Versiton BAR70 M855 User Manual
Add to My manuals2 Pages
Versiton BAR70-M855: Your All-in-One Security Solution
The Versiton BAR70-M855 camera is a versatile and feature-packed device designed to meet your diverse security needs. With its advanced capabilities, you can effectively monitor and protect your property, both indoors and outdoors.
Key Features:
- Long Range Visibility: Capture clear images up to 70 meters indoors and 60 meters outdoors, ensuring wide coverage and detailed surveillance.
- Day & Night Functionality: Automatically switch between color and monochrome modes to provide optimal visibility in varying lighting conditions.
advertisement
IR WATERPROOF D&N CAMERA
BAR70-M855
MANUAL
FEATURE
1. Long visible range at night.(70m Max. indoors, 60m Max. outdoors)
2. You can select the level ofLED ON/OFF and filter change according to Lux as follow.
- Default Setting LED ON : Approx.5Lux,LED OFF : Approx.
10Lux
3. This camera adopts split glass technology to prevent IR light reflection.
4. This camera has vari-focal IR lens to prevent defocusing under IR lighting.
5. Day & Night Function(ICR) at night to receive maximum available light.
6. This product can match for any circumstances very well.
7. This product is suitable for 24 hours survillance with optical multicoating filter according to IR LED and CCD.
8. This product is "waterproof" to resist rain, snow and other weather factors.(IP67)
9. Sunvisor of this product can help the camera get the picture clearly.
10. This product is made of corrosion-free surface to resist rust and corrosion for a long time.
11. RS-485 interface.(Pelco-D, Pelco-P protocol support)
12. Support 4 different privacy zone
13. DWDR(Digital Wide Dynamic Range)
14. Multi function : High Light Mask, Lens Shading Compensation, Impact
Detection,Motion Detection
15. Multi-language full OSD support
16. Power & video cables are concealable.(Cable through bracket)
17. This camera adopts 3-axis bracket to install on the ceiling and wall.
18. You can connect 24V AC or 12V DC regardless polarity.
(Dual power version only)
19. This camera supports the advanced high resolution.
(700 TV- Line Color)
20. You can adjust the level of IR LED according to the circumstances.
IR LED output level controllable via RS-485.
21. A heater enables the camera to keep the proper operation at low temperature.(ON : 23 ℃ , OFF : 28 ℃ )
22. A fan enables the camera to keep the proper operation when the
LED is ON.
CAUTION
1. Please study the instruction manual before your applications and keep it for your future reference.
2. Do not flash LED light directly on the eyes when LEDs are on.
3. Do not install the camera on a unstable surface. It will cause falling or other hazards.
4. Do not use improper power, it could cause fire or electric shock.
(Use the AC adaptor 12V DC regulated, 2A.
Dual voltage product can use 24V AC adaptor.(option))
5. Do not disassemble or re-model the camera, it could cause fire, electric shock or other hazards.
6. Stop using the camera when you find a malfunction like smoke or unusual heat, it could cause fire or electric shock.
7. Due to the possibility of water leakage, do not cut or peel off the cable.
In case you cutor peel off the cable, the warranty will be void.
8. Do not adhere dangerous articles to the camera.
9. Do not leave the unit along with an unstable stand or table.
10. DC power cable or video cable should be always loose.
Do not keep the cables tight or twisted.
11. Please use the camera unit within given temperature and electricity limit.
12. Please make sure that installation should be done by qualified service person only.
13. Do not disassemble the unit by yourself. When there is problem with the unit please contact after-sale service center or the shop where you bought.
If the product is to be put out of operation definitively, take it to a local recycling plant for a disposal which is not harmful to the environment.
ACCESSORIES
ANCHOR 8x35 4EA
SCREW 6x35 TP1PAN SUS 4EA
WRENCH 5mm L TYPE 1EA
BOLT 1/4"-20UNC L=6, 1EA
INSTALLATION
<Ceiling mount>
Ceiling
ANCHOR 8x35 4EA
<Wall mount>
SCREW Tp16x35 4EA
ANCHOR 8x35 4EA
SCREW Tp16x35 4EA
Wall
Ø 30
63
Ø 30
ADJUST THE DIRECTION & OPEN/CLOSE CAP
Wall
WRENCH 5mm
Unlock
Lock
DIRECTION ADJUSTMENT
If you need function setting, open and close the cap by using the wrench.
※ After mounting the camera on a wall or ceiling
1. Loosen a bolt by using the wrench included.
2. Face the direction ofthe camera to monitor.
3. Tighten a bolt to complete adjustment.
SPECIFICATION
Model No.
Image Sensor
Effective Pixel
Cell Size
Resolution
TV Type
Sync. Type
Scanning System
Video Output
Gamma Characteristic
Min. Illumination
OSD
Motion Detection
Impact Detection
White Balace
Privacy Zone
Day & Night
RS-485 Protocol
S/N Ratio
Mirror
Backlight
Reverse Polarity Protection
Control Interface
Gain Control
Shutter
Test Illuminance Area
Power Supply
Current Consumption
Lens
LED
Operation Temp.
Preservation Temp.
Dimension
Weight
BAR70-M855
1/3" SONY SUPER HAD CCD Ⅱ
768(H) X 494(V) PIXEL(NTSC), 752(H) X 582(V) PIXEL(PAL)
6.35
㎛ (H) X 7.4
㎛ (V)(NTSC), 6.5
㎛ (H) X 6.25
㎛ (V)(PAL)
COLOR : 700 TV-Line, B/W : 750 TV-Line
NTSC / PAL
Internal
2:1Interlace
1.0 Vp-p(Sync. Negative) Termination 75 Ω ± 10%
γ = 0.45(Adjustable)
0.01Lux(F/1.2), 0Lux(LED HIGH, 70M Range)
Full OSD
ON / OFF Selectable(64 Zone)
ON / OFF Selectable(3 Step : LOW / MIDDLE / HIGH)
ATW / AWC / MANUAL
ON / OFF Selectable(4 Zone)
ICR(AUTO, COLOR, B/W)
PELCO-D&P
48dB over(AGC OFF)
ON / OFF
DWDR / BLC / HLC / OFF
YES
Extra Video connector for easy installation
Automatic(Adjustable)
1/60 ~ 1/100,000sec(NTSC), 1/50 ~ 1/100,000sec(PAL)
Average test illuminance by front view
12V DC, 24V AC Dual Voltage(option)
Max. 1.3A
Vari-focal auto iris day & night lens
IR LED 70EA
-10 ∼ 50 ℃
-20 ∼ 60 ℃
141.9(W) X 80.2(H) X 183.3(D)mm
Approx. 1.7kg
FUNCTION SETTING
1. OSD menu structure
Function setting menu Select menu
LENS
Sub menu
MANUAL, DC
1. EXPOSURE
BRIGHT
DC LEVEL
E.SHUTTER
AGC
DWDR
BLC
HLC
HLC THR
Contents
0 ~ 100
0 ~ 20
AUTO
1/60(1/50) ~ 1/100,000
OFF, LOW,
MIDDLE, HIGH
OFF, LOW, MIDDLE, HIGH
OFF, ON
OFF, ON,
AUTO
0 ~ 100
Fixed focal lens or Vari-focal auto iris lens
In case of manual lens selection, adjust the brightness
In case of DC lens selection, adjust the brightness
Shutter speed auto adjustable
Select shutter speed manually
Determines that use the AGC function or not and AGC level selectable(You can not use the
Auto D&N change mode when AGC is off)
Digital Wide Dynamic Range
BLC function
High Light Mask function
In case of AUTO mode, the function will off in daytime and on at night
According to the threshold value, the camera will recognize as High light or not.
※ All specification is subject to change without notice to improve the quality.
2. WHITE
BALANCE
3. DAY&NIGHT
4. IMAGE
ADJUST
5. MOTION &
IMPACT
6. PRIVACY
MASK
7. COMMUNI-
CATION
8. SPECIAL
9. FACTORY
SET
10. EXIT
AWB MODE
D&N MODE
BURST
COLOR
B&W →
→ B&W
COLOR
DELAY TIME
ATW
MANUAL
AWC
AUTO
COLOR
B&W
↓
OFF, ON
85 ~ 170
50 ~ 135
3 ~ 15
Color temperature 2500 ~ 9500°K
Adjust the Red or Blue values to shift the color of the object
Move the camera lens toward to white paper then press the set button to find the optimal white balance for current environment
Auto day&night switching mode
Fixed at color(LED OFF)
Fixed at B/W(LED ON)
Determines whether to transmit the burst signal or not in B/W mode
You can select brightness of illumination about changing the day ↔ night mode
You can select the duration time about chaining the day ↔ night mode
LED LEVEL(IN/OUT)
DYNAMIC IR
MIRROR
SHARPNESS
GAMMA
LSC
LSC LEVEL
R-Y GAIN
B-Y GAIN
PATTERN
GENERATOR
MOTION
DISPLAY
OFF, LOW, MIDDLE, HIGH
OFF, ON
IR LED OFF/ON and output level adjustable
When IR LED is turned on in B/W, the objects can be clearly identified due to the function that decreases screen saturation of objects within a short distance.
Set a horizontal image inversion OFF, ON
0 ~ 50
0.45, 0.6, 1, USER
OFF, ON
Sharpness adjustable
Gamma adjustable
Determines whether to use the brightness compensation offour lens'corners(LSC) or not
The LSC level selectable 0 ~ 50
0 ~ 200
0 ~ 200
Adjust Red tone of the image
Adjust Blue tone of the image
Test signal. Press the set button, color bar appeared on the screen and press any key to return to menu
OFF, ON
Determines whether to use the motion detection function or not
NONE
MESSAGE
No display on the screen though movement is detected
The words 'MOTION' appear on the screen when movement is detected
SET
WINDOW
MASK
Motion detection area appear on the screen when movement is detected
Press the set button to move into the motion detection area section to set the 64 areas. Press the set button for a few second to move out
Press the set button to select all area ALL SET ↓
ALLCLEAR ↓
SENSITIVITY
HOLD TIME
IMPACT
HOLD TIME
MASK
1, 2, 3, 4
Press the set button to remove all area
0 ~ 255 Motion detection sensitivity
1~ 15
OFF, LOW,
MIDDLE, HIGH
Set the duration of outside alarm. If the way of display is message, it means display time of message
Determines whether to use impact detection function or not and sensitivity setting
1~ 15
OFF, ON
BLACK, GRAY…
Set the duration of outside alarm and display time of "IMPACT" message
Display each privacy mask or not. Press the set button to move into the privacy mask setting section, whenever you press the set button, the mask color is changed. When the mask color is red you can adjust the size by up, down, left and right button. When the mask color is blue you can set the position of mask by up, down, left and right button. Press the set button for a few second to escape
Select mask color MASK COLOR
CAM ID
BAUDRATE
PROTOCOL
1~ 255
2400 ~ 9600
PELCO-D, PELCO-P
Select the camera ID for RS-485 communication
Select baud rate
Select protocol
※ If you change the COMMUNICATION value through RS-485, you might not control the camera due to unmatched value(If your camera is out of working due to above reason, change your controller's value or wait a few minute till close the menu, it will be back to previous setting value)
LANGUAGE
NAME DISPLAY
EDIT
ENGLISH, … Select language
OFF, ON Display the camera ID on the screen
Press the set button to move into the name setting section. You can choose the letter by using up and down button and move next letter by using left and right button. Press the set button for a few second to move out
POSITION
Press the set button to move into the position setting section.
You can move the camera ID to your wanted position by using up, down, left and right button
To reset your camera to factory default condition
Notice : Lens, communication and language is not changed
Save the value and then restart
2. How to use the jog lever & Zoom/Focus trimmer
7
6
4
2
3
5
1
8
Focus & Zoom fixing screw
Focal length adjustment direction
1. Unfasten the '+' type screw inside
2. Adjust two trimmers properly
3. Tighten the scew
<Caution> When you tighten the screw, don't put stress excessively.
① Enter :
ㆍ Push the lever : Used to access the menu and confirm selection.
ㆍ Push the lever for one second : Used to return to previous menu from the motion detection setting section or privacy mask setting section.
② UP, ③ DOWN : Used to move the cursor to up or down.
④ LEFT, ⑤ RIGHT : Used to move the cursor to left or right and change the value.
⑥ EXT. VIDEO : Extra video output terminal for installation.
Plug your test monitor in hear. The cable is option.
⑦ Zoom, ⑧ Focus : Use a '+' type driver for adjusting zoom and focus.
3. How to control through RS-485 communication
1) Match the camera with controller's ID, baudrate and protocol
2) Up, Down, Left and right of Jog lever is same as Up, Down, Left and right of RS-485 controller
3) Enter of Jog lever is the same as menu key or IRIS open key of
RS-485 controller
4) Return to previous menu from motion detection setting section and privacy mask setting section : Iris close or Iris open for a few second. Or press the button as Up → Right → Down →
Left successively
4. Cable array (RS-485, ALARM)
A : BLUE(MOTION)
B : BLACK(GND)
C : GREEN(IMPACT)
D : BLACK(GND)
E : ORANGE(RX +)
F : WHITE(RX -)
E
F
C
D
No.
A
B
FUNCTION
MOTION ALARM
GND
IMPACT ALARM
GND
RX +
RX -
REMARK
ㆍ If the camera detected motion when using Motion & Impact function, outside line of motion alarm connect with GND(B).
ㆍ If the camera detect impact, outsie line of impact alarm connect with GND(D).Outputs of Motion & Impact are 'open collector'.
ㆍ Max current & voltage are 200mA and 30V DC.
RS-485A
RS-485B
<Caution> All connectors must be securely sealed to prevent water leakage, especially for un-used wires.
advertisement
Related manuals
advertisement