OCU DP OPTION MODULE
Part Number 1200068L1
Part Number 1200068L1#HS
OCU DP PLUG-ON BOARD
Part Number 1200083L1
USER MANUAL
61200.068L1-1C
November 1996
901 Explorer Boulevard
Huntsville AL 35806-2807
Phone: (205) 971-8000
© 1996 ADTRAN, Inc.
All Rights Reserved.
Printed in USA.
OCU DP OPTION MODULE
TABLE OF CONTENTS
1. Introduction ........................................................................................................
1
1.1 OCU DP Overview ..........................................................................................
1
1.2 Functional Description ....................................................................................
1
Features .............................................................................................................
1
OCU DP Option Module Specifications .......................................................
2
1.3 Physical Description ........................................................................................
4
Figure 1. OCU DP Option Module ..............................................................
4
2. Installation ..........................................................................................................
5
2.1 Unpack & Inspect ............................................................................................
5
2.2 Installing The Option Module .......................................................................
5
Figure 2. Installing Option Module .............................................................
6
2.3 WarrantyAnd Customer Service ...................................................................
7
2.4 Wiring .............................................................................................................
8
Table A. Eight-Position Modular Jack Interface. ........................................
8
2.5 Power-Up Testing and Initialization .............................................................
9
3. Operation ............................................................................................................ 10
3.1 Overview ............................................................................................................ 10
3.2 Front Panel ........................................................................................................ 10
Indicators/Buttons .......................................................................................... 10
3.3 Menu Structure ................................................................................................ 10
Figure 3. TSU 100 Main Menu ...................................................................... 10
OCU DP Menus Are All Submenus ..................................................................... 11
2)PORTS Status, Submenu of 1)Status ................................................................. 11
7)PORT CONFIG, Submenu of 2)CONFIG ......................................................... 12
3)FACTORY RESTORE, Submenu of 3)UTIL ..................................................... 14
7)PORT UTILITY, Submenu of 3)UTIL ................................................................ 14
2)RUN SELF TEST, Submenu of 4)TEST ............................................................. 15
3)PORT Test, Submenu of 4)TEST ........................................................................ 15
Figure 4. Diagram of Loopbacks .................................................................. 16
Appendix I OCU DP Failure Messages ............................................................... 18
Failure Messages At Power-Up ............................................................................ 18
OCU DP Alarm Messages ..................................................................................... 18
November 1996 61200.068L1-1C i
ii 61200.068L1-1C November 1996
1. INTRODUCTION
1.1 OCU DP OVERVIEW
The Office Channel Unit Dataport (OCU DP) is one of the Option Modules available for use with the
ADTRAN TSU 100. The OCU DP is an all-rate Office
Channel Unit Dataport. It provides signal conversion from any of the rates on the customer loop side to a single DS0 time slot. The OCU DP should be selected for use with the connection of DDS or Switched 56
DSU/CSUs or other equipment which utilizes a DDS interface. The OCU DP provides an interface between the T1 Multiplexer and a DSU/CSU over a 4-wire loop, up to 18,000 feet in length of 26 AWG cable. This interface permits the combination of DDS lines into a single T1 stream.
1.2 FUNCTIONAL
DESCRIPTION
The OCU DP is designed to fit in the option slot of the TSU 100 and is subject to its operation and control.
The OCU DP is configured from the front panel of the
TSU 100 or by an external personal computer (PC) program. The internal menus for its configuration are a part of the OCU DP module and are automatically installed when the OCU DP is plugged into the unit.
F
EATURES
November 1996
• Operates using one DS0
• 2.4, 4.8, 9.6, 19.2, 38.4, 56, 64 kbps dedicated rates
• Supports Switched 56 dial-up digital service
• Compatible with DDS secondary channel services at rates ranging from 75 to 2400 bps, depending on the primary channel rate
• 45dB range at all rates
• Transmit attenuation available for short loops
• OCU loopback toward TSU Network Interface (NI)
(front panel, remote, inband)
• Sealing current reversal to initiate loopback at the
CSU (front panel, remote, inband)
61200.068L1-1C 1
• PRT/LCL bidirectional loopback toward the TSU
Network Interface (NI) and the DSU/CSU
• Zero code suppression
• Quality monitor/auto line disconnect
• Latching Loopback enable/disable
• Selectable hardware/software algorithms for
Switched-56 operation
• Interface Connector-RJ48C
The 19.6 kbps feature is patented by INC, patent
#4,862,480. The 45 dB range feature is patented by
ADTRAN, patent #4,759,035. The quality monitor/
auto line disconnect feature is patented by ADTRAN, patent #5,450,441.
OCU DP O
PTION
M
ODULE
S
PECIFICATIONS
Loop Interface
Data Rate
4-wire (TX Pair and RX Pair)
2.4, 4.8, 9.6, 19.2, 38.4, 56 kbps including secondary channel rates and 64 kbps (clear channel)
Signal Format
TX Output
Amplitude
Bipolar, return-to-zero, 50% duty cycle
±
1.5V peak
±
10% for rates 2.4, 4.8,
19.2, 38.4, 54 and 64 kbps
±
0.75V peak
±
10% for 9.6 kbps
TX/RX Source
Impedance 135
Ω ±
20%
Dynamic Range 0 to 45 dB loops loss for all rates measured at a frequency of half the data rate
Sealing Current 4 to 20 mA DC with polarity reversal capability
2 61200.068L1-1C November 1996
Capacity
Tests
Connector
One DS0 (user configurable)
Power-on circuit test
CSU loopback initiation - (sealing current reversal)
OCU loopback (loopbackinternal toward MUX) PRT/
LCL (bidirectional loopback)
RJ48C
November 1996 61200.068L1-1C 3
1.3 PHYSICAL
DESCRIPTION
The OCU DP, see Figure 1, is an option module which plugs into the option slot in the rear of the TSU
100.
OCU DP
Port X.1
DDS.
NX 56/64
PORT X.2
V.35
Figure 1. OCU DP Option Module
The OCU DP rear panel includes a plastic plug over a cutout for additional connectors. This allows a "plug-on" card to be added to the OCU DP module.
The PORT X.1 indication is linked to the port numbering philosophy of the TSU 100 product family. The X represents the slot number, and the .1 indicates the port number. For the TSU 100 application, there is only one option slot. Therefore the port designation for the OCU DP port will be 1.1. If added, the plug on card port designation would be 1.2. These port numbers will appear in the front panel LCD menu displays.
4 61200.068L1-1C November 1996
2. INSTALLATION
2.1 UNPACK & INSPECT
Carefully inspect the OCU DP module for any shipping damages. If damage is suspected, file a claim immediately with the carrier and then contact
ADTRAN customer service. If possible, keep the original shipping container for use in shipping the
OCU DP Module back for repair or for verification of damage during shipment.
ADTRAN S
HIPMENTS
I
NCLUDE
• The OCU DP Option Module
• The OCU DP Option Module User's Manual
(To be inserted into main TSU 100 User's Manual)
C
USTOMER
P
ROVIDES
• Cable for connection to DSU/CSU
2.2 INSTALLING THE
OPTION MODULE
CAUTION
Power to the TSU 100 should be OFF when installing the OCU DP Module, PN 1200.068L1.
The OCU DP Option Module PN1200.068L1#HS, is hot replaceable and can be installed in the TSU 100 with the
power On.
P
LACEMENT OF THE
OM
Figure 2
is representative of the action required for proper placement of the Option Module.
• Remove the cover plate from the TSU 100 rear panel.
• Slide the option module into the rear panel until it is positioned firmly against the front of the TSU 100.
• Fasten the thumb-screws at both edges of the option module.
November 1996 61200.068L1-1C 5
P
OWER
C
ONNECTION
Each OCU DP module derives power from the base TSU 100 unit. Power to the TSU 100 is supplied by a captive eight foot power cord.
Cover Plate
TSU 100
Option Module
Figure 2. Installing Option Module
6 61200.068L1-1C November 1996
2.3 WARRANTY AND
CUSTOMER SERVICE
ADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its published specifications or fails while in service.
For detailed warranty, repair and return information refer to the ADTRAN Equipment Warranty, Repair and Return Policy Procedure in the TSU 100 User's
Manual.
Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN.
For Service, RMA requests or more information, see the last page of this manual.
November 1996 61200.068L1-1C 7
2.4 WIRING
The OCU DP offers one connector for a DDS interface.
Connector Type (USOC)= RJ48C
PN= AMP # 555164-1
Table A. Eight-Position Modular Jack Interface
PINOUT CONNECTORS
FOR EIGHT-POSITION MODULAR JACK INTERFACE
PIN
1
2
3, 4, 5, 6
7
8
NAME
TIPRX
RING RX
UNUSED
TIPTX
RINGTX
DESCRIPTION
RECEIVE DATA FROM THE DSU
RECEIVE DATA FROM THE DSU
SEND DATA TOWARDS THE DSU
SEND DATA TOWARDS THE DSU
8 61200.068L1-1C November 1996
2.5 POWER-UP TESTING
AND INITIALIZATION
The OCU DP option module executes a self test during the power-up sequence, as described in the
TSU 100 User's Manual. No initialization input is required. Automatically, upon power-up, any previously configured setting for the OCU DP is restored.
When the self testing is complete and the configuration is successfully restored, it will be indicated by the illumination of the green "OK" LED in the MOD-
ULE group on the front panel. (See the section Front
Panel Operation in the TSU 100 User's Manual.) If the
OCU DP module fails one or more of the self tests, a message is displayed on the front panel during powerup. (See the section Power Up Testing and Initialization
in the
TSU 100 Manual) Specific failures of the OCU
DP module are shown in the appendix OCU DP
Failure Messages. If any alarms are detected during operation, it will be indicated by the illumination of the red "ALARM" LED in the MODULE group on the front panel.
November 1996 61200.068L1-1C 9
3. OPERATION
3.1 OVERVIEW
The OCU DP module is controlled as part of the
TSU 100 using the same methods as described in the user's manual.
3.2 FRONT PANEL
I
NDICATORS
/B
UTTONS
Please refer to the description of the TSU 100 front panel indicators and buttons in the user's manual.
3.3 MENU STRUCTURE
The OCU DP menus appear as a subset of and operate the same as menus for the TSU 100. The menus are accessed by selecting 1.1 OCU DP under the PORT menu items.
Figure 3
shows the TSU 100 Main Menu with the
PORT selections shaded.
The
TSU 100 User's Manual's appendix TSU 100
Menu Tree is a complete menu diagram.
10
MAIN MENU
1)STATUS
2)CONFIG
1)NETWORK (NI)
2)UNIT
3)MAP XCHNG
4)MAP IN USE
5)DS0 MAP A
6)DS0 MAP B
7)PORT CONFIG
3)UTIL
4)TEST
1)NETWORK TESTS
2)RUN SELFTEST
3)PORT TEST
Figure 3. TSU 100 Main Menu
1)NI PERF REPORTS
2)PORTS STATUS
3)ACTIVE ALARMS
4)VIEW HISTORY
1)ENTER PASSCODE
2)TIME/DATE
3)FACT RESTORE
4)REINIT UNIT
5)UNIT ID
6)SOFTWARE REV
7)PORT UTILITY
61200.068L1-1C November 1996
OCU DP MENUS
ARE ALL SUBMENUS
The OCU DP menus are accessed from and operated the same as menus for the TSU 100. As can be noticed from the shaded menu items in Figure 3, the
OCU DP items are submenu choices of the four main menus.
Each of the OCU DP sub menu items is discussed in the following paragraphs. All are accessed by the same method.
Operation
With the cursor on one of the four main menu choices
Press:
ENTER
or the number key
Results: display of the first two submenu items with the cursor on the first item.
Use: the down scroll key to place the cursor on the desired item
Press:
ENTER
Results: display of the first two submenu choices.
2)PORTS STATUS,
SUBMENU OF 1)STATUS
This menu item is used to display active status information about the OCU DP. There are three fields that report information. The display of an asterisk (*) indicates an item is active.
*
O P E N I D L E A D I S
Open An asterisk will be present if the DDS loop is open or wired incorrectly.
IDLE An asterisk will be present if the OCU is detecting Control Mode Idle (CMI) from the DDS loop.
ADIS An asterisk will be present if the Quality
Monitor Autodisconnect feature is enabled and the OCU has received enough improper violations to disconnect the DDS loop.
November 1996 61200.068L1-1C 11
7)PORT CONFIG,
SUBMENU OF 2)CONFIG
The 7)PORT CONFIG menu item is used for configuration of the OCU DP Passthru Option Module.
Operation
With the cursor on main menu item 2)CONFIG
Press:
ENTER
or the number 2 key
Results: display of the first two Configuration submenu items with the cursor on 1)NETWORK
Use:
(NI) the down scroll key to place the cursor on
7)PORT CONFIG
Press:
ENTER
Results: only the bottom line of the LCD changes display
Use: the scroll keys to identify 1.1 OCU DP
7 ) P O R T C O N F I G
P O R T : 1 . 1 O C U D P
12
To select
Press:
ENTER
Results: the first of eight submenu items
Continue with standard operating procedures.
RATE - Sets the data rate of the OCU DP.
Choices - 2.4, 4.8, 9.6, 19.2, 38.4, 56.0 DDS,
56.0 SW, 64
SEC CHAN - Enables or disables the use of a secondary channel with all data rates excluding
64 kbps.
Choices - OFF or ON
QUAL MON - Quality monitor function/Auto Disable Function. Allows the OCU DP to monitor the data it receives from the DDS loop. If it detects violations in 7 out of 20 consecutive seconds, it ignores the data it receives and sends abnormal station code toward the NI. Normal operation will automatically be restored upon receipt of 30 consecutive error free seconds.
61200.068L1-1C November 1996
Choices - OFF or ON
ZCS - Zero Code Suppression may be used to prevent a channel of zeros when running 56K data rate with secondary channel ON. ZCS is not used for 64 kbps data rate.
Choices - OFF or ON
A/B SIGNL - Selects either a software or hardware algorithm to be used for SW56 operation.
The OCU DP decodes signalling from the network and passes this to the loop as either CMI code or data mode. The default method of decoding signalling from the network is a software technique. If the C bit (bit 8) is 0 in any of the last seven data bytes, signalling is decoded as a 0 (onhook). If bit 8 is a 1 in all of the last seven data bytes, signalling is decoded as a 1 (off-hook).
If the hardware (HW) option is enabled, signalling is decoded from the A and B bits in frames
6 and 12 of the T1 data.
Choices - SW or HW
LTCHING LBACK - Enables the OCU DP response to the latching OCU and Channel loopback commands and performance of the requested test configuration.
Choices - ENABLED or DISABLED
TX LEVEL - Sets the Transmit Signal out of the OCU
DP to either Normal or Attenuated. For short line lengths it may be necessary to attenuate the transmit signal if the signal is large enough to saturate the DSU/CSU equipment being used.
Choices - NORMAL or REDUCED 10dB
November 1996 61200.068L1-1C 13
3)FACT RESTORE,
SUBMENU OF 3)UTIL
This menu item is used to restore the factory default setting for all OCU DP option module parameters.
Operation
Follow standard operating procedure to access the 3)UTIL menu items.
With the cursor on 3)FACT RESTORE
Press: the ENTER key
Results: the unit returns to the opening main menu with all factory preset defaults are restored.
7)PORT UTILITY,
SUBMENU OF 3)UTIL
The 7)PORT UTILITY menu item is primarily used to access the display of the current software information for each port installed in the unit. This information is required when requesting assistance from ADTRAN customer service or when updates are needed.
Operation
Follow standard operating procedure to access the 3)UTIL menu items.
With the cursor on 7)PORT UTILITY
Press: the ENTER key
Results: display of the first available port.
Use: the up and down scroll keys to identify 1.1
OCU DP
7 ) P O R T U T I L I T Y
P O R T : 1 . 1 O C U D P
14
To select
Press:
ENTER
Results: display of the option card name and the software version installed.
OCU DP REVA
Press: the CANCEL key to exit or to select another port.
61200.068L1-1C November 1996
2)RUN SELF TEST,
SUBMENU OF 4)TEST
This menu item is used to execute both the TSU
100's internal test and the OCU DP's internal test.
This is the same test as is executed upon power-up.
The results of the self test are displayed on the LCD.
For additional information on Self test, consult the chapter Operation in the TSU 100 User's Manual.
Follow standard operating procedure to access the 4)TEST menu items.
With the cursor on 2)RUN SELFTEST
Press: the ENTER key
Results: a changing display in the LCD showing the test result.
3)PORT TEST,
SUBMENU OF 4)TEST
This menu item is used to activate tests of the selected data ports. Selecting the OCU DP displays two Loopback tests available for this option module.
Operation
Follow standard operating procedure to access the 4)TEST menu items.
With the cursor on 3)PORT TEST
Press: the ENTER key
Results: display of the first available port.
Use: the up and down scroll keys to select 1.1
OCU DP
3 ) P O R T T E S T
P O R T : 1 . 1 O C U D P
November 1996
To select
Press:
ENTER
LOOPBACK - This item activates the loopback function on the OCU DP module.
On the OCU DP, the CSU loopback initiates a sealing current reversal. Upon detecting this rever-
61200.068L1-1C 15
T 1
sal, the DDS CSU (connected to the OCU DP over a 4wire loop) should loop data back toward the NI.
The OCU loopback loops the data mapped to the
OCU DP back toward the network interface of the controller. Using the loopback in conjunction with an external BERT driving the Network Interface, will exercise the entire data path from the Network Interface
(NI) through the OCU DP option module and back out the NI. See Figure 4, Diagram of Loopbacks.
TSU 100
OCU DP
Network Interface
(NI)
(Controller)
4-wire DDS
DSU/CSU
PRT/LCL OCU CSU
Figure 4. Diagram of Loopbacks
The PRT/LCL bidirectional loopback loops the data mapped to the OCU DP back to the network interface of the controller. It also loops data from the
DSU/CSU back to the DSU/CSU. If the DSU/CSU is capable of sending a test pattern, it can be used with this loopback to verify integrity of the 4-wire DDS loop.
To deactivate the Loopback, OFF must be selected under the 1.1 OCU DP submenu.
16 61200.068L1-1C November 1996
November 1996 61200.068L1-1C 17
APPENDIX I
OCU DP FAILURE MESSAGES
FAILURE MESSAGES
AT POWER-UP
The following messages indicate a probable part failure on the OCU DP Module.
EPROM
SRAM
EPROM ERROR
Static RAM ERROR
OCU DP ALARM
MESSAGES
The following message indicates an alarm condition on the OCU DP Module.
OPEN LOOP
not able to detect sealing current flowing. DSU/CSU not connected or incorrect wiring.
18 61200.068L1-1C November 1996
November 1996 61200.068L1-1C 19
Index
A
active status information 11
C
Configuration.
See PORT CONFIG
Customer Service 7
D
data ports.
See Port Test default setting.
See Fact Restore
Description 1
Features 1
Functional 1
Physical 4
I
F
Fact Restore 13
Front Panel 10
Indicators/Buttons 10
Initialization 9
Installation 5
Figure, Installing Option Module 6
Placement of the OM 5
Power Connection 5
L
Loopbacks Diagram 16
M
Menu Operation 11
Menu Structure 10
Messages
Alarm Messages 18
Failure Messages 18
Modular Jack Pinout Connectors 8
20 61200.068L1-1C November 1996
O
OCU DP Menus 11
Operation Overview 10
Overview 1
Features 1
Functional Description 1
Interfaces 2
Specifications 2
P
Physical Description 4
PORT CONFIG 12
A/B SIGNL, soft/hardware algorithm 13
LTCHING LBACK, latching/Channel loopback 13
QUAL MON, quality monitor 12
RATE, data rate 12
SEC CHAN, secondary channel 12
TX LEVEL, Transmit Signal 13
ZCS, Zero Code Suppression 13
Port Test 15
PORT UTILITY 14
PORTS Status 11
Power-Up Testing 9
R
Return Material Authorization (RMA) 7
Run Self Test 15
S
self test 15 software.
See Port Utility
Specifications 2 status information, active 11
T
TSU 100 Main Menu 10
W
Warranty 7
Wiring 8
November 1996 61200.068L1-1C 21
22
Product Support Information
Presales Inquiries and Applications Support
Please contact your local distributor, ADTRAN
Applications Engineering, or ADTRAN Sales:
Applications Engineering (800) 615-1176
Sales (800) 827-0807
Post-Sale Support
Please contact your local distributor first. If your local distributor cannot help, please contact ADTRAN
Technical Support and have the unit serial number available.
Technical Support (800) 726-8663
Repair and Return
If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Return Material Authorization (RMA) department to issue an RMA number. For information regarding equipment currently in house or possible fees associated with repair, contact RMA directly at the following number:
RMA Department (205) 971-8722
Identify the RMA number clearly on the package
(below address), and return to the following address:
ADTRAN, Inc.
RMA Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
RMA # _____________
61200.068L1-1C November 1996
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 14 3. Operation
- 14 3.1 Overview
- 14 3.2 Front Panel
- 14 Indicators/Buttons
- 14 3.3 Menu Structure
- 14 Figure 3. TSU 100 Main Menu
- 15 OCU DP Menus Are All Submenus
- 15 2)PORTS Status, Submenu of 1)Status
- 16 7)PORT CONFIG, Submenu of 2)CONFIG
- 18 3)FACTORY RESTORE, Submenu of 3)UTIL
- 18 7)PORT UTILITY, Submenu of 3)UTIL
- 19 2)RUN SELF TEST, Submenu of 4)TEST
- 19 3)PORT Test, Submenu of 4)TEST
- 20 Figure 4. Diagram of Loopbacks
- 22 Appendix I OCU DP Failure Messages
- 22 Failure Messages At Power-Up
- 22 OCU DP Alarm Messages