Page 1 of 1
10 1/8"
(257mm)
14 5/8"
(372mm)
11 3/16"
(284mm)
9" (229mm)
22 3/8"
(568mm)
9 1/2"
(242mm)
9" (229mm)
Plus Ceiling Thk.
Calculite
®
Evolution IC Airseal
®
Frame
C4AICLV
4" Aperture, MR16 (12V)
7 6 2 1 5 3 4
1/2" (13mm) Lip .875" Max (28mm)
Ceiling Thickness
Ceiling Cutout: 5 1/16" (129 mm) Dia.
Frame-In Kit Reflector Trim
Open
Downlight
Adjustable
Accent
Adjustable
2" Aperture
Adjustable
1 1/4" Pinhole
Lensed
Wall Washer
Glasslyte
Downlight
Glasslyte
Adjustable
C4AICLVE1
Electronic 120V
C4AICLVM1
Magnetic 120V
C4MRD
20W-50W
MR16 (12V)
C4MRA
20W-50W
MR16 (12V)
C4MR2
20W-50W
MR16 (12V)
*37W Max with C47CA2
C4MRP
20W-50W
MR16 (12V)
C4MRL
20W-50W
MR16 (12V)
C4MRGD
20W-50W
MR16 (12V)
C4MRGA
20W-50W
MR16 (12V)
Note: Magnetic transformers may produce audible sound when used with dimmers, which may be objectionable in acoustically critical areas.
Lensed
Adjustable
C4MRW
20W-50W
MR16 (12V)
Features
1. Inner / Outer Housings: Inner Housing - Drawn, 0.036" (20 Gauge) steel.
Matte black finish. Housing minimizes air leakage to less than 2 CFM (Cubic
Feet per Minute) at 1.57 PSF (Pounds per Square Foot) (or 75 Pascals), which complies with Model Energy Code and Washington State Energy Code and reduces heat loss and condensation in ceiling. Outer Housing - Die-formed,
0.040" aluminum. Top cover removable for access to transformer. U.L. listed for direct contact with thermal insulation.
2. Mounting Frame: Die-formed, 0.036" (20 Gauge) steel, matte black finish.
Four slots are positioned 90° apart to simplify alignment.
3. Retaining Springs: Steel springs secure reflector trim to mounting frame for tool-less installation.
4. Mounting Bars: Galvanized steel, 0.059" (16 Gauge). Bars pivot for attachment and wire-in below ceiling line. Pre-installed telescoping bars extend to accommodate 16" to 24" on center joist spacing. Integral screws for secure attachment to wood; attach to T-bar ceilings without the need for accessories.
5. Lampholder: Porcelain bi-pin socket. Pre-wired with Teflon leads.
6. Junction Box: 3-1/2" X 4" X 2-3/8" deep; 0.063 (14 Gauge) galvanized steel. UL listed for maximum of (4) No. 12 AWG (American Wire Gauge) 90°
C through branch circuit conductors. Accessible from inside and outside luminaire. Outside J-Box door is hinged for maximum access.
7. Thermal Protector: Meets NEC and UL requirements.
Electrical
Transformer: Replaceable from below; transformer door rotates into fixture, positioning transformer directly over the aperture. Magnetic: 120V 60Hz. core
& coil. Electronic: 120V 50/60 Hz., regulated lamp voltage, HPF (High Power
Factor), EMI (Electro Magnetic Interference) and short circuit protections, thermal auto-reset, quiet operation.
Electrical (cont.)
Dimming Controls: Use only dimmers specifically designed for use with magnetic or electronic transformers. Consult Lightolier Controls division for information. Low voltage luminaries may produce audible sound when used with dimmers.
Accessories
Thick Ceiling Adapter: for .875" - 1.75" thick ceiling capability, utilize C47CA2
Labels
CULUS (Suitable For Damp Locations), U.S. & Foreign Patents pending. Complies with Air Leakage Requirements as stated in the Model Energy Code and the
Washington State Energy Code.
Job Information
Job Name:
Cat. No.:
Lamp(s):
Notes:
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • F0708