Eickemeyer EICKSONIC II User Manual

Add to My manuals
28 Pages

advertisement

Eickemeyer EICKSONIC II User Manual | Manualzz

EICKsONIC II

Zahnsteinentfernungsgerät / ultrasonic scaler

Bedienungsanleitung / user Manual

TELEPHONE +49 7461 96 580 0 www.eickemeyer.com

Art. No. 176865

Bedienungsanleitung EickSonic II – DE

Inhaltsverzeichnis

1 Bestandteile und Installation des EickSonic II......................................................................................................... 4

1.1

Allgemeine Informationen .................................................................................................................................... 4

1.2

Bestandteile .............................................................................................................................................................. 4

1.3

Anwendungsbereiche ............................................................................................................................................. 4

1.4

Technische Spezifikationen ................................................................................................................................. 4

1.5

Installation ................................................................................................................................................................. 5

2 Arbeitsmöglichkeiten und Funktionen ....................................................................................................................... 7

2.1

Installation ................................................................................................................................................................. 7

2.2

Arbeitsmöglichkeiten und Funktionen ............................................................................................................. 7

3 Sterilisation und Pflege ................................................................................................................................................... 8

3.1

Sterilisation des Handstückes ............................................................................................................................. 8

3.2

Sterilisation der Spitze .......................................................................................................................................... 8

3.3

Sterilisation des Drehmomentschlüssels ......................................................................................................... 8

3.4

Reinigung des Drehmomentschlüssels und der Spitze ............................................................................... 8

3.5

Sterilisation und Reinigung von LED Lampe und Lichtkanal ................................................................... 8

4 Fehlerbehebung ................................................................................................................................................................. 9

5 Warnhinweise ................................................................................................................................................................... 11

5.1

Hinweise ................................................................................................................................................................... 11

5.2

Anwendungsausschluss ....................................................................................................................................... 11

5.3

Lagerung und Pflege ............................................................................................................................................ 12

5.4

Transport .................................................................................................................................................................. 12

6 Konformitätserklärung ................................................................................................................................................... 12

6.1

Das Gerät entspricht den folgenden Standards ........................................................................................... 12

6.2

EMC-Konformitätserklärung .............................................................................................................................. 12

7 Erklärung ............................................................................................................................................................................ 12

8 Erklärung der Symbole .................................................................................................................................................. 13

3/28

Bedienungsanleitung EickSonic II – DE

1 Bestandteile und Installation des EickSonic II

1.1

Allgemeine Informationen

Das EickSonic II Zahnsteinentfernungsgerät kann zur Zahnreinigung und Zahnbehandlung verwendet werden. Es besteht aus den folgenden Bauteilen:

Optical Handstück, noch komfortabler für den Klinikbetrieb.

Automatische Frequenzkorrektur stellt sicher, dass das Gerät immer mit der optimalen Frequenz arbeitet.

Das Handstück ist abnehmbar und kann bei 135 °C und 0,22 MPa autoklaviert werden.

Digital gesteuert, einfache Anwendung und effizientere Zahnsteinentfernung.

1.2

Bestandteile

Die Bestandteile des EickSonic II sind in der Packliste aufgeführt.

Das EickSonic II besteht aus elektronischen Bauteilen, wasserführenden Leitungen und Ultraschall-

Überträger.

1.3

Anwendungsbereiche

Das EickSonic II Zahnsteinentfernungsgerät dient zur Entfernung von Zahnstein in der Veterinärmedizin.

1.4

Technische Spezifikationen

Netz

Gerät

Frequenz

Ausgangsleistung

Sicherung Gerät

Sicherung Netzteil

Wasserdruck

Gewicht Gerät

Gewicht Netzteil

Arbeitsmodus

Schutzklasse Typ

Schutzgrad

Schutzgrad Wassereindringung

Arbeitsbedingungen

220–240 V (AC), 50/60 Hz, 150 mA

24 V (AC), 50/60 Hz, 1,3 A

28 kHz ±3 kHz

3–20 W

T 1,6 AL, 250 V

T 0,5 AL, 250 V

0,1–5 bar (0,01–0,5 MPa)

0,75 kg

1 kg

Kontinuierlich

Class II

Type BF equipment

Normales Gerät (IPX0),

Fußschalter: Tropfwassergeschützt (IPX1)

Umgebungstemperatur: 5–40 °C

Relative Luftfeuchtigkeit: ≤ 80 %

Luftdruck: 70–106 kPa

Das Gerät ist nicht geeignet für den Betrieb in Umgebung von entzündlichen Gasen oder Gas-Luft-

Gemischen, Sauerstoff oder Lachgas.

4/28

Bedienungsanleitung EickSonic II – DE

1.5

Installation

Die Bestandteile des EickSonic II sind auf Abbildung 1 abgebildet:

Abbildung 1

Abnehmbares Handstück (Abbildung 2)

Die Hauptbestandteile des abnehmbaren Handstückes sind auf Abbildung 2 dargestellt:

Abbildung 2

Noppe : Die Noppe kann abgenommen werden. Sie können die Noppe herausschrauben und den Stab mit

Alkohol regelmäßig reinigen.

Dekorativer Ring : Kann demontiert und mit Alkohol regelmäßig gereinigt werden. Kann unter hoher

Temperatur und Druck autoklaviert werden.

LED Lampe / Lichtkanal : Sollte mit destilliertem Wasser gereinigt und bei einer hohen Temperatur von

135 °C und hohem Druck von 0,22 MPa sterilisiert werden.

Handstück : Das Hauptstück des Ultraschall-Zahnsteinentfernungsgerätes kann bei hoher Temperatur unter Druck autoklaviert werden. Symbol: Autoklaviert (135 °C, 0,22 MPa)

Kabelanschluss : Verbindet das Handstück mit der Wasserquelle und Stromzufuhr der Haupteinheit (muss trocken gehalten werden).

5/28

Bedienungsanleitung EickSonic II – DE

Drehmomentschlüssel (Abbildung 3)

Die Struktur des Drehmomentschlüssels ist speziell so konstruiert, dass die Stärke der Spitzeninstallation richtig und korrekt kontrolliert werden kann. Sie kann auch garantieren, dass der Bediener die Spitze effektiv fest- oder losschraubt und seine Hände vor Kratzern schützt. Der Drehmomentschlüssel sollte in

Dampf bei 135 °C und 0,22 MPa sterilisiert werden. Der Drehmomentschlüssel muss nach der Sterilisierung an der Luft auskühlen, um eine Verbrühung bei der nächsten Bedienung zu vermeiden.

Er sollte in einem kühlen, trockenen und gelüfteten Raum aufbewahrt und sauber gehalten werden.

Abbildung 3

Setzen Sie den Schlüssel zur Bedienung so ein, wie in Abbildung 4 gezeigt:

Abbildung 4

Installation der Spitze : Halten Sie das Handstück, drehen Sie die Spitze mit dem Drehmomentschlüssel im Uhrzeigersinn. Drehen Sie, nachdem die Spitze anhält, noch zweimal im Kreis, dann ist die Spitze installiert.

Demontieren : Halten Sie das Handstück und drehen Sie den Drehmomentschlüssel gegen den

Uhrzeigersinn.

HINWEIS

Die folgenden Methoden der Sterilisierung sind verboten:

In Flüssigkeiten erhitzen

In Jod, Alkohol oder Glutaraldehyd eintauchen

In einem Ofen oder einer Mikrowelle erhitzen

EICKEMEYER ® übernimmt keine Verantwortung für die Beschädigung des Drehmomentschlüssels in einem jeglichen der oben genannten Fälle.

6/28

Bedienungsanleitung EickSonic II – DE

2 Arbeitsmöglichkeiten und Funktionen

2.1

Installation

1.

Öffnen sie die Verpackung und versichern Sie sich, dass alle Teile komplett sind.

2.

Nehmen Sie das Gerät aus der Verpackung und stellen es auf eine ebene, saubere Fläche.

3.

Drehen Sie den Wasser-Kontroll-Knopf im Uhrzeigersinn auf Maximum und den Vibrationsstärke

Knopf im Uhrzeigersinn in passende Position

4.

Stecken Sie das Fußschalterkabel in die dafür vorgesehene Buchse.

5.

Schließen Sie ein Ende des Wasserzuleitungsschlauches an den Wassereingang und das andere Ende mittels Konnektor an eine Wasserquelle.

6.

Schließen Sie das Handstück an: Schrauben Sie die Spitze mit dem Drehmomentschlüssel in das

Handstück, dann stecken Sie den Stecker des Handstückkabels korrekt hinein.

7.

Schließen sie das geräteseitige Stromkabel am Gerät an und das Netzteil am Stromnetz.

8.

Schalten Sie das Gerät ein. Die Kontrolllampe leuchtet.

2.2

Arbeitsmöglichkeiten und Funktionen

1.

Stellen Sie den Leistungs-Regulier-Schalter auf „1“ und stellen Sie sicher, dass die Vibrationsstärke auf „Minimum“ und der Wasserregulierungsknopf auf „Maximum“ stehen, bevor Sie das Gerät einschalten.

2.

Die normale Frequenz ist 28 ±3 kHz. Wenn das Wasser normal fließt, wird unter leichter Berührung und gleichbleibender Auf- und Ab-Bewegung Zahnstein entfernt ohne deutliche Hitzeentwicklung.

Überbeanspruchung und zu langes Verweilen auf einer Stelle sind unzulässig.

3.

Wählen sie eine Spitze passend zu der Anwendung und schrauben Sie diese fest mit beil. Schlüssel im Handstück ein (siehe Abbildung 4).

4.

Treten Sie auf den Fußschalter, die Spitze fängt an zu vibrieren und die LED Lampe oben auf dem

Handstück leuchtet. Nach dem Lösen des Fußschalters leuchtet die LED Lampe noch 10 Sek. lang.

5.

Vibrationsstärke: Stellen Sie die Stärke wie gewünscht ein (meistens in mittlerer Stellung). Da verschiedene Patienten unterschiedlich empfindlich sind, und die Festigkeit des Zahnfleisches ebenso variiert sollte die Stärke während der Behandlung ggf. angepasst werden.

6.

Wassermenge: Betätigen Sie den Fußschalter, die Spitze beginnt zu vibrieren, dann drehen Sie den

Wasserkontrollknopf um einen feinen Spraystrahl zu formen um das Handstück zu kühlen und die

Zähne zu reinigen.

7.

Die Spitze muss schwingen, bevor sie am Zahn angesetzt wird.

8.

Das Handstück kann wie ein Stift bewegt werden.

9.

Berühren Sie den Zahn mit der Spitze nur leicht, üben Sie nicht zu viel Druck aus, dies könnte die

Zähne verletzen oder die Spitze zerstören.

10.

Nach der Behandlung lassen Sie das Gerät ca. 30 Sekunden mit Wasserzufuhr weiterlaufen um das

Handstück und die Spitze zu reinigen.

11.

Schrauben Sie die Spitze ab und sterilisieren Sie diese.

HINWEIS

Schrauben Sie die Spitze nicht ab, wenn der Fußschalter aktiviert und die Maschine in Betrieb ist.

7/28

Bedienungsanleitung EickSonic II – DE

3 Sterilisation und Pflege

3.1

Sterilisation des Handstückes

Eine Sterilisation ist entweder bei 121 °C und 1 bar (0.1 MPa) oder 135 °C und 2.2 bar (0.22 MPa) möglich.

Schrauben Sie die Spitze nach jedem Einsatz ab.

Verpacken Sie das Handstück in steriler Gaze oder sterilem Beutel.

Lassen Sie das Handstück an der Luft abkühlen, bevor Sie es wieder verwenden.

HINWEIS

Entfernen Sie die Reinigungsflüssigkeit im Handstück mit Druckluft vor der Sterilisation.

Vergewissern Sie sich, dass die Spitze vom Handstück abgeschraubt wurde und nicht mit dem

Handstück sterilisiert wird.

Achten Sie darauf, dass die Außenseite des Handstückes während der Behandlung oder Sterilisation nicht beschädigt wird. Schmieren Sie kein schützendes Öl auf die Oberfläche des Handstückes.

Es gibt zwei wasserdichte “O”-Ringe am Ende des Handstückes. Achten Sie darauf, diese häufig mit dentalem Schmiermittel zu behandeln, da Die Sterilisation und das häufige Ein- und Ausstecken die

Lebensdauer vermindert. Ersetzen Sie die Ringe durch neue Exemplare, wenn sie beschädigt oder

übermäßig abgenutzt sind.

Die folgenden Sterilisationsmethoden sind nicht erlaubt:

Das Handstück in Flüssigkeiten erhitzen.

Das Handstück mit Desinfektionsmitteln, wie beispielsweise Alkohol, Jod oder Glutaraldehyd behandeln.

Das Handstück in einen Ofen oder einer Mikrowelle erhitzen.

3.2

Sterilisation der Spitze

Alle Spitzen können bei 135 °C autoklaviert werden.

3.3

Sterilisation des Drehmomentschlüssels

Der Drehmomentschlüssel kann bei hoher Temperatur und Druck sterilisiert werden.

3.4

Reinigung des Drehmomentschlüssels und der Spitze

Beide können mit einem Ultraschallreiniger gereinigt werden.

3.5

Sterilisation und Reinigung von LED Lampe und Lichtkanal

Säubern Sie die LED Lampe und den Lichtkanal mit destilliertem Wasser und sterilisieren Sie diese bei hoher Temperatur und hohem Druck nach jedem Einsatz.

8/28

Bedienungsanleitung EickSonic II – DE

4 Fehlerbehebung

Problem

Die Spitze vibriert nicht, und es fließt kein Wasser heraus, wenn der Fußschalter betätigt wird.

Die Spitze vibriert nicht, aber es fließt Wasser heraus, wenn der

Fußschalter betätigt wird.

Mögliche Ursachen

Der Kontakt des Stromrohrsteckers ist lose.

Lösungen

Stecken Sie den Stecker richtig in die Buchse ein.

Der Kontakt des Fußschalters ist lose.

Die Trafosicherung ist kaputt.

Die Sicherung im Hauptgerät ist kaputt.

Kontaktieren Sie EICKEMEYER

Kontaktieren Sie EICKEMEYER

®

®

Der Kontakt der Spitze ist lose.

Schrauben Sie die Spitze fest auf das Handstück (Abb. 4).

Der Kontakt des Verbindungssteckers zwischen dem Handstück und der Leiterplatte ist lose.

Mit dem Handstück stimmt etwas nicht.

Stecken Sie den Fußschalter fest in seine Buchse ein.

Kontaktieren Sie EICKEMEYER ®

Schicken Sie es zur Reparatur an

EICKEMEYER ® .

Mit dem Kabel stimmt etwas nicht.

Kontaktieren Sie EICKEMEYER ®

Die Spitze vibriert, aber es fließt kein Wasser heraus, wenn man den Fußschalter betätigt.

Nach Unterbrechung der

Stromzufuhr fließt immer noch

Wasser aus.

Das Handstück wird warm.

Die Wasserzufuhr ist zugedreht.

Drehen Sie den Wasserhahn auf

[Hinweis 1].

Es gibt Verunreinigungen im

Magnetventil.

Kontaktieren Sie EICKEMEYER ®

Das Magnetventil ist nicht normal.

Es gibt Verunreinigungen im

Magnetventil.

Schlagen Sie mit einem harten

Gegenstand auf das Magnetventil

[Hinweis 2].

Kontaktieren Sie EICKEMEYER ®

Es wird zu wenig Wasser ausgestoßen.

Die Vibration der Spitze wird schwach.

Die Wasserzufuhr ist zu niedrig eingestellt.

Die Wasserzufuhr ist zu niedrig eingestellt.

Erhöhen Sie die Wassermenge

[Hinweis 1].

Erhöhen Sie die Wassermenge

[Hinweis 1].

Der Wasserdruck ist zu niedrig.

Erhöhen Sie den Wasserdruck.

Das Wasserrohr ist blockiert.

Reinigen Sie die Wasserleitung mit der Multifunktionsspritze

[Hinweis 2].

Die Spitze wurde nicht fest auf das Handstück geschraubt.

Schrauben Sie die Spitze fest auf das Handstück (siehe Abb. 4).

9/28

Bedienungsanleitung EickSonic II – DE

Problem

Die Vibration der Spitze wird schwach.

Mögliche Ursachen

Die Spitze ist wegen der

Vibration lose.

Die Verbindung zwischen dem

Handstück und dem Kabel ist nicht trocken.

Die Spitze ist beschädigt

[Hinweis 3].

Der Knopf zur Steuerung der

Vibrationsintensität ist beschädigt.

Lösungen

Schrauben Sie die Spitze fest auf

(wie in Abb. 4 gezeigt).

Trocknen Sie die Verbindung mit dem Heißluftstrom.

Ersetzen Sie die Spritze durch eine neue.

Kontaktieren Sie EICKEMEYER ® Die Vibration ist zu stark, und der Knopf zur Steuerung der

Vibrationsintensität funktioniert nicht richtig.

Es sickert Wasser aus der

Verbindung zwischen

Handstück und Kabel.

Der wasserdichte „O“-Ring wurde beschädigt.

Ersetzen Sie ihn durch einen neuen „O"-Ring.

Falls das Problem so immer noch nicht gelöst werden kann, kontaktieren Sie bitte EICKEMEYER ® .

[Hinweis 1] Der Wasser-Kontroll-Knopf kann die Wassermenge entsprechend dem Symbol kontrollieren.

[Hinweis 2] Zur Reinigung des Wasserrohrs verwenden Sie die Multifunktionsspritze der Dentaleinheit

(wie in Abbildung 5 gezeigt):

Abbildung 5

Kappen sie das Wasserrohr mit einer Schere im Abstand von 10–15 cm vom Wassereingang.

Schalten Sie die Stromversorgung ein,

Verbinden Sie die Multifunktionsspritze der Dentaleinheit mit dem Wasserrohr.

Treten Sie auf den Fußschalter.

Stellen Sie den Schalter der Multifunktionsspritze an, drücken Sie Luft oder Wasser in die

Wasserleitung der Maschine, so können die Verunreinigungen, die dort festsitzen, entfernt werden.

[Hinweis 3] Falls die Spitze fest aufgeschraubt wurde und auch ein leichtes Sprühen auftritt, zeigen die folgenden Anzeichen, dass die Spitze beschädigt wurde: Die Vibrationsintensität und der Grad der

Wasserzerstäubung werden offensichtlich schwach. Während der Bedienung ertönt ein Summen, wenn die Spitze arbeitet.

10/28

Bedienungsanleitung EickSonic II – DE

5 Warnhinweise

5.1

Hinweise

Halten Sie das Zahnsteinentfernungsgerät vor und nach der Anwendung sauber.

Die Spitze, der Schlüssel und das Handstück müssen vor der Anwendung sterilisiert werden.

Schrauben Sie die Spitze nicht ab, wenn der Fußschalter aktiviert und die Maschine in Betrieb ist.

Die Spitzen müssen gut festgeschraubt sein. Es muss sichergestellt sein, dass ein feiner Wasserstrahl während der Anwendung an der Spitze austritt.

Wechseln sie die Spitze, wenn diese defekt oder verschlissen ist.

Die Spitze wird heiß, wenn das Gerät ohne Wasser betrieben wird. Stellen Sie sicher, dass es immer einen Wasserfluss gibt.

Verwinden oder schleifen Sie die Spitzen nicht.

Verwenden Sie zum Betrieb nur sauberes, klares Wasser. Ersetzen Sie das destillierte Wasser niemals mit Kochsalzlösung.

Wenn Sie Wasserquellen ohne Druck benutzen, stellen Sie sicher, dass sich diese mindestens einen

Meter über dem Gerät bzw. dem Kopf des Patienten befinden.

Vergewissern Sie sich, dass das Ende des Handstücks und der Kabelanschluss komplett trocken sind, bevor das Handstück in Betrieb genommen wird.

Reißen Sie während des Betriebs nicht am Kabel.

Reiben oder stoßen Sie das Handstück nicht.

Nach der Behandlung schalten Sie das Gerät ab, entfernen Sie den Netzstecker und stellen die

Wasserversorgung ab.

Der Netzstecker sollte so in die Steckdose gesteckt werden, so dass er im Notfall einfach herausgezogen werden kann.

Der Netzstecker ist NICHT wasserdicht. Halten Sie ihn trocken und entfernt von Wasser.

EICKEMEYER ® ist ausschließlich dann für die Sicherheit verantwortlich, wenn Wartungen und

Reparaturen und Änderungen von EICKEMEYER ® oder autorisierten Händlern durchgeführt wurden.

Das Schraubengewinde von Spitzen, die nicht von EICKEMEYER ® hergestellt werden, könnte ungenau, rostig und beschädigt sein, was das Schraubengewinde des Handstücks dauerhaft schädigt. Bitte verwenden Sie EICKEMEYER ® Spitzen.

5.2

Anwendungsausschluss

Der Gebrauch dieses Gerätes ist untersagt, wenn der Patient an Hämophilie leidet oder der behandelnde

Tierarzt Träger eines Herzschrittmachers ist.

11/28

Bedienungsanleitung EickSonic II – DE

5.3

Lagerung und Pflege

Das Gerät sollte vorsichtig behandelt werden und bei Raumtemperatur an einem trockenen und belüfteten Platz gelagert, aufgestellt und betrieben werden.

Das Gerät darf nicht in der Nähe von brennbaren, giftigen, ätzenden oder explosiven Gegenständen gelagert, aufgestellt und betrieben werden.

Das Gerät sollte in Räumen mit einer Luftfeuchtigkeit von unter 80 %, einem Luftdruck zwischen 50 kPa und 106 kPa und bei einer Umgebungstemperatur zwischen -10 °C und +50 °C gelagert, aufgestellt und betrieben werden.

Bei Nichtbenutzung sollte das Gerät abgeschaltet und vom Netz getrennt werden. Die Wasserversorgung sollte abgestellt sein. Wenn das Gerät für einen längeren Zeitraum nicht genutzt wird, sollte es einmal monatlich für ca. 5 min. in Betrieb genommen werden.

5.4

Transport

Das Gerät sollte während des Transports keinen Erschütterungen ausgesetzt werden. Stellen Sie es vorsichtig ab und drehen Sie es nicht auf den Kopf. Transportieren Sie das Gerät nicht gemeinsam mit gefährlichen Gütern. Vor Sonneneinstrahlung und Nässe schützen.

6 Konformitätserklärung

6.1

Das Gerät entspricht den folgenden Standards

EN 60601-1:2006 EN 60601-1-2:2007

EN 60601-1-6:2010 EN 62366:2008

EN 61205:1994 EN ISO 22374:2005

EN 62304:2006 EN 980:2008

EN ISO 9687:1995 EN 1041:2008

ISO 15223-1-2012 EN ISO 14971:2012

EN ISO 7405:2008 +A1:2003 EN ISO 17664:2004

EN ISO 17665-1:2006 EN ISO 10993-1:2009

EN ISO 10993-5:2009 EN ISO 10993-10:2010

6.2

EMC-Konformitätserklärung

Das Gerät wurde getestet und genehmigt entsprechend EN 60601-1-2 für EMC. Dies garantiert in keiner

Weise, dass dieses Gerät nicht durch elektromagnetische Störungen beeinträchtigt wird. Vermeiden Sie die Verwendung des Gerätes in hoher elektromagnetischer Umgebung.

7 Erklärung

EICKEMEYER ® behält sich das Recht vor, das Produkt ohne vorherige Ankündigung zu ändern. Die Bilder dienen nur als Referenz.

12/28

Bedienungsanleitung EickSonic II – DE

8 Erklärung der Symbole

Nur in geschlossenen

Räumen betreiben

Herstellungsdatum

Hersteller Wechselstrom (AC)

Autoklavierbar Schutzklasse II

Gerät vom Typ BF

Normales Gerät

Anschluss für Fußschalter

24 V Netzteileingang

Wiederverwertung

Vor Nässe schützen

Einstellung Wasserfluss

Zulässiger

Temperaturbereich

Feuchtebegrenzung

Wassereingangsdruck 0,01–0,5 MPa

Vorsichtig behandeln

Gebrauchsanweisung beachten

Luftdruck für Lagerung

13/28

User Manual EickSonic II – ENGL

Contents

1 Components and Installation of EickSonic II ......................................................................................................... 16

1.1

Instruction ................................................................................................................................................................ 16

1.2

Components ............................................................................................................................................................ 16

1.3

Scope of Application ............................................................................................................................................ 16

1.4

Main Technical Specifications ........................................................................................................................... 16

1.5

Installation ............................................................................................................................................................... 17

2 Product Function and Operation ................................................................................................................................ 19

2.1

Operation ................................................................................................................................................................. 19

2.2

Operation Method and Function Instruction ................................................................................................ 19

3 Sterilization and Maintenance .................................................................................................................................... 20

3.1

Sterilization of Handpiece .................................................................................................................................. 20

3.2

Sterilization of Scaling Tip ................................................................................................................................. 20

3.3

Sterilization of Torque Wrench ......................................................................................................................... 20

3.4

Cleaning of Torque Wrench and Scaling Tip ................................................................................................ 20

3.5

Sterilization and Cleaning of LED Lamp and Light Pipe .......................................................................... 20

4 Troubleshooting ............................................................................................................................................................... 21

5 Precaution .......................................................................................................................................................................... 23

5.1

Notice ........................................................................................................................................................................ 23

5.2

Contraindication .................................................................................................................................................... 23

5.3

Storage and Maintenance ................................................................................................................................... 24

5.4

Transportation ........................................................................................................................................................ 24

6 Declaration of Conformity ............................................................................................................................................ 24

6.1

Product conforms to the following Standards ............................................................................................. 24

6.2

EMC-Declaration of Conformity ........................................................................................................................ 24

7 Statement ........................................................................................................................................................................... 24

8 Symbol Instruction .......................................................................................................................................................... 25

15/28

User Manual EickSonic II – ENGL

1 Components and Installation of EickSonic II

1.1

Instruction

The EickSonic II ultrasonic dental scaler is mainly used for teeth cleaning and also an indispensable equipment for teeth disease prevention and treatment. It contains the following features:

Optical handpiece, more convenient for clinical operation.

Automatic frequency tracking ensures that the machine always works on the best frequency and performs more steadily.

The handpiece is detachable and can be autoclaved at the high temperature of 135 °C and pressure of

0.22 MPa.

Digitally controlled, easy operation and more efficient for scaling.

1.2

Components

The components of EickSonic II are listed in the packing list.

Product performance and structure: EickSonic II is composed of electrocircuit, water way and ultrasonic transducer.

1.3

Scope of Application

The ultrasonic scaler EickSonic II is used for the dental calculus elimination (for veterinary use only).

1.4

Main Technical Specifications

Power supply input

Main unit input

Output tip vibration frequency

Output power

Main unit fuse

Power supply fuse

Water pressure

Weight of main unit

Weight of power supply

Operating mode

Type of protection against electric shock

220 – 240 V (AC), 50/60 Hz, 150 mA

24 V (AC), 50/60 Hz, 1.3 A

28 kHz ±3 kHz

3 – 20 W

T 1.6 AL, 250 V

T 0.5 AL, 250 V

0.1

– 5 bar (0.01–0.5 MPa)

0.75 kg

1 kg

Continuous operation

Class II

Degree of protection against electric shock Type BF equipment

Degree of protection against harmful ingress

Ordinary equipment (IPX0), protection degree against water (used on the foot switch): of water

Working conditions

IPX1

Environment temperature: 5

Relative humidity: ≤ 80 %

– 40 °C

Atmospheric pressure: 70 – 106 kPa

The Equipment not suitable for being used in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide.

16/28

User Manual EickSonic II – ENGL

1.5

Installation

The components of the EickSonic II are shown in picture 1:

Picture 1

Detachable Handpiece (picture 2)

The main components of the detachable handpiece are shown in picture 2:

Picture 2

Nipple : the nipple can be removed. You can screw out the nipple and clean the pole with alcohol termly.

Decorative ring : can be disassembled and cleaned with alcohol regularly, can be autoclaved under the high temperature and pressure.

LED lamp / light pipe : Should be cleaned with purified water and sterilized under the high temperature of 135 °C and high pressure of 0.22 MPa.

Handpiece : the main part of the ultrasonic dental scaler can be autoclaved under the high temperature and pressure. Symbol: autoclaved (135 °C, 0.22 MPa)

Connector of the cable : connects the handpiece with the water source and power supply of the main unit

(has to be kept dry).

17/28

User Manual EickSonic II – ENGL

Torque Wrench (picture 3)

The torque wrench's structure is designed in special way which can control the strength of the scaling tip installation properly and correctly. It also can guarantee the operator screw or unscrew the scaling tip effectively and keep their hands away from being scratched.

Sterilize after each operation in steam with 135 °C and 0.22 MPa. The torque wrench must be cooled naturally after sterilization to avoid scalding when using next time.

Keep in a cool, dry and ventilated place and keep it clean.

Picture 3

For operation take the wrench as shown in picture 4:

Picture 4

Tip installation : Hold the handpiece, turn the tip toward clockwise direction with the torque wrench.

Turn two more circles after the tip stops, then the tip is installed.

Uninstall : Hold the handpiece, turn torque wrench toward counter-clockwise direction.

NOTICE

Forbidden sterilization ways are as following:

Braise in liquor

Dip in iodine, alcohol or glutaraldehyde

Torrefy in oven or micro-wave oven

EICKEMEYER ® is not responsible for the damage of the torque wrench for any cases listed in above.

18/28

User Manual EickSonic II – ENGL

2 Product Function and Operation

2.1

Operation

1.

Open the packing box, make sure that all the parts and accessories are complete according to the packing list.

2.

Take the main unit out of the box and put it on a stable plane.

3.

Turn the water control knob in clockwise direction to the maximum and turn the vibrating intensity control knob towards clockwise direction to a suitable position.

4.

Insert the plug of the foot switch to its socket.

5.

Connect one end of the water pipe to the water entrance, and the other end to the pure water source.

6.

Connect the handpiece: screw on the scaling tip to the handpiece by the torque wrench, then insert the connector of the cable to the handpiece correctly.

7.

Get through to the power.

8.

Press the power switch of the main unit, then the power indicator shines.

2.2

Operation Method and Function Instruction

1.

Make the scaler straight to the operator. Before turning on, please turn the vibrating intensity control knob to the minimum and water control switch to the maximum (turn three circles towards clockwise direction from the minimum to the maximum).

2.

The normal frequency is as high as 28 kHz +3 kHz. Under normal working condition light touch and a certain to-and-fro motion will eliminate the tartar without obvious heating. Overexertion and overstay are forbidden.

3.

Select a suitable scaling tip according to your request, screw it on to the handpiece tightly by the torque wrench (as showed in the picture 4).

4.

Step on the foot switch, the tip begins to vibrate, and the LED lamp on the top of the handpiece shines. Release the foot switch, the LED lamp keep shining for 10 seconds.

5.

Vibrating intensity: Adjust the vibrating intensity as you need, generally turn the knob to the middle grade. Because different patients have different sensitivity and the rigidity of the gingival tartar is not alike too, the vibrating intensity should be adjusted during the clinical treatment.

6.

Water adjustment: Step on the foot switch, the tip begins to vibrate, then turn the water control switch to form fine spray to cool down the handpiece and clean the teeth.

7.

The scaler tip has to vibrate before it can be used on a tooth.

8.

The handpiece can be handled in the same gesture as a pen in hand.

9.

Make the tip touch the surface of the teeth lightly, do not use too much pressure, or else the teeth will be hurt and the scaling tip will be damaged.

10.

After finishing operation, keep the machine working for 30 seconds with the water supply, so that the handpiece and the scaling tips can be cleaned.

11.

Pull out the handpiece and unscrew the scaling tip, make them be sterilized.

NOTICE

Do not pull out the handpiece when the foot switch is stepped on and the machine is working.

19/28

User Manual EickSonic II – ENGL

3 Sterilization and Maintenance

3.1

Sterilization of Handpiece

The optional autoclave temperature and pressure:

Sterilization at 121 °C and 1 bar (0.1 MPa) or 135 °C and 2.2 bar (0.22 MPa).

Pull out the handpiece and unscrew the scaling tip after every operation.

Pack the handpiece with sterile gauze or bag.

Reuse the handpiece after it cools naturally, in case of scalding hand.

NOTICE

Clear the cleaning liquid in the handpiece by compressed air before sterilization.

Be sure that the scaling tip has been unscrewed from the handpiece, and it is not sterilized with others.

Please pay attention that whether the outer of the handpieces damaged during the treatment or sterilization, do not smear any protective oil on the surface of handpiece.

There are two waterproof "O" rings at the end of the handpiece. Please lubricate them with dental lube frequently, as sterilization and repeating pulling and inserting will reduce their lifespan. Once they are damaged or worn excessively, please replace them with new ones.

The following sterilizing methods are forbidden:

Put the handpiece into any liquid for boiling.

Put the handpiece in disinfectors such as alcohol, iodine or glutaraldehyde.

Put the handpiece in oven or microwave oven for baking.

3.2

Sterilization of Scaling Tip

All scaling tips can be autoclaved with 135 °C.

3.3

Sterilization of Torque Wrench

The torque wrench can be sterilized under high temperature and pressure.

3.4

Cleaning of Torque Wrench and Scaling Tip

Both of them can be cleaned with an ultrasonic cleaner.

3.5

Sterilization and Cleaning of LED Lamp and Light Pipe

Clean the LED lamp and Light pipe with purified water and sterilize them under high temperature and high pressure after every operation.

20/28

User Manual EickSonic II – ENGL

4 Troubleshooting

Fault

The scaling tip does not vibrate and there is no water flowing out when stepping on the foot switch.

The scaling tip does not vibrate but there is water flowing out when stepping on the foot switch.

Possible causes

The power pipe plug is in loose contact.

The foot switch is in loose contact.

The fuse of transformer is broken.

Solutions

Make the plug insert to the socket well.

Insert the foot switch to its socket tightly.

Contact EICKEMEYER ®

The fuse in the main unit is broken.

Contact EICKEMEYER ®

The tip is in loose contact. Screw the tip on the handpiece tightly (picture 4).

The connect plug between the handpiece and the circuit board is in loose contact.

Contact EICKEMEYER ®

The scaling tip does not vibrate but there is water flowing out when stepping on the foot switch.

Something is wrong with the handpiece.

Something is wrong with the cable.

Send it to EICKEMEYER ® to repair.

Contact EICKEMEYER ®

The scaling tip vibrates but there is no water flowing out when stepping on the switch.

The water control switch is turned off.

There is impurity in the solenoid valve.

Turn on the water control switch [Note 1].

Contact EICKEMEYER ®

The solenoid valve is abnormal. Percuss the solenoid valve by some hard things [Note 2].

There is impurity in the solenoid valve.

Contact EICKEMEYER ® There is still water flowing out after the power is off.

The handpiece generates heat. The water control switch is in a low grade.

The amount of spouting water is too little.

The water control switch is in a low grade.

The water pressure is not high enough.

The water pipe is blocked.

Turn the water control switch to a higher grade [Note 1].

Turn the water control switch to a higher grade [Note 1].

Make the water pressure higher.

Clean the water line by multifunction syringe [Note 2].

The vibration of the tip becomes weak.

The tip has not been screwed on to the handpiece tightly.

Screw on the tip to the handpiece tightly (as shown in picture 4).

21/28

User Manual EickSonic II – ENGL

Fault

The vibration of the tip becomes weak.

The vibration is too strong and the vibrating intensity control knob is malfunction.

Possible causes

The tip is loose by because of vibration.

The coupling between the handpiece and the cable is not dry.

The tip is damaged [Note 3].

The vibrating intensity control knob is damaged.

Solutions

Screw on the tip tightly

(as shown in picture 4).

Dry it by the heated wind.

Replace with a new one.

Contact EICKEMEYER ®

There is water seeping from the coupling between the handpiece and the cable.

The waterproof "O" ring was damaged.

Replace with a new "O" ring.

If the problem still cannot be solved yet, please contact EICKEMEYER ® .

[Note 1] The water control knob can adjust the water volume according to the symbol.

[Note 2] To clean the water pipe with the multi-function syringe of the dental unit (as showed in the picture 5):

Picture 5

Snip the water pipe with scissors at a distance of 10–15 cm from the water entrance.

Turn on the power switch, get through to the power.

Connect the multi-function syringe of dental unit to the water pipe.

Step on the foot switch.

Turn on the switch of the multi-function syringe, press the air or water into the water line in the machine, then the impurity blocked in the water line can be eliminated.

[Note 3] If the scaling tip has been screwed on tightly and there is fine spray too, the following phenomena show that the scaling tip was damaged:

The vibrating intensity and the water atomization degree become weak obviously. When operating, there is some buzz when the scaling tip is working.

22/28

User Manual EickSonic II – ENGL

5 Precaution

5.1

Notice

Keep the scaler clean before and after operation.

The handpiece, scaling tip and torque wrench must be sterilized before every treatment.

Do not screw the scaling tip when stepping on the foot switch.

The scaling tip must be fastened and there must be fine spray coming out from the tip when operating.

Change a new one when the tip is damaged or worn excessively.

While the scaler is working, the heat of the scaling tip will become higher if there is no water flowing out. Please keep the water flow smoothly.

Do not make the tip twist or rub it.

Do not use an impure water source. Never replace the distilled water with physidogical saline.

When using a water source without hydraulic pressure, the water surface should be one meter higher than the head of the patient.

Be sure that the connecting end of handpiece and the socket of the connector of cable are complete dried before handpiece installation.

Do not pull the cable emphatically in operating.

Please do not rub or knock the handpiece.

After operation, turn off the power, then pull out the plug.

Please put the power plug into the socket easy to pull out, to make sure it can be pulled out in emergency.

The power supply is NOT waterproof. Please keep it dry and away from the water.

EICKEMEYER ® is only responsible for the safety when maintenance, repair and change are done by

EICKEMEYER ® or our authorized distributors.

The screw thread of the scaling tips that were produced by some other manufacturer may be coarse, rusty and collapsed; this will damage the screw thread of the handpiece irretrievably. Please use

EICKEMEYER ® scaling tips.

5.2

Contraindication

The use of this equipment is not allowed with patients who have haemophilia and if the treating veterinarian has a heart pacemaker.

23/28

User Manual EickSonic II – ENGL

5.3

Storage and Maintenance

The equipment should be handled carefully and lightly. Be sure that it is far from the vibration, and is installed or kept in a cool, dry and ventilated place.

Do not put the machine together with the articles that are combustible poisonous, caustic, or explosive.

This equipment should be reserved in a room where the relative humidity is ≤ 80 %, atmospheric pressure is 50 kPa to 106 kPa and the temperature is -10 °C to +50 °C.

Please turn off the power switch and pull out the power line plug when the equipment is not used. If the machine is not used for a long time, please make it get through to the power and water once per month for five minutes.

5.4

Transportation

Excessive impact and shake should be forbidden in transportation. Lay it carefully and lightly and do not invert it. Do not put it together with dangerous goods. Avoid solarisation and getting wet in rain and snow during transportation.

6 Declaration of Conformity

6.1

Product conforms to the following Standards

EN 60601-1:2006 EN 60601-1-2:2007

EN 60601-1-6:2010 EN 62366:2008

EN 61205:1994 EN ISO 22374:2005

EN 62304:2006 EN 980:2008

EN ISO 9687:1995 EN 1041:2008

ISO 15223-1-2012 EN ISO 14971:2012

EN ISO 7405:2008 +A1:2003 EN ISO 17664:2004

EN ISO 17665-1:2006 EN ISO 10993-1:2009

EN ISO 10993-5:2009 EN ISO 10993-10:2010

6.2

EMC-Declaration of Conformity

The device has been tested and homologated in accordance with EN 60601-1-2 for EMC. This does not guarantee in any way that this device will not be affected by electromagnetic interference. Avoid using the device in high electromagnetic environment.

7 Statement

All rights of modifying the product are reserved to the manufacturer without further notice. The pictures are only for reference.

24/28

User Manual EickSonic II – ENGL

8 Symbol Instruction

Date of manufacture

Manufacturer

Class II equipment

Type BF applied part

Ordinary equipment

Connection for the food switch

Use indoor only

Alternating current

Can be autoclaved

24 V AC power supply socket

Recovery

Keep dry

Adjustment for the water flow

Temperature limitation

Humidity limitation

Water entrance pressure 0.01 MPa to 0.5 MPa

Handle with care

Follow user manual

Atmospheric pressure for storage

25/28

Notes:

26/28

User Manual EickSonic II – ENGL

User Manual EickSonic II – ENGL

Notes:

27/28

GERMANY

EICKEMEYER KG

Eltastraße 8

78532 Tuttlingen

T +49 7461 96 580 0

F +49 7461 96 580 90

E [email protected]

www.eickemeyer.de

CANADA

EICKEMEYER Inc.

250 Briarhill Dr.

Stratford, Ont. Canada

N5A 7S2

T +1 519 273 5558

F +1 519 271 7114

E [email protected] www.eickemeyerveterinary.com

DENMARK

EICKEMEYER ApS

Lysbjergvej 6, Hammelev

6500 Vojens

T +45 7020 5019

F +45 7353 5019

E [email protected]

www.eickemeyer.dk

ITALY

EICKEMEYER S.R.L.

Via G. Verdi, 8

65015 Montesilvano (PE)

T +39 085 935 4078

F +39 085 935 9471

E [email protected]

www.eickemeyer.it

NETHERLANDS

EICKEMEYER B.V.

Bedrijventerrein

Pavijen-West Bellweg 44

4104 BJ Culemborg

T +31 345 58 9400

F +31 345 58 9401

E [email protected]

www.eickemeyer.nl

POLAND

EICKEMEYER Sp. z o.o.

Al. Jana Pawła II 27

00-867 Warszawa

T +48 22 185 55 76

F +48 22 185 59 40

E [email protected]

www.eickemeyer.pl

SWITZERLAND

EICKEMEYER AG

Sandgrube 29

9050 Appenzell

T +41 71 788 23 13

F +41 71 788 23 14

E [email protected]

www.eickemeyer.ch

UNITED KINGDOM

EICKEMEYER Ltd.

3 Windmill Business Village

Brooklands Close

Sunbury-on-Thames

Surrey, TW16 7DY

T +44 20 8891 2007

F +44 20 8891 2686

E [email protected]

www.eickemeyer.co.uk

advertisement

Related manuals

advertisement