9610 SW SUNSHINE CT.

SUITE 800

BEAVERTON, OR 97005

800-211-9001 • 503-748-8700

©2001, PLUS Vision Corp.

428-707-01A

BF-SERIES

COPYBPOARD

BF-030 S / BF-041S / BF-035

BF-030PC / BF 030 W / BF-041W

INSTALLATION MANUAL

• To prevent electrical shock and insure safe wall mounting, please consult your authorized

PLUS dealer on the copyboard assembling and wall mounting methods.

Note: The wall must be capable of holding an object weighing more than 1010N [103 kgf

(about 227 lbs)] for BF-030S, BF-030PC, BF-041S or 1137N [116 kgf (about 256 lbs)]

for BF-030W, BF-035, BF-041W.

Note: Use anchor set and screws suitable for the type of wall to which to copyboard will

be mounted.

(* The wall and its internal structure must be checked because they differ depending

on the building.)

• The following parts are contained in the accessory box. Be sure to check them before

starting installation work.

[Accessories for Mounting to Wall]

Plate Upper bracket Lower bracket

X 2 X 2 X 2

Plate fitting screw Plate/upper bracket fitting screw Pipe frame cap

X 4

M4x 15mm (19/32”)

Tap tight screw

X

M6x 15mm (19/32”)

2

• Before installation: Prepare the anchor set and screws suitable for the type of wall.

(* The wall and its internal structure must be checked because they differ depending

on the building.)

– 1 –

X

2

Checking Installation Position

• The mounting positions to the wall are shown below.

• For the mounting surface, select a flat wall surface.

• The installation height is optional, but an easy-to-use height should be set by checking

the position of the top of the main body

BF-030S, BF-035, BF-030PC, BF-041S 1440mm (4 feet 8 11/16 in.)

BF-030W, BF-041W 1940mm (6 feet 4 3/8 in.)

• BF-030S, BF-035, BF-030PC, BF-041S 812mm (32 in.)

• BF-030W, BF-041W 812mm (32 in.) / 1220mm (48 in.)

Upper bracket metal fitting position

Plate

(to be fit to the main body)

Upper bracket

BF-Series Copyboard Wall Mounting Method

1. First, check that the wall can withstand the weight of the copyboard.

Note: The wall must be capable of holding an object weighing more than 1010N [103 kgf

(about 227 lbs)] for BF-030S, BF-030PC, BF-041S or 1137N [116 kgf (about 256 lbs)] for

BF-030W, BF-035, BF-041W.

Note: Use anchor set and screws suitable for the type of wall to which to copyboard will

be mounted.

(* The wall and its internal structure must be checked because they differ depending

on the building.)

The wall mounting surface must be flat and free from warp and strain.

2. Fit the lower brackets to the wall. (Fig. 2)

The spacing between the lower bracket mounting holes of the wall is 1320 mm (4 feet 3

31/32

in.) for BF-030S, BF-030PC, BF-035, BF-041 or 1820 mm (5 feet 11

21/32

in.) for

BF-030W, BF-041W.

Fit the tow lower brackets at the same height. (See Fig.1)

(* For the fitting position, be sure to check levelness with a level.)

Note: Use anchor set and screws suitable for the type of wall to which to copyboard will

be mounted.

(* The wall and its internal structure must be checked because they differ depending

on the building.)

For fitting the lower brackets, the screws must be firmly tightened.

Important note: The weight of the copyboard is 32 kg or more ([32kgf (70.5 lbs)] for

BF-030S, BF-030PC, BF-041S or 36 kg or more [36 kgf (79.4 lbs)] for BF-030W,

BF-035 and BF-041W. The installation must be made in accordance with this manual,

otherwise injury or damage may occur.

Lower bracket metal fitting position

• BF-030S, BF-035, BF-030PC, BF-041S 1320mm (4 feet 3 31/32 in.)

• BF-030W, BF-041W 1820mm (5 feet 11 21/32 in.)

Lower bracket

Floor

Fig. 1

– 2 –

Wall

– 3 –

BF-030S, BF-035, BF-030PC, BF-041 1320mm (4 feet 3 31/32 in.)

BF-030W, BF-041W 1820mm (5 feet 11

21/32

in.)

Make holes for fitting the lower brackets.

(2 holes each right/left, totalling 4 holes)

Level line

3. Fit the board plates to the copyboard.

The spacing between the holes for fitting the board plates is 812 mm (32 in.) for BF-030,

BF-030PC, BF-035, BF-041S or 812 mm (32 in.)/1220 mm (48 in.) for BF-030W and

BF-041W).

The screws for fitting the board plates to the copyboard must be firmly tightened.

(Tightening torque 8 kgf or more)

BF-030S, BF-035, BF-030PC, BF-041S 812mm (32 in.)

BF-03W, BF-030S 812mm (32 in.)/1220mm (48 in.)

Tap tight bind head

4 x 15 (4 pcs.)

Tighten using anchor screws suitable for type of wall

– 4 –

4. Fit the upper brackets to the board plate at the top of the copyboard.

Pan head screw + washer

M6 x 15 (2 pcs.)

– 5 –

5. Mark the board plate fitting hole positions on the wall. (Fig. 5)

• Place the copyboard on the lower brackets.

Mark the board plate fitting hole positions on the wall.

Lower the copyboard, drill pilot holes for anchor screws at the board plate fitting hole

positions marked on the wall, and install the anchor screws.

6. Place the copyboard on the lower brackets and fit the upper brackets to the wall. (Fig. 5)

When the copyboard is installed do not press it strongly against the wall, etc.

The fluorescent tub, etc. inside the copyboard may be damaged.

Anchor position

7. Install the pipe cap at the right and left of the copyboard. (Fig, 6)

Note: After the copyboard is installed, check the integrity of the mounting by applying

light force to the copyboard to confirm that is sufficiently mounted

Pipe cap

Anchor screw

Pipe cap

Fig. 6

– 6 –