OPERATING THE PRESET PORTION CONTROL DISPENSER
(Models LCR-2 PC, LCR-2C PC, LCR-2A PC)
Set the Function Selector Switch to Normal and the Mode Selector Switch to Run.
Dispensing Preset Portions of Coffee or Hot Water
1. Primary Volume Portion Dispense Mode. (Volume 1) Refer to Programming Functions on how to set this amount.
a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.
b. Momentarily press the appropriate dispense switch. The dispenser will automatically dispense the beverage at the preset amount. Allow the mix chamber to drain at the end of the cycle.
c. Remove cup or container.
2. Alternate Volume Portion Dispense Mode. (Volume 2) Refer to Programming Functions on how to set this volume.
a. Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup tray up and place the container on top of the drip tray.
b. Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion
Switch is pressed.
c. Momentarily press the corresponding Dispense Switch. If the user waits longer than 5 seconds to push the switch, the dispenser will default back to the Primary Volume preset amount. Alternate Portion
Dispense Mode can be disabled at any time during the portion dispense by either momentarily pushing the Dispense Switch again or pressing the Stop button.
d. Wait for the container to fill and the dispenser to quit dispensing, then remove the container.
Push and Hold Dispensing of Coffee or Hot Water
Push and Hold Dispense Mode. See Programming Functions on how to set the Preset Volume to Zero.
a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.
b. Push and hold the corresponding dispense switch until the container is full.
c. Remove cup or container.
Filling Cambros or other large containers:
The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips.
However, it may be used to fill larger containers (up to 5 Gal) by use of an extension hose on the dispense tip.
Removing the Flow Restrictors will increase the dispenser flow rate to 2.5 Oz/sec. (74 mL/sec.) and reduce the time to fill larger containers, (see Setting Dispenser Flow Rate .)
Care must be taken to insure that the mixed product flows freely from the dispense tip into the container.
1. Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose.
2. Use as short a hose as possible with no loops, bends or kinks in it.
3. Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container
A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube.
NOTE: The temperature of the product being dispensed will start to drop after ~2 gal. continuous draw. Recovery time will be dependent on the temperature of the supply water and the voltage at which the heater coil is being operated.
21 36026 120105
advertisement
Related manuals
advertisement
Table of contents
- 2 Warranty
- 3 Introduction
- 3 User Notices
- 4 Electrical Requirements
- 5 Plumbing Requirements
- 6 Initial Set-up
- 6 Electrical Hook-up
- 6 Plumbing Hook-up
- 7 Setting Dispenser Flow Rate
- 8 Selecting the Correct Pump Tubing
- 9 Operating Controls & Interface
- 10 Initial Fill & Heat
- 11 FlavorGard™ Feature
- 11 Rinse Alarm Feature
- 12 BIB Empty Lockout Feature
- 12 Brew Temperature Lockout Feature
- 13 Programming the Dispenser
- 19 Loading the Concentrate
- 19 Priming the Concentrate Lines
- 20 Operating the Pull & Hold Dispenser
- 21 Operating the Preset Portion Control Dispenser
- 21 Filling Cambros or other large containers
- 22 Cleaning & Preventive Maintenance
- 23 Replacing the Pump Tubing
- 24 Draining the Hot Water
- 25 Troubleshooting
- 30 Field Calibration of the Concentrate Pumps
- 31 Dispenser Flow Rate Calibration
- 31 Field Calibrating the Hot Water Flow Rate
- 32 Field Calibrating the Empty BIB Warning
- 33 Schematic Wiring Diagrams