The Axing EOC 1-01 enables you to feed IP data signals, such as internet via a router, into an existing coaxial antenna distribution system. This eliminates the need for new network cables. The transmission takes place in the low-attenuation return channel frequency range of 2...68 MHz, allowing for transmission distances of up to 700 m, depending on the quality of the coaxial cable.
advertisement
EoC 1-01
Ethernet over Coax
Betriebsanleitung
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
Inhaltsverzeichnis
2 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
Warnhinweise
NICHT in der Nähe von Wasser oder in feuchten Räumen, z. B. feuchten Kellern oder in der Nähe von
Schwimmbecken verwenden.
Das Gerät NICHT im Freien verwenden. Alle Verbindungen müssen sich innerhalb eines Gebäudes befinden.
Gerät von Feuchtigkeit, Staub oder ätzenden Flüssigkeiten fernhalten.
Das Gerät NICHT während eines Gewitters installieren, verwenden oder warten. Bei Gewitter besteht die
Gefahr eines Stromschlags.
AUSSCHLIESSLICH geeignete Zubehörteile an das Gerät anschließen.
Sicher stellen, dass alle Kabel an den korrekten Port angeschlossen sind.
Ethernet-, Antennen- und Stromkabel sorgfältig verlegen, so dass niemand darauf treten oder darüber stolpern kann.
Die Lüftungsschlitze des Geräts NICHT abdecken, da eine ungenügende Luftzufuhr zur Beschädigung des
Geräts führen kann.
KEINE Gegenstände auf das Gerät legen. Das Gerät so platzieren, dass NIEMAND auf das Gerät treten kann.
Vor Wartung oder Demontage immer das Ethernet- und Stromkabel vom Gerät trennen.
Bei Beschädigung Stromzufuhr zum Gerät unterbrechen.
KEINE Reparaturversuche unternehmen. Kontaktieren Sie Ihren Händler, um ein neues Gerät zu bestellen.
Das Gerät oder die Einheit NICHT öffnen. Nach dem Öffnen oder Entfernen von Verkleidungen bestehen
Risiken, z. B. durch gefährlich hohe Spannung. Dieses Gerät ist AUSSCHLIESSLICH durch qualifiziertes
Servicepersonal zu warten oder zu deinstallieren. Kontaktieren Sie Ihren Händler für weitere Informationen.
Hiermit erklärt die AXING AG, dass die gekennzeichneten Produkte den geltenden
Richtlinien entsprechen. Sie finden die vollständige EU-Konformitätserklärung zum
Download indem Sie auf www.axing.com im Suchfeld den Artikel
WEEE Nr. DE26869279 | Elektrische und elektronische Komponenten nicht mit dem
Restmüll, sondern separat entsorgen.
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
3
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
1. Produktbeschreibung
1.1. Lieferumfang
EoC 1-01
1 x EoC 1-01 Ethernet over Coax Modem
1 x Netzwerkkabel 1,5 m
1 x Stromversorgungskabel mit Eurostecker
1 x CFA 8-00 Abschlusswiderstand
1 x Bedienungsanleitung
EoC 1-00
2 x EoC 1-01 Modem
2 x Netzwerkkabel 1,5 m
2 x Stromversorgungskabel mit Eurostecker
2 x CFA 8-00 Abschlusswiderstand
2 x Bedienungsanleitung
Lieferbares Zubehör:
∂ IEC-Anschlusskabel 1,5…10 m BAK 150-80 – 999-80
∂ Modem Anschluss Kabel 1,5…10 m MAK 150-80 – 999-80
∂ Adapter
∂ Adapter
∂ Einspeiseweiche
4 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
1.2. Verwendungsbereich
Das EoC 1-01 Modem ermöglicht die Einspeisung von IP-Datensignalen wie z. B. des Internets über einen
Router in eine vorhandene koaxiale Antennenverteilung, wie z. B. SAT-ZF-, DVB-T, BK- oder Kopfstellen-
Verteilsystemen (in Stern- oder Baumverteilung).
Der Vorteil einer Ethernet over Coax Lösung ist, dass keine neuen Netzwerkkabel verlegt werden müssen. Die
Übertragung erfolgt im dämpfungsarmen Rückkanal-Frequenzbereich von 2…68 MHz. Je nach Güte des koaxialen Kabels können Übertragungsstrecken von bis zu 700 m realisiert werden.
Die Einspeisung erfolgt über den rückkanaltauglichen terrestrischen Eingang eines SAT-Multischalters, den terrestrischen Eingang einer Antennenverteilstruktur oder über eine rückkanaltaugliche Antennendose im
Verteilnetz.
Einspeisung über den rückkanaltauglichen terrestrischen Eingang eines SAT-Multischalters
An rückkanaltauglichen Antennendosen (z.B. AXING-Antennendosen stehen dann Internet- bzw. andere
An einem EoC-Modem können zwei netzwerkfähige Geräte an den LAN-Anschlüssen angeschlossen werden.
Das IP-Netzwerk kann auf bis zu 64 EoC-Geräte ausgebaut werden.
Alle an den EoC-Modems angeschlossenen Geräte können untereinander kommunizieren. Es werden Daten ausgetauscht, Netzwerkspiele übertragen, oder es kann auf einen zentralen Netzwerkdrucker zugegriffen werden. Zur Überwachung von Häusern, Innenräumen etc. lässt sich auch eine IP-Überwachungskamera über ein EoC Modem betreiben.
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
5
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
1.2.1. Peer-to-Peer-Mode
Die EoC 2-01 Modems kommunizieren werkseitig im Peer-to-Peer-Mode. D. h., jedes Modem kann mit jedem
Modem im Netz kommunizieren. Es werden Daten ausgetauscht, Netzwerkspiele übertragen, oder es kann auf einen zentralen Netzwerkdrucker zugegriffen werden. Zur Überwachung von Häusern, Innenräumen etc. lässt sich auch eine IP-Überwachungskamera über ein EoC Modem betreiben.
1.2.2. Master-Slave-Mode
Beim Master-Slave-Mode verbindet ein Master-Gerät bis zu 63 Slave-Geräte mit dem Internet. Eine
Kommunikation zwischen den einzelnen Modems ist nicht möglich. Der Betrieb in Hotels oder Pensionen ist ein typischer Anwendungsfall für den Master-Slave-Mode. Wenden Sie sich zum Umstellen der EoC-Modems in den Master-Slave Mode an den technischen Support von AXING ( www.axing.com
| Technischer Support).
1.3. Anschlüsse, Anzeigen, Bedienelemente
An der TV-F-Buchse auf der Rückseite des EoC-Modem kann ein TV- oder Radiogerät angeschlossen werden.
Der eingebaute Verteiler ist mit einem hochselektiven Filter bestückt, wodurch der TV-/Radioempfang nicht vom Datenverkehr gestört wird.
Wenn Sie die TV-Buchse nicht verwenden, schließen Sie diese mit dem beiliegenden
Abschlusswiderstand CFA 8-00 ab!
6 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
1.4. Anwendungsbeispiele
Alle Komponenten in der Verteilstruktur müssen den Rückkanal-Frequenzbereich 5-65 MHz unterstützen. Dies gilt insbesondere für die SAT-Multischalter, das passive Verteilmaterial und für die Antennensteckdosen.
1.4.1. Internet vom Kabelnetzbetreiber
Die IP-Daten werden am Modem-Anschluss einer BSD 963-13 mit Hilfe eines Kabelmodems empfangen und
über einen Router an ein EoC 2-01 weitergeleitet. Die IP-Daten werden anschließend über eine Einspeiseweiche
TZU 40-04 in das Verteilnetz eingespeist und können an den anderen EoC-Modems empfangen werden.
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
7
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
1.4.2. Internet vom Telefonanbieter
Die Einspeisung des IP-Signals erfolgt über eine rückkanaltaugliche Antennendose . Bei einer IP-Daten-
Einspeisung über die Antennendose muss ein Hochpassfilter TZU 19-65 in die koaxiale Zuleitung
(Verstärkerausgang) installiert werden.
1.4.3. Einspeisung in einer SAT-ZF-Verteilstruktur:
Die Einspeisung des IP-Signals erfolgt über den rückkanaltauglichen terrestrischen Eingang des
Multischalters. Es wird eine Einspeiseweiche TZU 40-04 verwendet.
8 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
2. Installation und Inbetriebnahme
1. Verbinden Sie den Router mit dem beiliegenden Ethernet-Kabel an einer der beiden RJ 45 LAN- Buchsen des
EoC-Modems.
2. Schließen Sie die EoC-F-Buchse an der vorhandenen Antennennetzstruktur an
(siehe Beispiel 1 bis 4).
Es gibt mehrere Möglichkeiten, die IP-Daten in die vorhandene Antennennetzstruktur einzuspeisen.
– über eine rückkanaltaugliche Antennendose im Verteilnetz (siehe Beispiel 1 oder 3)
– über den passiven terrestrischen Eingang des SAT-Multischalters oder den passiven terrestrischen
Eingang einer Verteilstruktur (siehe Beispiel 2 oder 4).
3. Verbinden Sie Ihren Computer mit dem beiliegenden Ethernet-Kabel an einer der beiden RJ 45 LAN-Buchsen des zweiten EoC-Modem.
4. Schließen Sie dann das EoC-Modem über die EoC-F-Buchse an der rückkanaltauglichen Antennensteckdose
(siehe Beispiel 1 oder 3) oder an der rückkanaltauglichen EoC-Einspeiseweiche siehe Beispiel 2 oder 4) an.
Wiederholen Sie Schritt 3 + 4 für weitere Inbetriebnahmen von EoC 1-01.
Nachdem alle Verbindungen hergestellt wurden, können die EoC-Geräte mit dem Netzschalter eingeschaltet und die angeschlossenen Geräte (PC, Notebook etc.) hochgefahren werden.
Die LEDs Power, EoC, LAN und WiFi leuchten und der Datenverkehr ist hergestellt.
Hinweise:
∂ An einem EoC-Modem können bis zu 2 netzwerkfähige Geräte angeschlossen werden.
∂ Zusätzlich kann an der TV-F-Buchse des EoC-Modems ein TV- oder Radio-Gerät angeschlossen werden.
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
9
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
2.1. Anschlussbeispiele an AXING-Antennendosen
BSD 21-xx
Hyperbreitbandsteckdose
BSD 960-xxN
Multimedia-
Antennensteckdosen
BSD 961-xxK
Multimedia-
Antennensteckdosen
BSD 963-xxN
Multimedia-
Antennensteckdosen
10 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
SSD 5-xx SAT-
Antennensteckdose
SSD 5-15 SAT-
Multimedia-
Antennensteckdose
SSD 7-00 SAT-Twin-
Antennensteckdose
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
11
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
3. Basisfunktionen
Nachdem Sie Ihr EoC-Modem eingeschaltet haben, sollten die LEDs folgenden Status anzeigen:
∂ Die Power-LED leuchtet grün.
Nach ca. 10 Sekunden leuchten/blinken die LEDs wie folgt:
∂ EoC-LED grün (blinkt bei Datenverkehr)
∂ LAN-LED grün (blinkt bei Datenverkehr)
∂ WiFi-LED grün (wenn WiFi eingeschaltet ist) grün (blinkt bei Datenverkehr)
3.1. Standby-Modus:
Das EoC-Modem schaltet nach einigen Minuten ohne Datenverkehr in den Standby-Modus. Die Power-LED blinkt dann grün.
3.2. EoC-Reset-Taste:
Mit der EoC-Reset-Taste können Sie folgende Funktionen durchführen: auf Werkseinstellung zurückgesetzt (> 10 s drücken) die Netzwerkkennung eines EoC-Modems löschen (5…8 s drücken) ein privates Netzwerk erzeugen (<1 s drücken)
3.3. EoC Reset Funktion:
Halten Sie die EoC-Reset-Taste mit einer Büroklammer 10 Sekunde gedrückt, um das Gerät auf die
Werkseinstellung zurückzusetzen.
Die EoC-Reset-Taste hat im Standby-Modus keine Funktion.
12 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
4. EoC-Netzwerk mit Verschlüsselung
Ein EoC-Netzwerk besteht aus zwei oder mehreren (maximal 64) EoC-Modems, die denselben
Netzwerkschlüssel verwenden.
In einer vorhandenen Mehrteilnehmer-Antennenanlage können sich alle Geräte miteinander verbinden. Sie sollten deswegen ein privates EoC-Netzwerk aufbauen.
Durch die Absicherung Ihres EoC-Netzwerkes, schützen Sie die Informationen, die Sie über das Netzwerk versenden, vor ungewolltem Zugriff. Dies ist besonders in Mehrfamilienhäusern, Bürogebäuden, Schulen und anderen Gebäuden relevant.
Es gibt zwei Möglichkeiten, um Ihr EoC-Netzwerk abzusichern:
∂ Mit der EoC-Reset-Taste generieren Sie automatisch einen zufälligen Netzwerkschlüssel.
∂ Über die Security-Software legen Sie einen Schlüssel für Ihr EoC-Netzwerk fest
(kostenloser Download unter http://www.axing.com
| Download).
4.1. Paar- bzw. Gruppenbildung:
Löschen des Netzwerkschlüssels:
Wenn Sie einen individuellen Netzwerkschlüssel generieren wollen, dann löschen Sie zunächst den werkseitig eingestellten. Drücken Sie die Security-Taste an der Rückseite des EoC-Gerätes 5…8 Sekunden (bis die Power-
LED blinkt). Führen Sie dies bei allen Geräten durch.
Paar- bzw. Gruppenbildung
Drücken Sie kurz (<1 s) die Security-Taste an der Rückseite des EoC-Gerätes. Die Power-LED fängt an zu blinken. Drücken Sie jetzt beim nächsten EoC-Modem ebenfalls kurz die Security-Taste. Es wird ein neuer
Netzwerkschlüssel zwischen den beiden EoC-Modems generiert und die Geräte verbinden sich miteinander. Die
EoC LED blinkt kurzzeitig auf.
Um beide Geräte miteinander zu verbinden, haben Sie ca. 2 Minuten Zeit, um am zweiten Gerät die Security-
Taste zu drücken.
Überprüfen Sie die LEDs an den beiden EoC-Geräten. Die Power-LEDs sollten blinken, während die Geräte verbunden werden. Warten Sie etwa eine Minute, während sich die EoC-Geräte verbinden. Nach Abschluss des
Vorgangs leuchten beide Power- und EoC LEDs.
Wenn die Power-LED nicht blinkt, nachdem Sie die Security-Taste gedrückt haben, haben Sie diese u. U. zu lange gedrückt.
Versuchen Sie es erneut und drücken Sie die Security-Taste <1 Sekunde lang.
Sollten die EoC-LEDs an beiden EoC-Geräten nicht leuchten, sind die EoC-Geräte nicht verbunden. Wiederholen
Sie die Schritte in diesem Abschnitt.
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
13
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
5. Fehlerbehebung
5.1. LEDs
Die LEDs zeigen „Aktivität“ an und dienen zur Fehlerbehebung.
Power-LED aus
Stellen Sie sicher, dass das Netzkabel richtig angeschlossen ist.
Stellen Sie sicher, dass das EoC-Modem mit dem Netzschalter eingeschaltet ist.
LAN-LED blinkt nicht
Kein Datentransfer. Überprüfen Sie Folgendes:
Sind Ihr Router und Modem eingeschaltet?
Ist das Ethernet-Kabel fest mit einem LAN-Port des Routers/Modems verbunden?
Kann ein direkt mit dem Router verbundene PC auf das Internet zugreifen?
Drücken Sie die EoC-Reset-Taste an jedem EoC-Modem 10 Sekunden lang, um die Werkseinstellungen des
EoC-Modems wiederherzustellen.
Generieren Sie ggf. einen neuen Netzwerkschlüssel (siehe Kapitel 4 auf Seite 13).
EoC-LED aus – leuchtet nicht
Die EoC-Geräte finden sich nicht.
Stellen Sie sicher, dass die EoC-Geräte an das gleiche Antennennetzwerk angeschlossen sind und dass sie denselben Netzwerkschlüssel verwenden.
Positionieren Sie das EoC-Modem etwas näher am Computer oder EoC-Modem.
Wenn Sie die Netzwerksicherheit aktiviert haben, stellen Sie sicher, dass sämtliche EoC-Modems denselben
Netzwerkschlüssel verwenden.
Wenn das Problem auftritt, nachdem Sie den Netzwerkschlüssel geändert haben, stellen Sie die
Werkseinstellungen jedes Geräts wieder her. Danach können Sie den Netzwerkschlüssel erneut erzeugen
(siehe Kapitel 4 auf Seite 13).
Prüfen Sie, ob ihre Antennenanlage rückkanaltauglich ist.
EoC-LED leuchtet rot
Die Leitungsdämpfung zwischen den EoC-Modems ist zu hoch. Positionieren Sie das EoC-Modem etwas näher an das Master-Gerät.
14 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
6. Technische Daten
6.1. Datenblatt
Frequenzbereich
EoC-Ein-/Ausgang
IP-Signal
TV-Ausgang
Durchgangsdämpfung
Ausgangspegel min. 1…30 MHz
Ausgangspegel min. 30…68 MHz
Netzwerk
Brutto Datenrate
Netto Datenrate
Reichweite
Modulation
Verschlüsselung
Ethernet-Schnittstelle
Netzwerkstandard
WiFi-Netzwerkstandard
Frequenzbereich
Anschlüsse (TV/EoC)
Anschlüsse (LAN)
LEDs:
Schaltnetzteil
Leistungsaufnahme
Betriebstemperatur
Abmessungen
Entspricht den Normen
2…1006 MHz
2…68 MHz
85…1006 MHz
<0,5 dB
100 dBµV
90 dBµV
Bis zu 64 EoC-Modems
500 Mbps
230 Mbps bis zu 700 m
4096/1024/256/64/16/8-QAM, QPSK, BPSK und
ROBO Modulationschema
128 bit AES
10/100/1000 Mbps
Home Plug AV IEEE1901, IEEE802.3, IEEE802.3u
IEEE 802.11/b/g/n
13 channels 2.412GHz~2.472GHz
2 x F-Buchse
2 x RJ 45
Power /EoC /LAN/WiFi
110-230 V~ 50/60 Hz max. 5,5 W
0°C ~ 40°C
145 (B) x 82,5 (T) x 33 (H) mm
EN 50083-2 Klasse A
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
15
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
6.2. Bohrschablone
16 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
17
Betriebsanleitung | EoC 1-01 | Ethernet over Coax
18 2018-02-04 | Technische Verbesserungen, Änderungen im Design, Druckfehler und Irrtümer vorbehalten.
EoC 1-01
Ethernet over Coax
Operation Instructions
Operation Instructions | EoC 1-01 | Ethernet over Coax
Contents
2 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
Safety instructions
Do NOT use the device near water or in rooms with high humidity such as humid cellars or near swimming pools.
Do NOT use the device outdoors. All connections must be located inside a building.
Keep the device away from moisture, dust or corrosive liquids.
Do NOT install the device, use it or perform maintenance during a thunderstorm. There is a risk of electric shock during thunderstorm.
Connect ONLY appropriate accessories to the device.
Make sure that all cables are connected to the correct port.
Carefully lay the Ethernet, antenna and electric cables to ensure that nobody can step on or stumble over them.
Do NOT cover the ventilation slots of the device since insufficient air supply may result in damage to the device.
Do NOT place any objects on the device. Position the device in a place where NOBODY can step on it.
Prior to maintenance or dismounting work, disconnect the Ethernet and electric cable from the device.
In case of damage, interrupt the power supply.
Do NOT try to repair the device. Contact your local retailer to order a new device.
Do NOT open the device or unit. Opening the device or removing its covers causes risks, for example due to high voltage. This device should ONLY be repaired or uninstalled by qualified service personnel. For more information, contact your retailer.
Herewith AXING AG declares that the marked products comply with the valid guidelines. You can call up the complete EU declaration of conformity for download by entering the article in the search field at www.axing.com.
WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of as residual waste, it must be disposed of separately.
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
3
Operation Instructions | EoC 1-01 | Ethernet over Coax
1. Product description
1.1. Scope of delivery
EoC 1-01
1 x EoC 1-01 Ethernet over Coax Modem
1 x Network cable 1.5 m (RJ45)
1 x Power cable with euro plug
1 x CFA 8-00 terminating resistor
1 x Quick Start Guide
EoC 1-00
2 x EoC 1-01 Ethernet over Coax Modem
2 x Network cable 1.5 m (RJ45)
2 x Power cable with euro plug
2 x CFA 8-00 terminating resistor
2 x Quick Start Guide
Available accessories:
∂ IEC connecting cable 1.5…10 m BAK 150-80 – 999-80
∂ Modem connecting cable 1.5…10 m MAK 150-80 – 999-80
∂ Adapter F/IEC
∂ Adapter F/IEC
CFA 1-00, IEC socket / F plug
CFA 10-00, IEC plug / F plug
∂ Combiner TZU 40-03/-04
4 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
1.2. Field of application
The EoC 1-01 modem allows feeding in of IP data signals from the Internet, for example via a router in an existing coaxial antenna distributor, such as SAT-IF-, DVB-T, CATV- or head end distribution systems (in the star or tree distribution).
The advantage of an ethernet solution over a coax solution is that no new network cables must be laid. The data is transmitted through the low-attenuation return channel, frequency range of 2...68 MHz. Depending on the quality of the coaxial cable, transmission distances of up to 700 m can be realized.
The feeding in is performed via the return channel capable terrestrial input of the SAT multiswitch, via the terrestrial input of the antenna distributor structure or via a return channel capable antenna socket in the distribution network.
Internet or other fed IP data are available at return channel capable antenna sockets ().
Two networkable devices can be connected to the LAN ports of a EoC modem. The IP network can be extended to up to 64 EoC devices.
All devices connected to the EoC modems can communicate between each other. Data is exchanged, network games are transmitted or a centralized network printer can be accessed. For the monitoring of houses, rooms etc., an IP camera can be operated via a EoC modem.
1.2.1. Peer-to-Peer mode
The Eoc 1-01 modems communicates per default in a Peer-to-Peer mode. This means that each modem can communicate with each modem in the network. Data is exchanged, network games are transmitted or a centralized network printer can be accessed. For the monitoring of houses, rooms etc., an IP camera can be operated via a EoC modem.
1.2.2. Master/Slave mode
In the master/slave mode one master device connects up to 63 slave devices with the internet. Communication between the modems isn´t possible. The applikation in hotels or boarding houses ar typical uses of the
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
5
Operation Instructions | EoC 1-01 | Ethernet over Coax master/slave mode. Please contact the technical support of AXING, to change from the peer-to-peer mode to the master/salve mode ( www.axing.com
| Technischer Support).
1.3. Connections, indications, operating elements
1. Power ON/OFF
2. LAN 2, RJ 45 socket
3. EoC F-socket (data + TV 2-862 MHz)
4. TV- F socket (85-862 MHz)
5. Reset button
6. Security button
7. LAN 1, RJ 45 socket
8. Mains socket 110-230 V
9. Power LED
10. EoC LED
11. LAN 1 LED
12. LAN 2 LED
A TV or radio device can be connected to the TV-F socket on the rear side of the EoC modem. The integrated distributor is equipped with a highly selective filter so that the TV/radio reception is not interfered with by the data traffic.
If the TV F socket ist not used, the socket has to be terminated with an termination resistor
CFA 8-00!
6 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
1.4. Application examples
All components in the distribution structure must support the return channel frequency range 2-68 MHz. This also applies to SAT multiswitches, the passive distribution components and for antenna sockets.
1.4.1. Internet from the cable network operator
The IP data are received with a cable modem at the modem connector of a BSD 963-13 antenna wall outlet.
The cable modem ist connected to an EoC 2-01 via LAN. The IP data is feed in via an EOC inserter (TZU 40-04) into the distribution network and can be received from the other EoC.
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
7
Operation Instructions | EoC 1-01 | Ethernet over Coax
1.4.2. Internet from the telephone provider
The feeding of the IP signal is performed via the return channel capable antenna socket .
If the IP-data are fed via the antenna socket, a high-pass filter TZU 19-65 must be installed in the coaxial supply line (amplifier output).
1.4.3. Feeding in of IP data in a SAT-IF distribution structure:
8 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
The feeding of the IP signal is performed via the return channel capable terrestrial input of the multiswitch . A combiner TZU 40-04 is used. It prevents that the IP signals are transferred via the return channel into the receive antenna system.
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
9
Operation Instructions | EoC 1-01 | Ethernet over Coax
2. Installation and commissioning
1. Connect the router with the enclosed Ethernet cable to one of both RJ-45 LAN sockets of the EoC modem.
2. Connect the EoC socket to the available antenna network structure
(see example 1 to 4).
There are several ways to feed the IP data into the existing antenna network structure.
– via a return channel capable antenna socket in the distribution network (see example 1 or 3)
– via the passive terrestrial input of the SAT multiswitch or the passive terrestrial input of a distribution structure (see example 2 or 4).
3. Connect your computer using the enclosed Ethernet cable to one of both RJ-45 LAN sockets of the second
EoC modem.
4. Then connect the EoC modem using the EoC-F socket to the return channel capable antenna socket (see example 1 or 3) or to the return channel capable EoC combiner (see example 2 or 4).
Repeat step 3 + 4 for further commissioning of EoC 1-01.
After all connections have been established, the EoC devices can be switched on by means of the mains switch and the connected devices (PC, laptop etc.) can be booted up.
The LEDs Power, EoC, LAN and WiFi are lit and the data transfer is established.
Notes:
∂ Up to two networkable devices can be connected to one EoC modem.
∂ Additionally, a TV or radio device can be connected to the TV-F socket of the EoC modem.
10 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
2.1. Connection examples for AXING antenna wall outlets
BSD 21-xx
Extended wideband wall outlets
BSD 960-xxN
Multimedia antenna wall outlets
BSD 961-xxK
Multimedia antenna wall outlets
BSD 963-xxN
Multimedia antenna wall outlets
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
11
Operation Instructions | EoC 1-01 | Ethernet over Coax
SSD 5-xx SAT antenna wall outlets
SSD 5-15 SAT multimediaantenna wall outlets
SSD 7-00 SAT twin antenna wall outlets
12 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
3. Basic functions
After having switched on the EoC modem, the LEDs should indicate the following states:
∂ The green Power LED is lit.
– After approx. 10 seconds, the LEDs are lit/flashing as follows:
– EoC LED green (flashes in case of data traffic)
– LAN LED green (flashes in case of data traffic)
– WiFi LED green (if WiFi is switched on) green (flashing in case of data traffic)
3.1. Standby mode:
The EoC modem switches after several minutes without data traffic to the Standby mode. The Power LED is flashing green then.
3.2. EoC Reset button:
The EoC reset button is used for the following functions:
∂ reset to the factory default setting (press > 10 s).
∂ delete the network key (press 5…8 s)
∂ generate a private network (press <1 s)
3.3. EoC Reset Function:
Hold the reset button depressed for one second using a bent up paper clip, in order to reset the device to the factory defaults.
The EoC reset button does not work in standby mode.
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
13
Operation Instructions | EoC 1-01 | Ethernet over Coax
4. EoC network with encryption
An EoC network consists of two or several (maximum 64) EoC modems which use the same network key.
In an existing antenna system with several participants, all devices can communicate with each other.
Therefore, you should create a private EoC network.
Securing your EoC network allows you to protect the information sent via the network from unauthorized access. This is particularly important in multi-family homes, office buildings, schools and other buildings.
There are two ways to secure your EoC network.
∂ Use the security button to generate a random network key automatically.
∂ You can use the Security software to specify a key for your EoC network (free download under http://www.axing.com | Download).
4.1. Pair or group formation:
Deleting the network key:
To generate an invidual network key, you have to delete the default network key first. Press the security button on the rear side of the EoC device for 5…8 seconds (until the Power LED flashes). Carry out this step for all devices.
Pair and group formation:
Press the security button briefly (<1 s) on the rear side of the EoC device. The Power LED starts flashing. Now also press the security button of the next EoC modem briefly. A new network key between the two EoC modems is generated and the devices establish a connection. The EoC LED will flash for a short time.
In order to connect the two devices to each other, press the security button on the second device within a time period of two minutes.
Check the LEDs on both EoC devices. The Power LEDs must flash during the connection establishment of the devices. Wait for approx. one minute while the EoC devices get connected to each other. As soon as the procedure has been completed, both Power- and EoC LEDs are again permanently lit.
If the Power LED is not flashing, after you have pressed the security button, then you might have kept it pressed for too long.
Try it again and press the security button for <1 second.
If the EoC LEDs are not lit on both EoC devices, the EoC devices are not connected. Repeat the steps in this section.
14 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
5. Troubleshooting
5.1. LEDs
LEDs
The LEDs indicate an "activity" and are used for troubleshooting.
Power LED off
Make sure that the network cable is connected correctly.
Make sure that the mains switch of the EoC modem is switched on.
LAN LED is not flashing
No data traffic. Check the following:
Are the router and the modem switched on?
Is the Ethernet cable connected firmly to the LAN port of the router/modem?
Can the PC - connected to the router - establish a connection to the Internet?
Press the EoC Reset button on each EoC modem for 10 seconds to restore the factory settings of the EoC modem.
If necessary generate a new network key (see chapter 4 on page 12).
EoC LED off - is not lit
The EoC devices cannot be found.
Make sure that the EoC devices are connected to the same antenna network and that they use the same network key.
Position the EoC modem closer to the computer or the EoC modem.
After having activated the network security, make sure that all EoC modems use the same network key.
If the problem occurs, after the network key has been changed, re-establish the factory settings of each device again. Then, you can generate the key again (see chapter 4 on page 12).
Check whether your antenna system provides a return channel.
EoC-LED is lit in red
The line attenuation between the EoC modem is too high. Position the EoC modem closer to the master device.
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
15
Operation Instructions | EoC 1-01 | Ethernet over Coax
6. Technical data
6.1. Data sheet
Frequency range
EoC input/output
IP signal
TV output
Through loss
Output level min. 1…30 MHz
Output level min. 30…68 MHz
Network
Gross data rate
Net data rate
Range
Modulation
Encryption
Ethernet interface
Network standards
WiFi network standard
Frequency range
Connections (TV/EoC)
Connections (LAN)
LEDs
Switching power supply unit
Power consumption
Operating temperature
Dimensions
Corresponds to the standards
2…1006 MHz
2…68 MHz
85…1006 MHz
<0,5 dB
100 dBµV
90 dBµV
Up to 64 EoC modems
500 Mbps
230 Mbps up to 700 m
4096/1024/256/64/16/8-QAM, QPSK, BPSK and
ROBO modulation scheme
128 bit AES
10/100/1000 Mbps
Home Plug AV IEEE1901, IEEE802.3, IEEE802.3u
IEEE 802.11/b/g/n
13 channels 2.412GHz~2.472GHz
2 F sockets
2 RJ 45
Power /EoC /LAN/WiFi
110-230 V~ 50/60 Hz max. 5.5 W
0°C ~ 40°C
145 (W) x 82.5 (D) x 33 (H) mm
EN 50083-2 Class A
16 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
6.2. Drilling template
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
17
Operation Instructions | EoC 1-01 | Ethernet over Coax
18 2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
2018-02-04 | Technical improvements, changes in design, printing- and other errors expected.
19
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Betriebsanleitung
- 4 1. Produktbeschreibung
- 4 1.1. Lieferumfang
- 4 EoC 1-01
- 4 EoC 1-00
- 4 Lieferbares Zubehör:
- 5 1.2. Verwendungsbereich
- 6 1.2.1. Peer-to-Peer-Mode
- 6 1.2.2. Master-Slave-Mode
- 6 1.3. Anschlüsse, Anzeigen, Bedienelemente
- 7 1.4. Anwendungsbeispiele
- 7 1.4.1. Internet vom Kabelnetzbetreiber
- 8 1.4.2. Internet vom Telefonanbieter
- 8 1.4.3. Einspeisung in einer SAT-ZF-Verteilstruktur:
- 9 2. Installation und Inbetriebnahme
- 10 2.1. Anschlussbeispiele an AXING-Antennendosen
- 12 3. Basisfunktionen
- 12 3.1. Standby-Modus:
- 12 3.2. EoC-Reset-Taste:
- 12 3.3. EoC Reset Funktion:
- 13 4. EoC-Netzwerk mit Verschlüsselung
- 13 4.1. Paar- bzw. Gruppenbildung:
- 14 5. Fehlerbehebung
- 14 5.1. LEDs
- 14 Power-LED aus
- 14 LAN-LED blinkt nicht
- 14 EoC-LED aus – leuchtet nicht
- 14 EoC-LED leuchtet rot
- 15 6. Technische Daten
- 15 6.1. Datenblatt
- 16 6.2. Bohrschablone
- 19 Operation Instructions
- 22 1. Product description
- 22 1.1. Scope of delivery
- 22 EoC 1-01
- 22 EoC 1-00
- 22 Available accessories:
- 23 1.2. Field of application
- 23 1.2.1. Peer-to-Peer mode
- 23 1.2.2. Master/Slave mode
- 24 1.3. Connections, indications, operating elements
- 25 1.4. Application examples
- 25 1.4.1. Internet from the cable network operator
- 26 1.4.2. Internet from the telephone provider
- 26 1.4.3. Feeding in of IP data in a SAT-IF distribution structure:
- 28 2. Installation and commissioning
- 29 2.1. Connection examples for AXING antenna wall outlets
- 31 3. Basic functions
- 31 3.1. Standby mode:
- 31 3.2. EoC Reset button:
- 31 3.3. EoC Reset Function:
- 32 4. EoC network with encryption
- 32 4.1. Pair or group formation:
- 32 Deleting the network key:
- 32 Pair and group formation:
- 33 5. Troubleshooting
- 33 5.1. LEDs
- 33 LEDs
- 33 Power LED off
- 33 LAN LED is not flashing
- 33 EoC LED off - is not lit
- 33 EoC-LED is lit in red
- 34 6. Technical data
- 34 6.1. Data sheet
- 35 6.2. Drilling template