NLC-100 User Manual


Add to my manuals
180 Pages

advertisement

NLC-100 User Manual | Manualzz

be reproduced, stored in a retrieval system, or transmitted in any form or  by any means electronic, mechanical, photocopying, recording or  otherwise without the prior permission of the publisher.

Netafim USA

5470 E. Home Ave.

Fresno, CA  93727

Phone: (888) 638‐2346

Fax: 

Email:

(559) 453‐6800

(559) 453‐6803 [email protected]

NLC-100S

NLC-100D

1

NLC‐100 User Manual 

2

Copyright January 2014. All rights reserved. No part of this publication may  be reproduced, stored in a retrieval system, or transmitted in any form or  by any means electronic, mechanical, photocopying, recording or  otherwise without the prior permission of the publisher.

Netafim USA

5470 E. Home Ave.

Fresno, CA  93727

Phone: (888) 638‐2346

Fax: 

Email:

(559) 453‐6800

(559) 453‐6803 [email protected]

450‐230‐0003/A

NLC‐100 User Manual

Table of Contents

Chapter 1: Introducing NLC‐100 ..............................................................................................  9

The Controller  .......................................................................................... 9

Irrigation Features  .................................................................................... 9

Chapter 2: Operating the controller ......................................................................................  11

The Display ............................................................................................. 11

A standard display when idling in Auto mode ...................................12

Button and Controls  ...................................................................................... 13

The Seven Main Modes  .......................................................................... 13

OFF (Red)  ............................................................................................... 14

MANUAL (Brown)  ................................................................................... 14

AUTO (Grey)  ........................................................................................... 14

PROGRAM (Light blue)  ........................................................................... 15

SETUP (Dark blue)  .................................................................................. 15

ADVANCED (Black) .................................................................................. 15

SOLENOID AMPS (Light green) ................................................................ 15

Chapter 3: Programming the NLC ..........................................................................................  17

Basic Controller Configuration ................................................................ 17

Setting the date and time ....................................................................... 17

Configuring Irrigation Programs  ............................................................. 18

Configuring the stations ................................................................................ 20

Configuring a station in a program  ................................................................ 21

Setting Water Days ........................................................................................ 25

Selecting the water days  ........................................................................ 27

Setting Start Times  ................................................................................. 28

Adjusting Water Usage (Water Budget or ET)  ................................................ 31

Adjusting the ET (Water budget)  ............................................................ 35

Activating/deactivating a Program  ......................................................... 37

3

4

NLC‐100 User Manual

Adding a Booster Pump  .......................................................................... 39

Adding a Master Valve (Supply Pump)  .................................................... 41

Testing a Program  ................................................................................... 41

Chapter 4: Running the NLC...................................................................................................  43

Running NLC in Auto Mode  .................................................................... 43

Pausing a Running Program  .................................................................... 45

Resuming a paused program  .................................................................. 46

Running Extra Stations in Auto Mode  ..................................................... 47

Running a station manually  .................................................................... 47

Running Extra Programs in Auto Mode ................................................... 49

Running NLC in Manual Mode  ................................................................ 51

Alarms  .......................................................................................................... 53

Becoming aware of alarms on‐site  ......................................................... 53

Receiving alarm notifications on email  ................................................... 55

Viewing the alarm list ............................................................................. 59

Alarms in the NLC  ..............................................................................60

Monitor Data  ................................................................................................ 64

Rain Shutdown .............................................................................................. 67

Chapter 5: Advanced Features...............................................................................................  69

Intelliset ........................................................................................................ 69

FloGuard  ....................................................................................................... 70

FloStack  ........................................................................................................ 70

Feature Manager  .......................................................................................... 70

Appendix A: How Amount Based Rain Alarms Work ..............................................................73

Example A.1  .......................................................................................73

Example A.2.  ......................................................................................75

Example A.3.  ......................................................................................76

Configuring the Extended Rain Shutdown Feature  ........................................ 77

Examples using Different Parameters  ..................................................... 81

NLC‐100 User Manual

Example A.4.  ......................................................................................81

Example A.5  .......................................................................................82

Example A.6  .......................................................................................83

Example A.7  .......................................................................................84

Appendix B: Adding an ET Device ...........................................................................................87

How ET Works with the NLC  ................................................................... 87

Example B.1. ET calculation with rain shortage .................................88

Example B.2. ET calculation with excess rain  ....................................88

Example B.3. Calculating ET run time  ................................................90

Example B.4. How minimum ET value works  ....................................91

Examples ............................................................................................92

Example B.5. All parameters in use  ...................................................92

Numbers  ............................................................................................93

Table Explanation  ..............................................................................94

Example B.6. No Min ET  ....................................................................95

Numbers  ............................................................................................96

Table Explanation  ..............................................................................96

Example B.7. No Max ET ....................................................................97

Numbers  ............................................................................................98

Explanation ........................................................................................99

Example B.8. No soil holding  .............................................................99

Numbers  ..........................................................................................100

Example B.9. Max. hourly rain .........................................................102

Options for Getting ET Data  ........................................................................ 102

Using Historical ET Data  .............................................................................. 103

Configuring for Historical ET Data ......................................................... 104

Appendix C: Adding a flow sensor ........................................................................................109

Alarm Types  .....................................................................................109

Setting Alarm Thresholds  ..................................................................... 110

5

6

NLC‐100 User Manual

Setting the alarm reaction delay  .......................................................... 110

Setting the high flow threshold  ............................................................ 112

Setting the Flow Deviation  ................................................................... 114

Setting the unscheduled flow threshold  ............................................... 116

Setting the master pump failure threshold  ........................................... 118

Setting Alarm Actions  ........................................................................... 120

Configuring alarm action for MPF ......................................................... 120

Setting Expected Station Flow  .............................................................. 121

Entering expected flow for a station ..................................................... 121

Running the "learn flow" feature .......................................................... 123

Viewing the Current Flow  ........................................................................... 124

Inspecting and Toggling Station Status  ........................................................ 126

Managing station status  ....................................................................... 127

Appendix D: Moisture sensors ..............................................................................................129

The Role of Moisture Sensors ...................................................................... 129

Calculate  .............................................................................................. 130

Communicate  ....................................................................................... 130

Validate  ................................................................................................ 131

How irrigation is adjusted by moisture sensors  .................................... 132

How moisture sensor input affects ET  .................................................. 135

Abbreviations  ..................................................................................135

VSM ranges for the different soil types ...........................................136

Example D.1. Dry start condition (stress point) ...............................137

Example D.2. Optimal start condition  .............................................140

Example D.3.Wet start condition (field capacity) ............................143

Appendix E: Changing Station Run Sequence and Mapping .................................................151

Example E.1. Putting a new station in the middle of the run chain  151

Changing the station run sequence .................................................152

Resetting station run sequences ........................................................... 153

NLC‐100 User Manual

Changing Station Output Mapping  .............................................................. 155

Changing Station Output Mapping ..................................................155

Resetting Station Output Mapping ..................................................156

Appendix F: Using Simple Flow Management.......................................................................159

Configuring for Flow Management .............................................................. 159

How the Flow Management Works  ............................................................. 159

Setting the System Flow Capacity ................................................................ 160

Appendix G: Defining a custom irrigation period..................................................................163

Example G.1. Skewed days with custom irrigation periods  ................... 163

Configuring the Irrigation Period  .......................................................... 165

Appendix H: Advanced irrigation: Misting, Cycle and Soak ..................................................167

How is This Different from Regular Programs?  ............................................ 167

When the NLC Alters Your Program  ...................................................... 168

How to Configure for Misting or Cycle & Soak ............................................. 169

Full misting program example  .........................................................169

Enabling Misting ................................................................................... 170

Setting the Start Times With Count and End Time  ................................ 172

Things to Keep in Mind  ............................................................................... 175

Glossary  ........................................................................................................... 177

7

8

NLC‐100 User Manual

NLC‐100 User Manual 

Chapter 1: Introducing NLC‐100

The NLC is a microprocessor based irrigation control system. A central  controller and up to 100 field stations comprise a complete system. In  addition the controller will accept input from several external sensors in  order to adjust its irrigation to the local weather conditions.

The Controller

The heart of a NLC based system is the controller. This is a microprocessor  controlled device that stores your irrigation programs and NLC individual  stations in the field when to activate their valve(s).

Irrigation Features

Here are the main features that the NLC utilizes to help you automate your  irrigation:

• Controls up to 100 solenoids (specifications vary depending on  model) attached to valves or relays via the built‐in connection board  and three expansion boards.

• Provides ET corrected irrigation for optimal adjusted water  consumption.

• Measures water flow and raises alarms or halts irrigation on  unexpected flow.

• Allows for 10 independent irrigation programs. In addition there is  a fixed test program that activates all 100 stations in turn.

• A program can activate up to 100 stations in named order.

• Each station can run for up to 17:59:50 (In fact, you can boost this 

even further by increasing the "water budget". For more  information turn to Adjusting the ET (Water budget) on page 35.

• Each program can activate a one or more booster pumps in addition  to the stations.

9

10

NLC‐100 User Manual 

• Master valves and booster pumps will be activated in parallel in all  connection and expansion boards (specifications vary depending on  model).

• All programs have 12 start times per day.

• All programs can run simultaneously.

• You configure each program to run on any selection of days in a 14  day period, or on odd/even dates.

• You can activate one or more valves or programs manually while  one or more programs are running, up to a total of 12  simultaneously running valves.

• A master valve can be selected that will open when any program or  station is run.You typically assign master valve status to the valve  controlling access to municipal water or pumping station.

• Up to 10 moisture sensors that can monitor soil moisture and adjust  irrigation accordingly.

NLC‐100 User Manual 

Chapter 2: Operating the controller

It is essential that you feel comfortable with the interface of the NLC before  you start configuring stations, irrigation programs etc.

This section explains what all the controls are for in the different modes. 

For more information turn to Chapter 3: Programming the NLC on page 17 

and Running the NLC on page 43.

PROGRAM STATION

PAUSE/

RESUME

STOP

MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

NLC-100S

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

CANCEL

NO

ENTER

YES

HELP

?

The Display

The NLC has a back lit LCD display with two rows of 40 characters. Since the  limit is 40 characters per row, sometimes words are abbreviated, but all  messages should still be easy to understand ‐ if in doubt about a message,  consult this manual.

A typical message is the following that is displayed when the NLC is idle,  waiting for the next program to run:

11

NLC‐100 User Manual 

A standard display when idling in Auto mode

This simply states that the next program to run is program number one, the  program's total run time is 40 minutes, and it will run on Tuesday at 09:44 

PM, activating two stations in turn. In the top right you see the current  time.

You will learn all about programs in For more information turn to Chapter 

3: Configuring Irrigation Programs on page 18.

12

Button and Controls

NLC‐100 User Manual 

PROGRAM STATION

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

NLC-100S

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

CANCEL

NO

ENTER

YES

HELP

?

Jog wheel

Item selector

The NLC is handled by the dial and item selectors in conjunction. Select the  mode using the dial, scroll through dialogs using the item selectors and  confirm or cancel your selections using the 

YES and 

CANCEL buttons.

The Seven Main Modes

The NLC works in seven different modes, each allowing you to handle a  subset of the controller functionality.

Each main mode has its own color on the front plate (provided in  parenthesis after each mode name)

13

NLC‐100 User Manual 

OFF (Red)

This is short for "Irrigation Off" ‐ practically this means that the connection  to the controller is shut down and no programs will be run. The display will  still be lit and you'll see this message:

Idling in Irr. Off mode

This is also where you can manually turn irrigation off when it’s raining.

MANUAL (Brown)

In manual mode you can start a program or a single station manually.

AUTO (Grey)

AUTO is the normal operating position and is probably where your system  will spend the most of it's time. When in auto mode the NLC makes sure  that all programs are run according to schedule. Once everything is  configured, you switch the system to auto mode and leave it to do its job.

You also have the option of starting additional valves or programs manually  while a program is running in auto mode. This can be useful if you notice  that an area needs a little extra watering but you don't want to create a  new program to take care of it ‐ just turn on the nearest valve for a few  minutes.

14

NLC‐100 User Manual 

PROGRAM (Light blue)

This is the mode you switch to when creating programs. For more  information turn to Chapter 3: Configuring Irrigation Programs on page 18.

SETUP (Dark blue)

This mode lets you configure the controller for various sensor inputs, view  alarms and rain event status.

ADVANCED (Black)

In advanced mode you can configure a lot of settings that you don't have  to change in the daily work with the controller:

• FloStack ‐ plan and control system flow

• FloGuard ‐ monitor the controller for potential problems

• Intelliset ‐ manage ET devices, moisture sensors and related  operations

• Define a custom irrigation period

• Assign booster pumps to programs

• Manage the run sequence and mapping of your stations

• Enable/disable whether or not to display the line

• Feature manager ‐ enable/disable features only used by a subset of  users, like misting and "cycle & soak" irrigation

• Erase the entire controller's data ‐ in case you're setting up a new  system from scratch

SOLENOID AMPS (Light green)

In this mode you can test each valve in the field individually.

15

16

NLC‐100 User Manual 

(MORE: 2‐wire short finding + decoder programming install/trouble for D)

NLC‐100 User Manual 

Chapter 3: Programming the NLC

Like conventional controllers, the NLC must be programmed to control  your irrigation. The controller itself needs to be configured with basics like  date and time, and in addition, the stations need to be configured and  tested. Finally, you need to create your irrigation programs, and possibly  configure the system for sensor inputs.

All of this happens at the controller, and this chapter walks you through all  the tasks.

Basic Controller Configuration

The controller will remember date/time for up to two weeks when not  connected to a power outlet. Most likely it will have lost this information  when you first receive it, so the very first thing you have to do to get going  is to set the date and time:

Setting the date and time

1 Turn the dial to the 

SET DATE & TIME position

PAUSE/

RESUME

STOP

MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

17

NLC‐100 User Manual 

Now the display looks something like this:

2 You change the settings with the up and down item selectors and  move between the day, month and year slots with the left and right 

item selectors.

Push the

ENTER button to save your setting - now the controller will save the date.

Note: 

The week day will be calculated automatically from the  date you choose.

Important! 

Daylight savings are not handled automatically.

Configuring Irrigation Programs

The NLC holds 10 programs that can each activate 100 stations in turn. Each  program can run 12 times a day on odd, even or selected days in a two  week period. Additionally, each program can activate a booster pump and  a master valve throughout the duration of the program.

18

NLC‐100 User Manual 

There is also a test program which can not be modified. This program is  primarily used to troubleshoot the system. 

To start configuring a program, turn the dial to 

PROGRAM

.

Important! 

Throughout this section we assume that you have  turned the dial to the PROGRAM position ‐ you then use the  item selectors to choose the program you wish to edit, and then  move the dial along to the aspect of the program you wish to  edit (run time, water days, start times etc.). When working this  way you will see both the 

PROGRAM and e.g. 

WATER DAYS

Turn to 

PROGRAM mode.

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

19

NLC‐100 User Manual 

Now the NLC shows you the configuration for "Program 1". The first time  you do this, most settings are blank, and the display will look like this:

Program / Name  selector

Water days Total run time Active/Passive

Number of  stations in  program

Number of run  times

First start time Water budget

The following sections walk you through everything you need to know in  order to customize the 10 programs.

Configuring the stations

Each of the 10 programs can activate up to 100 stations in turn. The  stations are run in turn according to their IDs, starting from ST01, ST02  etc

1

. To configure a program, simply set the run times of each station to the  number of minutes you wish it to run. 

Here's an example of an irrigation program:

1.

1

If you want the stations to run in a different order than this, you must assign sequence numbers to each station and the sequence number will determine the order instead.

20

NLC‐100 User Manual 

...

...

ST01

ST02

ST04

ST16

Station Run Time

...

...

10 min

5 min

50 min

10 min

Note: 

A station can appear in as many programs as you wish,  but obviously only one program can run a station at a time.

If two programs wish to run the same station at the same time, the station  will simply keep running until the last program no longer needs it running.

Now let's look at how you configure the individual stations in a program.

Configuring a station in a program

1 Turn the dial to 

PROGRAM

.

21

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display will look something like this:

22

2 Use the item selectors to scroll to the program you wish to configure  a station for.

3 Now turn the dial to the 

RUN TIME position. Say you selected  program 2 ‐ then the display will look like this:

NLC‐100 User Manual 

Note: 

The 

PROGRAM position will remain lit, and the 

RUN TIME position will be blinking, indicating that you are in 

PROGRAM mode, working on the RUN TIME aspect of the program.

4 Use the item selectors to select the station you wish to configure  and push the 

ENTER button.

Now the cursor jumps to the right of the display, allowing you to select the  station run time.

Tip:

Instead of browsing through the list of available stations  with the item selectors you can use the 

STATION button to  browse only stations with a defined run time.This comes in  handy when modifying run times of an existing program.

Note: 

The 

PROGRAM position will remain lit, and the 

RUN TIME position will be blinking, indicating that you are in 

PROGRAM mode, working on the RUN TIME aspect of the program.

23

NLC‐100 User Manual 

A couple of notes on run times:

• Run times longer than four minutes are run in ten second blocks and  will be rounded up to the nearest block.

For instance, run times of 00:04:14 and 00:04:18 will both be  rounded to 0:04:20.

• Run time shorter than four minutes are not rounded.

• The maximum run time is 17:59:50.

• You can "delete" a station from a program by simply setting the run  time to 0.

5 Use the item selectors to select the number of minutes you wish the  station to run, and push the 

ENTER button to save your setting.

Now the controller returns to the main screen for editing the run  time. Say you just set station number five to run five minutes in  program two, the display will look like this:

24

Pushing the 

CANCEL button when adjusting the run time will discard the  new run time and keep the original one, even if this is zero.

Now you can select other stations and repeat steps four and five to  determine how they should run in this program.

NLC‐100 User Manual 

Setting Water Days

There are three ways to determine which days a program will run.

• On all odd dates (1, 3, 5 etc.)

• On all even dates (2, 4, 6 etc.)

• On selected days in a 14 day cycle.You select the days and the NLC  will loop through the 14 day schedule.

To make the configuration as intuitive as possible, the 14 day period always  starts with the current day.

1 Turn the dial to 

PROGRAM

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display will look something like this:

25

NLC‐100 User Manual 

2 Use the item selectors to navigate to the program you wish to adjust  the start times for and turn the dial to the 

WATER DAYS position.

26

3 Use the item selectors to choose between "Odd dates", "Even  dates" or "14 day period" and push the 

ENTER button.

Note: 

The definition of an "Odd date" does not include the 31st  day in a month because this would cause the program to run  two days in a row (e.g. May 31 and June 1.) The same goes for 

February 29 on leap years.

If you select odd or even dates, you are done now, but if you select "14 day  period" you need to walk through the next steps as well.

NLC‐100 User Manual 

4 Assuming that today is a Sunday, the list of days will start with an 

"S" and a cursor will be blinking ontop of the first "S":

Selecting the water days

5 Now you can use the item selectors to navigate through the days. 

The up and down arrows will toggle the selected day to On/Off. 

Here's how selecting only Mondays, Wednesdays and Fridays would  look like:

6 Once happy with the selection of days, push the 

CANCEL button or  turn the dial away to go back to the main water days screen. If you  choose to turn away the dial, you will see the controller return to  the main water budget dialog.

27

NLC‐100 User Manual 

Now you can turn the dial to another position to edit the remaining aspects  of the program.

Setting Start Times

Each program in the NLC can run up to 12 times per day.

Note: 

When you set the first start time for a program the 

controller automatically sets the program as active. For more  information turn to 

Chapter 3: Activating/deactivating a 

Program

 on page 

37

.

1 Turn the dial to 

PROGRAM.

PAUSE/

RESUME

STOP

MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display will look something like this:

28

NLC‐100 User Manual 

2 Use the item selectors to navigate to the program you wish to adjust  the start times for and turn the dial to the 

START TIME position. 

Now you'll see the following display:

Note: 

If you are using the misting feature of NLC you will also  see 

Cyc and 

End fields:

29

NLC‐100 User Manual 

30

Misting allows you to determine a more complex irrigation scheme where  each start time is repeated a number of times within a specified time 

frame. For more information turn to  Appendix H: Advanced irrigation: 

Misting, Cycle and Soak on page 167.

3 Use the item selectors to locate the one of the 12 runs you wish to  set a start time for, and push the 

ENTER button. Now the cursor will  jump to the right, letting you set the start time:

4 Use the item selectors to select the start time and push the 

ENTER button.

NLC‐100 User Manual 

Tip:

 If you push the up and down arrow at the same time in this  field, you will delete the current start time all together.

5 Now the controller will return to the default display for setting start  times, and you can repeat steps two and three for all the start times  you wish to set.

6 Once you are all done, simply turn the dial on to what you need to 

Also, if you select another number for your start than the next  chronologically available one, the NLC will save your start with the next  chronologically available number anyway. 

This means that if you have two starts assigned and assign a third one but  to the "6" run slot, this will be saved as start 3 and appear as such the next  time you want to edit the program. 

In short, you can say that your start times are sorted by time and their  numbers "compressed" chronologically.

Adjusting Water Usage (Water Budget or ET)

There are two ways of determining how to adjust the amount of water  used by an irrigation program:

• Setting the "Water Budget" to a value between 0 and 250 percent. 

31

32

NLC‐100 User Manual 

Just as you would expect, this determines how much water is used. 

However, since the controller simply tells a station to start or stop,  the water budget doesn't control the water flow as such, but  instead it determines the run time.

This means that if you have set up a program to run five stations for 

10 minutes each, this is what will happen with the water budget set  to 100 percent. But if you decrease the water budget to 80 percent,  each station will only run eight minutes, and if you set the water  budget to 120 percent, each station will run for 12 minutes.

Note: 

If the water budget is zero, the station will not run at all.

• Letting ET adjustment decide how the irrigation should be carried  out. This way you tell the NLC how much water you want the  program to provide per day, and then the controller will adjust for 

any ET and Rain input it receives. For more information turn to  

Appendix B: Adding an ET Device on page 87.

The following two procedures walk you through configuring a program for  each of the two options.

1 Turn the dial to 

PROGRAM

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display will look something like this:

2 Use the item selectors to navigate to the program you wish to adjust  the water budget for and turn the dial to the 

ET position.

Now you'll see the following display:

33

NLC‐100 User Manual 

34

Note: 

Please see the note below, "On switching between Water 

Budget and ET adjustment" on page 37.

3 Use the item selectors to choose "Water Budget" and push the 

Water Budget button. Now you'll see the following screen:

4 Use the item selectors to set the appropriate water budget and push  the 

ENTER button to save the setting and exit.

NLC‐100 User Manual 

Note: 

Adjusting the water budget is an easy way to  accommodate shifting weather conditions without having to  reconfigure all programs to apply more or less water. Just  increase or decrease the water budget as needed, and the 

Adjusting the ET (Water budget)

1 Turn the dial to 

PROGRAM

PAUSE/

RESUME

STOP

MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display will look something like this:

35

NLC‐100 User Manual 

2 Use the item selectors to navigate to the program you wish to adjust  the water budget for and turn the dial to the 

WATER BUDGET / ET position.

3 Use the item selectors to choose "ET" and push the 

ENTER button. 

Now you'll see the following display:

36

Note: 

.

Budget and ET adjustment

4 If you want the program to run before it has received an ET budget  from the controller, you can provide one manually that will then be  used as the starting point. After that, any ET figure that is received  will be added to what you already entered ‐ thus you can also use 

this feature to do a one‐time adjustment of the ET. For more  information turn to  Appendix B: How ET Works with the NLC on  page 87.

Use the item selectors to set your desired ET budget for today.

NLC‐100 User Manual 

5 Push the 

ENTER button to save your setting.

6 Programs that use ET adjustment instead of Water Budget  adjustment will display the ET value instead of the Water Budget  value in 

PROGRAM mode:

On switching between Water Budget and ET adjustment

If you have previously set a program to be adjusted by either Water Budget  or ET, choosing the opposite setting will generate one of two warnings:

Activating/deactivating a Program

You can toggle the Active/Passive status of each of the 10 programs ‐ only  active programs are actually run. By default, newly created programs are  set to Active as soon as you assign the first start time to them.

37

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

To toggle a program between Active and Passive:

1 Turn the dial to 

PROGRAM

Now the display will look something like this:

38

2 Use the item selectors to select the program you wish to toggle  active or passive and turn the dial to the 

PROGRAM STATUS position:

NLC‐100 User Manual 

3 Use the item selectors to toggle between Active and Passive mode  and push the 

ACTIVE/PASSIVE to save your selection and exit to the  main display for Program mode.

Note: 

Making a program passive does not erase the program. In 

fact, a passive program can still be run manually. For more  information turn to 

Chapter 4: Running NLC in Manual Mode

 on  page 

51

 and 

Capter 4: Running Extra Programs in Auto Mode

 on 

The NLC lets you configure two stations to activate booster pumps, and  each irrigation program can have one of these booster pumps associated. 

Here's how you assign a booster pump to a program:

1 Turn the dial to 

ADVANCED

39

40

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display looks like this:

2 Select 

6. Booster to Program Assignment and push the 

ENTER button.

3 Use the item selectors to select one of the 10 programs and push the 

ENTER button.

4 Now use the item selectors to select between "Non", "BO1" or 

"BO2":

NLC‐100 User Manual 

5 Once done, push the 

ENTER button to save the setting.

6 Now you can repeat steps three and four for to assign booster  pumps to more programs, or push the 

CANCEL button to return to  the main display for Advanced mode.

Adding a Master Valve (Supply Pump)

You might want to have the NLC control the opening of your supply pump  when irrigation is active, and shut it down when irrigation is over.

Note: 

A station can not run a pump on its own ‐ you must attach  a relay connected to an external power source and the station  will then activate the relay.

Testing a Program

After setting up your programs, you might want to test them without  having to wait around for all of them to actually run.

41

42

NLC‐100 User Manual 

Since this is the same approach as you would take in a troubleshooting  scenario, please refer to the separate Installation and troubleshooting  manual. 

NLC‐100 User Manual 

Chapter 4: Running the NLC

Day to day usage of the NLC is pretty simple ‐ the whole point of having a  system like this is to automate the irrigation, so little or no intervention will  be needed once your system is up and running.

Running NLC in Auto Mode

Once your system is configured, turn the dial to the 

AUTO position:

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display will tell you which program will run next:

43

NLC‐100 User Manual 

In this case the next program that will run is number one. It has two  stations and will run on Tuesday at 09:44 PM for 40 minutes.

You don't have to do anything more ‐ just leave the controller in 

AUTO mode and the program will be run automatically. Once the program starts,  the display will tell you what station is running, and the remaining run time  for both the running station and the entire program:

Running program Running station Current time

Remaining program run  time

Remaining station run time Current flow

Once this program has finished, the next one in line will appear in the  display.

Up to 10 programs can run in parallel (only 4 programs per connect bord  on NLC‐H and NLC‐S).

Tip: 

You can always get an overview of running programs and  stations by using the item selectors: Use the left/right arrows to  select between programs and stations and the up/down arrows  to browse through the items (programs or stations).

44

NLC‐100 User Manual 

Pausing a Running Program

From time to time it may be necessary to pause the irrigation. Here's how  you put a running program on hold:

1 Use the item selectors to locate the program you wish to pause, and  push the 

PAUSE/RESUME button.

The response from the controller will vary depending on the status of the  program and the number of programs running:

If the program you select is the only one running you'll see this display:

If the program you select is one of several running programs you'll see this  display:

If the program you select is not running but other programs are, you'll see  this display:

45

NLC‐100 User Manual 

2 Push the button that suits your intentions (

PAUSE/RESUME or

PROGRAM

) and the controller will pause the program(s) and return to  the list of programs:

Once you're ready to resume the program, follow this procedure:

Resuming a paused program

1 Use the item selectors to locate the program you wish to resume,  and push the 

PAUSE/RESUME button.

Depending on whether one or more programs are paused you'll see  different displays, according to what you did when you paused the  program(s).

46

NLC‐100 User Manual 

2 Push the button you need according to the instructions in the  display.

3 When the program(s) resume(s), the display will look as if the  program(s) had just kept running.

Note: 

The last ten seconds of a program might be re‐run, so  each pause/resume will potentially add ten seconds to the total  run time for that program.

Running Extra Stations in Auto Mode

When the NLC is running in auto mode you have the option of manually  starting additional stations simultaneously. This can come in handy if a  certain part of the terrain needs a little extra watering but you don't want  to reconfigure a program for just one time's sake.

Note: 

The NLC supports up to 12 simultaneously running  stations. This means that if for instance two programs are  running, you can start ten more stations manually.

Running a station manually

1 Push the 

STATION button and the following display appears:

47

NLC‐100 User Manual 

2 Use the item selectors to select the station you wish to activate. If  you're happy with the suggested run time, push the 

ENTER button. 

Otherwise push the right arrow of the item selectors to move the  cursor to the right to adjust the run time and then push the 

ENTER button. Now the station will start running immediately:

48

You can use the item selectors to browse through the list of running  stations and programs from this display.

If you want to run more stations manually, just go through this procedure  again for each station you want to activate.

To stop a manually started station before the end of its run time, use the 

item selectors to locate it and push the 

STOP button.

NLC‐100 User Manual 

Note: 

You can always get an overview of running programs and  stations by using the item selectors: Use the left/right arrows to  select between programs and stations and the up/down arrows  to browse through the items (programs or stations).

Running Extra Programs in Auto Mode

When the NLC is running in auto mode you have the option of manually  starting additional programs in parallel.

Note: 

If you select programs that try to start the same station  in overlapping periods, the station will start when the first  program asks for it and stop when the last program doesn't  need it any more.

So, if program 1 wants to run station 12 from 08:00 to 08:10 and program 

2 wants to run that same station from 08:05 to 08:15, the station will be  run from 08:00 to 08:15.

Running a program manually has the advantage that you can select which  station should be run first, allowing you to skip a part of the program.

1 Push the 

PROGRAM button.

Now there will be an arrow next to the program number, indicating that  you should select the program you wish to run:

49

50

NLC‐100 User Manual 

2 Use the item selectors to pick the desired program and push the  right arrow in the item selectors to move on to select which station  should be the first to run:

3 Use the item selectors to select the station you wish to start with,  and push the 

ENTER button. Now the controller will run the selected  program, keeping you informed of the status of the program:

NLC‐100 User Manual 

You can browse through the status of running programs with the item 

selectors.

If you want to run more programs manually, just go through this procedure  again for each program you want to activate.

To stop a manually started program before the end of its run time, use the 

item selectors to locate it and push the 

STOP button.

Note: 

You can always get an overview of running programs and  stations by using the item selectors: Use the left/right arrows to  select between programs and stations and the up/down arrows  to browse through the items (programs or stations).

Running NLC in Manual Mode

The NLC allows you to run all programs and stations manually only ‐ not  obeying the schedules for the 10 programs. To enable this feature, turn the  dial to the 

MANUAL position:

51

NLC‐100 User Manual 

Note: 

Please check the setting of the "Revert to auto" feature 

before working in manual mode. For more information turn to 

 

Chapter 5: Feature Manager

 on page 

70

.

PAUSE/

RESUME

STOP

MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the controller is ready to run programs or stations manually, and  you're prompted to select one of the two:

52

From here on, the procedure for running stations is identical to Running a 

station manually. For more information turn to Chapter 4: Running a 

station manually on page 47.

NLC‐100 User Manual 

Tip: 

You can manually run programs and stations  simultaneously.

Alarms

When running in 

AUTO or 

MANUAL mode, the NLC will react on a number of  conditions by raising one or more alarms.

Note: 

Though some alarms, like a rain alarm, can halt the  execution of irrigation schedules, you can always start both  stations and programs manually, even when there is an active  alarm. Two exceptions: if a short alarm is active, you can not  start anything, and if a station is failing you can not start this  manually.

Becoming aware of alarms on‐site

If the NLC has received an alarm, and is in 

AUTO or 

MANUAL

mode (For more  information turn to Chapter 4: Running the NLC on page 43), the bottom 

row of the display will toggle between normal text and the alarm that has  arrived.

For example, if you had a rain alarm at 01:10 PM, your display will toggle  between normal mode and alarm notification:

53

NLC‐100 User Manual 

54

The display will toggle between the two modes in short intervals.

If you had multiple alarms the controller will toggle to a different alarm  each time it toggles to notification.

Note: 

If you had more than three alarms the fourth message in  the bottom row of the display will say that you should visit the  alarm list for details ‐ the display will look something like this:

NLC‐100 User Manual 

Receiving alarm notifications on email

If your communication subscription with your supplier allows it, the NLC  will support sending out alarm notifications to one or more email  addresses.

Note: 

This requires the WIN‐100 or LAN‐200 module.

To configure your controller to email alarms, follow this procedure:

1 Turn the dial to 

ADVANCED

55

56

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display looks like this:

2 Scroll down to 

Alarm Notification and press the 

ENTER button. 

Now you see the following display:

NLC‐100 User Manual 

3 Select 

Email addresses and press the 

ENTER button. If no email  addresses are entered, you can select 

Add new

:

Now you can enter an email address using the up/down arrow keys to  select the characters. Once you are done, press the 

ENTER button.

4 Next you configure which alarms should be emailed. Select 

Alarm

Notification settings and press the 

ENTER button. Now you see  the following display:

57

58

NLC‐100 User Manual 

Here you can scroll between the different alarms emitted by the controller.

5 Select the alarm you wish to configure and press the 

ENTER button. 

Now you see the following display:

You can select each email address you have entered, and determine if you  want an email when this type of alarm is raised and/or when it is recalled.

NLC‐100 User Manual 

Setting

On

Off

6 Select the email you wish to configure for the current alarm and  press the 

ENTER button. Use the arrow keys to set On and Off to  either Yes or No ‐ see the explanation table below:

Selection

Yes

No

Yes

No

Meaning

Send email when the alarm is raised

No email when the alarm is raised

Send email when the alarm is recalled

No email when the alarm is recalled

Viewing the alarm list

To view the list of alarms in the NLC, follow this procedure:

1 Turn the dial to the VIEW ALARMS position. Now you'll see a  scrollable list of the different types of alarms known to the NLC:

In this case there is no 

Off time for the alarm, meaning that the alarm is  still on. Had the alarm ceased you would see the end time too.

Use the item selectors to scroll through the list. The list contains  information on the latest observed alarms of the 12 known alarm types:

59

NLC‐100 User Manual 

Note: 

The alarm list will not survive a power failure ‐ if the  controller loses power, the list is wiped clean.

Alarms in the NLC

Short name in  display (Alarm type)

Full name / Description

1. Rain

2. Alarm

3. ET

How to clear alarm (see note  below)

Rain alarm.

Evapotranspiration alarm.

This will only ever be raised if  you're running in "ET‐enabled" 

mode. For more information  turn to  Appendix B: How ET 

Works with the NLC on page 

87.

Will automatically disappear  when it stops raining.

Whatever alarm you have  attached to the alarm termnial. 

If you're using the AUX terminal  for a flow sensor, you won't  ever see this alarm.

The alarm stays on as long as  the attached alarm is active,  but you can clear it by  viewing the alarm list.

Will automatically disappear  when the "ET enable" device  is no longer controlling your  irrigation.

60

NLC‐100 User Manual 

Short name in  display (Alarm type)

4. Short

Full name / Description

5. High F

6. MPF

How to clear alarm (see note  below)

Short alarm.

Note

A short alarm may really be a 

"Broken Fuse" alarm or a  general "Overload" alarm ‐ it  need not be a true short in your  system.

Overload is defined as a current  of more than 2A for more than  five minutes.

If you enable current readings,  you will get a "FUSE" message  in the display if a fuse is blown  out.

You may also run the electrical  test for a specific station and  get a definite answer to  whether there is an overload  situation of a blown fuse in that  station. 

The alarm stays on as long as  there is a short in your  system. You can clear the  notification by viewing the  alarm list.

High flow alarm

Main pump failure

The alarm stays on as long as  the flow is too high.You can  clear the notification by  viewing the alarm list.

The alarm will be cleared  once you have viewed the  alarm list and acknowledged  the alarm.

61

NLC‐100 User Manual 

Short name in  display (Alarm type)

7. USch F

Full name / Description

8. St. Err

9. Max St.

How to clear alarm (see note  below)

Unscheduled flow alarm. This  means that water is flowing in  your pipes when you're not  irrigating. Such an alarm  indicates that you have a leak.

Stays on as long as the flow is  too high. The normally open  master valve (NOM) will be  activated, so the alarm will  clear itself, but you can clear  the notification by viewing  the alarm list.

Station error alarm.This means  that one or more stations in the  field have failed, and will only  be raised if you are using a flow  sensor.

Note

This alarm only concerns flow  related problems ‐ not any  electrical errors that may occur  in a station. 

Stays on until all stations are 

labeled OK (For more  information turn to  

Appendix C: Inspecting and 

Toggling Station Status on  page 126).You can clear the 

notification by viewing the  alarm list.

Maximum number of stations  reached. This means that a  program tried to start a station  when the maximum number of  stations was already running.

The alarm will be cleared  once you have viewed the  alarm list and acknowledged  the alarm.

62

NLC‐100 User Manual 

Short name in  display (Alarm type)

10. Repeat.

Full name / Description

11. NW Prg.

12. NW Stp.

13. Mst NR.

14. Mst Lv.

How to clear alarm (see note  below)

The number of repeats has  been reduced in a misting  program. This typically happens  if ET expands the run time for repeats and the  program can't fit all the repeats  into the configured time frame. 

For more information turn to  

Appendix H: Advanced  irrigation: Misting, Cycle and 

Soak on page 167.

The alarm will be cleared  once you have viewed the  alarm list and acknowledged  the alarm.

A program has not been run  because it was set to start in  the non‐water time window. 

For more information turn to  

Appendix G: Defining a custom 

irrigation period on page 163.

The alarm will be cleared  once you have viewed the  alarm list and acknowledged  the alarm.

A program was halted because  it was running when entering  the non‐water time window. 

For more information turn to  

Appendix G: Defining a custom 

irrigation period on page 163.

The alarm will be cleared  once you have viewed the  alarm list and acknowledged  the alarm.

There is no response from your  moisture sensors.

One or more of your moisture  sensors is reporting a moisture  level below the alarm  threshold.

Stays on until the sensors are  all responding.

Stays on until the moisture  level is above the threshold.

63

NLC‐100 User Manual 

Short name in  display (Alarm type)

Full name / Description How to clear alarm (see note  below)

15. Rem ET

Your controller is not receiving 

ET data from the remote ET  server.

The alarm will be cleared  once you have viewed the  alarm list and acknowledged  the alarm.

2 When you have viewed the list of alarms you will no longer be  notified in the display about past alarms. Of course you can always  revisit the list.

Monitor Data

If your communication subscription allows, you can enable the controller  to send monitor data to your Web interface.

To enable relaying monitor data to your Web interface, follow this  procedure:

1 Turn the dial to 

ADVANCED

64

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display looks like this:

2 Use the arrow keys to select 

Monitor Data and press the 

ENTER button. Now you see the following display:

65

NLC‐100 User Manual 

66

3 Select 

E nable/Disable mon events

.

Now you get a list of all the events that can trigger monitor data. For each  of these you can select them using the 

ENTER button and enable/disable  them:

• Programs

• Stations

• Daily Water Usage

• Hourly Water Usage

• System Mode Change

• Alarms & Rain Shutdown

• Installation Data Change

• Program Data Change

• Moisture

• Clock Changed

• Water Window

• Daily ET and Rain

• Daily Assigned Program ET

• Hourly Rain

NLC‐100 User Manual 

4 Finally you can configure how often the controller should poll the  board for problems. From the main 

Monitor Data menu select 

Board surv log interval and you will see the following display:

5 Select your desired interval and press the 

ENTER button.

Rain Shutdown

Despite all the features controlling irrigation in your NLC you still have a  manual handle to pull if you want to halt irrigation immediately ‐ typically  if heavy rain sets in.

To halt all irrigation immediately, simply turn the dial to 

RAIN OFF

:

Note: 

The rain shutdown can be enabled for 999 hours.

67

68

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

You will be prompted to enter the number of hours you wish to halt  irrigation. Use the item selectors to enter the number of hours and press  the 

ENTER button to start the shutdown.

To end the shutdown, push the 

CANCEL button.

NLC‐100 User Manual 

Chapter 5: Advanced Features

Intelliset

With the Intelliset feature set you can allow external evapotranspiration 

(ET) devices to control your irrigation.

Intelliset comes in a couple of flavors:

• Simple ET which allows a WR7 Receiver to tell the NLC if it should  irrigate today or not.

• Complex ET control based on historical ET data: you enter the  historical ET correction figures for the entire year and use these to  adjust your irrigation throughout the year.You can also use the  historical data as a fall‐back mechanism for a connected weather  station.

• Complex ET control which allows the NLC to adjust the irrigation  level based on ET data from a weather station ‐ exact amount of rain  and environmental conditions.

• Complex ET control based on remote ET data received from a  central ET server.

All methods ensure more efficient water consumption than you would see from using a "flat" irrigation scheme throughout the year.

In addition the NLC provides two extra sources of information about irrigation needs:

• Moisture sensors that will tell you exactly how moist your soil is,  giving you the best evidence of how much irrigation is needed.

• "Extended rain shutdown" ‐ a feature that will halt all irrigation  after a rain alarm has occurred, regardless of what your ET tells you  about irrigation needs.

• For more information turn to  Appendix B: Adding an ET Device on  page 87.

69

NLC‐100 User Manual 

FloGuard

FloGuard is the NLC safety system that constantly monitors the controller for potential problems and raises alarms when needed.

FloGuard will detect things like pipe leaks, faulty stations, malfunctioning pumps and many other things that could otherwise go unnoticed and damage your system.

You will also get notifications of "normal" alarms like rain alarms, ET input, short circuits and any alarms stemming from your own auxiliary input devices.

Note: 

FloGuard requires a flow meter to be connected.

FloStack

The FloStack feature set helps you plan and control the flow in your system.

By entering an expected flow for each station and a maximum system flow capacity you can ensure that the NLC will not try to start more valves than the system can feed.

An extremely handy feature is the "Learn Flow" feature that automatically detects the flow of each station by running all stations in turn and comparing with measurements from a flow sensor.

You can read about FloStack in For more information turn to  Appendix C: 

Adding a flow sensor on page 109.

Feature Manager

The Feature Manager lets you enable a few extra features that not all users will need, most notably the Mist Manager.

With the Mist Manager you can add an extra perspective on running irrigation schedules. Instead of a program just running one station at a time for a fixed

70

NLC‐100 User Manual  duration, you can break each run into multiple cycles.

Instead of telling the NLC to run a number of stations for three minutes each, you can tell it to run each station in 18 second time slices 10 times with breaks in between.This adds up to the same water consumption, but allows the irrigation to soak in between the cycles.

Irrigation cycles that are measured in seconds are typically referred to as "misting", whereas cycles that are measured in minutes are referred to as "Cycle & Soak".

You can read all about the Feature Manager in For more information turn  to  Appendix H: Advanced irrigation: Misting, Cycle and Soak on page 167.

Another feature is "Revert to auto", which will pull your controller back into auto mode, when it has been sitting in other modes for 10 minutes. This ensures that irrigation will always be resumed, even if someone leaves the controller hanging in a random menu item.

Note: 

The controller will not revert to auto if in "Irrigation off"  or "Extended rain shutdown". Also, when performing a short  finding, the time limit is not 10 minutes but three hours. This  feature is enabled by default.

71

72

NLC‐100 User Manual 

NLC‐100 User Manual 

Appendix A: How Amount Based Rain 

Alarms Work

The following examples show how the amount based rain alarm works. In  all the examples the usable rain is 0.86”.

Example A.1

.

Daily ET

0.20" (standard)

Max. hourly  rain

0.20"

Soil holding

0.50"

Rain alarm limit

0.02"

The graphs show the rain built up the balance whenever it rains. Every hour  the balance is reduced by a fraction of the Daily ET ( ¼ during the night and 

¾ during the day). When the balance reaches the Rain alarm limit the rain  alarm will go on/off.

73

74

NLC‐100 User Manual 

The second rain burst shows a situation where the max hour rain limits  makes limitations. More details below.

The third rain burst shows that we hit the soil holding and by that limit the  balance.

Note: 

The graph spans three full days.

NLC‐100 User Manual 

This graph shows how the balance grows minute by minute. At each whole  hour the balance is corrected for max hourly rain and for the hourly dry  out. In this case the hour between 7 AM and 7 AM has too much rain  compared to max hourly rain and the balance is reduced.

Example A.2.

Daily ET

0.20" (standard)

Max. hourly  rain

0.20"

Soil holding

0.50"

Rain alarm limit

0.10"

In this graph we see the same as in example 1 except that the rain alarm  goes on later and off earlier.

75

NLC‐100 User Manual 

Note: 

The graph spans three full days.

Example A.3.

Daily ET

0.30" (standard)

Max. hourly  rain

0.20"

Soil holding

0.50"

Rain alarm limit

0.02"

76

This shows a more dry condition with higher ET than standard. The alarm  period is then shorter.

NLC‐100 User Manual 

Note: 

The graph spans three full days.

Configuring the Extended Rain Shutdown 

Feature

Given enough rain, at some point the NLC will halt irrigation (based on the  values you have set in Section A.1. However, there is a way to further refine  this feature by defining:

• How many hours the rain alarm must be active before an extended  rain shutdown will actually occur.

• If the extended rain shutdown should be longer than the duration  of the rain alarm.

• For how long the extended rain shutdown can last.

Note: 

The Extended Rain Alarm behaves exactly as if you turned  the dial to 

RAIN OFF

(For more information turn to 

Chapter 4: 

Rain Shutdown

 on page 

67

).

First you must enable the extended rain shutdown feature set:

1 Turn the dial to 

ADVANCED

77

78

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display looks like this:

2 Select 

8. Feature Manager.

 Now you will see the following:

NLC‐100 User Manual 

3 Select 

2. Ena/Dis Extended Rain Alarm

. Now you will see the  following:

4 Select 

Enable and push the 

ENTER button to save.

Now you are ready to actually configure the extended rain shutdown  parameters:

1 Use the item selectors to select 

3. Intelliset and push the 

ENTER button. Now you'll see the following screen:

79

NLC‐100 User Manual 

2 Select

3. Extended Rain Alarm.

 Now you see the following  screen:

Important

Note: 

Note: 

You will only see this menu item if you enabled the  feature as described in the previous procedure.

The three values you must set here are:

80

NLC‐100 User Manual 

Setting

Minimum Rain 

Duration

Adjustment

Description

For how long must the rain alarm have been active before an  extended rain shutdown takes place.

You can use this value to prolong the duration of the rain  shutdown. If the rain alarm has been active for an hour and  you set the adjustment to 3.0, the shutdown will last three  hours.

Max. Shutdown How many hours can the rain shutdown be kept up. Value is  between 0 and 999 hours.

Examples using Different Parameters

The following examples show how the extended rain shutdown feature  works on different parameters. It is important to notice that using the 

amount based rain alarm feature in the NLC (For more information turn to  

Appendix A: How Amount Based Rain Alarms Work on page 73) utilize the 

normal ET to simulate a dry out, which means the rain alarm will stay on as  long time as the applied rain will last in respect to ET. Normally it will not  be necessary to extend the rain alarm in these cases. If a rain contact is  used without any dry out mechanism the extended rain shutdown is an  excellent feature to avoid irrigation for a period after rainfall.

Example A.4.

Rain min. duration

45 minutes

Adjust factor

1 (1:1)

Max shutdown

999 hours

81

NLC‐100 User Manual 

Note: 

Setting a value to zero is the same as disabling the  feature.

The graph shows how the extended rain shutdown extends the rain alarm. 

The rain itself is of course 1 hour for 60 minutes, but the extended rain  shutdown on top of that varies depending on the parameters. In this case  the factor is one so 60 minutes rain alarm gives an extension with one hour  rain shutdown. Note that the first 45 minutes don’t have extensions due to  the Rain Min Duration.

Example A.5

Rain min. duration

45 minutes

Adjust factor

5

Max shutdown

999 hours

82

NLC‐100 User Manual 

In this example the adjust factor extend each rain alarm hour with 5 hours  rain shut down. So 6 hours rain alarm with prevent irrigation for 6+30=36  hours.

Example A.6

Rain min. duration

45 minutes

Adjust factor

0.5

Max shutdown

999 hours

83

NLC‐100 User Manual 

In this example the factor is 0.5 and thus the rain shutdown extension is  only half of the rain alarm.

Example A.7

Rain min. duration

45 minutes

Adjust factor

5

Max shutdown

20 hours

84

NLC‐100 User Manual 

This example has the same factor as example 2, but the max shutdown  limits the rain shutdown extension in the case of long rain alarm periods.

85

86

NLC‐100 User Manual 

NLC‐100 User Manual 

Appendix B: Adding an ET Device

Evapotranspiration (ET) devices can help the NLC adjust irrigation based on  weather conditions.You can either let an ET device provide daily input on  how the irrigation should be adjusted, or you can enter historic ET data on  how the weather usually behaves throughout the year and the controller  will adjust its irrigation accordingly.

Note: 

Historical ET data acts as "fall back" data for the  controller if the communication with a connected weather  station should fail. Thus, you should enter historical ET data  even if you are using a weather stations.

How ET Works with the NLC

The NLC will receive ET data from an external weather station or from a  historical ET report describing the evaporation throughout the year. 

Combining this data with the input from a rain sensor or a tipping rain  bucket, and the expected level of irrigation the controller can calculate  exactly how much water to use for irrigation.

Here's a rough breakdown of how ET works with the NLC ‐ the items are in  no particular order but should all be considered when planning for ET  adjusted irrigation:

• The controller needs a number of inputs in order to calculate the ET  correction:

• Amount of water that has evaporated and transpired (The ET figure)

• Amount of rain fall (The rain figure)

• How much water the soil can retain (Soil holding)

• How much water is used for irrigation under normal circumstances

• The ET and rain figures are provided by a weather station and a rain 

87

NLC‐100 User Manual  sensor ‐ the rest is entered by you at the controller (if you use  historical ET data, this is entered at the controller as well).

• Every day at midnight the controller adds up the ET and rain input it  has received and calculates how to adjust tomorrow's "ET Budget" 

‐ the amount of water that the irrigation should provide.

Note: 

If you use a custom irrigation period, this happens at the 

start of your irrigation period, which might not be midnight. For  more information turn to 

 Appendix G: Defining a custom  irrigation period

 on page 

163

.

Let's look at two examples ‐ one where ET has exceeded the rain fall, and  one that works the other way around:

Example B.1. ET calculation with rain shortage

In this example the rain fall has not been able to make up for the ET.

• 0.30" of water was lost due to ET in the last 24 hours.

• 0.20" of rain has fallen in the last 24 hours.

• Your soil holding is set to 0.50".

Now we're short of 0.10" of water since this is the difference between ET  and fallen rain. Thus the ET Budget for tomorrow will be adjusted with 0.4".

Since we don't have any excess water, the soil holding value is irrelevant.

Example B.2. ET calculation with excess rain

88

NLC‐100 User Manual 

In this example the relationship is reversed and we have more rain than ET 

‐ soil holding is the same.

• 0.30" of water was lost due to ET in the last 24 hours.

• 0.90" of rain has fallen in the last 24 hours.

• Your soil holding is set to 0.50".

You would think that the ET budget for tomorrow should simply be  adjusted with ‐0.6" because the excess rain lets us irrigate 0.6" less. 

However, since the soil is only capable of holding 0.5" we can not benefit  from all of the rain, but only 0.5" of the 0.6". Conclusion: tomorrow's ET  budget will be adjusted with ‐0.5", meaning that we will not need to  irrigate at all. Unless, of course, the ET budget is still positive after adjusting  with ‐0.5.

In other words: we can never benefit more from fallen rain than the soil is  capable of holding back. So this example will end up with a ‐0.5"  adjustment no matter how much more rain we have had. 

• If you don't connect a weather station but let your programs run  from historical ET data the controller simply reads the historical  data each midnight, subtracts the rain figure and adds the result to  the ET budget.

Note: 

You can still use a tipping rain bucket to measure fallen  rain and have this affect the ET correction. Soil holding is still a  limiting factor on how much we can benefit from rain fall.

Note: 

When the NLC looks at the ET budget and has to figure  out how long it has to irrigate, it looks at the "ET Base" setting 

(see Step 4 Page 105 for instructions on how to set this value).

89

NLC‐100 User Manual 

A bit of background is needed to understand how this works:

When the controller is irrigating normally, it is considered to be irrigating 

at a water budget of 100% (For more information turn to Chapter 3: 

Adjusting Water Usage (Water Budget or ET) on page 31). In order for the 

ET figure to make sense to the controller, you need to tell it what the ET  figure would be when running at a 100% water budget. So, if the "ET Base"  setting 

1

 is 0.20", and today's ET budget says 0.10", the controller will run  at a water budget of 50 percent, meaning that programs will only run 50  percent of their configured run time.

The tricky part is to make your irrigation programs fit into this model. If the 

"ET Base" setting is 0.20", you have to make sure that all your programs are  configured to apply exactly 0.20" every day. So you have to look at the  application rate in each zone and adjust run time and number of start times  accordingly.

Let's look at an example:

Example B.3. Calculating ET run time

The following formula is used to calculate the run time (values explained in  the table below): ( 60 x ET0 x Kc ) / ( Pr x Ie )

60

ET

0

K c

P r

I e

Description

A constant value

Evapotranspiration base

Crop coefficient

Precipitation rate from  manufacturer's data

Irrigation coefficient

60

0.20

0.50

0.45

0.80

Example value

1. We recommend using the highest monthly ET for your area as the base.

90

NLC‐100 User Manual 

Based on the example values above, the run time would be:

(60 x 0.20 x 0.50) / (0.45 x 0.80) = 16.7 minutes.

• It is possible to set a minimum ET value that determines whether 

irrigation will take place at all (see Step 4 Page 105). There can be 

several reasons to set a minimum ET value:

• If you only provide an insignificant amount of water, the effect is  useless.

• If you have rotating valves, maybe they won't make a complete  rotation before their short run time is over, and you'll get uneven  irrigation.

But isn't a bit of water better than no water at all? Yes, but take a look at  this example to see why setting a minimum ET can be a good idea:

Example B.4. How minimum ET value works

In this example we assume the following circumstances for the program in  question:

• Today's ET budget has been adjusted to 0.4".

• The program has four start times.

• The minimum ET value has been set to 0.2" because irrigating less  than this gives you an uneven irrigation and has little effect on the  turf.

Each of the four start times can irrigate one fourth of the total ET budget,  meaning 0.1". Here's how each of the four start times will take place:

91

NLC‐100 User Manual 

1

Start time #

2

3

4

Action Explanation

No irrigation The budget is 0.4" and there are four starts left,  meaning that each must provide 0.4/4 = 0.1"  which is below the 0.2" minimum.

No irrigation The budget is 0.4" and there are three starts  left, meaning that each must provide 0.4/3 = 

0.13" which is below the 0.2" minimum.

Irrigation The budget is 0.4" and there are two starts left,  meaning that each must provide 0.4/2 = 0.2"  which equals the 0.2" minimum.

Now the 0.2" that the program provided is  subtracted from the budget, so the budget is  now 0.2".

Irrigation The budget is 0.2" and there is one start left that  must provide 0.2/1 = 0.2" which equals the 0.2"  minimum.

Now the ET minimum value has ensured that we got two useful irrigations  instead of four uneven irrigations.

Examples

The following examples show a week with ET, Rain, ET balance and  irrigation with various combinations of ET parameters.

Example B.5. All parameters in use

Min. ET

0.20" 0.35"

Max. ET

0.40"

Soil holding Max. hourly rain

0.10"

92

NLC‐100 User Manual 

The program is set to run one time every day; i.e. it will if ET balance is  greater than Min ET. The example starts with 0.20” ET, no rain and an  empty ET balance.

Numbers

12:01 

AM

Day Starting  balance

Past

24 Hour Cycle

Irrig atio n

E.T.

Rain Etc.

11:59 PM

End  balance

0.20

0.00

0.20

0.20

1 0.20

0.20 0.29

0.10

0.19

0.19

This is what we  have when day 1  starts

Irrigate ETc from  last day

93

NLC‐100 User Manual 

2

3

4

0.19

0.51

0.31

5

6

7

‐0.26

‐0.40

‐0.19

Table Explanation

0.00 0.32

0.35 0.26

0.00

0.11

0.32

0.15

0.51

0.31

0.31 0.27

0.53

‐0.26 ‐0.26

0.00 0.28

0.50

‐0.22 ‐0.40

0.00 0.24

0.00

0.24

‐0.16

0.00 0.29

0.00

0.29

0.13

No irrigation as ET  balance < Min. ET 

(0.20)

Irrigate for the last  two days, but only 

Max ET (0.35)

Irrigation during  night. Rain comes  during the day.

No irrigation as ET  balance < 0

No irrigation as ET  balance < 0

7/1

Date

7/2

7/3

7/4

7/5

Explanation

The ET balance is set to ETc = ET – Rain. As the ET balance >= Min ET  the program will run and use the entire ET balance.

The ETc = 0.19, which is added to the ET balance. As the ET balance  is less than Min ET the program will not run.

The ET balance will now be the sum of ETc for 7/2 and 7/3; i.e. 0.51”. 

As this is above the Max ET the program will only apply 0.35” and  the remaining 0.16” will be left in the ET balance.

Just a normal day. ET – Rain from the past day is added to the ET  balance and it irrigates.

A lot of rain. ETc becomes negative and so do the ET balance. No  irrigation.

94

NLC‐100 User Manual 

7/6

Date

7/7+8

Explanation

Another day with a lot of rain. The ET balance would have been ‐

0.48” if it wasn’t limited by the soil holding of 0.40”

Positive ETc and the ET balance increases, but still no irrigation.

Example B.6. No Min ET

Min. ET

0.00" 0.35"

Max. ET Soil holding

0.40"

Max. hourly rain

0.10"

The program is set to run one time every day; i.e. it will if the ET balance is  greater than Min ET.The example starts with 0.20” ET, no rain and an  empty ET balance.

95

NLC‐100 User Manual 

Numbers

3

4

5

12:01 

AM

Day Starting  balance

Past

1

2

0.20

0.19

24 Hour Cycle

Irrig atio n

E.T.

Rain Etc.

11:59 PM

End  balance

0.20

0.00

0.20

0.20

0.20 0.29

0.10

0.19

0.19

0.00 0.32

0.00

0.32

0.51

No irrigation as no  min. ET.

0.32

0.15

‐0.26

0.32 0.26

0.11

0.15

0.15

0.15 0.27

0.53

‐0.26 ‐0.26

0.00 0.28

0.50

‐0.22 ‐0.40

6

7

‐0.40

‐0.16

0.00 0.24

0.00 0.29

0.00

0.00

0.24

0.29

‐0.16

0.13

No irrigation as ET  balance < 0. 

Limited by soil  holding.

No irrigation as ET  balance < 0

No irrigation as ET  balance < 0

Table Explanation

Date

7/1‐4

7/5

7/6

Explanation

The ET balance is set to ETc = ET – Rain. As the ET balance is >= Min 

ET the program will run and use the entire ET balance.

A lot of rain. ETc becomes negative and so does the ET balance. No  irrigation.

Another day with a lot of rain. The ET balance would have been ‐

0.48” if it wasn’t limited by the soil holding of 0.40”

96

NLC‐100 User Manual 

7/7

7/8

Date Explanation

Positive ETc and the ET balance increases, but still no irrigation.

Now we begin to irrigate again.

Example B.7. No Max ET

Min. ET

0.20"

Max. ET

0.00" (Infinite)

Soil holding

0.40"

Max. hourly rain

0.10"

The program is set to run one time every day; i.e. it will if the ET balance is  greater than Min ET.The example starts with 0.20” ET, no rain and an  empty ET balance.

97

NLC‐100 User Manual 

Numbers

1

2

3

12:01 

AM

Day Starting  balance

0.20

0.19

24 Hour Cycle

Irrig atio n

E.T.

Rain Etc.

11:59 PM

End  balance

0.20

0.00

0.20

0.20

0.20 0.29

0.10

0.19

0.19

0.00 0.32

0.00

0.32

0.51

4

5

6

7

8

0.51

0.15

‐0.11

‐0.33

‐0.09

0.51 0.26

0.15 0.27

0.00 0.28

0.00 0.24

0.00 0.29

0.11

0.53

0.50

0.00

0.00

0.15

0.15

‐0.26 ‐0.26

‐0.22 ‐0.33

0.24

0.29

‐0.09

0.20

No irrigation as ET  balance < min. ET 

(0.20)

Irrigate for the last  two days and no  max. ET.

No irrigation as ET  balance < min. ET 

(0.20)

No irrigation as ET  balance < 0

No irrigation as ET  balance < 0

No irrigation as ET  balance < 0

98

NLC‐100 User Manual 

Explanation

7/3

7/4

7/5

7/6

7/7

7/8

7/1

Date

7/2

Explanation

The ET balance is set to ETc = ET – Rain. As the ET balance is >= Min 

ET the program will run and use the entire ET balance.

The ETc = 0.19, which is added to the ET balance. As the ET balance  is less than Min ET the program will not run.

A lot of irrigation because there is no limit in Max ET.

As 7/2

A lot of rain. ETc becomes negative and so does the ET balance. No  irrigation.

Another day with a lot of rain.

Positive ETc and the ET balance increase, but still no irrigation.

Now we begin to irrigate again.

Example B.8. No soil holding

The program is set to run one time every day; i.e. it will if the ET balance is  greater than the Min ET. The example starts with 0.20” ET, no rain and an  empty ET balance.

99

NLC‐100 User Manual 

Numbers

1

2

3

12:01 

AM

Day Starting  balance

0.20

0.19

24 Hour Cycle

Irrig atio n

E.T.

Rain Etc.

11:59 PM

End  balance

0.20

0.00

0.20

0.20

0.20 0.29

0.10

0.19

0.19

0.00 0.32

0.00

0.32

0.51

No irrigation as ET  balance < min. ET (0.20)

100

NLC‐100 User Manual 

7

8

4

5

6

0.51

0.31

‐0.26

‐0.48

‐0.24

0.35 0.26

0.31 0.27

0.53

‐0.26 ‐0.26

0.00 0.28

0.50

‐0.22 ‐0.48

0.00 0.24

0.00 0.29

0.11

0.00

0.00

0.15

0.24

0.29

0.31

‐0.24

0.20

Irrigate for the last  two days, but only  max. ET.

No irrigation as ET  balance < min. ET 

(0.20)

No irrigation as ET  balance < 0.

Not limited by soil  holding.

No irrigation as ET  balance < 0

No irrigation as ET  balance < 0

7/1

Date

7/2

7/3

7/4

7/5

7/6

7/7+8

Explanation

The ET balance is set to ETc = ET – Rain. As the ET balance is >= Min 

ET the program will run and use the entire ET balance.

The ETc = 0.19, which is added to the ET balance. As the ET balance  is less than the Min ET the program will not run.

The ET balance will now be the sum of ETc for 7/2 and 7/3; i.e. 0.51”. 

As this is above the Max ET the program will only apply 0.35” and  the remaining 0.16” will be left in the ET balance.

Just a normal day. ET – Rain from the past day is added to the ET  balance and it irrigates.

A lot of rain. ETc becomes negative and so does the ET balance. No  irrigation.

Another day with a lot of rain. No limit in the ET balance as there is  no soil holding

Positive ETc and the ET balance increases, but still no irrigation.

101

NLC‐100 User Manual 

Example B.9. Max. hourly rain

The program is set to run one time every day; i.e. it will if ET balance is  greater than Min ET. The example starts with 0.20” ET, no rain and an  empty ET balance.

The example shows the effect of max hourly rain. If it rains more than Max  hourly rain within an hour only the Max hourly rain is used.

Options for Getting ET Data

Your controller will accept ET data from a number of sources, and the  mechanisms using the ET data to calculate irrigation aspects are identical,  regardless of input method.

102

NLC‐100 User Manual 

The NLC accepts ET data from the following sources:

Name in controller menu

Local Weather

Station

Description

Input is pulses from a weather station and tipping 

bucket (For more information turn to  on page 107)

Historic ET

Manually entered historical ET data (For more  information turn to Using Historical ET Data on page 

103)

Remote ET & Rain

Remote ET

Local WS with Alarm send

ET and rain data is received from the RealNet server.

ET data is received from the RealNet server. No rain  data received.

Same as Local Weather Station, but rain alarm  activation/de‐activation will be passed on to the 

RealNet server.

For more information turn to  on page 107 (swap in your preferred source 

for the local weather station.)

Using Historical ET Data

If you don't have a local weather station you can use historical ET data to  correct your irrigation instead.

Before you start this procedure you need to know how much water  evaporates every month of the year ‐ on a daily basis. Meaning that for  each month you'll get to enter a figure that will be used each day that  month.

103

NLC‐100 User Manual 

Your start times will be sorted by start time ‐ if the  second start time you enter is before the first one,  they will be swapped around next time you browse  the list.

Configuring for Historical ET Data

1 1. Turn the dial to ADVANCED

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display looks like this:

104

NLC‐100 User Manual 

2 Use the item selectors to select 

3. Intelliset and push the 

ENTER button. Now you'll see the following screen:

3 Select 

1. ET.

 Now the display will look like this:

4 Select

6. Device Setup.

 Now the display will look like this:

105

106

NLC‐100 User Manual 

5 Select 

1. ET Input Method.

 Now the display will look like this:

6 Select 

Historic and push the 

ENTER button.

7 Push the 

CANCEL button once to go back to the main Intelliset™  menu.

8 Select 

5. Historic Data Settings in the menu and push the 

ENTER button. Now you'll see the following screen:

NLC‐100 User Manual 

9 Use the item selectors to browse the months and set the daily ET  adjustment for each.

10 Push the CANCEL button to return to the main Intelliset™ menu.

107

108

NLC‐100 User Manual 

NLC‐100 User Manual 

Appendix C: Adding a flow sensor

The NLC can measure the flow of water in your system and react on any  unusual situation by quarantining faulty stations, stacking programs that  exceed the expected flow or even cutting off the water supply completely  if it seems that you have a leak.

This works by letting a flow sensor measure the flow on the main pipe that  feeds your system, and connecting the flow sensor to the NLC.

There are four types of flow alarms ‐ three of which can go off when  irrigating and one that is only relevant when no stations are running:

Alarm Types

Alarm Name Description

High Flow Occurs when your system is  using more gallons per  minute than your defined  threshold.

What happens?

All running programs are  halted.

Flow Deviation Occurs when your flow is  above or below a certain  percentage from the  expected flow.

Unscheduled 

Flow

Occurs when there is a flow  even when there shouldn't  be (when no stations are  running). This indicates a leak  somewhere on the pipe.

All running stations are  halted and blacklisted.

Normally open master valve 

(NOM) is activated for 

17:59:50.

109

NLC‐100 User Manual 

Alarm Name

Master Pump 

Failure (MFP)

Description

Occurs when your flow is  below a certain threshold.

What happens?

The master pump or all  running programs are  stopped, depending on your 

configuration (For more  information turn to  

Appendix C: Setting Alarm 

Actions on page 120).

Before you can take advantage of the features associated with flow sensor  input you have to connect a flow sensor and configure a few things in the  controller. The following sections walk you through the process.

Setting Alarm Thresholds

For each of the alarms described in Appendix C: Alarm Types on page 109

you must set a threshold value, and you also need to tell the controller for  how long the alarm must be on before the controller should take action.

Note: 

Setting a threshold to zero will disable the alarm. This  section describes how to enter these settings.

Setting the alarm reaction delay

1 Turn the dial to 

ADVANCED

, use the item selectors to scroll to item  number 

3. FloGuard

, and push the 

ENTER button.

Now you'll see this display:

110

NLC‐100 User Manual 

2 Choose 

2. Alarm Thresholds and push the 

ENTER button.

Now you'll see the following display:

3 Use the item selectors to select 

1. Alarm Reaction Delay.

 Now  you'll see the following display:

111

NLC‐100 User Manual 

4 Use the item selectors to set the reaction time in minutes. The  controller won't raise any sensor alarms until they have been on for  this period.

Note: 

A Master Pump Failure (MPF) will ignore this setting ‐ 

MPF alarms have a fixed delay of 30 seconds.

5 Push the 

ENTER button to save your selection.

Setting the high flow threshold

1 Turn the dial to 

ADVANCED

, use the item selectors to scroll to item  number 

3. FloGuard

, and push the 

ENTER button.

Now you'll see this display:

112

NLC‐100 User Manual 

2 Choose 

2. Alarm Thresholds and push the 

ENTER button.

Now you'll see the following display:

3 Use the item selectors to select 

2. High Flow

. Now you'll see the  following display:

113

NLC‐100 User Manual 

4 Use the item selectors to set the maximum flow in gallons per  minute. If this flow is exceeded the controller will raise a high flow  alarm.

If this alarm is activated all running programs will be halted, but the next  program will be started normally when it is scheduled. Of course, if the  next program also generates a high flow alarm it is halted too.

5 Push the 

ENTER button to save your selection.

Setting the Flow Deviation

1 Turn the dial to 

ADVANCED

, use the item selectors to scroll to item  number 

3. FloGuard

, and push the 

ENTER button.

Now you'll see this display:

114

NLC‐100 User Manual 

2 Choose 

2. Alarm Thresholds and push the 

ENTER button.

Now you'll see the following display:

3 Use the item selectors to select 

3. Flow Deviation

. Now you'll see  the following display:

115

NLC‐100 User Manual 

4 Use the item selectors to set the deviation percentage from  expected flow. The controller will raise an alarm if the flow exceeds  or falls short of the expected flow with this many percent.

If this alarm is activated all running stations will be halted and  blacklisted (marked as failed). Any programs that include failed  stations will simply skip those stations and run the next one in the  program. To clear a station you need to mark it OK on the controller 

(see Appendix C:  on page 127 for instructions.)

You can read more about the expected flow in Appendix C: Setting 

Expected Station Flow on page 121.

5 Push the 

ENTER button to save your selection.

Setting the unscheduled flow threshold

1 Turn the dial to 

ADVANCED

, use the item selectors to scroll to item  number 

3. FloGuard

, and push the 

ENTER button.

Now you'll see this display:

116

2 Choose 

2. Alarm Thresholds and push the 

ENTER button.

Now you'll see the following display:

NLC‐100 User Manual 

3 Use the item selectors to select 

4. Unscheduled Flow.

 Now you'll  see the following display:

4 Use the item selectors to set the unscheduled flow limit in gallons  per minute. This is an alarm that will be raised only when no stations  are running.You may have a minor natural leak of water in your  pipes but here you can set the maximum flow allowed when no  stations are running. 

If this alarm is activated the normally open master valve (NOM) will  be activated, and remain on for 999 minutes. It can be turned off 

just like any other station (For more information turn to Capter 4: 

Running Extra Stations in Auto Mode on page 47).

117

NLC‐100 User Manual 

Important! 

If you turn the mode selector away from 

AUTO or 

MANUAL mode the normally open master valve (NOM) will be  reset and the water will no longer be cut off from your system.

5 Push the 

ENTER button to save your selection.

Setting the master pump failure threshold

1 Turn the dial to 

ADVANCED

, use the item selectors to scroll to item  number 

3. FloGuard,

 and push the 

ENTER button.

Now you'll see this display:

2 Choose 

2. Alarm Thresholds and push the 

ENTER button.

Now you'll see the following display:

118

NLC‐100 User Manual 

3 Use the item selectors to select 

5. Master Pump Failure.

 Now  you'll see the following display:

4 Use the item selectors to set the minimum flow that must be in your  pipe if the master pump is working correctly.

You can decide whether this alarm should result in all programs to 

be halted, or all pumps and master valves should be turned off (For  more information turn to  Appendix C: Setting Alarm Actions on  page 120). The action you choose will be in effect until the next 

station gets activated (manually or by a program.)

5 Push the 

ENTER button to save your selection.

119

NLC‐100 User Manual 

Setting Alarm Actions

The only flow alarm for which you can decide the action is the master pump  failure alarm ‐ you get to decide whether this should cause all programs to  be halted or all pumps and master valves to be shut down.

Configuring alarm action for MPF

1 Turn the dial to 

ADVANCED

, use the item selectors to scroll to item  number 

3. FloGuard,

 and push the 

ENTER button.

Now you'll see this display:

2 Choose 

3. Action Configuration.

 Now you'll see the following  display:

120

3 Use the item selectors to choose between:

NLC‐100 User Manual 

Pumps/MVs:

All pumps and master valves will be shut down when  an alarm goes off. The programs will still be finished even if the  pumps are turned off in order not to interrupt the irrigation  schedule since an MPF alarm will be cleared next time a program  has to start.

Programs:

All running programs will be shut down when an alarm  goes off.

4 Push the 

ENTER button to save your selection.

Setting Expected Station Flow

In order to be able to calculate when the current flow is deviating from the  expected flow, the NLC needs to know how much flow you expect each  station to pull.

To teach the controller about the expected flow you can either enter a  value for each station or run the automated "learn flow" feature that will  assess the flow for each station in turn.

Note: 

Please be advised that the system will not be able to  handle a flow higher than 9999 gallons per minute.

Entering expected flow for a station

1 Turn the dial to 

ADVANCED and select 

2. FloStack

.

Now you'll see the following display:

121

NLC‐100 User Manual 

Scroll down and select 

2. Expected Flow by pushing the ENTER button. 

Now you'll see a scrollable list of stations and their expected flow in gallons  per minute:

122

2 Use the item selectors to locate the station you wish to configure  and push the 

ENTER button.

3 Now you can set the expected flow using the item selectors and save  your setting by pushing 

ENTER again.

If the above procedure seems to tedious there's an easier way ‐ you can let  the NLC asses the expected flow for each station. If you choose this  approach the controller will run all stations in turn for a fixed duration,  measure the flow for each of them and save the flow as the expected one.

NLC‐100 User Manual 

Running the "learn flow" feature

1 Turn the dial to 

ADVANCED and select 

2. FloStack.

Now you'll see the following display:

2 Scroll down and select 

3. Learn Flow by pushing the 

ENTER button. Now you'll see the following display:

3 Use the item selectors (both up, down, right and left) to choose a  station to start from and set the run time for each station. All  stations will be run for the same period of time.

The NLC measures the flow continuously while the station is running  the "Learn Flow" feature but only the last measurement is used. The  last measurement is likely to be the most accurate one as the flow  will have stabilized after running for a few minutes.

123

NLC‐100 User Manual 

4 Push 

ENTER to start the test. Now you'll see the starting the test at  the station you selected (ST1) and running it for the selected  duration (3 minutes):

5 When a station is done running its measured flow will be stored as  the expected flow for that station. Pushing 

CANCEL at any time will  abort the "learn flow" feature but the stations measured so far are  still saved. This means that you don't have to measure all stations in  one sitting ‐ simply re‐run the "learn flow" feature with a new "Start  from" setting to finish what you may have cancelled earlier.

Viewing the Current Flow

Given that you have configured your flow sensor correctly, the NLC lets you  see the real time flow directly in the controller display:

1 Turn the dial to 

ADVANCED

, use the item selectors to scroll to item  number 

3. FloGuard,

 and push the 

ENTER button.

Now you'll see this display:

124

NLC‐100 User Manual 

2 Select 

4. Flow Sensor Setup

, and push the 

ENTER button.

Now you'll see this display:

3 Select 

3. Current Flow Pulses and GPM and you'll see the current  system flow in both pulses per second and gallons per minute:

125

NLC‐100 User Manual 

Note: 

The NLC can measure correctly up to a flow of 250 pulses  per second. If your flow exceeds this you should use a sensor  that has a higher "water amount per pulse" ratio. However, a  higher frequency is preferred over a lower one, as it provides  the most accurate measuring, so in an ideal world your  frequency closes in on 250 pulses per second without ever  exceeding it. 

Inspecting and Toggling Station Status

Stations can be blacklisted if the controller suspects that they are faulty 

and cause deviations in the expected flow (For more information turn to  

Appendix C: Setting the Flow Deviation on page 114). However, the 

controller might blacklist an innocent station since all stations that are  running when the deviation takes place are blacklisted. So, to enable these  stations again you need to toggle their status from 

Failed to OK

.

Tip: 

Since blacklisted stations are simply skipped when running  programs that require them, marking a station as failed is an  excellent way of taking a single station out of use without  having to redo the program all together. This can be useful if  you just need to check or replace the station in the field.

126

NLC‐100 User Manual 

This procedure explains how you toggle station status:

Managing station status

1 Turn the dial to 

ADVANCED

,  use the item selectors to scroll to item number 3. FloGuard, and push the ENTER button.

Now you'll see this display:

2 Select 

1. Station Status by pushing the 

ENTER button. Now  you'll see a scrollable list of stations and their status ‐ Failed or OK:

3 If you wish to toggle the status of a station, locate it with the item 

selectors and push the 

ENTER button.

127

128

NLC‐100 User Manual 

Tip: 

Instead of browsing through the entire list of stations you  can use the 

STATION button to browse only failed stations.

Using the item selectors again, you can toggle the station between 

OK and 

Failed status.

4 Push the 

CANCEL button to exit the menu.

NLC‐100 User Manual 

Appendix D: Moisture sensors

With moisture sensors your controller can learn the exact moisture levels  in the soil and adjust irrigation based on this knowledge.

The Role of Moisture Sensors

Adding moisture sensors to your NLC takes the guesswork out of irrigation  and adds a new level of intelligence to the picture ‐ you now enjoy "Total 

Cycle Management":

1 Calculate your irrigation run times based on local ET and Rain

2 Communicate ‐ get  runtimes and system status via the Internet

3

Validate runtime scheduling based on feedback from the soil

129

NLC‐100 User Manual 

Let's examine the three components of Total Cycle Management in turn.

Calculate

When planning irrigation you look at the best evapotranspirational (ET)  data you have available. In descending order of accuracy you may have  access to one or more of the following:

• Data from a local weather station.

• Real‐time ET data from an off‐site weather station.

• Daily weather reports from an off‐site weather station.

• Historical weather data for your area.

In addition you know about the soil type, vegetation and other factors that  should affect your irrigation planning, but even the best planning is still, in  essence, guesswork, as you don't know for sure how the soil is responding.

Communicate

With an intelligent irrigation controller like the NLC you get a lot of help in 

correcting your calculations along the way. A variety of alarms (For more  information turn to Capter 4: Alarms on page 53) can be raised and many 

will lead to your irrigation schedules being adjusted to the new conditions.

For example, if it rains heavily, the NLC won't blindly keep irrigating as you  may have told it to.

The NLC logs everything elaborately and even lets you view real-time data in the web based interface. With this knowledge you can re‐adjust your calculation,  but still, an important piece is missing from the puzzle.

130

NLC‐100 User Manual 

Validate

To validate your calculations and the feedback the system has given you  there is no way around measuring the exact levels of moisture in the  ground.

By adding moisture sensors to the NLC you are now full circle. Irrigation can  now be adjusted automatically based on the data flowing from your  moisture sensors, and long term you can adjust your schedules according  to what you learn from the full circle irrigation scheme, gradually refining  your irrigation schedules to perfection.

When setting up moisture sensors with the NLC, you tell the controller  which soil type you are measuring, and then the NLC will pull in data every 

10 minutes, and you are allowed to configure precisely how the controller  should react to this data ‐ this happens as fine grained as on a per‐program  basis:

• Set limits for how dry the soil should be before irrigating and how  moist it must be before irrigation is prevented.

• Determine whether or not the collected data should affect current  irrigation directly, or if the data should just be collected for  schedule refinement later on.

The moisture sensors also work in conjunction with the regular ET  mechanism and affects the amount of water assigned to irrigation moving  forward. The range of ET adjustment can be from zero to two times the  daily ET, meaning that a very dry soil can result in ET being doubled and a  very moist soil can bring the ET for the following day to zero.

You determine per program how much the controller can adjust the ET by  setting a value between 0 and 100%, a 100% being double from normal ET 

(For more information turn to  Appendix D: How irrigation is adjusted by 

moisture sensors on page 132.)

131

NLC‐100 User Manual 

How irrigation is adjusted by moisture sensors

Each program can accept input from a moisture sensor and its input can be  used for the following:

• Allow irrigation if the moisture level is low enough

• Raise an alarm if the moisture level is too low

• Prevent irrigation if the moisture level is too high

• Optionally adjust the ET balance

Note: 

Each moisture sensor can control multiple programs and  its input can be interpreted differently by different programs.

Here is how you configure your programs to use a moisture sensor:

1 Turn the dial to

ADVANCED

PAUSE/

RESUME

STOP

MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display looks like this:

132

NLC‐100 User Manual 

2 Use the item selectors to select

3. Intelliset and push the

ENTER button. Now you'll see the following screen:

3 Select

2. Moisture and push the

ENTER button. Now the display looks like this:

133

NLC‐100 User Manual 

4 Select the first option:

1. Moisture program settings and push the

ENTER button. Now the display looks like this:

134

5 Now, using the item selectors, set the values for all seven columns:

Column

Pgm

Sens

Allow

Prevent

Alarm

Ctrl

Reg

Description

The program to assign a moisture sensor to.

Which sensor to assign.

The lower threshold for when irrigation will be allowed ‐ e.g. 

5% means that irrigation will be allowed as long as the  moisture readings are below 5%.

The higher threshold for when irrigation will be prevented ‐  e.g. 30% means that irrigation will be prevented if the moisture  readings are 30% or higher.

The lower threshold for when an alarm will be raised.

Set to Yes or No depending on whether you want the moisture sensors to control your Irrigation. If irrigation is prevented due to  high moisture readings, ET for the following  day will be increased.

A percentage with which the ET will be adjusted. 0% means no  adjustment and 100% means that the ET will be as much as  doubled for the following day.

6 Push the

ENTER button to save your configuration.

NLC‐100 User Manual 

7 Repeat steps four and five for each program you wish to assign a  moisture sensor to.

Once you have completed all the procedures in this section, your system  should be up and running, utilizing moisture sensor readings and adjusting  irrigation accordingly.

How moisture sensor input affects ET

The NLC can handle single moisture sensor via the external RS232 port and  an additional external RS232/RS485 (SMI‐100) converter. The controller  can handle up to 10 moisture sensors on a multi drop line.

The moisture sensor is able to allow or prevent irrigation and/or adjust ET  on specific programs dependent on the actual moisture and the setup. All  the setup can be done at the controller and on the WEB. It is also possible  to view the actual moisture level both on the controller and on the WEB.

The moisture sensors may be set up to simply allow or prevent irrigation. 

The irrigation is still controlled by water days, WB or ET, start times, etc. 

The sensor just acts as a switch for one or more programs.

More powerfully, the moisture sensor is also able to adjust the daily ET,  which is added to the ET balance corrected for rain for each program. The  principle is that high moisture shall reduce the ET applied to the ET balance  and low moisture shall increase the ET applied to the ET balance. With full  regulation the adjusted ET shall vary between 0 and double the amount of  daily ET. The regulation is individual per program.

Abbreviations

Factor %

Term Description

A user definable regulation factor between 0 and

100%. Set to 0 means no regulation. Set to 100%  means full regulation.

100% regulation when wet No ET is added to the balance.

135

NLC‐100 User Manual 

Term Description

100% regulation when dry 2x the ET is added to the balance.

Wet At or near field capacity.

Dry

Optimal

VSM

ETm

ET

At or near permanent wilt point.

The target balance between soil and climate ET.

The actual volumetric soil moisture.

Moisture adjusted ET and corrected for rain and added to ET balance.

ET for the prior 24 hour period.

Rain Rain for the prior 24 hour period.

VSM ranges for the different soil types

Soil type

Standard

Sand

Loam

Clay

0

2

6

15

VSM(dry)

49

22

36

50

VSM(wet) VSM(Optimal)

25.5

12

21

32.5

The following examples show 7 days with various daily ET and rain in  combination with start off of dry, wet or optimal soil condition with 0%, 

50% or 100% regulation. The examples have the following common  conditions:

• Soil type loam. Root zone 4”. This means the VSM for dry, optimal  and wet corresponds to 0.24”, 0.84” and 1.44” of water.

• The first irrigation period begins with ET=0.20, Rain=0.00”, ET  balance = 0.00”.

• The irrigation program runs every day if ET balance is above 0.00” 

(no minimum/maximum ET defined.)

136

NLC‐100 User Manual 

• Allow and prevent irrigation based on the moisture is not used.

• The water applied by irrigation and rain reach the root zone the  same day.

ET

50

50

100

100

100

0

0

0

50

Factor % VSM %

6 (dry)

21 (optimal)

36 (wet)

6 (dry)

21 (optimal)

36 (wet)

6 (dry)

21 (optimal)

36 (wet)

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.30

0.20

0.10

0.40

0.20

ETm

0.20

0.20

0.20

0.00

Example D.1. Dry start condition (stress point)

Soil moisture starts at 0.24”

137

NLC‐100 User Manual 

138

We start with 0.20” ET and no rain the first day. The soil is dry, but we have no regulation. Thus the ETm = ET. Every day the ET balance = ETm (ET) – Rain. 

There is no irrigation on 7/5 as the ET balance is negative. 

The result is that we start out with a dry soil and we will keep a dry soil. The  moisture content in the soil varies over the day as the irrigation falls in the  night (increase soil moisture) and during the day the ET dries out the soil. 

The example shows that most of the days the soil moisture is below the  permanent wilting point at the end of the day.

NLC‐100 User Manual 

We start with 0.20” ET and no rain the first day. The soil is dry, and we have 50% regulation. Thus the ETm will be regulated up by 50% from the collected ET  in the beginning and as the soil moisture reaches the nominal level the ETm  is regulated less. The trend shows the soil moisture is growing until it  reaches the  optimum level.

139

NLC‐100 User Manual 

This shows the same tendency as the 50% regulation, just that the  regulation of the soil moisture is far more aggressive.

Example D.2. Optimal start condition

Soil moisture starts at 0.84”

140

NLC‐100 User Manual 

In this case the soil moisture was in balance when we started and it is kept in balance.

141

NLC‐100 User Manual 

142

The regulation has very little influence as the soil moisture is in balance and  we just deviate slightly from the nominal value.

NLC‐100 User Manual 

Same as with 50%

Example D.3.Wet start condition (field capacity)

Soil moisture starts at 1.44”

143

NLC‐100 User Manual 

144

We start with 0.20” ET and no rain the first day. The soil is wet, but we have no regulation. Thus the ETm = ET. Every day the ET balance = ETm (ET) – Rain. 

There is no irrigation on 7/5 and 7/13 as the ET balance is negative. The  result is that we start out with a wet soil and we will keep a wet soil.We  even keep the  moisture above the field capacity, which means most of the irrigation is waisted.

NLC‐100 User Manual 

The soil will dry towards the nominal value over time. It will still irrigate,  but with less ETm than the collected ET. Using prevent irrigation above a  certain level would avoid irrigation when it is very wet.

145

NLC‐100 User Manual 

146

The same picture as the 50% regulation just that the progression towards  the nominal value is much faster.

How irrigation is adjusted by moisture sensors The same results can be  drawn for the other soil types.The only difference is the VSM range.

Min and max for ET come into play when the system starts to use the ET  balance; i.e. after the moisture correction, which is on what we add to the 

ET balance. Max hourly rain is during the day when we collect rain. Soil  holding is the maximum that the ET balance can go negative.

Soil moisture starts at 0.24”.

NLC‐100 User Manual 

Compared to the similar example in the beginning the minimum ET of 0.15”  avoids the small amount of irrigation on 7/4 and 7/14.

147

NLC‐100 User Manual 

148

In the example the Allow irrigation is set to 0.34” and Prevent irrigation is set to

1.34”.Thus the irrigation is prevented until the soil moisture drops below 

0.34”. At that point the ET balance is large and the first coming days  irrigation will increase the soil moisture to above prevent level.The next  five days the soil moisture will drop due to ET until it again allows irrigation. 

In the next period it will not increase above the prevent and  start settle at the optimum.

NLC‐100 User Manual 

This example has the same allow and prevent settings as the previous, but instead of ET controlled irrigation as water budget program is used.The water budget  program is set with start times at 1 AM, 2 AM, 3 AM, 4 AM, 5 AM and 6 AM. 

Each start apply 0.15” water and it is assumed this is in the soil the  following hour.

The result is again that the soil moisture drops until it is below 0.34” and  then on 7/3 the controller irrigates 6 times 0.15”.The next day it irrgates 3  times 0.15” until it reach the 1.34”.The following days the soil dries out and  it all repeates from 7/10.

149

150

NLC‐100 User Manual 

NLC‐100 User Manual 

Appendix E: Changing Station Run 

Sequence and Mapping

Normally stations in a program will be run in the order indicated by their station ID numbers (

For more information turn to Capter 3: Configuring Irrigation 

Programs on page 18), but you can circumvent this by assigning sequence 

numbers to stations instead.

The typical scenario if when you want to add a station to an existing  installation ‐ instead of this station always being run as the last one due to  its high ID number, you can "merge" it into the middle of the pack by using  sequence numbers.

Example E.1. Putting a new station in the middle of the run chain

Consider a scenario where you have 40 stations with ID numbers from 1 to 

40 placed in the terrain.You want to add number 41 but you would like it  to be run after station 20 instead of in the end of a program cycle. To  achieve this you would alter the sequence number for ST41 to 21:

Normal run  sequence

ST1

ST2

St3

...

ST20

ST21

ST22

...

ST39

ST40

ST41

Run sequence after changing the sequence  number for ST41 to 21

ST1

ST2

St3

...

ST20

SY41

ST21

...

ST38

ST39

ST40

151

NLC‐100 User Manual 

If station run sequences are changed, this will show when you are assigning stations to a program - if you changed the sequence like in the example above,  scrolling through the station list you would see ST41 appear right after 

ST20 in the list.

Note: 

In all other places (station test, expected flow lists, etc.)  stations are listed according to station ID and not to run  sequence.

The following two procedures show you how to alter and reset station run sequences.

Changing the station run sequence

1

Turn the dial to

ADVANCED

, use the item selectors to scroll to item number

6. Station Run Sequence & Mapping,

and push the

ENTER button.

Now you will see this display:

2 Select

1. Program Station Run Sequence

. Now you will see the following display:

152

NLC‐100 User Manual 

3 Select

1. Edit and push the

ENTER button.

Now you will see this display:

4 Use the item selectors to select the station you wish to re‐arrange  and change its sequence number.

5 Push the

ENTER button to save your sequences.

Resetting station run sequences

1 Turn the dial to

ADVANCED

, use the item selectors to scroll to item number

6. Station Run Sequence & Mapping

, and push the

ENTER button.

Now you will see this display:

153

154

NLC‐100 User Manual 

2

Select

1. Program Station Run Sequence.

following display:

Now you will see the

3 Select

2. Reset to factory default and push the

ENTER button.

Now you will see this display:

NLC‐100 User Manual 

4 Push the

ENTER button to acknowledge that you're resetting the sequence numbers, or

CANCEL to exit.

Changing Station Output Mapping

In addition to changing the station run sequence, you may alter the  mapping between station names and physical stations, meaning that  station 1 can be re‐mapped to not activate the valve connected to terminal 

1, but an arbitrary valve.

This is how it is done:

Changing Station Output Mapping

1 Turn the dial to

ADVANCED

, use the item selectors to scroll to item number

6. Station Run Sequence & Mapping

, and push the

ENTER button.

Now you will see this display:

2 Select

2. Station Output Mapping and press the

ENTER button. Now the display will look like this:

155

NLC‐100 User Manual 

3 Select

1. Edit and press the

ENTER button. Now you will see the following display:

4 Use the item selectors to map station names to physical output terminals and press the

ENTER button to save your mapping.+

In case you want to reset to the factory defaults of stations names mapped directly to corresponding terminal IDs, follow this procedure:

Resetting Station Output Mapping

1 Turn the dial to

ADVANCED

, use the item selectors to scroll to item number

6. Station Run Sequence & Mapping

, and push the

ENTER button.

Now you will see this display:

156

NLC‐100 User Manual 

2 Select

2. Station Output Mapping and press the

ENTER button. Now the display will look like this:

3 Select

2. Reset to factory default

. Now you will see the following display:

4 Push the

ENTER button to acknowledge that you are resetting all mappings, or

CANCEL to exit.

157

158

NLC‐100 User Manual 

NLC‐100 User Manual 

Appendix F: Using Simple Flow 

Management 

The NLC allows for simple flow management by comparing the current flow to system capacity and preventing too many stations from running at once.

Configuring for Flow Management

Setting up your system for flow management only involves two things:

1 Defining the expected flow for your stations. For more information  turn to  Appendix C: Setting Expected Station Flow on page 121.

2

Set the maximum system capacity. For more information turn to  

Appendix F: Setting the System Flow Capacity on page 160.

How the Flow Management Works

Whenever a station is about to start, the NLC will try to determine whether  the system has sufficient capacity to start the station by doing a little  calculation. A station can be started if:

(Required Capacity + Capacity in Use) <= Total Capacity

In plain words: the capacity required by the station plus the capacity  already used must not exceed the total system capacity.

The required capacity and the capacity in use is determined from the 

station flow, whether entered or learned (For more information turn to  

Appendix C: Setting Expected Station Flow on page 121).

159

NLC‐100 User Manual 

If a station can not be started it will be queued in "pending" state. On the  controller this will appear as "Waiting", just as paused stations. However,  pending stations have a higher priority than others next time the NLC frees  some capacity. (This is known as the stacking mechanism.)

There are a couple of things to keep in mind when using flow management:

• When running in AUTO mode, manually started stations will  overrule the flow management and ignore the higher priority of  pending stations. Manually started programs will obey the flow  management though.

• The entire concept of flow management is ignored when running in 

MANUAL mode.

• When pausing a program the NLC will release the capacity to flow  management and thus the program might go into "pending" state  when resumed if the capacity is used up by other stations.

Setting the System Flow Capacity

If you tell the NLC about the flow capacity of your pipes, the controller can automatically queue up stations that would exhaust the capacity by starting. Here's how you enter the flow capacity at the controller:

1 Turn the dial to

ADVANCED and select

2. FloStack

.

Now you'll see the following display:

160

NLC‐100 User Manual 

2 Select

1. System Flow Capacity and you'll see this display:

3 Use the item selectors to set the system flow capacity and push the

ENTER button to save your setting.

Important

Leaving the System Flow Capacity at zero GPM means that the setting  won't be used to correct which stations are started.

161

162

NLC‐100 User Manual 

NLC‐100 User Manual 

Appendix G: Defining a custom  irrigation period

You can change the standard irrigation window in the NLC that runs from 12:00 AM to 12:00 AM. This has two effects:

1 The entire water cycle will start when your irrigation period starts. 

If this is different from 12:00 AM, please be aware that:

• Programs will start running on the first start time after your  irrigation period starts. This can potentially lead to a bit of confusion  where programs leap into days you wouldn't think they should be  running, or start running before they normally would.

Important! 

The irrigation period normally starts at midnight,  but if you move the start into the PM window, your period  starts earlier. Moving the start into the AM window will start  the period later.

Example G.1. Skewed days with custom irrigation periods

Consider a program with four start times: 02:00 AM, 05:00 AM, 06:00 PM  and 11:00 PM that runs on odd days.

If your irrigation period starts at 08:00 PM and runs to 08:00 PM, here's  how the program could run:

163

NLC‐100 User Manual 

Date

September 3.

02:00 AM

September 3.

05:00 AM

September 3.

06:00 PM

September 3.

11:00 PM

...

...

Start time

September 2.

11:00 PM

Action

Runs despite the even date - your irrigation period has started earlier  than midnight.

Runs as expected.

Runs as expected.

Runs as expected.

Will not run despite the odd date ‐ your  irrigation window has  closed.

...

• All ET calculations are based on the irrigation period, be it the  standard one or your custom period.

2 You can define a "non‐water" window by not letting the period span 

24 hours. If you define the start to 06:00 PM and the end to 08:00 

AM no programs or stations will be started between 08:00 AM and 

06:00 PM.

Note: 

You can still run both stations and programs manually in  the non‐water window.

Programs that try to start in the non-water window will generate an alarm. And if a program is running when the non‐water window starts the program is halted 

and an alarm is raised. For more information turn to Chapter 4: Alarms on  page 53.

Here is how you actually define the irrigation period at the controller:

164

NLC‐100 User Manual 

Configuring the Irrigation Period

1 Turn the dial to

ADVANCED

, use the item selectors to scroll to item number

4. Irrigation Period

, and push the

ENTER button.

Now you'll see this display:

2 Use the item selectors to set the start and end time and push the

ENTER button to save your settings.

165

166

NLC‐100 User Manual 

NLC‐100 User Manual 

Appendix H: Advanced irrigation: 

Misting, Cycle and Soak

The NLC lets you go beyond regular irrigation and build misting and "Cycle 

& Soak" programs.

Important! 

The basics are the same as when building a regular 

irrigation program, so make sure to read 

Chapter 3: Configuring 

Irrigation Programs

 on page 

18

.  and pay particular attention to 

Chapter 3: Setting Start Times

 on page 

28

.

How is This Different from Regular Programs?

Misting and "Cycle & Soak" programs are configured the same way as 

regular programs (see Chapter 3: Configuring Irrigation Programs on page 

18 for a walk‐through), except for one point: The program start times have 

a more elaborate configuration.

In addition to start time, you configure an end time and a cycle count for  how often you want the program repeated within this time frame. The  controller will then "even out" the repeats within your time frame, leaving  identical breaks between them.

So, if the total run time for your program is ten minutes and you configure  the program to run three times between 10:00 AM and 11:00 AM, your  program will run at 10:00, 10:25 and 10:50, leaving 15 minute breaks at 

10:10 and 10:35.

167

NLC‐100 User Manual 

The terms "Misting" and "Cycle & Soak" refer to two variants of this  concept:

Misting: typically describes a program that runs its stations for a  very short time ‐ run times are in seconds.

Cycle & Soak: typically describes a program that uses longer run  times ‐ measured in minutes.

Both will run a number of cycles per start, whereas a normal program will  only run once per start.

When the NLC Alters Your Program

There are a number of scenarios where the NLC will reduce the number of  repeats in a program start:

Program was paused

If a program has been paused the NLC will not aggregate the cycles that  should have been run in the pause ‐ these cycles are just ignored and the  program continues at the point it would be at had it not been paused.

Maximum system capacity met

If a program tries to run a cycle when the maximum system capacity is  reached, this cycle is just dropped.

ET adjustments

If ET adjustments have dictated that you can irrigate less then normally  today, reducing the number of cycles can be the outcome.

168

NLC‐100 User Manual 

If the number of cycles is reduced, a Repeat alarm is raised. (See Chapter 4: 

Alarms on page 53 for details.)

How to Configure for Misting or Cycle & Soak

A misting program will typically run a number of stations for just a few seconds at a time, and then add longer breaks between the program start times.

Here's an example of a simple misting program:

Station

ST1

ST2

ST3

ST4

ST5

...

Run time

0:00:05

0:00:08

0:00:15

0:00:06

0:00:08

...

Note: 

Since the NLC will start stations every ten seconds you  might experience short breaks between starts in a misting  program. For example you'll see short breaks of between five  and two seconds in the program above.

For run time over four minutes, the end time is aligned to ten  second slots too, so for example a run time of 0:05:13 will run  for 0:05:20.

And here's a program that start at various frequencies in different time intervals:

Full misting program example

169

NLC‐100 User Manual 

#

Start #

1

2

3

Details

Start time: 08:00 AM

End time: 09:00 AM

Count: 3

Repeat duration: 10 minutes

Start time: 09:00 AM

End time: 10:00 AM

Count: 4

Repeat duration: 10 minutes

Start time: 10:00 AM

End time: 11:00 AM

Count: 5

Repeat duration: 10 minutes

Irrigation will start @

• 08:00:00 AM

• 08:25:00 AM

• 08:50:00 AM

• 09:00:00 AM

• 09:16:40 AM

• 09:33:20 AM

• 09:50:00 AM

• 10:00:00 AM

• 10:12:30 AM

• 10:25:00 AM

• 10:37:30 AM

• 10:50:00 AM

Finally, let's see how you go about creating a misting program on the  controller ‐ let's say you want to configure the first start time in the  example program above ‐ here's how you would do it:

The first thing you need to do in order to use the misting features is to  enable them:

Enabling Misting

1 Turn the dial to

ADVANCED

170

NLC‐100 User Manual 

PAUSE/

RESUME

STOP MANUAL

OFF

RAIN OFF

RAIN ALARM STATUS

VIEW ALARMS

VIEW ET & RAIN

VIEW MOISTURE SENSOR

SETUP SENSORS

SOLENOID AMPS

AUTO

SET DATE & TIME

PROGRAM

RUN TIME

WATER DAYS

START TIME

WATER BUDGET / ET

PROGRAM STATUS

ADVANCED

Now the display looks like this:

2 Use the item selectors to scroll to item number

8. Feature Manager, and push the

ENTER button.

Now you'll see this display:

171

NLC‐100 User Manual 

3 Select

1. Ena/Dis Cycle and End Time

.

Now you'll see this display:

4 Use the item selectors to select

Enable and push the

ENTER button to save your setting.

And then you're ready to configure the program:

Setting the Start Times With Count and End Time

1 Create your program as explained in Chapter 3: Configuring 

Irrigation Programs on page 18, but when you get to Chapter 3: 

Setting Start Times on page 28, swap that part out for the 

instructions in this procedure instead.

172

NLC‐100 User Manual 

2 Use the item selectors to navigate to the program you wish to adjust  the start times for and push the 

START TIMES button.

Now you'll see the following display:

3 Use the item selectors to locate the one of the four runs you wish to  set a start time for, and push the 

ENTER button.

Now the cursor will jump to the right, letting you set the start time:

4 Use the item selectors to set the start time to 08:00 AM and push  the right arrow to jump to the cycle  field

(Cyc)

.

5 Use the item selectors to set the count to four and push the right  arrow to jump to the end time field (

End

).

Note: 

As soon as you enter the End field, the controller will set the  default end time to 

(total run time * count) + start time

= 08:04

.You must extend the end time in order get the breaks in  between the four cycles:

173

174

NLC‐100 User Manual 

If you cut the end time shorter, one of two things will happen, depending  on which type of program you are dealing with:

• • If you are handling a water budget based program: The

Cyc field will automatically decrease in order to fit in the cycles possible before the  end time ‐ you'll see it when you have saved the start time.

• • If you are handling an ET controlled program: No adjustments are  made to the number of cycles. The fact that ET may decrease the  run time of your cycles, you may still be able to fit in your number  of cycles even though you lower the end time.

6 Set the end time to 09:00 and push the

ENTER button to save your settings

- now the cycles will be evenly spread out in the hour between 08:00  and 09:00.

Note: When running this program, the controller still considers 

the program to be running, even though it is waiting between  two cycles ‐ here's what the display will look like right after the  first cycle in the first run:

NLC‐100 User Manual 

Things to Keep in Mind

When using misting or cycle & soak programs, there are a number of things to consider that don't apply to regular programs:

• If you're using ET: Each cycle still obeys the water budget dictated  by ET. This means that each cycle might have to run for so long that  the time frame for the start time doesn't have enough room to fit in  all the cycles. In this case the number of cycles is cut down  adequately. The "cut out" irrigation is added to tomorrow's ET  figure.

• If you're using a maximum system capacity (For more information  turn to  Appendix F: Using Simple Flow Management on page 159) a 

cycle might be unable to run if the maximum capacity is reached. If  the program is ET controlled, the "cut out" irrigation is added to  tomorrow's ET figure.

• If you pause a misting program the cycles that should have taken  place during the pause are dropped in order to fit the total number  of cycles in the program run time window. If the program is ET  controlled, the irrigation that is lost on this account is added to  tomorrow's ET figure.

• You should ensure that flow limits or reaction delay is set to  consider the "on/off" nature of misting programs in order to avoid  false alarms. Ideally you should use a separate pipe system without 

175

176

NLC‐100 User Manual 

flow sensors for misting programs. For more information turn to  

Appendix C: Setting Alarm Thresholds on page 110.

• The NLC can handle up to five station starts within ten seconds, so  you should avoid starting more than five stations at once, or you will  start seeing alarms.

NLC‐100 User Manual 

Glossary

Term

Cable

Two‐wire

Wire

Description

Two wires surrounded by insulation.

Synonym for a cable.

An individual copper wire.

177

178

NLC‐100 User Manual 

NLC‐100SH Installation and troubleshooting 

179

NLC‐100SH Installation and troubleshooting 

180

NETAFIM USA

5470 E. Home Ave.

Fresno, CA 93727

CS 888 638 2346 www.netafimusa.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents