INSTALLATION & OPERATING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
36026.0000J 12/06 ©2003 Bunn-O-Matic Corporation
www.bunn.com
CONTENTS
Warranty .......................................................................... 2
Introduction ..................................................................... 3
User Notices .................................................................... 3
Electrical Requirements ................................................... 4
Plumbing Requirements .................................................. 5
Initial Set-up .................................................................... 6
Electrical Hook-up ............................................................ 6
Plumbing Hook-up ........................................................... 6
Setting Dispenser Flow Rate ............................................ 7
Selecting the Correct Pump Tubing .................................. 8
Operating Controls & Interface ........................................ 9
Initial Fill & Heat ............................................................. 10
FlavorGard™ Feature ...................................................... 11
Rinse Alarm Feature ....................................................... 11
BIB Empty Lockout Feature ............................................ 12
Brew Temperature Lockout Feature ................................ 12
Programming the Dispenser .......................................... 13
Loading the Concentrate ................................................ 19
Priming the Concentrate Lines ....................................... 19
Operating the Pull & Hold Dispenser .............................. 20
Operating the Preset Portion Control Dispenser ............ 21
Filling Cambros or other large containers ...................... 21
Cleaning & Preventive Maintenance ............................... 22
Replacing the Pump Tubing ........................................... 23
Draining the Hot Water................................................... 24
Troubleshooting ............................................................. 25
Field Calibration of the Concentrate Pumps ................... 30
Dispenser Flow Rate Calibration .................................... 31
Field Calibrating the Hot Water Flow Rate ...................... 31
Field Calibrating the Empty BIB Warning ........................ 32
Schematic Wiring Diagrams ........................................... 33
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) All equipment other than as specified below: 2 years parts and 1 year labor.
2) Electronic circuit and/or control boards: parts and labor for 3 years.
3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227,
Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS
EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION
AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
BUNN, LCR-2 and LCR-2 PC are either trademarks or registered trademarks of Bunn-O-Matic Corporation.
2 36026 121506
ELECTRICAL REQUIREMENTS
CAUTION: The dispenser must remain disconnected from power source until specified in Electrical Hook-Up.
The LCR-2 dispenser is supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for 120 volts AC, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R.
The LCR-2C dispenser is supplied with a 120-volt / 20 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for 120 volts AC, 20 amp, single phase, 60Hz. The mating connector must be a NEMA 5-20R.
These dispensers can be Field Wired for 208 or 240 volt applications. This requires a 2 or 3-wire, grounded, individual branch circuit rated for 208/240 volts AC, 30 amp, single phase, 60 Hz.
NOTE: The internal terminal block must be rewired for 208/240 applications, (see Optional Field Wiring Diagram).
HEATER RED
10A. FUSE - WHITE
HEATER RED
10A. FUSE - WHITE
10A. FUSE - BLACK
LIMIT SW. - BLACK
120V A.C.
208 or
240V A.C.
120V A.C.
208 or
4
ELECTRICAL REQUIREMENTS (Cont.)
CAUTION: The dispenser must remain disconnected from power source until specified in Electrical Hook-Up.
The LCR-2A 3 Phase dispenser is internally wired from the factory for 400 Volts AC Phase to Phase, 230 Volts
AC Phase to Neutral, 3 Phase 50/60 Hz. It requires a 4-wire, grounded, individual branch circuit rated for 400
Volts AC, Three Phase, 50/60 Hz. At Three Phase operation, each Phase will have approximately 13.5-14.0
Amps flow through it.
The LCR-2A 3 Phase dispenser can be Field Wired for 230 Volts AC, Single Phase applications. This requires a 2-wire, grounded, individual branch circuit rated for 230 volts AC, Single Phase, 50/60 Hz. At Single Phase operation, the machine will have approximately 27.5 Amps flow through it.
NOTE: The internal terminal block must be rewired for 230 Volts AC, Single Phase applications, (see Optional
Field Wiring Diagram).
BRN
BRN
TERMINAL
RED
BLU BLU
FOR 3-PHASE OPERATION
CONNECT INPUT WIRING TO
L1,L2,L3 & N AS SHOWN.
PLUMBING REQUIREMENTS
The dispenser may be connected to a cold or hot water system (140°F Max.) with operating pressure between
20 and 90 psi (138 and 620 kPa) from a 1/2” or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to
50 psi (345 kPa). The water inlet fitting is 3/8” flare. Dispensers set up to deliver to 1.8 Oz./sec. (53.2 ml/sec) per dispense tip, require a water supply source that can deliver a minimum of 1.7 gpm (6.4 lpm) at the inlet fitting. Dispensers set up to deliver 2.6 Oz./sec. (76.9 lpm) per dispense tip, require a water supply source that can deliver a minimum of 2.4 gpm (9.2 lpm) at the inlet fitting.
NOTE: Bunn-O-Matic recommends 3/8” tubing from the 1/2” water supply line. At least 18 inches of FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the
Food and Drug Administration (FDA). For models installed outside the U.S., you must comply with the applicable Plumbing/Sanitation Code for your area.
5 36026 121506
INITIAL SET-UP
NOTE: The LCR-2 dispenser weighs approximately 100 lbs. (45 kg). If necessary, use more than one person when lifting or moving the dispenser.
1. Cut the two straps and remove the box and foam packing.
2. Locate and remove the information packets and tube kits from top of packaging and set aside.
3. Open the dispenser door and remove the drip tray and the lower splash guard panel.
4. Set dispenser on the counter where it is to be used. CAUTION: DO NOT LIFT ON THE DOOR.
5. Confirm the dispenser is level on the counter (See LEVELING THE DISPENSER).
ELECTRICAL HOOK-UP
CAUTION: Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified in conformance with all local, state and federal electrical codes.
2. Using a voltmeter, check the voltage and color-coding of each conductor at the electrical source.
3. Connect the dispenser to the power source.
4. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing has been hooked up, the dispenser is ready for Initial Fill & Heat.
PLUMBING HOOK-UP
1. Flush the water line to remove any debris or foreign material.
2. Securely attach the water line to the 3/8” flare fitting, on bottom right side of the dispenser.
3. Turn on the water supply and check for leaks.
LEVELING THE DISPENSER
Proper leveling of the dispenser is required to insure proper drainage of condensation from the refrigeration unit.
1. Set the dispenser on a level counter top.
2. Use the adjustable legs to level the dispenser on all four corners.
3. Once the unit is level, adjust the front two legs out another 1/16” to create a slight tilt towards the rear of the dispenser. (See Fig. 1)
6 36026 101703
SETTING DISPENSER FLOW RATE
The dispenser comes from the factory with flow restrictors in the mix chambers. With the restrictors in place the dispense rate is about 1.8 oz./sec (53.2 ml/sec) and is used primarily for cup at a time dispensing. The flow restrictors can be removed to increase the dispense rate to about 2.5 oz./sec (74 ml/sec) for larger volume dispensing (airpots, carafes, etc.).
NOTE: The hot water FlowRate is fixed at approximately 1.7 oz/sec. and can not be adjusted.
Removing the restrictors:
1. Disconnect the dispenser from the AC power source.
2. Open the Product Cabinet door.
3. Remove the concentrate tube, vent line and grommet from mix chamber ports in side the product cabinet.
4. Remove the two screws that fasten mix chamber to the control panel.
5. Gently pull mix chamber away from dispenser to expose water line connection, (you may have to rotate it slightly).
6. Disconnect FlavorGard™ sensor wire and hot water tubing from the mix chamber.
7. Remove the flow restrictor from the inlet to the mix chamber.
8. Reconnect FlavorGard™ sensor wire and hot water tubing to the mix chamber.
9. Place mix chamber back into position in the dispenser, (you may have to rotate it slightly) and secure it with the two screws
10. Reposition the grommet, vent line and pump tubing onto the mix chamber ports.
Caution: Failure to properly replace and secure any of the above components may result leaks and/or cause damage to the dispenser.
If you changed the Dispenser Flow Rate, you will need to reprogram the dispenser to the new rate, see Programming the Dispenser.
CAUTION: Failure to reprogram the Dispenser Flow Rates will result in inaccurate Mix Ratios.
Reprogramming the Dispenser Flow Rate:
1. Remove the lower splash guard panel and locate the Programming module.
2. Use the Down Arrow key to enter into the programming function and scroll through the menu’s to the “CAL
LEFT SIDE?” menu and select “YES”.
3. Scroll down to the “CAL LF WTR VOL” menu
4. Use the (+) & (-) keys to enter a volume of 50 Oz. (1478 mL). This will recalibrate the Left dispenser to the new rate.
5. Scroll down to the “CAL RT WTR VOL” menu
6. Use the (+) & (-) keys to enter a volume of 50 Oz. (1478 mL). This will recalibrate the Right dispenser to the new rate.
7. Select “Exit” to leave the programming menu.
Note: The default volume of 50 Oz (1478 mL), is the typical Cal Volume for a 2.5 Oz/sec Flow Rate Test, see Field
Calibration of the Concentrate Pumps / Dispenser Flow Rates.
7 36026 120105
SELECTING THE CORRECT PUMP TUBING
There are two pump tube sizes available for use with this dispenser. To determine the correct tubing for your application, first determine the dispenser flow rate you intend to use, refer to Setting Dispenser Flow Rate . Then look up the recommended tube size for the mix ratio of your concentrate, refer to the Tube Selection Chart.
TUBE SELECTION CHART
Dispense Concentrate Ratios
Rate 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
1/8” I.D. TUBING 1.8 Oz/sec. 3/16” I.D. TUBING
(53 ml/sec.)
2.5 Oz/sec. 3/16” I.D. TUBING
(74 ml/sec.)
1/8” I.D. TUBING
Examples:
1. For a Dispenser Flow Rate of 2.5 Oz./sec (74 mL/sec) and a Mix Ratio of 35:1 – use 3/16” I.D. Tubing.
2. For a Dispenser Flow Rate of 1.8 Oz./sec (53 mL/sec) and a Mix Ratio of 60:1 – use 1/8” I.D. Tubing.
Tube kits can be purchased from BUNN-O-MATIC.
Part # 34727.1000 for 3/16” I.D. Tubing or #34728.1000 for 1/8” I.D. Tubing.
INSTALLING THE PUMP TUBING (Refer to the Tubing Installation Instructions in side the cabinet door for details.)
1. Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set it and the retainer plate aside.
2. Depress the tension screw and remove it from the notch in the pump body, releasing the spring tension on the pump band.
3. Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing.
4. Insert the tubing onto the mix chamber port and wrap the tubing around the pump rotor, making sure that the elbow and clamps end up on the bottom side of the pump body.
5. Close the compression band reinsert the tension screw into the notch in the pump housing.
6. Replace the tubing retainer plate and tighten the thumbscrew.
7. Reconnect bag connector to the product box.
8. Repeat steps 1 through 7 for the other pump.
9. Prime the pumps. Refer to Priming the Concentrate Lines section.
Thumbscrew
Tension
Screw
Remove Retaining Plate Release Spring Tension Remove Tubing
2.0”
2.0”
Lubricate between arrows
Lubricate New Tube
Tension Screw
Tube Clamp
Install New Tubing
8
Completed Installation
36026 101703
OPERATING CONTROLS AND INTERFACE
1a. Dispense Handles: Pull and Hold to dispense product.
1b. Dispense Switches: Push and Release to dispense product for Portion Control Models.
2. Stop Switch: Momentary switch stops all dispense functions.
3a. Hot Water Switch: Push and Hold switch to dispense hot water from the center dispense tip.
3b. Push and Release switch for Portion Control Models.
4. Alternate Portion Control Switch: Momentarily pushed to select the Alternate Portion Control Volume #2.
5. Function Selector Switch: Allows the user to set the dispenser into different dispensing modes.
a. Rinse: Dispenses hot water only- Flushes the mix chamber and dispense tip.
b. Prime: Dispenses concentrates only – Primes the concentrate pump.
c. Normal: Normal dispense mode - Dispenses mixed product (concentrate and water).
6. Mode Selector Switch: Allows the user to set the dispenser into different operating modes.
a. Run: Normal operating position.
b. Off: Turns off all functions including tank heater and chiller.
WARNING - The OFF Mode does not remove AC power from the dispenser. Disconnect power source before servicing the dispenser c. Night: Anti-pilfering mode that disables dispensing, but keeps the tank heater and chiller (if applicable) operational.
7. Door Interlock Switch: Unit will not dispense product if the door is open.
8. Power LED: Red - illuminates when AC power is applied to dispenser.
9. Ready LED: Green - illuminates when the water is at the preset ready temperature.
10. Portion LED: Yellow - illuminates when the portion dispense option has been selected, (5 second delay).
11. Rinse LED: Yellow - illuminates when the optional preset rinse alarm time has elapsed.
12. Left Refill LED: Yellow - illuminates when the Left Concentrate BIB needs replaced.
13. Right Refill LED: Yellow - illuminates when the Right Concentrate BIB needs replaced.
14. Programming Keypad: Used in conjunction with the LCD display to program and calibrate the dispenser to customer specific requirements. (Located behind the splash guard panel)
15. LCD Display: Displays programming menus and fault messages. (Located behind the splash guard panel)
5 6
8
7
9
1
4
BUNN ICED COFFEE
AMBIENT UNIT
12
15
14
13
2
10
11
3
9 36026 120105
INITIAL FILL & HEAT
1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.
2. Confirm the water supply is on.
3. Connect the dispenser to the power source. The Red POWER LED will illuminate and water will begin flowing into the tank. The dispenser will automatically stop filling when the tank is full. The dispenser will not begin heating the water until after the tank is filled. Dispenser models with product chillers will begin to cool the cabinet at this time.
4. The Green READY LED will illuminate when the tank temperature reaches the preset ready temperature.
Note: The time required to heat the water initially will vary depending on the AC Power supplied to the dispenser.
While the tank is heating, the dispenser may be readied for use as described in Programming Functions & Basic
Operations.
1 1
3
4
10 36026 101703
FlavorGard™ Feature
FlavorGard™ is a patented feed back control loop that monitors the mixed product and adjusts the concentrate delivery rate to maintain a consistent mix profile, i.e. Flavor Profile. The system consists of a conductance probe mounted in the final stages of the mixing chamber, a metering pump with RPM sensor and a digital controller.
Once you have completed the installation of the dispenser, entered the desired mix ratio for your concentrate, dispensed several cups of the mixed product, and are satisfied with the Flavor and Strength being delivered, simply enable FlavorGard™, (refer to FlavorGard™ in Programming the Dispenser ).
The dispenser will automatically calibrate the system to all the factors that make up your particular mix profile,
(e.g. water source, filtration system, Brand of concentrate and mix ratio selected, etc.).
NOTE: It is very important that you have dispensed enough product to insure that the dispenser is fully functional and you are satisfied with the Flavor Profile of the mix product before enabling FlavorGard™.
Once FlavorGard™ is enabled, the dispenser will continuously monitor the mix product as it is being dispensed and adjust the metering pump speed to maintain a consistent mixed product, thus eliminating factors such as
(settling of the concentrate, tube wear, viscosity changes, liming, etc.).
The system is designed to work with in the range of variations that can be caused by these factors. The factory preset range is (+/- 10 %) and is adjustable to a Max of (+/- 15%). This insures that the FlavorGard™ system is not responding to factors that cannot be corrected by minor adjustments to the speed of the metering pump,
(e.g. kinked hoses, low water pressure, severely worn tubes, empty BIB’s, etc).
NOTE: Changes to Concentrate Ratios or Dispenser Flow Rates will automatically disable FlavorGard™.
You will need to re-enable FlavorGard™, once you are satisfied with the new Flavor Profile.
Rinse Alarm Feature
Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispenser. The automated Rinse Alarm feature has three levels of operation, Disabled, Warning
Only and Warning with Brew Lockout, see chart for details.
Alarm Level Selected
Disabled
Warning Only
Alarm Mode
None
Rinse LED will come on 4 hrs prior to the selected time interval and remain on until the Rinse procedure has been performed. The dispenser will continue to serve product.
Warning w/ Brew Lockout Rinse LED will come on 4 hrs prior to the selected time interval and remain on until the Rinse procedure has been performed. The dispenser will Lockout and not continue to serve product once the selected time interval has elapsed.
NOTE: The time interval between Rinses is adjustable from 8 to 24 hrs.
The dispenser is shipped with the automated Rinse Alarm disabled, (No Alarm). It is up to the user to determine the
Rinse time interval and the level of warning required, based on their application and maintenance procedures.
To enable the automated Rinse Alarm feature, refer to RINSE ALARM ? in Programming the Dispenser.
11 36026 101703
Rinse Procedure:
1. Open the cabinet door and select Rinse on the Function Selector switch – close the door.
2. Place a 2 Liter (1/2 Gal) container under the Left dispense tip.
3. Activate the Left dispense until water flow stops automatically, approximately 20 sec.
4. Repeat Steps 2 & 3 for the Right dispense tip.
The Rinse LED will turn OFF, when the Rinse procedure has been satisfied for both sides.
5. Open the cabinet door and select Normal on the Function Selector switch – close the door.
1 5
BIB Empty Lockout Feature
The dispenser can be set to not dispense product when the concentrate BIB is empty. To enable this feature, first calibrate the Empty BIB Threshold (refer to Field Calibrating the Empty BIB Warning) . Then enable the BIB Empty
Lockout feature (refer to the BIB Empty Lockout menu in Programming the Dispenser) . The dispenser will now
Lockout dispensing and flash the Right or Left “REFILL LED” corresponding to the empty BIB. Once the BIB has been replaced, PRIME the concentrate line (refer to Priming the Concentrate Lines) and then dispense mixed product until the “REFILL LED” goes out. NOTE: If the dispenser fails to clear the BIB Empty Lockout, repeat the
Priming operation a second time to insure the concentrate is flowing properly.
Brew Temperature Lockout Feature
The dispenser can be set to not dispense product if the hot water is not up to the preset READY temperature. To enable this feature set the READY temperature to the minimum allowable dispense temperature. Then enable the
Brew Lockout feature, refer to READY TEMP and BREW LOCKOUT, in Programming the Dispenser.
12 36026 042104
PROGRAMMING THE DISPENSER
Remove the lower splash guard assembly to access the digital programming module with LCD display.
Press the Down Arrow key to inter the programming menu.
Use the Up and Down Arrow keys to scroll through the menu screens.
Select Exit to leave the programming function and return to normal operations.
NOTE 1: Flashing menu items indicate which selection is active.
NOTE 2: Values shown below are the factory default values for English units.
NOTE 3: Values in [X - X] are the Min. and Max. for that function.
MENU SCREEN ACTION DESCRIPTION
TANK TEMP XXX
CABINET TEMP XX
L DISPENSE RATIO
(-) 35:1 (+)
SET LF TUBE SIZE
1/8 EXIT 3/16
Use the Down Arrow Key to enter Programming
Functions
Use the (+) or (-) buttons to adjust the Mix Ratio
Select tube size.
Normal Display for LCR models.
Enter the desired Mix Ratio for the concentrate used in the Left dispenser. [20:1 - 100:1]
Enter Pump Tube Size to be used in the Left metering pump, (see Tube Selection Chart )
R DISPENSE RATIO
(-) 35:1 (+)
SET RT TUBE SIZE
1/8 EXIT 3/16
Use the (+) or (-) buttons to adjust the Mix Ratio
Enter the desired Mix Ratio for the concentrate used in the Right dispenser. [20:1 - 100:1]
Select tube size.
Enter Pump Tube Size to be used in the Right metering pump, (see Tube Selection Chart )
FLAVOR GUARD ?
NO EXIT YES
Select (YES) to activate.
Select (NO) to deactivate.
Select Yes, if you are ready to calibrate the Flavor
Guard sensor. Select NO, if you do not wish to use this feature, (see Flavor Guard )
If NO - go to LF DISP VOLUME menu.
LF TASTE OK ?
NO EXIT YES
Select (YES) or (NO) Select YES, if you have dispensed several cups and are satisfied with the Left dispenser flavor.
Select NO, if you have not run taste test.
FIND LF TARGET
PULL DISPENSE
Place a 16 Oz. (500 mL) cup under the Left dispense tip, then activate the Left dispenser
Calibrates the Left FlavorGard™ sensor to the current MixProfile. The dispenser will shut OFF automatically when finished.
RT TASTE OK ?
NO EXIT YES
Select (YES) or (NO) Select YES, if you have dispensed several cups and are satisfied with the Right dispenser flavor.
Select NO, if you have not run taste test.
FIND RT TARGET
PULL DISPENSE
Place a 16 Oz. (500 mL) cup under the Right dispense tip, then activate the Right dispenser
Calibrates the Right FlavorGard™ sensor to the current MixProfile. The dispenser will shut OFF automatically when finished.
13 36026 042104
MENU SCREEN
LOCK FLAVOR ?
EXIT YES
ACTION
Select (YES) or (EXIT)
DESCRIPTION
Select YES, to Lock In sensor calibration. NOTE:
Display will return to “Find LF Target” if sensor calibration is out of range.
FLAVORS LOCKED
EXIT
NONE Confirms that sensor calibration was in range and accepted. Scroll down to continue.
Portion Control Settings for Pull & Hold Dispensers
For Portion Control Dispensers (LCR-2 PC, LCR-2C PC, and LCR-2A PC) go to Full Time Portion Control Settings
LF DISP VOLUME
(-) 4.0oz (+)
Use the (+) or (-) buttons to adjust the volume
Set the volume to be dispensed during a Left
Portion controlled dispense to:
[0 - 640 Oz.] or [0 - 18.93L]
RT DISP VOLUME
(-) 4.0oz (+)
Use the (+) or (-) buttons to adjust the volume
Set the volume to be dispensed during a Right
Portion controlled dispense to:
[0 - 640 Oz.] or [0 - 18.93L]
Full Time Portion Control Settings
LF DISP VOLUME 1
(-) 4.0oz (+)
Use the (+) or (-) buttons to adjust the Normal Left volume
Set the desired portion control volume to be dispensed during a Normal Left dispense to:
[0 - 640 Oz.] or [0 - 18.93L]
LF DISP VOLUME 2
(-) 0.0oz (+)
RT DISP VOLUME 1
(-) 4.0oz (+)
RT DISP VOLUME 2
(-) 0.0oz (+)
WATER DISP VOL 1
(-) 0.0oz (+)
WATER DISP VOL 2
(-) 0.0oz (+)
Use the (+) or (-) buttons to adjust the Alternate Left volume
Set the desired portion control volume to be dispensed during a Alternate Left dispense to:
[0 - 640 Oz.] or [0 - 18.93L]
Use the (+) or (-) buttons to adjust the Normal Right volume
Set the desired portion control volume to be dispensed during a Normal Right dispense to:
[0 - 640 Oz.] or [0 - 18.93L]
Use the (+) or (-) buttons to adjust the Alternate Right volume
Set the desired portion control volume to be dispensed during a Alternate Right dispense to:
[0 - 640 Oz.] or [0 - 18.93L]
Use the (+) or (-) buttons to adjust the Normal Hot Water volume
Set the desired portion control volume to be dispensed during a Normal Hot Water dispense:
[0 - 640 Oz.] or [0 - 18.93L]
Use the (+) or (-) buttons to adjust the Alternate Hot Water volume
Set the desired portion control volume to be dispensed during a Alternate Hot Water dispense:
[0 - 640 Oz.] or [0 - 18.93L]
14 36026 120105
MENU SCREEN
TANK TEMP 180
(-) EXIT (+)
READY TEMP 175
(-) EXIT (+)
CABINET TEMP 38
(-) EXIT (+)
LF PRODUCT DISP
.0GAL RESET?
LF PRODUCT DISP
.0GAL
RT PRODUCT DISP
.0GAL RESET?
RT PRODUCT DISP
.0GAL
ACTION DESCRIPTION
Use the (+) or (-) buttons to adjust the target Temp.
Sets the water Tank temperature [120 - 200°F] or [49 - 93°C]
Use the (+) or (-) buttons to adjust the target Temp.
Sets the hot water Ready temperature. Typically set to the minimum desired dispense temp.
Use the (+) or (-) buttons to adjust the target Temp.
Sets the Chilled Cabinet target temperature [38
- 50°F] or [3 - 10°C]
Select (RESET) to clear total Selecting Reset will clear the Current accumulated volume of concentrate dispensed through the Left dispenser. Gal (Liters)
NONE Displays the Total accumulated volume of concentrate dispensed through the Left dispenser.
Not Re-settable. Gal (Liters)
Select (RESET) to clear total Selecting Reset will clear the Current accumulated volume of concentrate dispensed through the
Right dispenser. Gal (Liters)
NONE Displays the Total accumulated volume of concentrate dispensed through the Right dispenser. Not Re-Settable. Gal (Liters)
The following functions can be Password Protected. If you wish to prevent others from accessing these functions, enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these functions in the future.
ENTER PASSWORD
(-) 0 (+)
Use the (+) or (-) buttons to enter password.
Enter the access Code to view the remaining functions. Factory Default = 0.
SET PASSWORD ?
(-) 0 (+)
SELECT UNITS
ENG EXIT METRIC
CHILLED UNIT ?
NO EXIT YES
RINSE ALARM ?
NO EXIT YES
Use the (+) or (-) buttons to change the password.
Enter your own Code to prevent access to the remaining functions. [0 to 9999]
Select the preferred units
Select (YES) or (NO)
Select (YES) or (NO)
Used to select the preferred units of measurement.
(Oz., Gal, deg F) or (mL, L, deg C)
LCR Models default to (YES)
Select (NO) to turn the refrigeration system
OFF.
Selecting Yes will enable the Rinse Alarm function,
(see Rinse Alarm )
If NO - go to BIB EMPTY LOCKOUT menu.
15 36026 120105
MENU SCREEN
RINSE TIME ?
(-) 12 Hrs (+)
ACTION
Use the (+) or (-) buttons to adjust Rinse Alarm delay
DESCRIPTION
Enter the desired time between required Rinse
Cycles in hours, [8 - 24 hrs.]
RINSE LOCKOUT ?
NO EXIT YES
Select (YES) to enable Select YES to Lockout dispensing until the Rinse
Alarm has been cleared. Default is NO
BIB EMPTY LOCKOUT
NO EXIT YES
BREW LOCKOUT ?
NO EXIT YES
DLY REPEAT DISP
(-) 0 SEC (+)
Select (YES) to enable Select YES to Lockout dispensing until the
Concentrate BIB has been replaced. Default is
NO
Select (YES) to enable
Use the (+) or (-) buttons to adjust the Delay Time
Select YES to Lockout dispensing until the hot water tank is at READY Temp. Default is NO
Enter the desired time delay before allowing the next dispense to take place, [0 - 10 sec.]
The following functions are for diagnostic and troubleshooting purposes and typically do not have to be adjusted. Contact your local service agent for assistance before making changes to these functions.
CAL LEFT SIDE ?
EXIT YES
Select (YES) to enable Selecting Yes will enable the Left Dispenser
Calibration routine, (see Field Calibration before attempting to calibrate the dispenser).
If NO - go to CAL RIGHT SIDE menu.
CAL LEFT PUMP ?
PULL DISPENSE
CAL LF PUMP VOL
(-) 43mL (+)
CAL LF WTR FLOW ?
PULL DISPENSER
CAL LF WTR VOL
(-) 36.0OZ (+)
CAL LEFT SIDE ?
EXIT YES
CAL RIGHT SIDE ?
EXIT YES
Place a 50 mL (#34843.1000) graduated cylinder under the
Left dispense tip, then activate the Left Dispenser
The Left Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.
Use the (+) or (-) buttons to enter volume collected
Enter the volume of concentrate measured from the Left Pump in mL, (not Oz.) regardless of
Preferred Units selected.
Place a 64 Oz. (2000 mL) container under the Left dispense tip, then activate the
Left Dispenser
The Left Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.
Use the (+) or (-) buttons to enter volume collected
Enter the volume of the water measured from the
Left dispenser in Oz. (mL).
NONE Scroll down to bypass this screen.
Select (YES) to enable
Calibration routine.
16
Selecting Yes will enable the Right Dispenser
Calibration routine, (see Pump Calibration ) prior to calibrating the dispenser.
36026 120105
MENU SCREEN
If NO - skip to next menu.
CAL RIGHT PUMP ?
PULL DISPENSER
ACTION DESCRIPTION
Place a 50 mL (#34843.1000) graduated cylinder under the Right dispense tip, then activate the Right Dispenser
The Right Pump will dispense concentrate for
20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.
CAL RT PUMP VOL
(-) 43mL (+)
CAL RT WTR FLOW
PULL DISPENSER
Use the (+) or (-) buttons to enter volume collected
Enter the volume of concentrate measured from the Right Pump in mL(not Oz.) regardless of
Preferred Units selected.
Place a 64 Oz. (2000 mL) container under the Right dispense tip, then activate the
Right Dispenser
The Right Dispenser will dispense hot water for
20 seconds, then shut off automatically. Collect and measure the water dispensed.
Use the (+) or (-) buttons to enter volume collected
Enter the volume of the water measured from the
Right dispenser in Oz. (mL)
CAL RT WTR VOL
(-) 36.0OZ (+)
CAL RIGHT SIDE ?
EXIT YES
NONE Scroll down to bypass this screen.
For Portion Control Dispensers (LCR-2 PC, LCR-2C PC, LCR-2A PC) only
CAL HOT WTR FLO ?
PULL DISPENSE
Place a 64 Oz. (2000 mL) container under the Hot Water dispense tip, then activate the
Hot Water Dispenser
The Hot Water Dispenser will dispense for 20 seconds, then shut off automatically. Collect and measure the water dispensed.
CAL HOT WTR VOL
(-) 34.0OZ (+)
Use the (+) or (-) buttons to enter volume collected
Enter the volume of the water measured from the
Hot Water Dispenser in Oz. (mL)
XXX CAL -> XXX
(-) TankTemp (+)
FlvrGrdRange 10%
(-) EXIT (+)
LfFlvrGrdTargets
RPM XXX-CON XXX
RtFlvrGrdTargets
RPM XXX-CON XXX
Use the (+) or (-) buttons to adjust temperature reading
Adjust the display reading to match a calibrated probe inserted next to the Tank Sensor, °F (°C).
Use the (+) or (-) buttons to adjust % value
Used to set the maximum adjustment the Flavor
Guard feature is allowed to make, [3 - 15%].
NONE
NONE
Displays the Left Dispenser target RPM and
Conductance Reading, (Diagnostics Only)
Displays the Right Dispenser target RPM and
Conductance Reading, (Diagnostics Only)
17 36026 120105
MENU SCREEN
BIB EMPTY -> 500
(-) EXIT (+)
XX REFILL -> 155
(-) EXIT (+)
WTR START DELAY
(-) .15SEC (+)
WTR STOP DELAY
(-) .15SEC (+)
TEST LED’S ?
NO EXIT YES
TEST SWITCHES ?
UseSwitchToTest
TEST REFILL ?
EXIT YES
TEST HEATER ?
EXIT YES
ENTER ASSET #
(-) 000000 (+)
SERIAL #
LCR 0000000
FACTORY DEFAULTS
NO YES
ACTION DESCRIPTION
Use the (+) or (-) buttons to adjust empty BIB threshold
Used to set the Conductance Threshold for the
Empty BIB warning. Default is 500
Use the (+) or (-) buttons to adjust Refill threshold
Used to set the Conductance Threshold for the
Tank Refill Probe.
Use the (+) or (-) buttons to adjust delay time
Dispense Valve ON Delay. Eliminates weak mix at the beginning of a dispense.
Use the (+) or (-) buttons to adjust delay time
Dispense Valve OFF Delay. Flushes the mix chamber at the end of a dispense.
Select (YES) or (NO)
NONE
LED diagnostics. Selecting YES will light all Front
Door LED’s.
Switch Diagnostic: Activate switches separately to test. Display will indicate which Switch has been activated. NOTE: Door Interlock switch must be held closed.
Momentarily depress (YES) Refill Valve Diagnostic: Press YES to momentarily energize the Solenoid. CAUTION: Inlet Valve will open and water will flow, if connected and turned
ON.
Momentarily depress (YES) Tank Heater Diagnostic: Press YES to momentarily energize the Tank Heater Circuit.
CAUTION: AC power will be applied to the Tank
Heater Circuit.
Use the (+) or (-) buttons to adjust the ASSET NUMBER
Allows the user the option of entering an Asset
Number. Default is 000000
NONE
Select (YES) or (NO)
Displays the manufacture’s Serial Number (should be identical to the Serial Number on the machine
Data Plate)
CAUTION: Selecting YES will RESET all
Programming Functions to the Factory Default settings. NOTE: On LCC Models the Chiller will have to be reset to the ON condition, (see Chilled
Unit programming function).
18 36026 061605
LOADING THE CONCENTRATE
1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB).
2. Pull the BIB connector through the hole provided in the box and place it on the drip tray with the connector facing up. (See Fig. 1)
3. Open the dispenser door and locate the appropriate left or right BIB Adapter fitting.
4. Pull the Adapter fitting down and connect it to the BIB. (See Fig. 2)
5. Place the BIB upright in the machine, rotating it into position with the connector facing forward.
6. Rotate the BIB Adapter to avoid sharp bends in the tubing and allow it to be routed between the two pumps.
Refer to the Tube Installation Decal on the door for proper routing. (See Fig. 3)
7. Close the cabinet door.
Fig. 1 Fig. 2 Fig. 3
PRIMING THE CONCENTRATE LINES
1. Open the dispenser door.
2. Load concentrate per instructions in the section titled Loading the Concentrate .
3. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch.
4. Close the dispenser door.
5. Place a container under the appropriate dispense tip.
6. Activate the appropriate dispenser until concentrate flows from the dispense nozzle. Priming may take 5 to
10 seconds.
7. Open the dispenser door, select Normal on the Function Selector Switch, and then close door.
Note: Concentrate may continue to drip out of dispense tip. The user may wish to run a Rinse Cycle (refer to
Rinsing ) after Priming the dispenser to clean out the remaining concentrate.
7 3 3
19 36026 042104
OPERATING THE PULL & HOLD DISPENSER
(Models LCR-2, LCR-2C, LCR-2A)
Set the Function Selector Switch to Normal and the Mode Selector Switch to Run.
1. Pull and Hold Dispense Mode (Cup at a time) a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.
b. Pull and Hold the corresponding dispense handle until the cup or other container is full.
c. Remove cup or container.
2. Portion Dispense Mode (Preset volume dispensing) Refer to Programming Functions on how to set this volume.
a. Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup tray up and place the container on top of the drip tray.
b. Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion
Switch is pressed.
c. Momentarily pull the corresponding dispense handle, then release. If the user waits longer than 5 seconds to pull the handle, the dispenser will default back to the Pull & Hold Mode. Portion Dispense Mode can be disabled at any time during the portion dispense by either momentarily pulling the Dispense Handle again or pressing the Stop button.
d. Wait for container to fill and the dispenser to quit dispensing, then remove container.
3. Hot Water Dispense a. Place container under the hot water dispenser (center of machine). For large containers, flip the cup tray up and place the container on top of the drip tray.
b. Push and hold the Hot Water Switch until the water reaches the desired level, then release.
c. Remove container.
Filling Cambros or other large containers:
The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips.
However, it may be used to fill larger containers (up to 2 Gal) by use of an extension hose on the dispense tip.
Removing the Flow Restrictors will increase the dispenser flow rate to 2.5 Oz/sec. (74 mL/sec.) and reduce the time to fill larger containers, (see Setting Dispenser Flow Rate .)
Care must be taken to insure that the mixed product flows freely from the dispense tip into the container.
1. Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose.
2. Use as short a hose as possible with no loops, bends or kinks in it.
3. Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container
A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube.
NOTE: The temperature of the product being dispensed will start to drop after ~2 gal. continuous draw. Recovery time will be dependent on the temperature of the supply water and the voltage at which the heater coil is being operated.
20 36026 042104
OPERATING THE PRESET PORTION CONTROL DISPENSER
(Models LCR-2 PC, LCR-2C PC, LCR-2A PC)
Set the Function Selector Switch to Normal and the Mode Selector Switch to Run.
Dispensing Preset Portions of Coffee or Hot Water
1. Primary Volume Portion Dispense Mode. (Volume 1) Refer to Programming Functions on how to set this amount.
a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.
b. Momentarily press the appropriate dispense switch. The dispenser will automatically dispense the beverage at the preset amount. Allow the mix chamber to drain at the end of the cycle.
c. Remove cup or container.
2. Alternate Volume Portion Dispense Mode. (Volume 2) Refer to Programming Functions on how to set this volume.
a. Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup tray up and place the container on top of the drip tray.
b. Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion
Switch is pressed.
c. Momentarily press the corresponding Dispense Switch. If the user waits longer than 5 seconds to push the switch, the dispenser will default back to the Primary Volume preset amount. Alternate Portion
Dispense Mode can be disabled at any time during the portion dispense by either momentarily pushing the Dispense Switch again or pressing the Stop button.
d. Wait for the container to fill and the dispenser to quit dispensing, then remove the container.
Push and Hold Dispensing of Coffee or Hot Water
Push and Hold Dispense Mode. See Programming Functions on how to set the Preset Volume to Zero.
a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.
b. Push and hold the corresponding dispense switch until the container is full.
c. Remove cup or container.
Filling Cambros or other large containers:
The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips.
However, it may be used to fill larger containers (up to 5 Gal) by use of an extension hose on the dispense tip.
Removing the Flow Restrictors will increase the dispenser flow rate to 2.5 Oz/sec. (74 mL/sec.) and reduce the time to fill larger containers, (see Setting Dispenser Flow Rate .)
Care must be taken to insure that the mixed product flows freely from the dispense tip into the container.
1. Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose.
2. Use as short a hose as possible with no loops, bends or kinks in it.
3. Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container
A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube.
NOTE: The temperature of the product being dispensed will start to drop after ~2 gal. continuous draw. Recovery time will be dependent on the temperature of the supply water and the voltage at which the heater coil is being operated.
21 36026 120105
CLEANING & PREVENTATIVE MAINTENANCE
General Cleaning and Sanitizing Procedures
Note: The BUNN ® Liquid Coffee Dispenser incorporates a “user selectable” rinse reminder feature, which lights the Rinse LED on the front panel and disables dispensing when it is time to rinse. See Programming Functions to activate this feature.
Daily: RINSING
1. Open the dispenser door.
2. Select Rinse on the Function Selector Switch and Run on the Mode Selector Switch.
3. Close the dispenser door.
4. Place a 1/2 gal (2 liter) container under the appropriate dispense nozzle or nozzles.
5. Activate the dispenser on the appropriate side or sides for approximately twenty seconds or until the hot water is clear or has no concentrate coloring in it.
6. Open the dispenser door, select Normal on the Function Selector Switch, and then close door.
Note: To clear the “Rinse” alarm, activate the dispenser until the flow stops automatically (approx. 20 seconds for each tip). The “Rinse” alarm LED will turn off when the Rinse Procedure has been satisfied for both sides.
Daily: PARTS WASHING
1. Remove and wash the drip tray, drip tray cover, and cup tray in a mild detergent solution. Rinse thoroughly.
2. Wipe splash panel, area around dispense nozzles, door, and cabinet with a clean damp cloth.
Weekly: SANITIZING
1. Open the dispenser door.
2. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch.
3. Remove the bag connector from the product box and disassemble or prop open the internal valve to allow free flow of product through the connector. NOTE: Cutting the mating fittings from an empty bag makes an excellent “free flowing” connector for this purpose.
4. Place the bag connector into a one-gallon (3.8 liter) container of warm soapy tap water 140°F (60°C).
5. Place an empty container under dispense tip and activate the corresponding dispenser until the clean soapy water is dispensed from the dispense tip.
6. Repeat steps 4 and 5 with warm tap water 140°F (60°C) to rinse the soapy water from the pump tubing.
Continue dispensing until the water is clear, and no soapy water is being dispensed.
7. Prepare 2.5 gallons (9.46L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gallons
(9.46L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine.
8. Again, repeat steps 4 and 5 with the sanitizing solution. Once sanitizing solution is being dispensed, stop dispensing and allow the solution to sit for 5 minutes.
9. Repeat step 6 to flush out the sanitizing solution from the pump tubing.
10. Remove the mating connector from the bag connector.
11. Reattach the bag connector to product box.
12. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.
13. Activate the dispenser until concentrate/water mixture appears. Then dispense one 12 ounce (354.9 ml) glass of concentrate/water mixture and discard.
14. Repeat steps 1 through 13 for other dispense head.
15. Wipe internal and external surfaces with a clean, damp cloth.
Weekly: REFRIGERATION AIR FILTER
1. Remove the screen filter from the back of the dispenser.
2. Wash the screen in a mild detergent solution.
3. Use a soft bristled brush to remove all dust and grease.
4. Reinstall the screen on the back of the dispenser.
22 36026 042104
REPLACING THE PUMP TUBING
The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed beverage. Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or sooner if warranted.
Refer to the Tube Replacement Instruction on the Cabinet door for details.
1. Rinse the pump tubing with warm tap water (Refer to steps 1 - 5 of the Weekly Sanitizing instructions ) prior to removing the tubes to avoid concentrate spills.
2. Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set it and the retainer plate aside.
3. Depress the tension screw and remove it from the notch in the pump housing, releasing the spring tension on the pump band.
4. Open the compression band and gently pull the pump tube from around the pump’s rotor.
5. Inspect the pump bands for signs of wear. Replace if necessary.
6. Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing’s rotor side.
7. Insert the tube onto the mix chamber port, then wrap the new tubing around the pump rotor, making sure that the elbow and clamps end up on the bottom side of the pump housing.
8. Depress the tension screw and insert it in the notch in the pump body, reapplying spring tension on the pump band.
9. Replace the tubing retainer plate and tighten the thumbscrew.
10. Repeat steps 1 through 9 for the other pump.
Thumbscrew
Tension
Screw
Remove Retaining Plate Release Spring Tension Remove Tubing
2.0”
2.0”
Lubricate between arrows
Lubricate New Tube
Tension Screw
Tube Clamp
Install New Tubing Completed Installation
23 36026 101703
DRAINING THE HOT WATER TANK
CAUTION: The dispenser must be disconnected from the power source throughout these steps.
1. Disconnect the dispenser from the power source.
2. Shut off and disconnect the incoming water supply.
3. Remove the front splash panel.
4. Pull out drain tube to empty into a sink or a container with a minimum of five-gallon capacity.
5. Make sure drain clamp is closed. Then, remove drain plug.
6. Direct tube into sink or container and open drain clamp. Continue draining tank until ALL of the water is out.
Be very careful with the draining water because it can be very hot.
7. Close drain clamp, insert drain plug, place drain tube back into machine, and replace splash panel.
Note: The dispenser must be refilled using the Initial Fill & Heat steps before reconnecting the power source.
24 36026 101703
Troubleshooting
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
• Only qualified service personnel should perform inspection, testing, and repair of electrical equipment.
• Shorting the terminals or the application of external voltages to electronic components may result in component or circuit board failure.
• Intermittent operation of electronic circuit boards is unlikely. board failure will normally be permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or a loose wire connection at a terminal or crimp.
• Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water.
• The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help avoid twists and kinks in the tubing.
• Make certain that all plumbing connections are sealed and all electrical connections are tight and isolated.
• This dispenser is heated at all times. Keep away from combustibles.
WARNING:
• Exercise extreme caution when servicing electrical equipment.
• Disconnect the brewer from the power source when servicing, except when electrical tests are specified. The red “Power LED” on the door indicates that the unit is connected to AC Power.
• Follow recommended service procedures.
• Replace all protective shields or safety notices.
Front Panel LED Display Messages
Power LED “OFF”
No AC Power
Dispenser Not plugged in.
AC Circuit Breaker OFF
Ready LED “OFF”
Water Temp. Too Low
Usage has exceeded the capacity of the Tank Heater
Rinse LED “ON”
Rinse Timer
Rinse Cycle Required
Rinse LED “FLASHING”
Rinse Lockout Enabled
Dispenser Locked Out
Rinse Cycle Required
Portion LED “ON”
Portion Dispense
Enabled
Alternate Portion Dispenser
Volume #2 has been selected
Check Power Cord
Check the AC Power Circuit Breaker
Service Required
Check Tank Temp Setting
Check Ready Temp. Setting
Service Required: Change the Supply Voltage, see Optional Field Wiring
Rinse Dispenser, see Rinse Procedure
Rinse Dispenser, see Rinse Procedure
Activate the Dispenser within 5 sec. to dispense the pre-selected volume.
25 36026 042104
Troubleshooting (Continued)
Left Refill LED “ON”
Left BIB Empty
Right Refill LED “ON”
Right BIB Empty
Concentrate BIB is Empty.
BIB Not properly connected
Tubing kinked or blocked
Empty BIB warning set too high
Replace BIB, see Loading the Concentrate
Check BIB Connector Fittings
Check Tubing Installation
Check Threshold, see Field Calibrating the
Emoty BIB Warning
Concentrate BIB is Empty.
BIB Not properly connected
Tubing kinked or blocked
Empty BIB Warning set too high
Replace BIB, see Loading the Concentrate
Check BIB Connector Fittings
Check Tubing Installation
Check Threshold, see Field Calibrating the
Empty BIB Warning
Left Dispenser will not operate Replace BIB, see loading the Concentrate Left Refill LED
“FLASHING”
Empty BIB Lockout
Enabled
Right Refill LED
“FLASHING”
Empty BIB Lockout
Enabled
Right Dispenser will not operate Replace BIB, see loading the Concentrate
All LED’s “FLASHING”
Fauly Detected
The Dispenser has detected an
Internal Fault
Remove the Lower Splash Guard to view the
Fault Message, see Diagnostics. After the fault has been repaired or corrected, hold the “STOP” button for 10 seconds to clear the message.
26 36026 101703
Troubleshooting (Continued)
Dispenser Diagnostics-LCD Display
Screen Displayed Possible Cause
LF TARGET RPM
TOO HIGH !!
Troubleshooting Procedures
1. The Tube Size selected for the Left
Hand Dispenser is too small for the application.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
TUBE TOO SMALL
CHECK DISP RATIO
RT TARGET RPM
TOO HIGH !!
TUBE TOO SMALL
CHECK DISP RATIO
LF TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
RT TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
2. The Ratio selected for the Left Hand
Dispenser is not correct for the application.
Refer to recommended Dispense Ratio on the product label.
1. The Tube Size selected for the Right
Hand Dispenser is too small for the application.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
2. The Ratio selected for the Right
Hand Dispenser is not correct for the application.
Refer to recommended Dispense Ratio on the product label.
1. The Tube Size selected for the Left
Hand Dispenser is too large for the application.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
2. The Ratio selected for the Left Hand
Dispenser is not correct for the application.
Refer to recommended Dispense Ratio on the product label.
1. The Tube Size selected for the Right
Hand Dispenser is too large for the application.
Refer to “Selecting the Correct Pump
Tubing” section of the manual.
2. The Ratio selected for the Right
Hand Dispenser is not correct for the application.
Refer to recommended Dispense Ratio on the product label.
Service Required
Service Required
LEFT PUMP FAULT!
CHK PUMP WIRING
CHK RPM SENSOR
CHK TUBING AREA
RT PUMP FAULT!
CHK PUMP WIRING
CHK RPM SENSOR
CHK TUBING AREA
1. Motor failure
2. RPM Sensor failure
1. Motor failure
2. RPM Sensor failure
Service Required
Service Required
27 36026 041204
Screen Displayed
LEFT BIB EMPTY!
REPLACE PRODUCT
CHECK THRESHOLD
RIGHT BIB EMPTY!
REPLACE PRODUCT
CHECK THRESHOLD
OVERFLOW CUP
FULL. EMPTY CUP
HEATING TIME TOO
LONG
CHECK HEATING
CIRCUIT
FILL TIME TOO LONG
CHECK WATER SUPPLY
Troubleshooting (Continued)
Possible Cause
1. Concentrate BIB is Empty.
Troubleshooting Procedures
Replace BIB, see loading the
Concentrate
2. BIB Not properly connected.
3. Tubing kinked or blocked.
4. Empty BIB Warning set too high.
1. Concentrate BIB is Empty.
2. BIB Not properly connected.
3. Tubing kinked or blocked.
4. Empty BIB Warning set too high.
Check BIB Connector Fittings
Check Tubing installation
Check Threshold, see Field Calibrating the Empty BIB Warning
Replace BIB, see loading the
Concentrate
Check BIB Connector Fittings
Check Tubing installation
Check Threshold, see Field Calibrating the Empty BIB Warning
1. Refill valve stuck open Service Required
2. Faulty refill probe Service Required
3. Faulty overflow switch Service Required
1. Tank Heater failure Service Required
2. Triac failure Service Required
3. Tank Temp. sensor failure
1. Water shut off to dispenser
Service Required
Check water supply shut-off
2. Inlet Solenoid Valve failure Service Required
1. Corresponding Temperature Sensor
Probe wire(s) broken or disconnected
Service Required TANK TEMP SENSOR
OUT OF RANGE
CHECK FOR BAD
CONNECTIONS
TANK TEMP SENSOR
OUT OF RANGE
CHECK WIRE FOR
SHORTS
1. Corresponding Temperature Sensor
Probe wire(s) shorted to housing, or to each other.
Service Required
28 36026 041204
Screen Displayed
COOL TEMP SENSOR
OUT OF RANGE
CHECK FOR BAD
CONNECTIONS
COOL TEMP SENSOR
OUT OF RANGE
CHECK WIRE FOR
SHORTS
EVAP TEMP SENSOR
OUT OF RANGE
CHECK FOR BAD
CONNECTIONS
EVAP TEMP SENSOR
OUT OF RANGE
CHECK WIRE FOR
SHORTS
COOLER FAULT!
EVAP TEMP TOO HI
CHECK EVAP FAN
CHK EVAP SENSOR
COOLING TIME
TOO LONG
CHECK AIR FILTER
CHECK COOLING UNIT
COND PROBE FAULT
CHECK COND PROBES
CHK DISP SWITCHES
CHK CONNECTIONS
JUMPER FAULT!
CONFIG NOT VALID
CHECK J-18
ON CONTROL BOARD
Troubleshooting (Continued)
Possible Cause
1. C o r r e s p o n d i n g Te m p e r a t u r e
Sensor Probe wire(s) broken or disconnected.
2. Product cabinet temperature too low.
1. Corresponding Temperature Sensor
Probe wire(s) shorted to housing, or to each other.
2. Product cabinet temperature too high.
1. Corresponding Temperature Sensor
Probe wire(s) broken or disconnected.
2. Evaporator temperature too low.
1. Corresponding Temperature Sensor
Probe wire(s) shorted to housing, or to each other.
2. Evaporator temperature too high.
1. Cabinet circulating fan failure
2. Ice build up on evaporator coils
3. Evaporator sensor failure
1. Air intake filter clogged
2. Wiring failure
3. Compressor failure
1. Tube leaking
2. Dispense switch failure
3. Dispense valve leaking
1. Invalid wire harness configuation
29
Troubleshooting Procedures
Service Required
Service Required
Service Required
Service Required
Service Required
Service Required
Service Required
Service Required
Service Required
Service Required
Service Required
Clean Air Filter
Check wiring harness for breaks, shorts, open connectors
Service Required
Check pump & tubing for proper installation
Service Required
Service Required
Service Required
36026 121506
Field Calibration of the Concentrate Pumps / Dispenser Flow Rates
The factory set Default Values for the Pump & Dispenser Flow Rates are very accurate and typically do not need to be field calibrated. However, if the mix ratio accuracy is ever in question, this procedure can be used to recalibrate the unit in the field.
Equipment Required:
50 to 100 ml graduated cylinder, with 1 ml graduations.
64 Oz (2000 ml) graduated container.
Remove the lower splash guard assembly to access prior to starting this procedure
NOTE: You can calibrate either the Concentrate Pump or the Dispenser Flow Rate independently. Simply scroll through the menu screen to the desired section and perform only those steps.
Calibrating the Left Side Dispenser
Concentrate Pump Calibration
1. Select PRIME on the Function Selector Switch. (refer to Priming the Concentrate Lines ).
2. Place a container under the Left Dispense Tip and prime the concentrate lines until a steady stream of concentrate comes out the tip (approximately 10 seconds).
3. Stop the Priming and allow the tip to stop dripping. Discard the concentrate collected.
4. Select NORMAL on the Function Selector Switch.
5. Locate the programming module and use the Arrow Down key to scroll through LCD screens until CAL
LEFT SIDE appears and press the YES button.
6. The CAL LEFT PUMP menu screen will be displayed. Place a 50 ml graduated cylinder under Left Dispense
Tip and activate the Left dispenser momentarily. The dispenser will run the Left Concentrate Pump for 20 seconds and then shut OFF automatically.
7. Keep the graduated cylinder under dispense tip until all the concentrate has dripped out.
8. Measure the volume of concentrate collected in the graduated cylinder.
Acceptable ranges for the volume collected
Tubing Size
3/16” tubing
1/8” tubing
Volume Collected
40 - 47 ml.
17 - 22 ml
9. If the amount collected is not within the acceptable range, empty the graduated cylinder and repeat STEPS
6 – 8.
10. If the amount collected is still not within range, replace the pump tubing with a new Tube Kit, (refer to the Tube Replacement Instructions ).
11. When satisfied with the volume of concentrate collected, press the Down Arrow Key
12. The CAL LF PUMP VOL menu screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 8.
(Continued Next Page)
30 36026 042104
Field Calibration of the Concentrate Pumps / Dispenser Flow Rates
(Continued)
Dispenser Flow Rate Calibration
13. Press Down Arrow Key to display the CAL LF WTR FLO menu screen.
14. Place a 64 Oz (2000 ml) graduated container under Left Dispense Tip and Pull the Left Dispense Handle momentarily. The dispenser will dispense water for 20 seconds and then shut OFF automatically.
15. Keep the graduated container under dispense tip until all the water stops dripping.
16. Measure the volume of water collected in the graduated container.
Acceptable ranges for the volume collected
_____Dispenser Flow Rate___________
1.8 Oz/sec (53 ml/sec) w/ flow restrictor
2.5 Oz/sec (74 ml/sec) w/o flow restrictor
____Volume Collected____
32 - 38 Oz, (946 - 1124 ml)
46 - 52 Oz ,(1360 - 1538 ml)
17. If the amount collected is not within the acceptable range, empty the graduated container and repeat
STEPS 14 – 16
18. If the amount collected is still not within range, inspect the dispense valves, tubing and mix chamber for lime, kinks or other obstructions.
19. When satisfied with the volume of concentrate collected, press the Down Arrow Key.
20. The CAL LF WTR VOL screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 16.
21. Press Down Arrow Key again to exit the CAL LEFT SIDE functions.
Calibrating the Right Side Dispenser
Repeat STEPS 1-21 above for the “CAL RIGHT SIDE” menus.
Field Calibrating the Hot Water Flow Rate
1. Locate the programming module and use the Arrow Down key to scroll through the LCD screen until “CAL
HOT WTR FLO?” appears.
2. Place a 64 Oz (2000 ml) graduated container under Hot Water Tip and press the hot water switch. The unit will dispense Hot Water for 20 seconds and then shut OFF automatically. Keep the graduated container under the dispense tip until all the water stops dripping.
3. Measure the volume of water collected in the graduated container. The acceptable range for the volume collected is 32 - 38 Oz. (946 - 1124 ml).
4. If the amount collected is not within the acceptable range, empty the container and repeat steps 2 & 3.
5. If the amount collected is still not within range, inspect the hot water valve, tubing and fittings for lime, kinks, or other obstructions.
6. When satisfied with the volume of concentrate collected, press the Down Arrow Key.
7. The “CAL HOT WTR VOL” screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the ammount measured in step 3.
8. Press Down Arrow Key again to exit this function.
31 36026 120105
Field Calibrating the Empty BIB Warning
The dispenser will automatically turn on the Left or Right “REFILL LED”, see Operating Controls and Interface , when the corresponding BIB is Empty. The Refill message is triggered when the FlavorGard TM sensor reading drops below the minimum setting. The factory set minimum is 500 and should be correct for most locations.
However, in some areas the hardness of the local water supply may effect this reading. If the Refill message doesn’t come on when the BIB is empty or the message comes on too early and there is still concentrate left in the BIB, use the following procedure to find the correct Empty BIB threshold.
Calibrating The Empty BIB Threshold
1. Remove the lower splash guard assembly to access the digital programming module with LCD display.
2. Open the cabinet door and set the Function Switch to the “Rinse” position. Close the door.
3. Place a large container under the Left dispenser tip, then activate and hold the left dispenser.
4. Dispense long enough to rinse all the concentrate out of the mix chamber and for the Conductance reading to stabilize and stop dropping.
5. Record the nominal Conductance value displayed. (NOTE: It is typical for this value fluctuate (+/- 25) points about the nominal value}. This is the conductance reading of the water in your area.
6. Repeat steps 3, 4 & 5 for the Right dispenser.
7. Add 100 points to the larger of the Left or Right side Conductance value. This is the new Empty BIB threshold value for your dispenser.
8. Enter this new value into the Empty BIB Alarm threshold, see Programming the Dispenser .
32 36026 120105
SCHEMATIC WIRING DIAGRAM LCR-2/LCR-2, PC/LCR-2C/LCR-2C, PC
GRN L2 (120/208-240V 3-Wire)
N (120V 2-Wire)
N (120/208-240V 3-Wire)
L2 (208-240V 2-Wire)
TUBE
WARMER
TUBE
WARMER
TOUCHPAD
YES (+)
EXIT
NO (-)
BLK LEFT
PUMP
RED
BLK RIGHT
PUMP
RED
6
7
4
5
1
2
3
BLK-14
BLK
RED
BLK
BLK
RED
-V
+V
UNIVERSAL
POWER SUPPLY
N(L2)
L(L1)
-V
+V
WHI
BLK
GRN
GRN
RED
BLK-14
TRIAC
BLU-14
SW. & THERMOSTAT
BLU-14
TANK HEATER
BLK-14
RED-14
1
LIMIT
THERMOSTAT
2
3 4
PORTION
CONTROL
DOOR
LEFT RPM
SENSOR
RIGHT RPM
SENSOR
RED
BLK
GRN
RED
BLK
GRN
RED
BLK
BLU
RED
BLK
VIO
WHI/YEL
YEL
ORN
WHI/ORN
J14-1
J14-7
VIO
BLU
RED
YEL
ORN
BLK
BLK
RED
WHI/ORN
WHI/YEL
J7-1
J7-5
J7-10
GRN
J8-1
J8-3
J18-1
O
A
C
B
R
D
L
P
R
O
N
T
C
O
J3-1
WHI/BLU
RED
WHI/RED
J3-6
BLK
J4-5
J5-1
J5-3
J16-1
J4-1
RED
RED/BLK
BRN/WHI
BRN/BLK
WHI/GRY
BLU/BLK
J16-5
BLK
BLK
BLK
BLK
GRN
BLU
ORN
WHI/ORN
WHI/YEL
PNK
J16-12
RED-14
RED-14
WHI
OVERFLOW
PROTECTION SW
RED RED
WHI/GRY
SOL
RED
RED
HOT WATER
SOL
RED/BLK
BRN/BLK
RIGHT DISP
RED
SOL
LEFT DISP
BRN/WHI
RED
SOL
BLU/BLK
REFILL
WHI/GRY
WHI/YEL
JUMPER
WHI/YEL
WHI/YEL
DISPENSERS WITH PORTION CONTROL
GRN
J18-6
J18-7
J17-4
BLK
YEL
J17-1
WHI/YEL
BLK
BLU
BLK
YEL
1
4
BLK
BLU
BLK
YEL
LEFT
CONDUCTANCE
SENSOR
BLK WHI/ORN BLK
RIGHT
CONDUCTANCE
SENSOR
GRN
LF DISP. SW.
RT DISP. SW.
O
A
R
D
L
E
D
B
C
H
A
N
D
S
W
T
I
J1-1
J1-5
J1-10
J1-16
BLU/WHI
RED/BLK
GRN
ORN/BLK
GRN/WHI
BLK
RED/WHI
BLU/BLK
RED
GRN/BLK
WHI/BLK
ORN
WHI
BLK
SELECTOR
SWITCH
NITE
WHI/GRY
RUN
WHI/VIO
BLK
SELECTOR
SWITCH
RINSE
WHI/YEL
PRIME
TAN
BLK
WHI/BLU
RED
WHI/RED
1
WHI/BLU
RED
WHI/RED
BLK
6
BLK
C
P
F
D
T
-
+
+
120 VOLTS AC 2 WIRE
120/208-240 VOLTS AC 3 WIRE
208-240 VOLTS AC 2 WIRE
SINGLE PHASE 50/60HZ
36025.0000G 09/06 © 2003 BUNN-O-MATIC CORPORATION
Models without Master ON/OFF Switch
1 2 t
CABINET
THERMISTOR
COMPRESSOR
2 1 t
EVAPORATOR
SENSOR
WHI/RED
BLK
CONDENSER FAN
REFRIGERATION CABINET
CONDENSER
P
R
O
B
E
1
BLK ORN t
33 36026 121506
SCHEMATIC WIRING DIAGRAM
LCR-2/LCR-2, PC/LCR-2C/LCR-2C, PC
MASTER ON/OFF
SWITCH
L1
BLK-14 RED-14
N (120V 2-Wire)
L2 (208-240V 2-Wire)
GRN
TUBE
WARMER
TUBE
WARMER
TOUCHPAD
YES (+)
EXIT
NO (-)
5
6
7
3
4
1
2
BLK-14
RED
BLK
BLK
RED
-V
+V
UNIVERSAL
POWER SUPPLY
N(L2)
L(L1)
-V
+V
WHI
BLK
GRN
GRN
RED
LEFT RPM
SENSOR
RIGHT RPM
SENSOR
RED
BLK
GRN
RED
BLK
GRN
RED
BLK
BLU
RED
BLK
VIO
BLK LEFT
PUMP
RED
BLK RIGHT
PUMP
RED
WHI/YEL
YEL
ORN
WHI/ORN
BLK-14
TRIAC
BLU-14
SW. & THERMOSTAT
BLU-14
TANK HEATER
BLK-14
RED-14
1
LIMIT
THERMOSTAT
2
3 4
J14-1
J14-7
VIO
BLU
RED
YEL
ORN
BLK
BLK
RED
WHI/ORN
WHI/YEL
J7-1
J7-5
J7-10
GRN
J8-1
J8-3
J18-1
O
A
C
B
R
D
L
P
R
O
N
T
C
O
PORTION
CONTROL
DOOR
J3-1
WHI/BLU
RED
WHI/RED
J3-6
BLK
J4-5
J5-1
J5-3
J16-1
J4-1
RED
RED/BLK
BRN/WHI
BRN/BLK
WHI/GRY
BLU/BLK
J16-5
BLK
BLK
BLK
BLK
GRN
BLU
ORN
WHI/ORN
WHI/YEL
PNK
J16-12
RED-14
WHI
OVERFLOW
PROTECTION SW
RED RED
WHI/GRY
SOL
RED
HOT WATER
RED/BLK
RED
SOL
BRN/BLK
RIGHT DISP
RED
SOL
LEFT DISP
RED
SOL
BRN/WHI
BLU/BLK
REFILL
WHI/GRY
WHI/YEL
JUMPER
WHI/YEL
WHI/YEL
DISPENSERS WITH PORTION CONTROL
GRN
J18-6
J18-7
J17-4
BLK
YEL
J17-1
WHI/YEL
BLK
BLU
BLK
YEL
1
4
BLK
BLU
BLK
YEL
LEFT
CONDUCTANCE
SENSOR
BLK WHI/ORN BLK
RIGHT
CONDUCTANCE
SENSOR
GRN
LF DISP. SW.
RT DISP. SW.
O
A
R
D
L
E
D
B
C
H
A
N
D
S
W
T
I
J1-1
J1-5
J1-10
J1-16
BLU/WHI
RED/BLK
GRN
ORN/BLK
GRN/WHI
BLK
RED/WHI
BLU/BLK
RED
GRN/BLK
WHI/BLK
ORN
WHI
BLK
SELECTOR
SWITCH
NITE
WHI/GRY
RUN
WHI/VIO
BLK
SELECTOR
SWITCH
RINSE
WHI/YEL
PRIME
TAN
BLK
WHI/BLU
RED
WHI/RED
1
WHI/BLU
RED
WHI/RED
BLK
6
BLK
D
C
+
F
P
-
+
T
120 VOLTS AC 2 WIRE
120/208-240 VOLTS AC 3 WIRE
208-240 VOLTS AC 2 WIRE
SINGLE PHASE 50/60HZ
36025.0003A 01/07 © 2007 BUNN-O-MATIC CORPORATION
Models with Master ON/OFF Switch
1 2 t
CABINET
THERMISTOR
COMPRESSOR
2 1 t
EVAPORATOR
SENSOR
WHI/RED
BLK
CONDENSER FAN
REFRIGERATION CABINET
CONDENSER
P
R
O
B
E
1
BLK ORN t
34 36026 121506
TUBE
WARMER
TUBE
WARMER
TOUCHPAD
YES (+)
EXIT
NO (-)
LEFT RPM
SENSOR
RIGHT RPM
SENSOR
BLK LEFT
PUMP
RED
BLK RIGHT
PUMP
RED
6
7
4
5
1
2
3
L1
RED
BLK
GRN
RED
BLK
GRN
BLK
RED
BLK
CAPACITOR .01uF
GRN
BLK-14
BLK
Fuse 1
BLK
10 AMP
UNIVERSAL
POWER SUPPLY
BLK
RED
-V
+V
SCHEMATIC WIRING DIAGRAM LCR-2A/LCR-2A, PC
GRN
RFI SUPPRESION
CAPACITOR 2.2uF
CAPACITOR .01uF
GRN
BLK
BLK-14
TRIAC
BLU-14
SW. & THERMOSTAT
BLU-14
TANK HEATER
DOUBLE POLE
LIMIT THERMOSTAT
1 2
RED-14
3 4
RED-14
PORTION
CONTROL
WHI
Fuse 2
10 AMP
WHI
N
OVERFLOW
PROTECTION SW
RED RED
N(L2)
L(L1)
-V
+V
WHI
BLK
GRN
GRN
RED
DOOR
J14-1
J3-1
J3-6
WHI/BLU
RED
WHI/RED
BLK
WHI/GRY
SOL
RED
RED
HOT WATER
SOL
RED/BLK
BRN/BLK
RIGHT DISP
RED
SOL
LEFT DISP
BRN/WHI
RED
SOL
BLU/BLK
REFILL
RED
BLK
BLU
RED
BLK
VIO J14-7
J4-1
RED
RED/BLK
BRN/WHI
BRN/BLK
WHI/GRY
WHI/YEL
YEL
ORN
WHI/ORN
WHI/YEL
VIO
BLU
RED
YEL
ORN
BLK
BLK
RED
WHI/ORN
WHI/YEL
GRN
J7-1
J7-5
J7-10
J8-1
J8-3
J18-1
P
C
B
O
A
R
D
R
O
L
N
T
C
O
J4-5
J5-1
J5-3
J16-1
J16-5
J16-12
BLU/BLK
BLK
BLK
BLK
BLK
GRN
BLU
ORN
WHI/ORN
WHI/YEL
PNK
JUMPER
WHI/YEL
WHI/YEL
GRN
J18-6
J18-7
J17-4
BLK
YEL WHI/YEL BLK WHI/ORN
J17-1
LF DISP. SW.
DISPENSERS WITH PORTION CONTROL
BLU/WHI BLU/BLK
BLK
BLU
BLK
YEL
1
4
BLK
BLU
BLK
YEL
LEFT
CONDUCTANCE
SENSOR
WHI/GRY
BLK
RIGHT
CONDUCTANCE
SENSOR
RT DISP. SW.
S
W
I
T
C
H
A
N
D
J1-1
J1-5
L
E
D
J1-10
B
O
A
R
D
J1-16
BLU/WHI
RED/BLK
GRN
ORN/BLK
GRN/WHI
BLK
RED/WHI
BLU/BLK
RED
GRN/BLK
WHI/BLK
ORN
WHI
1 2 t°
CABINET
THERMISTOR
2
GRN
1 t°
EVAPORATOR
SENSOR
P
R
O
B
E
1
BLK ORN t°
BLK
SELECTOR
SWITCH
NITE
WHI/GRY
RUN
WHI/VIO
BLK
SELECTOR
SWITCH
RINSE
WHI/YEL
PRIME
TAN
BLK
WHI/BLU
RED
WHI/RED
1
WHI/BLU
RED
WHI/RED
BLK
6
BLK
C
P
T
+
F
+
-
D COMPRESSOR
WHI/RED
BLK
CONDENSER FAN
CONDENSER
230 VOLTS AC
2 WIRE
SINGLE PHASE
50HZ
36025.0001G 09/06 © 2003 BUNN-O-MATIC CORPORATION
REFRIGERATION CABINET
35 36026 092706
TUBE
WARMER
TUBE
WARMER
TOUCHPAD
RED
GRN
YES (+)
EXIT
NO (-)
6
7
4
5
1
2
3
RED
GRN
+V
-V
UNIVERSAL
POWER SUPPLY
+V
-V
GND
N(L2)
L(L1)
RED
GRN
GRN
GRN
WHI
BLU
BRN/BLK
LEFT RPM
SENSOR
RIGHT RPM
SENSOR
RED
BLK
GRN
RED
BLK
GRN
RED
BLK
BLU
RED
BLK
VIO
BLK
BLK
LEFT
PUMP
RIGHT
PUMP
RED
RED
WHI/YEL
YEL
ORN
WHI/ORN
J14-1
J14-7
BLK
BLK
RED
WHI/ORN
WHI/YEL
VIO
BLU
RED
YEL
ORN
J7-1
J7-5
J7-10
ORN
J18-1
ORN
ORN
ORN
J18-5
J18-9
WHI/ORN
J18-1
WHI/ORN
WHI/ORN
J18-5
J18-9
LF DISP. SW.
RT DISP. SW.
A
N
D
L
E
D
B
O
A
R
D
S
W
T
I
C
H
J1-1
J1-5
J1-10
J1-16
BLU/WHI
RED/BLK
GRN
ORN/BLK
GRN/WHI
BLK
RED/WHI
BLU/BLK
RED
GRN/BLK
WHI/BLK
ORN
WHI
BLU/WHI BLU/BLK
400 VOLTS A.C.
PHASE TO PHASE
230 VOLTS AC
PHASE TO NEUTRAL
3 PHASE 50/60 HZ
BLK
SELECTOR
SWITCH
NITE
WHI/GRY
RUN
WHI/VIO
BLK
SELECTOR
SWITCH
RINSE
WHI/YEL
PRIME
TAN
BLK
36025.0002A 12/06 © 2006 BUNN-O-MATIC CORPORATION
White Strip-Tac Plus
Black Ink
Finished Size: 6" x 7.375"
~ 47% Reduction
L
P
R
O
C
N
T
C
O
A
R
B
O
D
PORTION
CONTROL
DOOR
RED
BLK
TAN
J3-1
WHI/BLU
RED
WHI/RED
J3-6
BLK
J4-5
J5-1
J5-3
J16-1
J4-1
RED
RED/BLK
BRN/WHI
BRN/BLK
WHI/GRY
BLU/BLK
J16-5
BLK
BLK
BLK
BLK
GRN
BLU
ORN
WHI/ORN
WHI/YEL
PNK
J16-12
J17-4
J17-1
36
OVERFLOW
PROTECTION SW
RED RED WHI/GRY
SOL
RED
RED
HOT WATER
SOL
RED/BLK
BRN/BLK
RIGHT DISP
RED
SOL
LEFT DISP
BRN/WHI
RED
SOL
BLU/BLK
REFILL
WHI/YEL BLK
LEFT
CONDUCTANCE
SENSOR
WHI/ORN
RIGHT
BLK
CONDUCTANCE
SENSOR
GRN
P
R
O
B
E
1
BLK ORN t
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Warranty
- 3 Introduction
- 3 User Notices
- 4 Electrical Requirements
- 5 Plumbing Requirements
- 6 Initial Set-up
- 6 Electrical Hook-up
- 6 Plumbing Hook-up
- 7 Setting Dispenser Flow Rate
- 8 Selecting the Correct Pump Tubing
- 9 Operating Controls & Interface
- 10 Initial Fill & Heat
- 11 FlavorGard™ Feature
- 11 Rinse Alarm Feature
- 12 BIB Empty Lockout Feature
- 12 Brew Temperature Lockout Feature
- 13 Programming the Dispenser
- 19 Loading the Concentrate
- 19 Priming the Concentrate Lines
- 20 Operating the Pull & Hold Dispenser
- 21 Operating the Preset Portion Control Dispenser
- 21 Filling Cambros or other large containers
- 22 Cleaning & Preventive Maintenance
- 23 Replacing the Pump Tubing
- 24 Draining the Hot Water
- 25 Troubleshooting
- 30 Field Calibration of the Concentrate Pumps
- 31 Dispenser Flow Rate Calibration
- 31 Field Calibrating the Hot Water Flow Rate
- 32 Field Calibrating the Empty BIB Warning
- 33 Schematic Wiring Diagrams