INSTALLATION

AND

OPERATING INSTRUCTIONS

P/N 80900 - REV. 12/03

IPROPANEGAS VC202A VC352A VCS02A IVC702A lVCR352A IVCRS02A

This appliance is equipped with a safety control system designed to protect against improper venting of combustion products.

THIS UNIT IS NOT TO BE INSTALLED IN MOBILE HOMES.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

IVCR702A

Do not store or use gasoline or other flalr_nable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

RADIANT FRONT

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• hnmediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire department.

CLOSEDFRONT

INSTALLATION AND SERVICE MUST BE

PERFORMED BY A QUALIFIED INSTALLER,

SERVICE AGENCY OR THE GAS SUPPLIER.

to the heat exchanger may smoke slightly lation if this occurs.

WARNING: Operation of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safety shut-off system can result in Carbon Monoxide

(CO) poisoning and possible death.

This unit is not approved for installation in mobile homes, greenhouses, or environments dust); wet, corrosive, or explosive create unsafe conditions.

conditions.

involving

Such conditions will invalidate the warranB T and may

SPECIFICATIONS............................

INTRODUCTION.............................

2

3

VENTING.......................................

GAS StJPPLY..................................

LOCATION & SPECIAL PRECAUIIONS 5

COMBUSTION & VENTILATION AIR ....

6

3,4

5

CLEARANCES................................

DRAFTD1VERTER..........................

I_ORKNOB .................................

PILOTADJUSTMENT ......................

7

8

7

7

TABLE OF CONTENTS

RADIANTS & GLASS PANELS...........

8

BURNER ORIFICE & ORIFICE CHART.......... 8

PROPER BURNER FLAME ..........................

9

MAINTENANCE .....................................

9

LIGHTING INSTRUCTIONS .......................

10

TROUBLE SHOOTING CHART ............

BLOWER INSTRUCTIONS ..................

PARTSDRAWING.............................

PARTSPRICE LIST............................

WARRANTY....................................

11,12

13

14

15

17

READ CAREFULLY BEFORE INSTALLING UNIT

These installation instructions are a general guide and do not supersede applicable local codes and ordinances.

Before planning or making the installation be sure it complies with all phases of the local heating code.

(Or, in the absence of local codes, with the latest edition of National Fuel Gas Code, ANSI.Z223.1, or CAN1-B 149).

The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the latest edition of National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code CSA-C22.1.

All of the ANSI and NFPA standards referred to in these installation instructions are the ones that were applicable at the time the design of this appliance was certified.

The ANSI standards are available from the American Gas Association,

1515 Wilson Blvd., Arlington, VA. 22209.

The NFPA standards are available from the national Fire Protection Association, 60 Batterymarch Street, Boston,

Massachusetts 02110.

Canadian standards are available from International Approval Services, 178 Rexdale Boulevard, Etobicoke, Ontario,

Canada M9W 1R3.

The design of this appliance was certified to comply with ANSI Z21.11.1

vented room heaters and CAN1-2.1-M86.

Installer must leave these instructions with the consumer, have them complete, and return the warranty card.

ROOM HEATER SPECIFICATIONS

Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model Number is correct and that the room heater is equipped t\_r the type gas you intend to use.

SPECIFICATIONS

TYPE CONTROL GAS MODEL NUMBERS

CLOSED FRONT THERMOSTAT BULB NATURAL

CLOSED FRONT THERMOSTAT BULB L.P

RADIANTFRON1 THERMOSTAT BULB NATURAL

RADIANTFRON1 THERMOSTAT BULB L.R

HEIGHT

WIDTH

DEPTH

VC201A

VC202A

N/A

N/A

20"

24"

15-1/4"

VC351A

VC352A

VCR351A

VCR352A

26"

30"

15-1/4"

VC501A

VC502A

VCR501A

VCR502A

26"

30"

19-1/4"

VC701A

VC702A

VCR701A

VCRT02A

30"

36"

19-1/4"

INPUT (BTU/HR.)

GAS INLET/OUTLET SIZE

VENT SIZE

CENTER OF VENT TO FLOOR

NUMBER OF RADIANTS ("VCR" SERIES)

NUMBER OF RADIANT GLASS _"VCR" SE___.ES_

APPROX. SHIPPING WEIGHT ("VC" SERIES)

APPROX. SHIPPING WEIGHT ("VCR" SERIES)

*OPTIONAL BLOWER MODEL

20,000

1/2X3/8"

3"

16-1/2"

N/A

N/A

55 LBS.

N/A

N/A

35,000

1/2X3/8"

4"

21-1/2"

5

2

84 LBS.

96 LBS.

CHB-3

50,000

1/2X3/8"

4"

21-1/2"

5

2 ll2LBS.

124 LBS.

CHB-3

70,000

1/2X3/8"

5"

25-1/2"

5

2

138 LBS.

150 LBS.

CHB-3

*Blowers also available factory mounted on 50M Btu units. All 70M Btu units come with blower mounted only.

Page 2

INTRODUCTION

THIS IS A GAS-FIRED, GRAVITY VENTED ROOM HEATER THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT

SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION

AND OPERATING INSTRUCTIONS. READ THESE INSTRCTIONS THOROUGHLY BEFORE INSTALLING, SERVICING, OR

USING THIS APPLIANCE.

IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS, CONSULT LOCAL

AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE AGENCIES, THE GAS SUPPLIER, OR THE MANUFACTURER.

VENTING

This heater must be connected to a properly installed and maintained venting system. This heater is equipped with a vent safety shut-off device. Pilot outage will occur if the heater is not connected to a vent system. Pilot outage _ occur due to restriction or blockage in the vent or if connected to a masonry chimney having an area reeater than the vent size shown on Page 2.

This appliance should be vented through a properly sized listed type B vent that has been constructed in accordance with the

National Building Code. Ifa horizontal section of vent is used, it must slope upwards a minimum of ¼ inch per t\_ot of length.

This heater must not be connected to a vent system being used t\_r wood or coat burning appliances.

The use of more than one appliance per vent system will most likely cause the vent safety shut-off device to shut off the heater due to the cooling of vent temperatures through the draft diverter of the second appliance.

In some situations, the vent safety shut-off may shut do,am the heater ifa too large, unlined, masonry chimney is used. Due to low vent temperatures associated with more efficient heaters it may take too long to get the vent action going in a chimney before the shut-off device will shut down the heater. If this is the case, we recommend lining the chimney with the proper size type B vent pipe or type B chimney liner.

WARNING: Do not bypass the vent safety shutoff switch. To do so could expose the consumer to property damage, personal injury or possible death.

The switch, when activated, will extinguish the pilot flame. If the homeowner experiences this problem, the vent system must be checked and corrected.

NOTE: An existing vent that has worked for years may not be adequate for todays design because of higher efficiency requirements resulting in lower stack temperatures.

The following is a list of possible causes and corrective actions.

POSSIBLE CAUSES

1. Blockage in vent pipe

2. Burner is over firin

3. Improper vent system

A) Vent too short

B) Restriction in vent system caused by ofl_ets

C) Incorrect vent pipe

4. Loose connections on the vent safety wiring harness

1.A)

1.B)

2.A)

2.B)

3.

A)

B)

O

4.

CORRECTIVE ACTION

Check vent pipe t\_rblockage, such as bird nest, wasp nest, twigs, leaves, etc.

Check that the vent cap is properly installed, not shoved too far down on the vent pipe.

Check the manifold pressure.

Check the rate, NOTE: This appliance was orificed for elevations up to 2,000 feet.

When installed at higher elevations refer to orifice chart in main burner orifice section of instructions for proper oririce size and re-orifice accordingly.

Correct vent system.

The vent should not terminate less than 5 feet above the drafthood connection.

A gas vent extending through an exterior wall shall not terminate adjacent to the wall or below eaves or parapets.

Also, the top of the vent must be at least 2 foot above any obstacles within a 10 t\_ot radius, including the root'. See Fimlre A.

All type "B" vent shall extend in a generally vertical direction with o fl;ets not exceeding 45 de mees, except that a vent system having not more than one 60 de_ee oft;et may be allowed. A W angle greater than 45 degrees fiom the vertical is considered horizontal.

The total horizontal run of a vent plus the horizontal vent connector shall be not greater than 75 percent of the vertical height of the vent.

Any oft;ets used should be as tar above the drat'thood as possible to allow a venting action to begin bel\_re a W restriction is encountered.

Use listed "B" type vent pipe. Do not use transite or any other type of ceramic pipe for venting. Do not use single wall pipe.

Check the connection on both the switch and the gas valve. Tighten if necessary.

Page 3

VENTING

Ridge

Chhnney --

FIGURE A

Termination of vent must be securely guyed or braced if it extends more than five (5) feet above roof.

Seat around collar

& flashings

See

Termination rZ3 i

' I

FIGURE A

CONNECTING

AN EXISTING

THE VENT INTO

CHIMNEY

SAFE (See "Venting"}

NOTE: This lnay result in the vent safely switch shutting down the pilot depending on size and draw of chimney.

i

I i i i i i

I

.1/4

Maintain l"Clearance

FIGUNE 7A

UNSAFE

I

I i

N

I

I I

Terminate vent at least 5 ft.

above draft

\

Firestop Support

Assembly

Vertical Vent

Elbow

FIGURE 7B

RECOMMENDED

Use proper size "B" pipe or chimney liner inside chimney.

i i m m m m m m

Page 4

FIGURE 7C

I

I

I

GAS SUPPLY

This vented room heater must be connected to a gas supply capable of supplying the appliances full rated capacity.

Provide a 1/8 inch N.RT. plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the appliance.

The minimum inlet pressure in the gas supply pipe should be 4.5" w.c. for

Natural Gas and 11.0" w.c. for Propane Gas, "for the purpose ofinput adjustment". The maximum inlet pressure in the gas supply pipe should never exceed 14" w.c. for either Natural or Propane Gas. The gas supply piping should be sized in accordance with ANSI Z223.1 National

Fuel Gas Code. The norlnal manifold pressure should be

3.5" w.c. for Natural Gas and 10.0" w.c. for Propane

Gas.

If the outlet pressure of the gas valve must be adjusted, this should be done by a qualified serviceman using proper tools and instruments.

Check all connections with soapy water for possible gas leaks. Never use a match, candle or other ignition source.

It is recommended that pipe compound which is resistant to the action of liquefied petroleum gases be used.

Do not use Teflon tape or Teflon impregnated compound.

The appliance and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at the test pressure in excess of 1/2psig.

The appliance must be isolated from the gas supply piping by closing its individual manual shutoffvalve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2psig.

LOCATION AND SPEICAL PRECAUTIONS

Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance.

Clothing or other flalranable material should not be placed on or near the appliance.

Any safety screen, guard, or casing top removed for servicing a room heater must be replaced prior to operating the appliance.

Do not use this heater if any part has been under water, hr_nediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

For purpose of identifying the sides of the heater.

When you are Pacingthe front of the heater the right side has the access door and the left side is solid.

If heater is installed in a residential garage, all burners and pilot must be above 18". Locate or protect heater so it cannot be damaged by a moving vehicle.

Page 5

COMBUSTION AND VENTILATION AIR

When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minilnum required volume of the area where the appliance is installed should be 50 cubic feet per

1,000 btu/hr.

If installed in an area of the home that is considered an unconfined space, the natural infiltration of air around windows and doors will be adequate.

If the area is considered a confined space (less than 50 cubic feet per thousand btu), tiesh air can be supplied by providing two permanent openings into adjoining rooms.

Each opening shall have a lninilnum free area of one square inch per

1,000 bm per hour of the total input rating of all gas appliances in the confined space, but not less than 100 square inches. One of the openings shall be within

12 inches of the ceiling and one within 12 inches of the floor. See Figmre A.

If the home is ofunusually tight construction (new and remodeled homes), tiee air must be supplied through opening(s) to the outdoors.

This can be accomplished by providing 2 permanent openings, one commencing within 12 inches of the ceiling and one within 12 inches of the floor. These openings shall comlnunicate directly with the outdoors, or spaces that comlnunicate freely with the outdoors, such as a ventilated attic and crawl space through galvanized or equivalent corrosion-resistant ducts. Exception: unobstructed stud and joist spaces are acceptable ducts provided that not more than one tire block is removed.

Special provisions must be taken to insure that these stud and joist spaces cannot be blocked with insulation or other objects.

Each of these openings using vertical ducts shall have a minilnum free area of one square inch per 4,000 btu/hr of total input rating of all gas appliances.

See

Figmre B and C. If horizontal ducts are used, the minimum tiee area shall be one square inch per 2,000 btu/hr of total input rating of all gas appliances.

Fresh make-up air can also be provided through a duct to one permanent opening commencing within 12 inches of the ceiling. The minimuln tiee area of this opening shall be one square inch per 3,000 btu/hr of the total input rating ofalt gas appliances but not less than the sum of the areas of all vent connectors in the space. See Figure D.

When calculating the amount of fresh air needed you must include make-up air requirements for the operation of exhaust tans, kitchen ventilation systems, clothes dryers, and fireplaces.

Additional intbnnation can be t\_und in the latest edition of ANSI Z223.1

(National Fuel Gas Code).

ALL COMBUSTION AIR FROM OUTDOORS

THROUGH VENTILATED ATTIC

UL Listed Vent Cap

Gas Vent

(each end of attic)

FIGURE A

,_

ALL COMBUSTION AIR FROM

ADJACENT INDOOR SPACES

THROUGH INDOOR COMBUSTION

AIR OPEN1NGS

Listed Vent Cap

Opening

ALL COMBUSTION AIR FROM

OUTDOORS.

INLET AIR FROM

VENTILATED CRAWL SPACE AND

OUTLET AIR TO VENTILATED ATTIC

/UL Listed Vent Cap

' pUL Listed Gas Vent

Ventilation Louvers

_1[_1

II Irr .

end of attic"

-,,-!,==

Outlet Air

-'-Inlet Air

.........

l,l,,,f • -•

FIGURE B

Uventilationlouvers for unheated crawl space

ALL COMBUSTION

THROUGH SINGLE

AIR FROM

COMBUSTION

OUTDOORS

AIR OPENING

• UL Listed Vent

Outlet Air

Inlet Air Duct (Ends 1 Ft.

[300 1rim] above floor)

Opening

Alternate opening location

FIGURE C Page 6 FIGURE D

DRAFT DIVERTER

The draft diverter must be installed in the same atmospheric pressure zone as the combustion air supply for the main burner.

DOOR KNOB

Remove frolTl the inside of the casin_ door and assemble to the outside of the door. VC201 and VC202 have fin_er holes in the door in lieu of knob.

34 IN. T

86.36CM

CLEARANCES - VC20, VC35, VCR35

31IN. I

78.7 CM

4" 18 IN"

45.72 CM

{

CLEARANCES

If the area where the appliance is to be installed contains carpeting, tile, or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate

(stoveboard), a wood panel, or other non-combustible materials.

The use of ceramic or quarry tile is acceptable and provides an appealing surface that is easily cleaned.

This material is to extend 2 inches flom each side and 12 inches from the fiont. It is advisable to extend this to the wall behind the appliance.

Clearances to combustibles are as follows:

From jacket to adjacent side walls, 2" on the 20/35, and

6" on the 50/70. Maintain adequate clearance on right side for accessibility.

From rear surface vertical vent pipe to rear walls 6".

From rear of unit to rear walt, 13" on 20/35, and 14" on the 50/70.

• From top ofheater to ceiling, 34" on the 20/35, and 31" on the 50/70.

From top of heater to aW overhanging projections such as a mantle or window silt is 22" on the 20/35, and 19 inches on the 50/70 models, with a maximum horizontal extension of 18 inches.

The clearances around the air openina into the combustion chamber must be maintained and the burner must be kept clean.

Do not permit dust or dirt to accumulate here.

The other clearances previousN mentioned must be maintained.

There must be adequate room provided and maintained around the heater for accessibility and t\_r the flow of combustion and ventilation air.

?LEARANCES

- VC50 & VC70,

VCR50 & VCR70

Page 7

The pilot flame can be obsel_Ted by opening the pilot lighting hole cover. The pilot flame should surround the top 3/8 to V_, inch of the thennocouple (see Fimlre 2). If the flame needs adjusting, first locate the pilot adjustment screw cap and relnove.

Adjustment screw is underneath (see Fire,re 1). To increase the flame, turn the pilot adjustment screw counterclockwise I_'-N.

To decrease the flame, mm the screw cloc_vise i"'A.

NOTE:

The pilot is unremllated. If incoming line pressure is more than

7" w.c. Natural Gas or 11" w.c. for L.R Gas, the pilot flame size should be decreased.

FIGURE 1

PILOT ADJUSTMENT

PILOT FLAME

ADJUST-

MENT

Pilot tlmne should envelop

3/8 to 1/2 inch on the tip of the enerator.

FIGURE 2

_I "

Screw o÷N ?

Pilot Adj.

t

3/8 TO

1/2 INCH

RADIANTS AND GLASS PANELS

FOR ALL VCR MODELS

(See Figure 9 Replacement Parts Section)

INSTALL GLASS AND RADIANTS AS FOLLOWS:

STEP 1. Remove three screws liom under top of opening in bezel t_rameassembly.

STEP2.

Pull top ofbezeI down and lay aside.

STEP 3. Remove glass liom bottom pad in shipping carton.

STEP 4. Remove carton containing radiants liom cavity of combustion chamber.

STEP 5. Remove radiants from carton and install by tilting backwards and lilting at the same time into opening. Place the radiants on the burner radiants supports.

The radiants must be straight.

Never operate heater if any radiant is tilted to liont or rear.

Continued

MAIN BURNER ORIFICE

This appliance was shipped from the factory with an orifice sized to give the correct gas input using the gas for which the heater was equipped. There may be local conditions, such as variation in gas pressure or BTU content of the gas, which may be cause for a change in the orifice.

The gas company supplying the fuel or the installing contractor should check the gas input rate.

If the rate exceeds the "BTUH INPUT" on the rating plate by

5%, the orifice should be replaced with a smaller orifice by a qualified technician to reduce the input to the rating plate value.

The input rate may need to be adjusted for elevation. See the following charts to determine the correct orifice size t\3ryour

Model Number and elevation.

These orifice sizes are based on a heating value of 1020 for Natural Gas and 2500 for L.P.

Gas.

CAUTION: As elevation increases, derating is necessary for the sate and proper operation of this heater. Do not increase the Btu input rate by increasing the orifice size or gas pressure. Allow for elevation derating when sizing gas heating equipment.

NATURAL GAS

SPECIFIC ELEVATIONS

Model 0to 2,0004,0006,000-

No.

2,000' 4,000' 6,000' 8,000'

8,000'

10,000'

VC201

VC351

45

35

47

37

48

38

49

40

VC501

VC701

30

25

VCR351 35

VCR501 30

31

27

37

31

31

28

38

31

32

29

40

32

VCR701 25 27 28 29

ORDER KIT #49820 45-1 HIGH ALTITUDE KIT

50

42

35

30

42

35

30

L.P. GAS

SPECIFIC ELEVATIONS

Model 0 to 2,000-

No.

2.000' 4,000'

VC202 1.31rnn

55

VC352 1.651rnn

VC502

VC702

47

41

VCR352 1.651rnn

VCR502 47

VCR702 41

49

42

53

49

42

53

4,000 6,000 -

6,000'

56

8,000'

56

53

49

43

53

49

43

54

50

44

54

50

44

8,000'

10,000'

57

54

51

46

54

51

46

ORDER KIT #49820 45-1 HIGH ALTITUDE KIT

STEP 6. Install glass panels by inserting top edge into upper retainer and lower into bottom support, and slide glass into position.

Do not allow a crack between the two glass panels.

Never operate heater with either glass missing or cracked.

STEP 7. Re-install bezel by placing bezel tabs over lower liont and swing bezel into position and secure with three screws.

1

Page 8

CAUTION: Theremaybemomentaryandspasmodic of air bornedustparticlesandis notto beconfusedwith

FIGURE 3

PROPER BURNER FLAME

INNER MANTLE 1/4"

OUTER MANTLE 3 5"

SERVICE RECORD

(;LEANING: To clean the front casing of your heater, it is only necessary to use a soft cloth. Light dust can be removed in this way. To obtain a polish or gloss, use a little light machine oil on the cloth. Do not use metal polish or cleaning solution. The burner ports should be kept fiee tiom lint and dust.

CLEANING OF COMBUSTION CHAMBER

The combustion chamber of your console heater should never need to be cleaned if proper burner adjustment and gas pressures are maintained.

However, if an unusual circumstance should occur, the following procedure should be t\_llowed in cleaning your combustion chamber.

1.

Turn off gas supply to heater at manual valve in supply line to heater.

2.

Disconnect heater at ground joint union ahead of main gas valve.

3.

Remove main control and orifice asselnbly.

4.

Remove burner.

5.

Remove combustion chamber.

6.

Using a scraper, scrape inside of a primary combustion chamber.

This should be area of heaviest accumulation of carbon.

7.

Remove plug bottom located in bottom rear of second combustion chalnber. Using a bottlebrush, clean inside of this chamber. Shake residue out the clean-out hole.

8.

Clean the rear chamber by using bottlebrush through the vent tube openings.

9.

Replace combustion chamber, burner and control.

Check all gas piping for leaks before lighting heater.

Repair service should be perforlned by qualified persons.

The heater should be inspected before initial use. An annual cleanin_ of control compartlnent and safety perforlnance check should be made by a qualified service person. More fiequent cleaning may be required when exposed to the excessive lint conditions due to carpeting and beddin_ material, etc. It is imperative that the control compartlnent, burners, and circulatin_ air passageways of the heater be kept clean. Any safety screen, casing top, or guard removed t\_r selwicin_ the heater must be replaced prior to operating heater.

If the venting system is not maintained in proper operating condition, the vent safety shutoff will not allow heater to operate. Periodic examination of the entire venting system as a routine part of the safety pert\_rmance check is recommended on an annual basis.

It is advised that the pilot and main burner flames be checked at least twice during the heating season tbr any changes in flame characteristics.

See Figure 2 and Figure 3.

THIS IS A GAS-FIRED APPLIANCE, KEEP THE AREA CLEAR OF GASOLINE AND OTHER FLAMMABLE

VAPORS AND LIQUIDS.

ALL COMBUSTIBLE MATERIAL MUST BE KEPT CLEAR OF THIS AREA.

HAVE A QUALIFIED SERVICEMAN CHECK THE BURNER PERIODICALLY.

IF NECESSARY.

REMOVE AND CLEAN

Page 9

1.

2.

MODELS: VC201A, VC202A, VC351A, VC352A, VC501A, VC502A, VC701A,

VC702A, VCR351A, VCR352A, VCR501A, VCR502A, VCR701A, VCR702A

FOR YOUR SAFETY READ

BEFORE LIGHTING

If you cannot reach your gas supplier, call the fire department.

I

A.

This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B.

BEFORE LIGHTING smell all axouM the appliance area tbr gas.

Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Ilnmediately call your gas supplier from a neighbor's phone.

Follow the gas supplier's instructions.

C.

Use only your hand to push in or mm the gas control knob.

Never use tools.

If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician.

Force or attempted repair may result in a fire or explosion.

D.

Do not use this appliance if any part has been under water.

hnmediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

STOP! Read the intbnnation on the safety label.

Turn temperature control knob to "OFF" or it's lowest position.

Depress and turn gas control knob clockwise

/"X to "OFF" position.

Pilot is located on end of combustion chamber above burner.

5.

6.

7.

8.

1.

2.

Gas Control Knob

NOTE: Knob can not be turned fioln

"PILOT" to "OFF" unless knob is pushed in slightly.

Do not force.

Push in gas control kmob and hold in. hnlnediately begin a series of pushing and releasing the red piezo iNlitor button, while observing the pilot.

Continue to spark until pilot is lit. Continue to hold the gas control knob in for about one (1) minute after the pilot is tit. Release the gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 3 thin 9.

Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the inforlnation on the safety label. If you don't smell gas, go to the next step.

Open casing door and pilot lighting hole cover.

Findpilot. (Followmetalpitot robe fiom gas control).

Locate red piezo ignitor button on top of heater.

Turn gas control knob countercloclcvvise _

"PILOT".

to

10.

11.

12.

If knob does not pop up when released, STOP and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

Close pilot lighting hole cover and casing door.

Turn gas control knob counterctoclcvvise to "ON".

Turn telnperature control knob to desired setting

TO TURN OFF GAS TO APPLIANCE

Turn the telnperature control knob to it's lowest setting.

Push in gas control knob slightly and turn clockwise /'N to "OFF". Do not force.

Page 10

TROUBLE SHOOTING CHART for qualified serviceman - MAIN BURNER

SYMPTOM

Flame too large

Noisy Flame

Yellow tip flames (Some yellow tipping on LP Gas is permissible)

2. Burr in orifice (if it whistles or resonates).

3. Excessive gas input.

1. Clogged main burner ports.

2. Clogged draft hood.

3.

Linted up air shutter.

Floating Flame

Gas Odor

Delayed Ignition

Failure to ignite

Condensation of water vapor.

Burner won't turn off

POSSIBLE CAUSES

1. Defective operator section of gas valve.

2. Burner orifice too large.

3. Pressure regulator malfunction.

Noisy pilot.

i.

Blocked venting.

1. Chinmey or flue obstruction.

2. Drafts around heater.

3. Gas leak.

i.

Pilot flame too small.

2. Burner ports clogged near pilot.

3. Low gas pressure.

4. Pilot decreases in size when main burners come on.

5.

Drafts around unit.

6. Pilot lighter door open causing disturbance of pilot flame.

7.

Improper venting.

8. Pressure regulator malflmction.

1. Main gas off.

2. Defective gas valve.

1. Improper venting.

l.

2.

Defective or sticking automatic valve.

Excessive gas pressure (The supply gas pressure must not exceed 1/2 psi or 14" water column).

CORRECTIVE ACTION

1. Replace complete valve.

2. See orifice chart to determine the correct orifice size for your Model Number and elevation.

3. Regulator must be adjusted by a qualified serviceman usin_ proper tools and instruments.

2.

3.

1. Reduce pilot gas with adjusting screw on combination gas.

(Fig.

1).

Remove burr or replace

See "Flame Too Large", orifice above.

(Do not enlarge orifice).

1.

Clean main burner ports (Do not enlarge ports).

2.

Clean draft hood.

3.

Check for dust or lint at air mixer the shutter.

opening and around i.

Clean flue passageways

1. Clean flue.

2. Eliminate drafts.

to relieve blockage.

3. Shut offgas service immediately.

Check piping.

Call gas company.

See "For Your Safety" (Page 1), and

"Gas Supply" (Page 3).

1. Check pilot orifice, clean, increase pilot gas flow if necessary by adjusting at colnbination control valve

(Fig.

1).

2.

Clean burner ports (do not enlarge ports).

3.

Check gas supply pressure.

See "Gas Supply".

4.

Supply piping is inadequately sized.

Consult local gas utility or competent installer.

5. Eliminate drafts.

6. Close pilot lighter door.

7. See "Venting" (Page 2).

8. Regulator must be adjusted by a qualified serviceman usin_ proper tools and instruments.

1. Open all manual gas valves.

2. Replace gas valve.

1. See "Venting".

i.

Clean or replace valve.

2.

To con'ect this situation contact the gas company supplying the gas.

See "Gas Supply".

TROUBLE

Incorrect gas input

SHOOTING CHART - POOR HEATING RESULTS

I. Gas input not checked.

2. Clogged orifice.

3. Pressure regulator.

4. Thermostat capillary tube damaged.

Page 11 i.

Re-check gas input.

See "Gas Supply".

2. Check orifices for clogging.

If clogged, clean out the hole carefully with a smooth wood toothpick.

(Do not in any way enlarge or distort it).

3. Regulator must be adjusted by a qualified serviceman using proper tools and instruments.

4. Replace gas valve.

TROUBLE

SYMPTOM

Not enough heat

Too nmch heat

SHOOTING

i. Heater undersized.

CHART

POSSIBLE CAUSES

2. Temperature dial set too low.

3.

Incon'ect gas supply pressure.

- POOR HEATING RESULTS - Cont'd.

CORRECTIVE ACTION i.

This is especially true when a dwelling or room is enlarged.

Have the heat loss calculated and compare to the heater output (70% of input).

Your gas company or installer can supply you with this information.

If heater is undersized, replace with correct size unit.

2. Raise setting of temperature dial.

See "Lighting and

Shutting Down Instructions".

3.

Check gas supply pressure and regulator pressure as outlined above.

1. Temperature dial set too high.

2. Combination control valve sticks open.

1. Lower setting of temperature

Shutting Down Instructions".

2. Replace combination dial.

control valve.

See "Lighting and

TROUBLE

Burner won't light

SHOOTING CHART - AUTOMATIC

l.

Pilot flame too large or too small.

2.

Defective combination control valve.

PILOT & VALVE

1. Re-adjust pilot flame using adjustment on combination control valves (See Fig. 1 & 1A).

2. Replace valve.

Pilot outage

Pilot will not stay lit when control knob is released

1.

2.

Dirt in pilot orifice.

3.

Pilot lighter door open.

Defective automatic pilot section in combination control valve.

4.

Defective thermocouple.

5.

Vent safety shut off system.

1.

Pilot flame too large or too small.

2.

3.

4.

Defective thermocouple.

Defective gas valve.

Loosen connections at spill switch or

ECO on gas valve.

1. Clean pilot orifice with air or solvent, do not ream.

2. Close pilot lighter door.

3. Replace combination control valve.

4. Replace thermocouple.

5. See "Venting" section.

1. Re-adjust pilot flame using adjustment on combination control valves (See Fig. 1 & 1A).

2. Replace thermocouple.

3. Replace gas valve.

4. Tighten connections.

Page 12

CHB-3 BLOWER INSTALLATION

STEP 1. Run black wire and white wire that comes froln bottom of junction box down through the heat shield. See Figure A.

STEP 2. Insert junction box into opening in back of heater. Attach using tour #8xl/2" black screws provided.

See Figure A.

STEP3.

Attach fan switch to tan switch bracket using two #8xl/2" plated, Phillip head screws provided.

The 2" flange on the bottom of bracket and terminals on the tan switch should be toward the back of the heater when properly installed.

STEP 4. Locate the two engagement holes in base of heater. On a 35,000 Btu heater these holes are approximately 6-1/2" tiom the back edge and right and left holes are 5-1/4" and 7-1/4" respectfully fioln the right side (as viewed from back ofheater). On a 50,000 Bm heater the holes are approximately 10-3/4" tiom the back edge and right and left holes are 5-3/8" and 7-3/8" respectfully tiom the right side. Attach tan switch bracket to base using two #8x 1/2" hex head screws provided. This will require a ¼" socket and ratchet.

See Fibre A.

STEP 5. Locate the blower opening and mounting tab on the base of the heater. Insert the front flange of the blower housing under the mounting tab, lower the back of the blower down onto the base alimling the clearance holes in the blower base with the engagement holes in the heater base. Secure the blower to the base with two #8 screws provided.

See fimlre A.

STEP 6. Connect black wire from junction box to right tan switch terminal. See Figure B.

STEP 7. Connect white wire from junction box to white tan motor wire. See Figmre B.

STEP 8. Connect black wire from tan motor to left tan switch terlninal. See Figmre B.

STEP9.

Turn variable speed control switch clockwise €'N (as viewed from front of unit) to "OFF".

STEP 10. Plug power cord into 115 M grounded receptacle.

STEP 11. Turn variable speed control switch counterclockwise _ (as viewed tiom front of unit) tioln "OFF" to "HIGH". Blower wilt now cycle on automatically when the switch temperature is met after the main burner comes on. The blower will continue to run for a short period after the main burner goes off. Blower speed can be adjusted by setting the variable speed control switch between high and low.

WARNING: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly _ounded three-prong receptacle.

Do not cut or remove the _ounding prong tioln this plug.

CAUTION: Label all wires prior to disconnection when servicing controls.

Wiring errors can cause ilnproper and dangerous operation. Verify proper operation after servicing.

Junction

Box

Speed

:_l MOTOR SWITCH

FIGURE A

_Pov_Ter

Cord

Fan Switch

Bracket

Housing

Page 13

WHITE

BLACK

GREEN

MOTOR SPEED/[-_

CONTROL

"If any part of the original wire as suppied with the appliance must be replaced, it must be replaced with a wire of at least a 105 degree C temperature rating."

FIGURE B

MODELS INCLUDED:

VC / Closed Front Circulators

VCR/Radiant Front Circulators

CHB3 Blower

VENTED CONSOLE HEATER

Prices and specifications subject to change without notice. All prices are F.O.B. factory.

Mr.

Contractor, we only sell parts through our wholesalers, but the prices listed are for your convenience.

For prompt parts service, contact the wholesaler fi:om which you purchased your Cozy heater.

NOTE: Parts & schematic drawings on current models are shown at www.cozyheaters.com

REV. 08/01

Page 14

2

NOTICE: When ordering any component in the control train assembly, specify either

Honeywell or Robertshaw components.

HOW TO PROPERLY information can be found on the

MODEL N[ MBER

ORDER PARTS: In addition to part description

_late that is attached

NAT.

L.E

REF.

to rear of heater.

VC201A-R

VC202A-R

PART LIST and part number, please

VC351,VCR351A-R

VC352_VCR352A-R

PART LIST gixe model number, and type of gas used.

VC501,VCR501A-R

VC502NCR502A-R

PART LIST

VC701,

VC702.

PART

VCR701A-R

VCR702A-R

LIST

This

PART DESCRIPTION

Valve, 7000ASTR-4, Nat. Gas

\1five, 7000ASTR-4, L.P.

Gas

Pilot Assy. 0.140.504

L.P.Gas

Pilot Assy. 0.140.514

Nat.Gas

Manifold

Orifice Nut

Burner Orifice.

Natural Gas

Burner Orifice, LP.

Gas

Pilot Lighting

Thermocouple

Pilot Tnbing Ass3: w/Fittings

\Tent Safety Spill Switch/ VC

Vent Safety Spill Switch/V(R

Wiring Harness w/Bluebird

Wiring Harness wiECO Fitting

Control Rod

Control Rod Grommet

Temperature

Burner,

"VC"

"VCR"

"VCR"

"VCR"

"VCR"

Steel

Control

Burner Mounting

Casing Door

Casing Door Latch

Casing Door Knob

Casin_ Left Side. w/Insulation

Casing Right Side w Insulation

Casing, Back Assembly

Casing, Top Assy. w/Insulation

"VC" Casing Front with/Insulation

"V(" Casing Trim Top & Sides

Casing

"VC" Casing (?enter

Trim w/Clips

"V(R" Bezel Assemblv

Upper

Lower

Casing

Casin_

Cozy Logo Emblem

Valve Support

Lighting

BLOWER

Plate Assy.

Front Panel

Lower

Bracket

Instructions

PARTS

Speed Control Switch w/Knob & Dec

Fan Switch

Fan Switch Bracket

Power Cord

Motor Wirin_ Harness

Knob

Panel

Clips, for Cozy Emblem

Casing Base Assembly

Leg Levellers

Heat Exchanger,

(4 per heater)

Closed

Trim

Trim

Trim with/Insulation

Front

Heat Exchanger, Radiant Front

Heat Exchanger Spacer

Rear Le_. Heat Exchanger

Draft Diverter Assembly

Gnsset

Radiant Glass Panel, "V(R"

Radiant Snpport Rail "VCR" Series

Piezo Ignitor

Piezo Wire

Blowe>Motor

Blower

Blower

Junction

Junction

Hole

Bottom

Front

Upper

Radiant ±br "V(R" Series

Assembly

Gasket - 7-1/4"

Gasket - 4-5/8"

Box Assembly

Box (?over

Blower Nozzle Assembly

Mounting Bracket

Cover

Series

(5 oer htr.)

Blower Platform Assy. (70 only)

NO.

1

1

2

2

3

4

29a

29b

29c

29d

29e

NiA

NiA

30

26

28

28a

28b

28c

33

34

35

36

37

31

32

32

NiA

32A

17

18

19

20

21

13

13

15

16

22

23

24

25

5

5

9

10

11

12

12

38

39

41

NiA

42

43

44

45

46

47

NiA

NiA

48

49

5O

51

NiA

NO.

84090

80088

80063

80062

80110

80024

80025

80027

45332

70096

70012

80103

NiA

80190

NiA

45375

80010

80318

80123

45817

45125

80005

NiA

45102

45112

45150

45050

45070

45073

45074

45077

NiA

NiA

NiA

NiA

NiA

80006

80007

45175

80009

45200

NiA

NiA

NiA

45300

*45195

NiA

NiA

NiA

80016

80127

45860

91267

PRICE

$164.30

$164.30

$22.90

$22.90

$16.40

$2.50

$3.40

$3.40

$1.60

$11.90

$6.60

$10.60

N_

$9.30

N_

$5.90

$1.20

$4.40

$50.70

$12.50

$4.70

$1.20

N_

$23.00

$24.30

$20.10

$50.20

$53.40

$19.10

$9.90

$8.00

NiA

NiA

N_

N_

NiA

$9.30

$2.20

$51.70

$1.50

$126.80

N_

N_

N_

$35.90

$3.00

N_

NiA

N_

$5.70

$3.80

$5.10

$1.90

NO.

84090

80088

80063

80062

80111

80024

80058

80060

45332

70096

70012

80104

80100

NiA

80194

45850

80010

80318

80124

45817

45605

80005

80055

45590

45600

45615

45550

45560

45563

45564

45567

46060

46035

46040

46045

46047

80006

80007

45640

80009

45675

46100

45845

45760

45785

*45195

*80079

80073

*46160

80016

80128

45860

91267

CHB-3

70111

80253

47840

80202

80256

80251

*80257

*80258

47850

47870

47820

47835

47335

PRICE

$164.30

$164.30

$22.90

$22.90

$16.80

$2.50

$3.40

$3.40

$1.60

$11.90

$6.60

$10.60

$10.60

NiA

$10.30

$6.20

$1.20

$4.40

$53.40

$12.50

$6.30

$1.20

$1.60

$28.70

$30.10

$40.10

$61.40

$63.80

$23.60

$t2.00

$9.90

$63.80

$28.40

$25.40

$16.40

$14.90

$9.30

$2.20

$68.90

$1.50

$168.70

$174.20

$1.80

$3.80

$48.30

$3.00

$16.40

$15.20

$4.90

$5.70

$4.00

$5.10

$1.90

BLOWER

$26.70

$7.40

$3.80

$4.20

$3.80

$56.30

$1.20

$1.20

$12.70

$5.10

$13.30

$2.20

$16.40

NO.

84090

80088

80063

80062

80113

80024

80119

80120

45332

70096

70012

80104

80102

NiA

80194

45850

80010

80318

80125

45817

46445

80005

80055

46430

46440

45615

46400

45560

45563

45564

45567

46060

46035

46040

46045

46047

80006

80007

46460

80009

46500

46825

45845

45760

46560

*45195

*80079

80073

*46160

80016

80129

45860

91267

$67.50

$63.80

$23.60

$12.00

$9.90

$63.80

$28.40

$25.40

$16.40

$14.90

$9.30

$2.20

$76.90

$1.50

$222.70

$220.50

$1.80

$3.80

$46.00

$3.00

$16.40

$15.20

$4.90

$5.70

$4.40

$5.10

$1.90

PRICE

$164.30

$164.30

$22.90

$22.90

$17.50

$2.50

$3.40

$3.40

$1.60

$11.90

$6.60

$10.60

$10.60

_A

$10.30

$6.20

$1.20

$4.40

$53.40

$12.50

$7.20

$1.20

$1.60

$31.20

$32.70

$40.10

47100

47110

47113

47114

47117

47610

47585

47590

47595

47596

80006

80007

47180

80009

47200

47700

45845

45760

47295

*45195

*80079

NO.

84090

80088

80063

80062

80112

80024

80169

80167

45332

70096

70012

80099

80099

NiA

80195

47360

80010

80318

80126

45817

46445

80005

80055

47140

47150

47160

80073

*46160

80016

80129

45860

91267

$74.30

$74.30

$30.90

$14.00

$12.00

$69.10

$36.40

$28.90

$1%70

$16.70

$9.30

$2.20

$83.80

$1.50

$270.20

$282.20

$1.80

$3.80

$50.10

$3.00

$16.40

PRICE

$164.30

$164.30

$22.90

$22.90

$17.10

$2.50

$3.40

$3.40

$1.60

$11.90

$6.60

$9.60

$9.60

_A

$10.70

$6.50

$1.20

$4.40

$57.10

$12.50

$7.20

$1.20

$1.60

$38.00

$39.40

$44.30

$15.20

$4.90

$5.70

$4.40

$5.10

$1.90

Page 15

MARCH 2005

Revised 1203

*2 Required

[

IMPORTANT SAFETY BULLETIN ON YOUR GAS CONTROL

SYSTEM FOR HEATING EQUIPMENT

WHAT YOU DON'T KNOW CAN HURT YOU.

AND PILOT LIGHT

Your pilot light system has been designed for safe and reliable operation.

are built-in, the potential for hazard exists.

This information is intended

Although to help safe_" you avoid mechanisms these hazards.

YOUR GAS CONTROL

SYSTEM

AND PILOT LIGHT

Your gas control and pilot light system has a safety device whose purpose l'S to shut-off the gas supply to the appliance if the pilot light goes out.

If you have trouble lighting the pilot or keeping l't lit, it may mean that this safety device is warning you that there is a problem with your system.

Inspection and repairs or replacement must be made by a trained gas service technician.

WHAT TO DO IF YOU SMELL GAS ...

Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately neighbor's instructions.

call your gas supplier from a phone.

Follow the gas supplier's

• If you cannot reach your gas supplier, call the

fire department.

Installation and service must be performed qualified installer, service agency or the gas supplier.

by a

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

CRITICAL SAFETY POINTS TO REMEMBER

TAMPERING IS DANGEROUS

The pilot safety system may also not work if you do not follow the lighting instructions carefully or if you tamper with the gas control that you use to light the pilot.

Tampering with the gas control, particularly mechanism with in the tools, control can and damage can the allow safety gas to leak.

This can result in a fire or explosion causing property damage, personal injury or death.

• Your gas has been odorized so that you can smell it. Always smell around for gas before lighting your appliance.

• Sniff for L.E-gas at floor level.

LP-gas is heavier than floor level.

air and may temporarily exist at

IF YOU SMELL GAS, DON'T LIGHT IT

IF YOU

Association

CAN'T

DON'T

LIGHT

FIGHT gama

IT!

IT,

THIS IS NOT AN ADVERTISEMENT

• If you smell gas, do not attempt to light the pilot.

Do not cause a spark by turning on or off electrical switches or appliances or by using the phone.

Turn offthe gas to the appliances and call your gas supplier from another location.

• If your gas control has gotten wet as the result of flooding or other wetting, it must be replaced immediately by a trained gas service technician.

Water can lead to damage of the internal safety mechanism in the gas control and can create a hazardous condition.

LIINII'iI'III Alll'ii'T

The Louisville Tin & Stove Co. warrants to the original user the accompanying specified herein, provided product said product for the period is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the product.

AS OUTLINED

WARRANTY

CONTINGENT

IN OUR INSTR[

CONSIDERATIONS

CTIONS,

ON INSTALLATION

ANY

ARE

BY A

QUALIFIED

INSTALLATION

INSTALLER

IS NOT

(CONTRACTOR).

RECOMMENDED lAY INWALIDATE YOUR _ARRANTY.

SELF-

AND installation

If within a period of one year from the date of of the product, any part supplied by the manufacturer proves to be defective due to workmanship or material, it will replace such part, provided parts have not been subjected to misuse, alteration, neglect, accidents.

The term of the wan'anty for the heat exchanger or is covered in Table A below.

Any claim not made within ten (10) days after the expiration of the wan'anty period shall be deemed waived by the user.

The manufacturer shall have no liability or be required to perform any obligation under this warranty unless, when requested, the user returns, at the user's expense, the component or product claimed defective, to the manufacturer for inspection, to enable the manufacturer to determine if the claimed defect is covered by this warranty.

No charges for freight, labor or other expenses incurred in the repair, removal, or replacement of any product or component claimed to be defective, will be paid by the manufacturer to the user, and the manufacturer will not be liable for any expenses incurred, by the user, in remedying any defect in the product.

Service under this warranty is the responsibility of the installer.

In the event service under this wan'anty is needed, the user of the product shall request such service directly from the installer.

If the user is unable to locate the installer, the user should write directly to the manufi_cturer, and the name of an alternative service source will be supplied.

The product safety registration card (packed inside the appliance) must be completed and returned to the _actory.

THIS WARRANTY IS EXPRESSLY IN LIEU

OF ANY OTHER WARRANTIES, EXPRESS OR

IMPLIED (WHETHER WRITTEN OR ORAL).

ANY

IMPLIED WARRANTY OF MERCHANTABILITY OR

OF FITNESS FOR A PARTICULAR PURPOSE IS

EXPRESSLY LIMITED TO THE DURATION OF THE

MANUFACTURER'S EXPRESS, WRITTEN

WARRANT'_q

UNDER NO CIRCUMSTANCES SHALL THE

MANUFACTURER BE LIABLE FOR ANY SPECIAL,

INDIRECT OR CONSEQUENTIAL DAMAGES OR

EXPENSES ARISING DIRECTLY OR INDIRECTLY

FROM ANY COMPONENT OR FROM THE USE

THEREOF.

THE REMEDIES SET FORTH HEREIN

SHALL BE THE EXCLUSIVE REMEDIES AVAILABLE

TO THE USER AND ARE IN LIEU OF ALL OTHER

REMEDIES.

SOME

LIMITATIONS

STATES DO NOT ALLOW

ON HOW LONG AN IMPLIED

WARRANTY LASTS, SO THE ABOVE LIMITATIONS

MAY NOT APPLY TO YOU.

SOME STATES DO NOT ALLOW THE

EXCLUSION OR LIMITATION OF INCIDENTAL OR

CONSEQUENTIAL DAMAGES, SO THE ABOVE

LIMITATIONS OR EXCLUSIONS MAY NOT APPLY

TO YOU.

THIS WARRANTY GIVES YOU SPECIFIC

LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER

RIGHTS, WHICH VARY, FROM STATE TO STATE.

Warranty

TABLEA for gas appliance heat exchangers

Product

Cozy Gas Fired Floor Furnace

Cozy Gas Fired Walt Furnace

Cozy Gas Fired Vented Console Heater

Cozy Gas Fired Direct Vent Heater

Cozy Gas Fired Counterflow Furnace

Cozy Gas Fired Counterflow Direct Vent Furnace

Cozy Gas Fired Mobile Home Direct Vent Furnace

Cozy Gas Fired Hi-Efficient Direct Vent Walt Furnace only.

Warranty Period

10 Years

10 Years

10 Years

10 Years

10 Years

10 Years

10 Years

10 Years

LOUISVILLE TIN AND STOVE COMPANY

RO. Box2767 - Louisville, Kentucky40201-2767

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement