Dizmax Technology DOIRP3000F Manual
Add to My manuals2 Pages
Dizmax Technology DOIRP3000F is a 3-axis IR dome camera offering versatile installation options for ceiling, wall, or slope mounting. With its 14 IR LEDs, it provides clear visibility in total darkness up to 15 meters. It features advanced functionalities like multi-language OSD, 4 different privacy zones, and multiple detection modes, including motion and impact detection. The camera supports RS-485 interface for Pelco-D and Pelco-P protocols, allowing for remote control and integration with surveillance systems.
advertisement
3- AXIS IR DOME CAMERA
DOIRP3000F
MANUAL
2. Removing the dome : Lift the dome. When you push the latch button, it is unlocked and you can lift the dome.
◐
PRECAUTION
1. Do not install the camera outdoors.
2. Choose an ideal location for the camera, since a camera unit must be protected against moisture and vibration.
3. Be careful not to scratch the camera unit, especially lens or dome cover.
4. Use the camera within the temperature(- 10 ~ +50).
5. Handle with care. Dropping it can cause serious damage to the camera.
6. Avoid any direct sun light toward the lens.
7. Use the AC adaptor 12V DC, 500mA regulated.
◐
FE ATURES
1. This camera is incredibly flexible to install with its 3- axis camera construction, which makes the camera ceiling, wall or slope mountable.
2. 15M range visible in tatal darkness with 14pcs of IR LED
3. RS- 485 interface(Pelco- D, Pelco- P protocol support) : option
4. Advanced High Resolution(600 TV- Line) : option
5. Support 4 different privacy zone
6. IR LED output level controllable via RS- 485
7. DWDR(Digital Wide Dynamic Range)
8. Multi function : High Light Mask, Lens Shading Compensation, Impact
Detection, Motion Detection
9. Multi- language full OSD support
◐
HOW TO INSTALL
1. Opening the dome : Pushing the latch button.
< C aution > Remove the protection sheet after installing.
PROTE CTION S HEET
LATCH BUT TON
3. Camera installation :
(1) Fix the camera set with the s upplied screws on ceiling or wall mount. If you don't use supplied screws, the camera may fall off.
(2) Please refer to '4. Camera angle adjustment' regarding adjust camera angle.
(3) Re- assemble the camera.
<Ceiling mount>
SCREW TP13.5x20 2EA
<Wall mount>
SCREW TP13.5x20 2EA
4. Camera angle adjustment :
(1) Pan adjustment : Grasp the disk of camera and then adjust
(2) Tilt adjustment : Grasp the led cover of camera and then adjust
(3) Roll adjustment : Grasp the camera holder and then rotate
<Caution> If you try to adjust the camera out of limited angle, it might cause troubles and damage to camera.
LED COVER
DISK
L
R
U
CAMERA HOLDER
D ROTATION
DIMENSION
Ø 85
ASSEMBLY
Ø 110
HARNESS
SCRE W
BUSHING RUB BER
SC REW
Ø 84
BODY
DOME COVER
BOARD CAMERA AS S'Y
SC REW
CONTROL PCB
DISK
PUSH BUTTON
CABLE
BASE
If the product is to be put out of operation definitively, take it to a local recycling plant for a disposal which is not harmful to the environment.
◐
SPECIFICATION
Model No.
Image Sensor
Effective Pixel
Cell Size
Resolution
TV Type
Sync. Type
Scanning System
Video Output
Gamma Characteristic
Min. Illumination
OSD
Motion Detection
Impact Detection(option)
White Balace
Privacy Zone
Day & Night
RS- 485 Protocol
S/N Ratio
Mirror
Backlight
Reverse polarity protection
Control Interface
Gain Control
Shutter
Test Illuminance Area
Power Supply
Current Consumption
Lens
LED
Operation Temp.
Preservation Temp.
Dimension
Weight
DOIRP3000F
1/3" SONY SUPER HAD CCD Ⅱ
768(H) X 494(V ) PIXEL(NTSC)
752(H) X 582(V) PIXEL(PAL)
6.35
㎛ (H) X 7.4
㎛ (V)(NTSC)
6.5
㎛ (H) X 6.25
㎛ (V)(PAL)
700 TV- Line
NTSC / PAL
Internal
2:1 Interlace
1.0 Vp- p(Sync. Negative) Termination 75Ω ± 10 %
γ = 0.45(Adjustable)
0 Lux(15M Range) : LED ON
0.1Lux(F/1.2) : LED OFF
Full OSD
ON / OFF Selectable(64 Zone)
ON / OFF Selectable(3 Step : LOW / MIDDLE / HIGH)
ATW / AWC / MANUAL
ON / OFF Selectable(4 Zone)
Electronic D&N(AUTO, COLOR, B/W)
PELC O- D&P
48dB over(AGC OFF)
ON / OFF
DWDR / BLC / HLC / OFF
YES
Extra Video connector for easy installation
Automatic(Adjustable)
1/60~ 1/100,000sec(NTSC), 1/50~ 1/100,000sec(PAL)
Average test illuminance by front view
Regulated 12V DC ± 10%
Max. 300mA(at 12V DC)
Fixed focal lens
IR LED 14EA
- 10 ∼ 50 ℃
- 20 ∼ 60 ℃
Ø 110 × 80(H)mm
Approx. 230g
◐
FUNCTION SETTING
1. OSD menu structure
Func tion setting menu S elect menu
LENS
Sub menu
MANUAL, DC
BRIGHT 0 ~ 100
1. EXPOSURE
DC LEVEL
E.SHUTTER
AGC
DWDR
BLC
HLC
HLC THR
0 ~ 20
AUTO
1/60(1/50) ~ 1/100,000
OFF, LOW,
MIDDLE, HIGH
OFF, LOW, MIDDLE, HIGH
OFF, ON
OFF, ON,
AUTO
0 ~ 100
Contents
Fixed focal lens or Vari- focal auto iris lens
In case of manual lens selection, adjust the brightness
In case of DC lens selection, adjust the brightness
Shutter speed auto adjustable
Select shutter speed manually
Determines that use the AGC function or not and AGC level selectable(You can not use the
Auto D&N change mode when AGC is off)
Digital Wide Dynamic Range
BLC function
High Light Mask function
In case of AUTO mode, the function will off in daytime and on at night
According to the threshold value, the camera will recognize as High light or not.
※ All specification is subject to change withoutnotic e to improve the quality.
2. WHITE
BALANCE
3. DAY&NIGHT
4. IMAGE
ADJUST
5. MOTION &
IMPACT
6. PRIVACY
MASK
7. COMMUNI-
CATION
8. SPECIAL
AWB MODE
D&N MODE
BURST
COLOR
→
→ B&W
B&W COLOR
DELAY TIME
LED LEVEL
DYNAMIC IR
MIRROR
SHARPNESS
GAMMA
LSC
ATW
MANUAL
AWC ↓
AUTO
COLOR
B&W
Color temperature 2500 ~ 9500°K
Adjust the Red or Blue values to shift the color of the object
Move the camera lens toward to white paper then press the set button to find the optimal white balance for current environment
Auto day&night switching mode
Fixed at color(LED OFF)
Fixed at B/W(LED ON)
OFF, ON
85 ~ 170
50 ~ 135
3 ~ 15
Determines whether to transmitthe burst signal or not in B/W mode
You can select brightness of illumination about changing the day ↔ night mode
You can selectthe duration time aboutchaining the day ↔ nightmode
IR LED OFF/ON and output level adjustable OFF, LOW, MIDDLE, HIGH
OFF, ON
OFF, ON
0 ~ 50
0.45, 0.6, 1, USER
OFF, ON
When IR LED is turned on in B/W, the objects can be clearly identified due to the function that decreases screen saturation of objects within a short distance.
Set a horizontal image inversion
Sharpness adjustable
Gamma adjustable
Determines whether to use the brightness compensation of four lens' corners(LSC) or not
0 ~ 50
0 ~ 200
0 ~ 200
The LSC level selectable
Adjust Red tone of the image
Adjust Blue tone of the image
Test signal. Press the set button, color bar appeared on the screen and press any key to return to menu(SK- D385IR/M843 only)
OFF, ON
LSC LEVEL
R- Y GAIN
B- Y GAIN
PATT ERN
GE NERATOR
MOTION
NONE
No display on the screen though movement is detected
DISPLAY
SET
WINDOW
ALL SET ↓
ALLCLE AR ↓
SENSITIVITY
HOLD TIME
IMPACT
HOLD TIME
MESSAGE
MASK
Motion detection area appear on the screen when movement is detected
Press the set button to move into the motion detection area section to setthe 64 areas. Press the set button for a few second to move out
Press the set button to select all area
Press the set button to remove all area
0 ~ 255
1 ~ 15
Motion detection sensitivity
Set the duration of outside alarm. If the way of display is message, it means display time of message
OFF, LOW,
MIDDLE, HIGH
1 ~ 15
Determines whether to use impact detection function or not and sensitivity setting
Set the duration of outside alarm and display time of "IMPACT" message
Display each privacy mask or not. Press the set button to move into the privacy mask
MASK
1, 2, 3, 4
OFF, ON button, the mask color is changed. When the mask color is red you can adjust the size by up, down, left and right button. When the mask color is blue you can set the position of mask by up, down, leftand right button. Press the setbutton for a few second to escape
Select mask color
Selectthe camera ID for RS- 485 communication
MASK COLOR
CAM ID
EDIT
BLACK, GRAY…
1 ~ 255
BAUDRATE
PROTOCOL
2400 ~ 9600
PELCO- D, PELCO- P
Select baud rate
Select protocol
※ If you change the COMMUNICATION value through RS- 485, you might not control the camera due to unmatched value(If your camera is out of working due to above reason, change your controller's value or wait a few minute till close the menu, it will be back to previous setting value)
LANGUAGE
NAME DISPLAY
ENGLISH, …
OFF, ON
Select language
Display the camera ID on the screen
Press the set button to move into the name setting section. You can choose the letter by using up and down button and move
9. FACTORY
SET
10. EXIT
POSITION
Press the set button to move into the position setting section.
You can move the camera ID to your wanted position by using up, down, left and right button
To reset your camera to factory default condition
Notice : Lens, communication and language is not changed
Save the value and then restart
2. How to use the jog lever
6
2
4 5
1
① ENTER :
3
ㆍ Push the lever : Used to access the menu and confirm selection.
ㆍ Push the lever for one second : Used to return to previous menu from the motion detection setting section or privacy mask setting section.
② UP, ③ DOWN
④ LEFT, ⑤ RIGHT
: Used to move the cursor to up or down.
: Used to move the cursor to leftor right and change
⑥ the value.
EXT- VIDEO : Extra video output terminal for installation.
Plug your test monitor in hear. The cable is option.
3. How to control through RS- 485 communication (option)
1) Mat ch the camera with controller's ID, baudrate and protocol
2) Up, Down, Left and right of Jog lever is same as Up, Down, Left and right of RS- 485 controller
3) Enter of Jog lever is the same as menu key or IRIS open key of
RS - 485 controller
4) Return to previous menu from motion detection setting section and privacy mask setting section : Iris close or Iris open for a few second.
Or press the button as Up Right Down Leftsuccessively
1) No impact & motion alarm type
E : ORANGE(RX +)
F : WHITE(RX - )
2) Built- in impact & motion alarm type
A : BLUE(MOTION)
B : BLACK(GND)
C : GREEN(IMPACT)
D : BLACK(GND)
E : ORANGE(RX +)
F : WHITE(RX - )
A
B
C
D
E
F
No.
FUNCTION
MOTION ALARM
GND
IMPACT ALARM
GND
RX +
RX -
REMARK
ㆍ If the camera detected motion when using Motion & Impact function, outside line of motion alarm connect with GND(B).
ㆍ If the camera detect impact, outsie line of impact alarm connect with GND(D).Outputs of Motion & Impact are 'open collector'.
ㆍ Max current & voltage are 200mA and 30V DC.
RS- 485A
RS- 485B
advertisement
Related manuals
advertisement