axing EoC 2-01 premium-line Schnellstartanleitung
Add to my manuals
4 Pages
Axing EoC 2-01 premium-line is a high-performance Ethernet over Coax (EoC) modem designed to provide reliable and high-speed data transmission over existing coaxial cables. It is ideal for use in homes, offices, and other environments where there is a need for a wired network connection but where it is impractical or impossible to run Ethernet cables.
With its advanced modulation techniques, the Axing EoC 2-01 premium-line can achieve data rates of up to 500 Mbps, making it suitable for even the most demanding applications such as streaming video, online gaming, and large file transfers. It also supports a range of encryption standards to ensure the security of your data.
advertisement
Beachten Sie die folgenden Sicherheitshinweise!
4 NICHT in der Nähe von Wasser oder in feuchten Räumen, z. B. feuchten Kellern oder in der Nähe von Schwimmbecken verwenden.
4 Das Gerät NICHT im Freien verwenden. Alle Verbindungen müssen sich innerhalb eines Gebäudes befinden.
4 Gerät von Feuchtigkeit, Staub oder ätzenden Flüssigkeiten fernhalten.
4 Das Gerät NICHT während eines Gewitters installieren, verwenden oder warten. Bei Gewitter besteht die Gefahr eines Stromschlags.
4 AUSSCHLIESSLICH geeignete Zubehörteile an das Gerät anschließen.
4 Sicher stellen, dass alle Kabel an den korrekten Port angeschlossen sind.
4 Ethernet-, Antennen- und Stromkabel sorgfältig verlegen, so dass niemand darauf treten oder darüber stolpern kann.
4 Die Lüftungsschlitze des Geräts NICHT abdecken, da eine ungenügende Luftzufuhr zur Beschädigung des Geräts führen kann.
4 KEINE Gegenstände auf das Gerät legen. Das Gerät so platzieren, dass NIEMAND auf das Gerät treten kann.
4 Vor Wartung oder Demontage immer das Ethernet- und Stromkabel vom Gerät trennen.
4 Bei Beschädigung Stromzufuhr zum Gerät unterbrechen.
4 KEINE Reparaturversuche unternehmen. Kontaktieren Sie Ihren
Händler, um ein neues Gerät zu bestellen.
4 Das Gerät oder die Einheit NICHT öffnen. Nach dem Öffnen oder
Entfernen von Verkleidungen bestehen Risiken, z. B. durch gefährlich hohe Spannung. Dieses Gerät ist AUSSCHLIESSLICH durch qualifiziertes Servicepersonal zu warten oder zu deinstallieren. Kontaktieren Sie Ihren Händler für weitere
Informationen.
Technische Daten:
Frequenzbereich
EoC-Anschluss ...............................................................2…1006 MHz
Daten-Übertragungsbereich ..............................................2…68 MHz
TV-Ausgang .................................................................85…1006 MHz
Durchgangsdämpfung ......................................................................<0,5 dB
Ausgangspegel min. 1…30 MHz...................................................100 dBµV
Ausgangspegel min. 30…68 MHz ................................................90 dBµV
Netzwerk ..................................................................Bis zu 64 EoC-Modems
Bruttodatenrate.............................................................................500 Mbps
Nettodatenrate..............................................................................230 Mbps
Reichweite ...............................................................................bis zu 700 m
Modulation....................................................4096/1024/256/64/16/8-QAM,
..................................................QPSK, BPSK und ROBO Modulationschema
Verschlüsselung ..........................................................................128 bit AES
Ethernet-Schnittstelle......................................................10/100/1000 Mbps
Netzwerkstandard .............Home Plug AV IEEE1901, IEEE802.3, IEEE802.3u
WiFi-Netzwerkstandard.....................................................IEEE 802.11 b/g/n
Frequenzbereich ......................................13 channels 2.412GHz~2.472GHz
Anschlüsse (TV/EoC)..................................................................2 x F-Buchse
Anschlüsse (LAN)............................................................................2 x RJ-45
LEDs: ............................................................................Power/EoC/LAN/WiFi
Schaltnetzteil ..............................................................110-230 V~ 50/60 Hz
Leistungsaufnahme ....................................................................max. 5,5 W
Betriebstemperatur.....................................................................0°C ~ 40°C
Abmessungen ...............................................145 (B) x 82,5 (T) x 33 (H) mm
Entspricht den Normen.................................................EN 50083-2 Klasse A
Unter www.axing.com finden Sie folgende Zusatzinformationen:
4 Betriebsanleitung EoC
4 Softwarehandbuch EoC
4 Anwendungsbeispiele SMARTSolutions
EoC 2-01/2-00 premium -line
Ethernet over Coax
500 Mbps Modem
Quickstart-Anleitung
Stand 2016-04-27 - Technische Änderungen, Änderungen im Design,
Druckfehler und Irrtümer vorbehalten.
Hersteller
AXING AG
Gewerbehaus Moskau
CH-8262 Ramsen
EWR-Kontaktadresse
Bechler GmbH
Am Rebberg 44
D-78239 Rielasingen
Lieferumfang
Ethernet over Coax Modem
Netzwerkkabel 1,5 m (RJ-45)
Stromversorgungskabel mit Eurostecker
CFA 8-00 Abschlusswiderstand
Quickstart-Anleitung
EoC 2-01
1
1
1
1
1
EoC 2-00
2
2
2
2
2
Produktbeschreibung
Das EoC 2-01 Modem ermöglicht die Einspeisung von IP-Datensignalen in eine vorhandene koaxiale Antennenverteilung (in Stern- oder
Baumverteilung). Die Modems kommunizieren im Peer-to-Peer-Mode, jedes Modem kann mit jedem Modem im Netz kommunizieren. Die
Übertragung erfolgt im Rückkanal-Frequenzbereich von 2…68 MHz (Up- und Downstream).
Die Einspeisung erfolgt über den rückkanaltauglichen terrestrischen
Eingang eines SAT-Multischalters, den terrestrischen Eingang einer
Antennenverteilstruktur oder über eine rückkanaltaugliche
Antennendose im Verteilnetz.
An einem EoC-Modem können zwei netzwerkfähige Geräte an den LAN-
Anschlüssen angeschlossen werden. Das Netzwerk kann auf bis zu 64
EoC-Geräte ausgebaut werden.
Das EoC 2-01 WiFi Modem besitzt zusätzlich WLAN-Funktion. Dadurch können Smartphones, Tablets und andere WLAN-Endgeräte ins Netzwerk integriert werden.
Installation (typisches Beispiel)
Alle Komponenten in der Verteilstruktur müssen den Rückkanal-
Frequenzbereich von 5…65 MHz unterstützen. Dies gilt insbesondere für die
SAT-Multischalter, das passive Verteilmaterial und für die Antennensteckdosen.
4 Internet-Router am ersten EoC-Modem an einer der beiden RJ-45 LAN-
Buchsen anschließen.
4 EoC-F-Buchse an der vorhandenen Antennennetzstruktur anschließen.
4 Computer am zweiten EoC-Modem an einer der beiden RJ-45 LAN-
Buchsen anschließen.
4 EoC-Modem über die EoC-F-Buchse an der rückkanaltauglichen
Antennensteckdose anschließen.
An der TV-F-Buchse auf der Rückseite des EoC-Modem kann ein TV- oder
Radiogerät angeschlossen werden.
Wenn Sie die TV-Buchse nicht verwenden, schließen Sie diese mit dem beiliegenden Abschlusswiderstand CFA 8-00 ab!
Ethernet over Coax in/out
LAN
RJ-45
EoC-Netzwerk mit Verschlüsselung:
Ein EoC-Netzwerk besteht aus zwei oder mehreren (maximal 64) EoC-
Modems, die denselben Netzwerkschlüssel verwenden. Durch die
Verschlüsselung Ihres EoC-Netzwerkes, schützen Sie die Informationen, die Sie über das Netzwerk versenden, vor ungewolltem Zugriff.
4 Zunächst den werkseitig eingestellten Netzwerkschlüssel löschen.
4 Dazu bei allen Geräten die EoC-Reset-Taste an der Rückseite
5…8 Sekunden drücken (bis die Power-LED blinkt).
Paar- bzw. Gruppenbildung
4 Beim ersten Gerät die EoC-Reset-Taste an der Rückseite kurz
(<1 s) drücken .
Die Power-LED fängt an zu blinken.
4 Innerhalb von zwei Minuten beim anderen Gerät/bei den anderen Geräten ebenfalls kurz die EoC-Reset-Taste drücken .
Ein neuer Netzwerkschlüssel wird generiert und die Geräte verbinden sich miteinander.
4 Die EoC LED blinkt kurzzeitig auf.
4 Nach Abschluss leuchten die Power- und EoC-LEDs.
Alternativ legen Sie einen Schlüssel mit der kostenlosen Security-
Software für Ihr EoC-Netzwerk fest (www.axing.com | Download)
Up- and Downstream (Coax)
HF/RF out Power In
LAN
*
EoC 1-01/
EoC 2-01
TV
Coax
Up- and Downstream (Coax)
LAN
Power
ON/OFF
LAN
RJ-45
WiFi
ON/OFF
Nach dem Einschalten:
a
Die Power-LED leuchtet grün.
Nach ca. 10 Sekunden leuchten/blinken die LEDs wie folgt: a
EoC-LED grün (blinkt bei Datenverkehr) a
LAN-LED grün (blinkt bei Datenverkehr) a WiFi-LED grün (leuchtet wenn WiFi eingeschaltet ist, blinkt bei
Datenverkehr)
Standby-Modus:
Das EoC-Modem schaltet nach einigen Minuten ohne Datenverkehr in den
Standby-Modus. Die Power-LED blinkt grün.
120 s
TV
WiFi
4 Den WiFi-Schalter auf ON schalten. WiFi ist aktiv: a
Netzwerkname (SSID) = EoCxxxxxx
(xxxxxx = letzte sechs Zeichen der MAC-Adresse) a
Verschlüsselung = WPA2 a
Kennwort = 0000000000000000
Sie sollten das Standard-Kennwort ändern, um Ihr WiFi-
Netzwerk abzusichern.
Einstellungen für das WiFi-Netzwerk
Das EoC 2-01 WiFi-Modem konfigurieren Sie mit einem Web-Browser: a Werks-IP-Adresse = 192.168.100.111 a
Subnetz-Maske = 255.255.255.0
a Benutzername = admin a
Kennwort = 000000
Observe the following safety instructions!
4 Do NOT use the device near water or in rooms with high humidity such as humid cellars or near swimming pools.
4 Do NOT use the device outdoors. All connections must be located inside a building.
4
4
Keep the device away from moisture, dust or corrosive liquids.
Do NOT install the device, use it or perform maintenance during a
4
4
4
4
4
4
4
4
4 thunderstorm. There is a risk of electric shock during thunderstorm.
Connect ONLY appropriate accessories to the device.
Make sure that all cables are connected to the correct port.
Carefully lay the Ethernet, antenna and electric cables to ensure that nobody can step on or stumble over them.
Do NOT cover the ventilation slots of the device since insufficient air supply may result in damage to the device.
Do NOT place any objects on the device. Position the device in a place where NOBODY can step on it.
Prior to maintenance or dismounting work, disconnect the Ethernet and electric cable from the device.
In case of damage, interrupt the power supply.
Do NOT try to repair the device. Contact your local retailer to order a new device.
Do NOT open the device or unit. Opening the device or removing its covers causes risks, for example due to high voltage. This device should ONLY be repaired or uninstalled by qualified service personnel. For more information, contact your retailer.
Technical specifications:
Frequency range
EoC connector ................................................................2…1006 Mhz
Data transmission range ....................................................2…68 Mhz
TV output.....................................................................85…1006 MHz
Through loss .....................................................................................<0,5 dB
Output level min. 1…30 MHz.......................................................100 dBµV
Output level min 30…68 MHz .....................................................90 dBµV
Network.....................................................................up to 64 EoC-Modems
Gross data rate..............................................................................500 Mbps
Net data rate.................................................................................230 Mbps
Range .......................................................................................up to 700 m
Modulation....................................................4096/1024/256/64/16/8-QAM,
................................................QPSK, BPSK and ROBO modulation schemes
Encryption...................................................................................128 bit AES
Ethernet interface ...........................................................10/100/1000 Mbps
Network standards ............Home Plug AV IEEE1901, IEEE802.3, IEEE802.3u
WiFi network standard......................................................IEEE 802.11 b/g/n
Frequency range ......................................13 channels 2.412GHz~2.472GHz
Connections (TV/EoC) .................................................................2 x F socket
Connections (LAN) ...........................................................................2 x Rj45
LEDs .............................................................................Power/EoC/LAN/WiFi
Switching power supply .............................................110-230 V~ 50/60 Hz
Power consumption ...................................................................max. 5,5 W
Operating temperature ...............................................................0°C ~ 40°C
Dimensions ...................................................145 (B) x 82,5 (T) x 33 (H) mm
Corresponds to the standards ........................................EN 50083-2 Class A
At www.axing.com we provide the following aditional information
4 Operation instructions EoC
4 Software manual EoC
4 Application examples SMARTSolutions
EoC 2-01/2-00 premium -line
Ethernet over Coax
500 Mbps Modem
Quick Start Guide
State of the art 2016-04-27- Technical changes, design modifications, errors and misprints are subject to change without prior notice.
Manufacturer
AXING AG
Gewerbehaus Moskau
CH-8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
D-78239 Rielasingen
Scope of delivery
Ethernet over Coax Modem
Network cable 1.5 m (RJ-45)
Power cable with euro plug
CFA 8-00 terminating resistor
Operating manual
EoC 2-01
1
1
1
1
1
EoC 2-00
2
2
2
2
2
Product description
The EoC 2-01 modem allows feeding in of IP data signals in an existing coaxial antenna distribution (in the star or tree distribution).
The modems communicates in a Peer-to-Peer mode, each modem can communicate with each modem in the network. The data is transmitted through the return channel in the frequency range of 2...68 MHz.
The feeding in is performed via the return channel capable terrestrial input of a SAT multiswitch, via the terrestrial input of the antenna distributor structure or via a return channel capable antenna socket in the distribution network.
Two networkable devices can be connected to the LAN ports of a EoC modem. The IP network can be extended to up to 64 EoC devices.
The EoC 2-01 WiFi modem has a WLAN function which allows you to establish an internet connection on smart phones, tablet PCs and other
WLAN devices.
Installation (typical example)
All components in the distribution structure must support the return channel frequency range 2-68 MHz. This applies to SAT multiswitches, the passive distribution components and for antenna sockets.
4 Connect the to one of both RJ-45 LAN sockets of the EoC modem.
4
4
Connect the EoC socket to the available antenna network structure.
Connect the computer to one of both RJ-45 LAN sockets of the
4 other EoC modem.
Connect the EoC modem using the EoC-F socket to the antenna network structure.
Additionally, a TV or radio device can be connected to the TV-F socket of the EoC modem. If the terrestrial input of the SAT multiswitch is not assigned, it must be terminated with a 75 Ohm terminating resistor.
Ethernet over Coax in/out
HF/RF out
LAN
RJ 45
Power In
*
EoC 1-01/
EoC 2-01
TV
Coax
Up- and Downstream (Coax)
LAN
EoC network with encryption:
An EoC network consists of two or several (maximum 64) EoC modems which use the same network key.
Securing your EoC network allows you to protect the information sent via the network from unauthorized access.
4 Delete the default network key first.
4 Press the EoC Reset buttons on the rear side of all EoC devices for 5…8 seconds (until the Power LED flashes).
Pair and group formation
4
4
4
4
Press the EoC Reset button briefly (<1 s) on the rear side of the first EoC device.
The Power LED starts flashing.
Press the EoC reset buttons on the other devices within two minutes.
An invidual network key will be generate and the devices connect
4
4 to each other.
The EoC LED will flash for a short time
As soon as the procedure has been completed, both Power- and
EoC LEDs are again permanently lit.
Alternativly you can use the Security software to specify a key for your
EoC network (free download www.axing.com | Download).
Up- and Downstream (Coax)
LAN
Power
ON/OFF
LAN
RJ 45
WiFi
ON/OFF
120 s
After switching on
a
The green Power LED is lit
After approx. 10 seconds, the LEDs are lit/flashing as follows: a
EoC LED green (flashes in case of data traffic) a
LAN LED green (flashes in case of data traffic) a WiFi LED green (if WiFi is switched on) green (flashing in case of data traffic)
Standby Mode
The EoC modem switches after several minutes without data traffic to the
Standby mode. The Power LED is flashing green.
TV
WiFi
4 Switch WiFi ON. WiFi is active: a
Network name (SSID) = EoCxxxxxx
(xxxxxx = last six signs of the MAC adress) a
Encryption = WPA2 a
Password = 0000000000000000
You should replace the factory password by a new one!
WiFi network settings
The EoC 2-01 WiFi modem is configured using a web browser. a factory IP address = 192.168.100.111 a subnet mask = 255.255.255.0
a user name = admin a password = 000000
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project