STIEBEL ELTRON MINI 2 Operating And Installation Manual


Add to my manuals
12 Pages

advertisement

STIEBEL ELTRON MINI 2 Operating And Installation Manual | Manualzz

Operating and installatiOn Manual

tanKless eleCtriC Water Heater WitH eleCtrO-MeCHaniCal FlOW sWitCH

» Mini™ 2 tanKless eleCtriC Water Heater

» Mini™ 3 tanKless eleCtriC Water Heater

» Mini™ 4 tanKless eleCtriC Water Heater

» Mini™ 6 tanKless eleCtriC Water Heater

The Mini™ series is tested and certified by WQA against NSF/

ANSI 372 for “lead free“ compliance.

STIEBEL ELTRON Inc.

17 West Street | West Hatfield, MA 01088

Tel. 413-247-3380 | Fax 413-247-3369

Email [email protected]

www.stiebel-eltron-usa.com

COntents | OperatiOn

1. General Information ����������������������������� 3

1.1 Symbol key

��������������������������������������

3

2. Safety precautions ������������������������������ 4

3. Register your product ��������������������������� 4

4. Temperature increase above ambient water temperature�������������������������������������� 4

5. Technical drawings ������������������������������ 4

6. Overview ����������������������������������������� 7

6.1 Figure legend

�����������������������������������

7

6.2 General description

����������������������������

7

6.3 Important information before supplying power to unit

�����������������������������������

7

6.4 Hot water output

�������������������������������

8

6.5 Incorrect use

������������������������������������

8

6.6 First steps to be taken in the event of malfunction

�������������������������������������

8

6.7 Maintenance and care

�������������������������

8

7. Operating and installation instructions �������� 9

7.1 Mounting the unit

������������������������������

9

7.2 Plumbing connections

�������������������������

9

7.3 Electrical connection

���������������������������

9

8. Initial start-up ���������������������������������� 10

9. Water heater hand over ������������������������ 10

10. Normal maintenance ��������������������������� 10

11. Technical data ���������������������������������� 11

12. Troubleshooting �������������������������������� 11

13. Spare parts ������������������������������������� 12

14. Warranty ���������������������������������������� 12

2 | Mini™ series tanKless eleCtriC Water Heaters WWW.stiebel-eltrOn-usa.COM

general inFOrMatiOn

general inFOrMatiOn

1. General Information

Read this entire manual. Failure to follow all the guides, instructions and rules could cause personal injury or property damage. Improper installation, adjustment, alteration, service and use of this unit can result in serious injury.

1.1 Symbol key

1.1.1 Layout of safety information

1 2 3

DaNGER Electric shock

Before any work on the appliance, disconnect all poles from the power supply.

4

This unit must be installed by a licensed electrician and plumber. The installation must comply with all national, state and local plumbing and electric codes.

Proper installation is the responsibility of the installer.

Failure to comply with the installation and operating instructions or improper use voids the warranty.

1 Symbol (see 1.1.2 "Symbols")

2 Keyword (see 1.1.3 "Keywords")

3 Designations (see 1.1.2 "Symbols")

4 Information text

1.1.2 Symbols

Save these instructions for future reference. Installer should leave these instructions with the consumer.

symbol description

Injury

If you have any questions regarding the installation, use or operation of this water heater, or if you need any additional installation manuals, please call our technical service line at 800-582-8423 (USA and

Canada only). If you are calling from outside the

USA or Canada, please call USA 413-247-3380 and we will refer you to a qualified Stiebel Eltron service representative in your area.

!

Electrocution

Burns or scalding

Other situations

!

This is The safeTy alerT symbol. iT is used

To alerT you To poTenTial personal injury hazard. obey all safeTy messages ThaT follow

This symbol To avoid possible injury or deaTh.

The chapter Operation is intended for homeowners, heating contractors, plumbers and electricians.

The chapter Installation is intended for heating contractors, plumbers and electricians only.

1.1.3 Keywords

KeYWOrd

DANGER

WARNING

CAUTION

The keyword DANGER indicates information that must be observed, otherwise serious injury or death will result.

The keyword WARNING indicates information that must be observed, otherwise serious injury or death may result.

The keyword CAUTION indicates information that must be observed, otherwise relatively serious or light injuries may result.

WWW.stiebel-eltrOn-usa.COM Mini™ series tanKless eleCtriC Water Heaters | 3

OperatiOn

general inFOrMatiOn

saFetY preCautiOns

2. Safety precautions

!

please read and follow These insTrucTions. failure To follow These insTrucTions could resulT in serious bodily injury or deaTh.

The uniT musT be insTalled by a licensed elecTrician and plumber. The insTallaTion musT comply wiTh all naTional, sTaTe and local plumbing and elecTric codes.

service of The uniT musT be performed by qualified service Technicians.

before proceeding wiTh any insTallaTion, adjusTmenT, alTeraTion, or service of This uniT all circuiT breakers and disconnecT swiTches servicing The uniT musT be Turned off. failure To do so could resulT in serious personal injury or deaTh.

danger: never remove The uniT's cover unless The elecTriciTy servicing The uniT is Turned off. failure To do so could resulT in personal injury or deaTh.

warning: The uniT musT be properly grounded. failure To elecTrically ground The producT could resulT in serious personal injury or deaTh.

DaNGER: waTer TemperaTures over

125°f can cause severe burns insTanTly or deaTh from scalding. a hoT waTer scalding poTenTial exisTs if The ThermosTaT on The uniT is seT Too high. households wiTh small children, disabled or elderly persons may require ThaT The ThermosTaT be seT aT

120°f or lower To prevenT possible injury from hoT waTer.

3. Register your product

you musT regisTer This producT wiThin

90 days of purchase on our web siTe in order To acTivaTe The sTandard warranTy or

To be eligible for The exTended warranTy. go

To our web siTe aT WWW.STIEBEL-ELTRON-uSa.cOm

and click on regisTer your producT.

Before beginning the registration process, we suggest that you gather the necessary information which will be as follows:

Type, example: Mini 3 (from the white label that is on the right side of the unit) number listed after "nr." place of purchase purchase date first & last name email address physical address phone number if you have any quesTions concerning The regisTraTion process or warranTy opTions, please conTacT sTiebel elTron usa direcTly aT

(800)-582-8423.

Limited liability warranty:

Stiebel Eltron, Inc. is not liable for damages to the unit, damage to personal property, bodily injury, or loss of life due to the following conditions:

- Non-observance of these instructions

- Incorrect use (heating any other liquid than water)

- Installation of the appliance by unqualified personnel

- Unauthorized modifications

- Technical modifications

- Use of unauthorized spare parts

THE THREE YEaR WaRRaNTY cOVERS aLL PaRTS

BuT DOES NOT cOVER DamaGE TO THE uNIT DuE TO

HaRD WaTER (FOR THE cOmPLETE WaRRaNTY SEE

"Warranty", SEcTION 14 PG. 12). IF YOu KNOW OR

SuSPEcT THaT THE WaTER IN YOuR aREa IS HaRD

(HaS a HIGH mINERaL cONTENT), IT IS NEcESSaRY

TO INSTaLL a WaTER SOFTENING DEVIcE TO aVOID

DamaGE TO THE mINI™ uNIT.

4 | Mini™ series tanKless eleCtriC Water Heaters WWW.stiebel-eltrOn-usa.COM

general inFOrMatiOn

teMperature inCrease abOve aMbient Water teMperature

4. Temperature increase above ambient water temperature

[ °F ] type kW gpM

0.32 0.42 0.48 0.5 0.69 0.85 1.06 1.14

mini™ 2 1.8 38 - - - – – – – mini™ 3 3.0 65 49 43 41 30 – – –

mini™ 4

mini™ 6

3.5 75 56 50 45 35 – – –

5.7 – – – – – 46 37 34

Min. water flow to activate unit.

[ °c ] type kW l/min

1.2 1.6 1.8 2.0 2.6 3.2 4.0 4.3

mini™ 2 1.8 22 16 14 13 – – – – mini™ 3 3.0 36 27 24 22 17 – – –

mini™ 4 3.5 42 31 28 25 19 – – –

mini™ 6 5.7 – – – – – 26 20 19

Min. water flow to activate unit.

5. Technical drawings

a

7 ½ ” (190 mm) 3 ¼ ” (82 mm)

4

1 1 /

16

” (30 mm)

2

4 ¾ ” (120 mm)

3

WWW.stiebel-eltrOn-usa.COM

9/16”-24 UNEF

13 /

16

” (20 mm)

Mini™ series tanKless eleCtriC Water Heaters | 5

general inFOrMatiOn

teCHniCal draWings

B c

5

9

10

8

7

6

D

V > p >

L N

Mini™ 2/3

Mini™ 4/6

L N GRD

L L GRD

6 | Mini™ series tanKless eleCtriC Water Heaters WWW.stiebel-eltrOn-usa.COM

OperatiOn

OvervieW

This manual musT be read carefully before aTTempTing To insTall The mini™ waTer heaTer. if you do noT follow The safeTy rules or The insTrucTions ouTlined in This manual, The uniT may noT operaTe properly and iT could cause properTy damage, serious bodily injury and/ or deaTh.

sTiebel elTron, inc. will noT be liable for any damages because of failure To comply wiTh The insTallaTion and operaTing insTrucTions ouTlined in This manual or because of improper use. improper use includes The use of This appliance To heaT any liquid oTher Than waTer. failure

To comply wiTh The insTallaTion and operaTing insTrucTions or improper use voids warranTy. never remove The uniT’s cover unless The elecTriciTy is Turned off.

if you have any quesTions regarding The insTallaTion or operaTion of This waTer heaTer, or if you need any addiTional insTallaTion manuals, please call our Technical service line on

800-582-8423 (usa and canada only). if you are calling from ouTside The u.s. or canada, please call usa 413-247-3380 and we will refer you To a qualified sTiebel elTron service represenTaTive in your area.

6. Overview

6.1 Figure legend

1 Hot water connection

2 Cold water connection with filter screen

3 Filter screen

4 Mounting holes

5 Electrical junction box

6 Water supply line for faucet installation

7 Sink

8 Cold valve (right)

9 Hot valve (left)

10 Shut off valve

11 Reset button from safety pressure cut out

6.2 General Description

The Mini™ tankless water heater differs from conventional storage type water heaters in several ways. It does not store hot water. Instead, water is heated instantaneously as it flows through the unit. The powerful heating elements are activated by a flow switch as water is drawn from a hot water faucet connected to the Mini™. Due to the absence of stand-by losses, the Mini™ offers greater energy efficiency than storage type water heaters. The unit will continuously supply hot water as long as the faucet is open

The temperature of the hot water delivered by the Mini™ depends on the wattage of the heating element, the temperature of the incoming cold water, and the water flow rate through the unit. In order for the Mini™ to operate properly, it must be carefully matched to the application.

In case you have questions regarding the way you plan to use the Mini™, please call our technical service line at 800-582-8423 (USA and Canada). For service outside the U.S. and Canada, please call us at

USA 413-247-3380. You can also e-mail us at info@ stiebel-eltron-usa.com or fax us at 413-247-3369.

The Mini™ can be used for hand washing type applications in the U.S. and Canada:

– Restroom sinks in commercial/industrial facilities

and homes

– Kitchen areas in commercial /industrial facilities

and homes

– Cabins

– Special uses in photo developing shops,

laboratories etc.

The Mini™ can also be used for whole apartments and homes in warm climate zones such as the

Caribbean region, Central America and Mexico due to the higher ambient water temperatures.

WWW.stiebel-eltrOn-usa.COM Mini™ series tanKless eleCtriC Water Heaters | 7

OperatiOn

OvervieW

6.3 Important information before supplying power to unit

air in the cold water pipe will destroy the bare-wire heating system of the mini™. if the water supply to the mini™ has been interrupted, for example due to the risk of frost or work on the water pipe, the following steps must be carried out before the unit is used again.

» 1. Turn off circuit breaker.

» 2. Open a hot water tap downstream of the unit for as long as is necessary for the unit and the cold water pipe to be free of air.

» 3. Turn on circuit breaker.

All information in these Instructions for Use and

Installation must be followed carefully. They provide important information with regard to safety, operation, installation, and maintenance of the device.

6.4 Hot water output

Model

Mini™ 2*

Mini™ 3

Mini™ 4

Mini™ 6

Wattage typical hot water output

1.8 kW

3.0 kW

0.32 GPM

0.5 GPM

3.8 kW

6.2 kW

0.5 GPM

1.0 GPM

*Note: Mini™ 2 is internally restricted to 0.32 GPM

6.5 Incorrect use

The following are not permitted and will void the factory warranty:

- Installation of the appliance where it is at risk from frost

- Installation in rooms where the appliance is at risk from explosions as a result of dust, gases or vapors

- Ignoring safety clearances and safety zones

- Incorrect power connection

- Operation of the appliance without water flowing through the unit, or with air in the lines (see "Initial startup", section 8, pg. 10)

- Operation of the unit with the cover off

- Heating liquids other than potable water

6.6 First steps to be taken in the event of malfunction

warning: always shuT off power and waTer To The uniT prior To removing The filTer screen. failure To do so may cause serious bodily injury or deaTh.

» Check the circuit breaker

» Check the filter screen for scale blockage or dirt accumulation. See also ”Troubleshooting” section

10 pg. 11.

6.7 maintenance and care

!

mainTenance work, such as checking elecTrical safeTy, may only be carried ouT by a qualified insTaller. warning: always shuT off power and waTer To The uniT prior To removing

The filTer screen. failure To do so may cause serious bodily injury or deaTh.

Regularly clean and descale the filter screen located in the cold water inlet connection and if necessary replace.

Always shut off power and water to the unit prior to removing the filter screen.

A damp cloth is sufficient for cleaning of the unit's housing. Do not use any abrasive or corrosive cleaning agents.

8 | Mini™ series tanKless eleCtriC Water Heaters WWW.stiebel-eltrOn-usa.COM

installatiOn

Operating and installatiOn instruCtiOns

7. Operating and installation instructions

keep These insTrucTions carefully and pass Them on To your successor in The evenT of a change in ownership, in The evenT of mainTenance and possible repair work They should be passed To The qualified insTaller for his or her reference.

7.1 mounting the unit

!

uniT musT be insTalled wiTh The plumbing connecTions poinTing downward or upward only.

warning: do noT insTall uniT where iT would rouTinely be splashed wiTh waTer. elecTric shock or deaTh may resulT.

» 1. Install Mini™ as close as possible to the hot water draw-off point, for example, directly underneath the sink or next to the shower stall.

» 2. Install Mini™ in a frost free area. If frost may occur, remove unit before freezing temperatures set in.

» 3. leave a minimum of 5" of clearance on all sides for servicing.

» 4. Remove plastic cover by removing screws located on the left and right sides of the unit

B

.

» 5. Remove plastic backplate by pulling on the tab with a screwdriver

B

.

» 6. Mount backplate securely to wall by putting two screws through mounting holes a B

.

» 7. Snap unit back onto mounting plate

B

.

» 8. Reinstall cover with screws on left and right side of unit

B

.

7.2 Plumbing connections

noTe: if soldering near The uniT is necessary, please direcT The flame away from The housing of The uniT in order To avoid damage. excessive heaT from soldering on cop per pipes near The mini™ may cause damage.

all plumbing work musT comply wiTh naTional and applicable sTaTe and local plumbing codes.

» 1. All plumbing work must comply with national and applicable state and local plumbing codes.

» 2. A pressure reducing valve must be installed if the cold water supply pressure exceeds 150 PSI (10 bar).

» 3. Make certain that the cold water supply line has been flushed to remove any scale and dirt.

» 4. Install isolating valve in cold water line as shown in illustration c

. This allows the unit to be isolated for maintenance purposes.

» 5. Cold water connection (inlet) is on the right side of the unit, hot water connection (outlet) is on the left side of unit.

» 6. Tankless water heaters such as the Mini™ are not required to be equipped with a Pressure and

Temperature Relief Valve (except in Massachusetts).

If the local inspector will not pass the installation without a P+T valve, it should be installed on the hot water outlet side of unit.

» 7. The Mini™ is designed for connection to a braided stainless steel hose with a 3/8“ OD Tube

Outlet.

» 8. When all plumbing work is completed, check for leaks and take corrective action before proceeding.

7.3 Electrical connection

warning: before beginning any work on The elecTric insTallaTion, be sure

ThaT The main circuiT breaker panel swiTch is

"off" To avoid any danger of elecTric shock. failure To do so may resulT in serious injury or deaTh. all mounTing and plumbing musT be compleTed before proceeding wiTh elecTrical hook-up. where required by local, sTaTe or naTional elecTrical codes, The circuiT should be equipped wiTh a ground faulT inTerrupTer.

warning: as wiTh any elecTric appliance, failure To elecTrically ground uniT may resulT in serious injury or deaTh.

cauTion: insTalling a mini™ 2 or mini™ 3 on a 208v or 220 - 240v circuiT will desTroy The heaTing elemenT. This is considered improper insTallaTion and will void your facTory warranTy.

Voltage

Mini™ 2: 110 - 120V

Mini™ 3: 110 - 120V

Mini™ 4: 208, 220 - 240V

Mini™ 6: 208, 220 - 240V

WWW.stiebel-eltrOn-usa.COM Mini™ series tanKless eleCtriC Water Heaters | 9

installatiOn

initial start-up

on

7.3 Electrical connection (cont.)

1. All electrical work must comply with national and applicable state and local electrical codes.

2. The Mini™ should be connected to a properly grounded dedicated branch circuit of proper voltage rating. In installa tions with several Mini™ units, each unit requires an independent circuit. Please refer to the technical data table for the correct wire and circuit breaker size.

3. The open ends of the "pigtail" must be feed into an press relief clamp and tighten clamp down on wire.

4. Reinstall plastic cover.

8. Initial start-up

10. Normal maintenance

!

cauTion: oTher Than The filTer screen,

The mini™ does noT conTain any parTs serviceable by The lay person. in case of malfuncTion please conTacT a licensed plumber or elecTrician.

STIEBEl ElTRON Mini™ tankless heaters are designed for a very long service life. Actual life expectancy will vary with water quality and use. The unit itself does not require any regular maintenance. However, to ensure consistent water flow, it is recommended to periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head. Also, the Mini™ has a built in filter screen that should be cleaned from time to time. In order to do this, turn off the cold water supply at the isolating valve. Clean screen and put the screen back into its original position.

!

warning: open hoT waTer fauceT for a few minuTes unTil waTer flow is conTinuous and all air is purged from waTer pipes. The uniT’s plasTic cover musT be insTalled before

The circuiT breaker is Turned on.

1 electronic

°C on

°C

2 on

9. Water heater hand over

press 2.

familiarize him or her with its use.

°C °C

Important instructions:

» Draw the user’s attention to possible hazards

(scalding).

electronic electronic

» Hand over these instructions for future reference.

» In order to obtain a proper temperature at a single spout mixer-type faucet, restrict cold water flow to faucet by partially closing the cold water shut-off valve under the sink until cold water and hot water flow rates are approximately the same.

°C electronic

°C

10 | Mini™ series tanKless eleCtriC Water Heaters on

WWW.stiebel-eltrOn-usa.COM

1.

electronic

°C electronic

°C

2.

installatiOn

teCHniCal data

11. Technical data

Model

Item number

Phase

Voltage

Wattage

Max. amp, load

Min. required circuit breaker size

Required wire size

Min. water flow to activate unit

Recommended inlet temperature range

Nominal water volume

Working pressure, max.

Tested to pressure

Weight

Dimensions height depth width

Water connections

Heating system

AWG COPPER

A

≥ GPM ( ≥ l/min)

V kW

A

Mini ™ 2 * Mini ™ 3

231045 220816

1 1

115-125

1.8

15

115-125

3.0

25

20

12

0.21 (0.8)

30

10

0.40 (1.5)

°F (°C)

GAl (l)

PSI (bar)

PSI (bar) lbs. (kg) inch (mm) inch (mm) inch (mm)

* note: mini™ 2 is internally restricted to 0.32 gpm

– Tankless water heaters are considered a non-continuous load

– conductors should be sized to maintain a voltage drop of less than 3 % under load

12. Troubleshooting

E

Mini ™ 4

222039

1

208 220-240

3.2

3.5

13.8

15.2

20

12

20

12

0.40 (1.5)

6 1 /

2

(165)

3 1 /

4

(82)

7 1 /

2

(190) for 3/8“ O.D. flex connector

Bare-wire symptom possible cause

No hot water despite fully opened hot water faucet.

No electrical power.

The activation flow rate needed to turn on the heating element has not been reached.

Safety cut out tripped solution

Check the circuit breaker and check voltage at the wiring block.

Clean filter screen.

– turn circuit breakers off

– open Hot Valve to release pressure from the unit

– reset saftey pressure cut out

E

– turn circuit breakers on

Mini ™ 6

220817

1

208 220-240

4.7

5.7

22.4

24.7

30

10

0.77 (2.9)

41-77 (5-25)

0.026 (0.1)

30

10

150 (10)

300 (20)

3.44 (1.56)

WWW.stiebel-eltrOn-usa.COM Mini™ series tanKless eleCtriC Water Heaters | 11

WarrantY | envirOnMent and reCYCling

13. spare parts

Mini ™ Tankless Spare Parts List & Diagram

Spare Part No.

Model Mini

3

1 Front cover

2 Rear housing

3 Filter screen

4 Plumbing connection (incl. 2 O-rings)

271013

271012

275981

272757

Mini

4 no.

Model spare part

1 Front cover

2 Rear housing

3 Filter screen

4 Plumbing connection

5 O-rings

Mini™ 2

Mini™ 3

Mini™ 4

Mini™ 6

271010

271011

272884

272777

083043

Mini

6

1

2 4

3

14. warranty

RESIDENTIAl & COMMERCIAl WARRANTY: STIEBEl ElTRON WARRANTS TO THE ORIGINAl OWNER THAT THE MINI™ TANKlESS ElEC-

TRIC WATER HEATER WIll BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAlS FOR A PERIOD OF THREE YEARS FROM THE

DATE OF PURCHASE. SHOUlD THE PART(S) PROVE TO BE DEFECTIVE UNDER NORMAl USE DURING THIS PERIOD, STIEBEl ElTRON,

INC. WIll BE RESPONSIBlE FOR REPlACEMENT OF THE DETECTIVE PART(S) ONlY. STIEBEl ElTRON, INC. IS NOT RESPONSIBlE FOR lABOR CHARGES TO REMOVE AND/OR REPlACE THE DEFECTIVE PART(S), OR ANY INCIDENTIAl OR CONSEQUENTIAl EXPENSES.

SHOUlD THE OWNER WISH TO RETURN THE TANKlESS ElECTRIC WATER HEATER FOR REPAIR, THE OWNER MUST FIRST SECURE

WRITTEN AUTHORIZATION FROM STIEBEl ElTRON, INC. THE OWNER SHAll BE REQUIRED TO SHOW PROOF OF PURCHASE DATE,

AND TO PAY All TRANSPORTATION COSTS TO RETURN THE DEFECTIVE PART(S) OR TANKlESS ElECTRIC WATER HEATER FOR REPAIR

OR REPlACEMENT. WARRANTY IS VOID IF WATER HEATER HAS BEEN INSTAllED OR USED IMPROPERlY OR IF DESIGN HAS BEEN

AlTERED IN ANY WAY.

STIEBEL ELTRON, INc.

17 West Street

West Hatfield, ma 01088, uSa

PHONE: 800-582-8423 or 413-247-3380

FAX: 413-247-3369

E-Mail [email protected]

www.stiebel-eltron-usa.com

Environment and recycling

Please help us protect the environment. Dispose of the appliance and its packaging in accordance with national regulations.

12 | Mini™ series tanKless eleCtriC Water Heaters

STIEBEL ELTRON, INc.

17 West Street

West Hatfield, ma 01088, uSa

PHONE: 800-582-8423 or 413-247-3380

FAX: 413-247-3369

E-Mail [email protected]

www.stiebel-eltron-usa.com

WWW.stiebel-eltrOn-usa.COM

WarrantY envirOnMent and reCYCling

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals