose
Gas outlet pipe
28
Installation Procedures
Piping Connection
Flare connection
Gas pipe
Indoor
Unit
3-way valve
Outdoor unit
Liquid pipe
(1) Dimension of connecting pipe
Gas pipe
Liquid pipe
12.7mm
6.35mm
2-way valve
Flare connection
90 + 0.5
Fit the nut on and fasten
(2) The maximum length and drop height of connecting pipe
The maximum length is 10m
The maximum drop height is 5m.
To ensure the efficiency ,Pipes shall be as short as possible.
Spanner
Cautions for piping connection
Do not twist or deform the connecting pipe.
Do not mix dusts.
The bending radius shall be as large as possible.
Both gas pipe and liquid pipe shall be heat insulation.
No leakage in the flare.
Spanner
Joint
N u t
(3) Piping connection
Connecting method
Smear refrigerant oil on the joints of piping and flare.
The bending radius shall be as large as possible.
Align the pipe center when fastening, and tighten the nut, as shown in the figure.
Pay attention to not mix foreign matters such as sands in.
Diameter of Pipe
Liquid Pipe 6.35mm
Gas Pipe 12.7mm
Tighten Torque
18 N. m
50N. m
If not aligned ,tighten the nut by force will damage the nut that result in gas leakage
29
Installation Procedures
(4) Purging method ( the refrigerant is R407C)
To use vacuum pump
1
Detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose
(low) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump.
2-way valve
3-way valve
Liquid pipe
6.35mm(1/4'')
Gas pipe
15.88mm(5/8'')
Gaugemanifold
2
Open the handle at low in gaugemanifold, operate vacuum pump. If the scale-moves of gause (low) reach vacuum condition in a moment, check 1 again.
2 Open
Vacuum pump
3
Vacuumize for over 15min. And check the level gauge which should read -0.1 MPa (-76 cm Hg) at low pressure side. After the completion of vacuumizing, close the handle 'Lo' in gaugemanifold and stop the operation of the vacuum pump.
Check the condition of the scale and hold it for 1-2min.
If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of 3 .
3 Close
2-way valve
4
Open the valve rod for the 2-way valve to and angle of anticlockwise 90 degree.
After 6 seconds later, close the 2-way valve and male the inspection of gas leakage.
90
90
3-way valve
4
Service port
90 for 6 sec.
5
No gas leakage?
In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed steps.
6
6
Detach the charge hose from the service port, open
2-way valve and 3-way. Turn the valve rod anticlockwise until hitting lightly.
If it does not stop gas leakage, discharge whole refrigerants from the serice port.
After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder.
2-way valve
6
7
To prevent the gas leakage, turn the service port's cap, the valve rod'd cap for 2-way valve and 3-way's a lottle more than the point where the torque increases suddenly.
8
After attaching the each caps, check the gas leakage around the caps.
3-way valve
2-way valve
6
CAUTION:
If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.
3-way valve
7 Valve rod cap
7 Valve rod cap
7 Service port cap
If needing to recycle the refrigerant gas when installation or repair , please refer to the following procedures:
1. Cut off the power
2. (After confirming the power is cut off) pull the power cable plug terminals of the low-pressure pressure-switch out.
3. (After confirming the power cable terminals of the low-pressure pressure-switch is cut off) After powering on the unit again
and switch to COOLING mode,perform refrigerant gas recycling according to the normal refrigerant gas recycling procedure.
4. After finishing refrigerant gas recycling , cut off the power , then insert the power cable terminals of the low-pressure
pressure-switch properly.
30
Installation Procedures
Electrical Wiring
Cautions: Use copper wire only.Parameters of connecting line : H07RN-F 2x2.0mm
2
H05RN-F 2G0.75mm
2
for single cooling machine,H07RN-F 2x2.0mm
2
H05RN-F 4G0.75mm
2
for cooling and heating type machine.
Power supply :1PH,220-230V~,50Hz, connect from inside.
Wiring methods:
1.Wiring method of ring termianl
For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and tighten screw.
2. Wiring method of straight terminal
For connecting line which end is not a ring, its wiring method as follows: loosen wiring screw ans insert the end of connecting line totally into the terminal block,then tighten the screw and pull the connecting line slightly to confirm that it is clamped firmly.
Correct crimp connection of wire
1(L)
Wiring method of ring terminal
Incorrect crimp connection of wire
Terminal block
Crimp connection clamp
Crimp connection method of connecting line
After finishing wiring.connecting line must be fastened by wire clamp,which pressed on the external sheath of the connecting line, as shown in the right figure: wiring diagram for indoor and outdoor unit of cooling-heating type machine
Terminal block of indoor unit
1 2 3 4 5 N L
Wiring of indoor unit
Open air inlet grill
Take the leading end of connecting line
Connect connecting line according to wiring methods and wiring diagram of indoor and outdoor unit
Fasten connecting line according to crimp connection method of connecting line.
Reinstall air inlet grill.
Terminal block of outdoor unit
1 2 3 4 5 indoor unit casing wiring diagram for indoor and outdoor unit of single cooling type machine
Terminal block of indoor unit 1 2 3 4 5 N L
1.Installation fixing
Fix outdoor unit installation bracket on the wall using a
M10 anchor bolt.Fix outdoor unit on the installation bracket firmly using bot(M10) and nut, and keep it on horizontal level.
When installing on the wall or on the roof ,fix the bracket, firmly to prevent earthquake or storm.
Be sure to use rubber-damping cushion to reduce unit vibration.
Terminal block of outdoor unit 1 2 3 4 5 indoor unit casing
2.Installation of drain elbow
Installation of drain elbow.(Only for heat pump type air conditioner, no drain elbow for single cooling type).If use drain elbow,please install as shown in the figure.
Do not use drain elbow in cold place (temperature successively below 0 C)
3. Connection of outdoor piping
Connect the connecting pipe according to the piping connection method
4.Wiring connection
1.Open the wiring cover and loosen the wiring clamp.
2.Lead the connecting wire out and pass it through the wiring clamp.
3.Connect the connecting wire according to the wiring method and
diagram
4. Confirm the ends of wire are connected well, safe and correct.
5. After finishing wiring, press the connecting wire according to the
wire crimp connection method and reinstall the cover.
Drain eblow
Terminal
Wire clamp
Power supply
Connecting wire between inner and outer
1 2 3 4 5
Cooling and heating
Drain hose
1 2 3 4 5
Cooling
31
Installation Procedures,Check and Test Run
Other Instructions
1.Configuration of power supply
Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard.
In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together.
A leakage breaker must be installed.
Parameters of power supply: H07RN-F 3G 2.0
mm
2
Connection method is Y-connection .If the power cord is damaged, it must be replaced by professional people of manufacturer or its maintenance department or similar to avoid dangers.
2.Pipe cutting and expanding
Must remove burrs if cut pipes with pipe cutter.
Expand flare after insert the pipe expander.
Liquid pipe
Gas pipe
Diameter of pipe
6.35mm (1/4î)
12.7mm (1/2î)
Dimension A (mm)
0.8~1.5
1.2~2.0
A
Pipe expander
Correct Incorrect
Deflection Crack occurs Broken Incomplete Over outward
Installation check and test run
Require customers to use air conditioner according to the operation manual.
The items checked during test run,please mark in
No gas leakage on the pipe joint ?
How about the thermal insulation of the pipe joint:
Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly?
Is the wiring of indoor and outdoor unit secured firmly?
Is the drainage hose arranged correct?
Is the earthing wire connected firmly?
Is the power supply voltage conformed to the electrical regulation?
Any noise?
Is the display on the control board (LCD) correct?
Cooling normal?
Does the indoor temperature regulator work normally?
For the power supply
L shall be connected to the live wire.
N shall be connected to the neutral wire.
Shall be connected to the earth wire.
32
Contents
Cautions ...........................................................................................
1-2
Main points of operation..................................................................
3-4
Name of Each part ..........................................................................
5-7
Safety cautions................................................................................
8-9
Gaide to operation........................................................................
10-16
Maintenance .....................................................................................
17
Trouble shooting ..........................................................................
18-20
When trouble happens .....................................................................
21
Customer Need to know .................................................................
22
Installation Tools ..............................................................................
23
Installation Procedures ................................................................
24-31
Installation Procedures,Check and Test Run ....................................
32
CAUTIONS
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal.
The valuable materials contained in a air conditioner can be recycled.
Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental a w a r e n e s s b y i n s i s t i n g o n a n
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to t h e a s s e m b l y, o p e r a t i o n a n d maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill.
Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
1
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement