- No category
advertisement
PD – 309 / 2605 Series
User’s Manual
Rev. Original
FCC Notes:
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested an found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against interference when operated in a commercial environment.
Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures to correct the interference.
Warranty Limits:
Warranty terminates automatically when any person other than the authorized technicians opens the machine. The user should consult his/her dealer for the problem happened. Warranty voids if the user does not follow the instructions in application of this merchandise. The manufacturer is by no means responsible for any damage or hazard caused by improper application.
About This Manual:
Posiflex has made every effort for the accuracy of the content in this manual. However,
Posiflex will assume no liability for any technical inaccuracies or editorial or other errors or omissions contained herein, nor for direct, indirect, incidental, consequential or otherwise damages, including without limitation loss of data or profits, resulting from the furnishing, performance, or use of this material.
This information is provided “as is” and Posiflex Technologies, Inc. expressly disclaims any warranties, expressed, implied or statutory, including without limitation implied warranties of merchantability or fitness for particular purpose, good title and against infringement.
The information in this manual contains only essential hardware concerns for general user and is subject to change without notice. Posiflex reserves the right to alter product designs, layouts or drivers without notification. The system integrator shall provide applicative notices and arrangement for special options utilizing this product. The user may find the most up to date information of the hardware from web sites: http://www.posiflex.com or http://www.posiflex.com.tw
All data should be backed-up prior to the installation of any drive unit or storage peripheral. Posiflex will not be responsible for any loss of data resulting from the use, disuse or misuse of this or any other Posiflex product.
All rights are strictly reserved. No part of this documentation may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, or otherwise, without prior express written consent from
Posiflex Technologies, Inc. the publisher of this documentation.
© Copyright Posiflex Technologies, Inc. 2008
All brand and product names and trademarks are the property of their respective holders.
P/N: 19430903010
Part 1
BRIEF INTRODUCTION
THE PRODUCT
The PD-309/ PD-2605 is a pole mount customer display option designed for Posiflex mini slim base of KS-2010 or DT-20X POS terminals. It is delivered in separate carton for the host system and shall be installed per instructions in this manual.
FEATURES
•
LCD (Liquid crystal display) with dark blue character and yellow green back-light for PD-309
•
Bright VFD (vacuum fluorescent display) with green filter for PD-
2605
•
Two-line display with 20 characters per line
•
Easy viewing characters (6.0 mm by 9.66 mm for PD-309 / 9.03 mm by 5.25 mm for PD-2605)
•
Long life and trouble free operation
•
15°
•
Display frame can rotate horizontally 270
°
freely
•
Selectable command emulation modes including PST and EPSON command emulation modes for PD-309
•
Various command emulation modes selectable by DIP switch for
PD-2605
•
Support 13 Code Pages of 128 characters each for PD-2605
•
Support 12 international character sets of 12 characters each for
PD-2605
•
Simple installation
•
Selectable between Serial (RS232) interface model and USB interface model
•
Supports UPOS 1.8 and is WEPOS ready for PD-2605
Part 2
INSTALLATION GUIDES
HOST SYSTEM PREPARAION
For serial interface (RS232) PD-309 or PD-2605 to be used in KS-
2010 or DT-20X series, you have to adjust during power off the internal jumper of the host system to supply 5 V DC to the COM port selected for the serial interface pole display. This adjustment has to be done by a qualified electronic technician following guide from relevant technical manual. The default communication protocol should be set to 9600 bps, none parity, 8 data bits, 1 stop bit with hardware handshaking on CTS. The power for the USB interface type pole display is supported through the USB connection. However, should these customer displays are to be connected through an USB HUB instead of a direct USB port of the system, the HUB must be powered by a separate power adaptor otherwise there could be the power shortage problem.
INSTALLATION
For the KS-2010 series with mini slim base or
DT-20X POS system, the LCD customer display PD-309/U or
Base for KS-2010 Bottom of DT-20X the VFD PD-2605/U can be attached to either rear corner of bottom plate. Refer to the pictures in Pix. 1 at right. Use the 3 attached screws to fix the
Pix. 1
metal base plate of the PD to bottom of mini slim base or
DT-20X at the circled positions. For mini slim base
Connect the interface cable to go into the base through cable exit arrowed in Pix. 2 at right to the main unit. For
DT-20X arrange the interface cable to go through under bottom to connector area arrowed in Pix. 1 at above right.
Pix. 2
COMMAND EMULATION MODE SETUP
(FOR PD-2605)
DIP switch window
Pix. 3
Now please check the back of PD-2605 display head as in the above left picture in Pix. 3. There is a small piece of plastic cover for the “DIP switch window”. Slide the cover downward but don’t pull it off otherwise you may have to practice for inserting it back. You can find 6 positions of
Part 3
DIP switches in this window. Adjust for the appropriate command mode used by the application program according to below table. Switch position counts from left to right and “ON” means pushed up as indicated in the above right part in Pix. 3.
Switch Position
1 2 3 4 5 6
ON OFF OFF ON OFF OFF
Command Mode
ON OFF ON ON OFF OFF
ON
ON
OFF
OFF
ON
ON
OFF OFF OFF
ON OFF OFF ON ON OFF
OFF ON OFF
ON OFF ON ON ON OFF
ADM
Aedex
Epson
Futaba
Noritake
UTC
The factory default command mode is set to Noritake mode for normal delivery. Please change it to Epson mode if OPOS or UPOS driver is used for the application program.
POWER ON SIGN
With interface cable connection well installed (and with COM port power set for serial models), turn on the Posiflex POS system, a firmware identifier as power on sign will appear on the pole display screen for a while to indicate that pole display is self-tested O.K. and ready to work.
USING THE CUSTOMER DISPLAY
INTERRFACE SELECTION
This series of customer display is designed to serve in Posiflex POS systems with RS232 interface models and with USB interface models. It is advisable to well study the I/O port availability of the host system before determining which interface model to be used.
When a RS232 (serial) interface model of PD-309 / 2605 is used, the jumper on main board of the host system must be modified to supply power to the COM port designated for PD-309 / 2605. Whenever the RS232 interface
PD-309 / 2605 is to be removed from the host system, consequently the jumper has to be changed back to neutralize the power support COM port, otherwise
damage could occur!
The USB interface model of PD-309 / 2605 should be connected directly to an USB port and must not be through any non-self-powered USB
HUB to get power through the USB port itself and there is no need for other special arrangement.
Part 4
COMMAND MODE SELECTION GUIDE
The below table provides some comparison for selection on command mode to be used in the application program for PD-2605 if it is not yet determined.
Mode
Cursor
Default mode
User defined font
Brightness control
ADM Aedex Epson Futaba Noritake UTC
N.A. N.A. Invisible
Blinking
Block
Blinking
Block
Blinking
Block
(DP)
N.A. N.A. Over/W V. scroll Over/W PT
N.A.
NO
N.A.
NO
2 chars N.A.
YES YES
2 chars
YES
2 chars
(PT)
YES (DP)
Leading code change NO
Code page select NO
Auto scroll message NO
YES
NO
NO
NO
YES
NO
YES
YES
YES
YES
YES
YES
YES (PT)
YES
YES (PT)
Timer clock NO NO YES NO NO YES (PT)
For PD-309 it is always the Epson command mode at power on. It can enter or exit the PST command mode through software command.
DRIVER INSTALLATION
FOR RS-232 INTERFACE MODELS:
For direct I/O control over the serial interface (RS232) models, you have to send all commands (listed later in this manual) under communication protocol 9600 bps, none parity, 8 data bits, 1 stop bit with hardware handshaking on CTS signal to the COM port used. No other driver installation is required.
FOR USB INTERFACE MODELS:
Copy the driver and library from Posiflex Product Information CD or
DVD under \Drivers\PD23_26U to your system or download from web site http://www.posiflex.com.tw/Download%20list.asp?Status=1&Series_Name=P
D%20Series&Model_Name=PD-2300U. Follow instructions given in the file
“README.TXT” to send commands (listed later in this manual) and data to the customer display under the programming language.
FOR OPOS APPLICATION:
Find the subfolder \Drivers\UPOS\OPOS of the Posiflex Product
Information CD or DVD or download it from web site http://www.posiflex.com.tw/Download%20list.asp?Status=1&Series_Name=U
POS&Model_Name=OPOS and execute the file “SETUP.EXE” to install the
OPOS Control Manager. To add the customer display under OPOS control please set in OPOS Control Manager device name “PD3x-Line Display” in the top row. For RS-232 models, select the COM port in the 3 rd
row and set baud rate to “9600” in 4 th
row as in the left sample screen below. Select “USB” in
Part 5
3 rd
row for USB interface models as in the right sample picture below.
SPECIFICATION
Number of digits
Dot matrix
Digit height
Digit width
Display color
OPTICAL
20 digits/row, 2 rows
5 X 7 dots
9.66 mm (PD-309) / 9.03 mm (PD-2605)
6.0 mm (PD-309) / 5.25 mm (PD-2605)
Dark blue (PD-309) / Green (PD-2605)
MECHANICAL
Total Height
Display Head Height
Display Head Width
Display Head Depth
Case color
283 mm
57.5 mm
196.6 mm
39.5 mm
Black
ELECTRICAL
Power from interface port of KS or DT system:
+ 5VDC 1A
ENVIRONMENTAL
Operating temperature 0
°
to + 40
°
C
Storage temperature -10
°
to + 60
°
C
Operating humidity 20% to 85%, non-condensing
Storage humidity 5% to 90%, non-condensing
WARNING: If the user opens the pole display housing to make any modification, all the product warranty will be voided.
NOTE: Please refer to Posiflex Product Information CD or DVD or visit our web http://www/posiflex.com.tw for further information when needed.
Part 6
APPENDIX
APPLICABLE COMMANDS
(FOR PD-309)
EPSON COMMAND MODE (POWER ON DEFAULT):
NAME HEX CODES FUNCTION
BS <08> Move Cursor Left
HT <09>
LF <0A>
HOM <0B>
Move Cursor Right
Move Cursor Down
Move Cursor To Home Position
CLR
CR
CAN
ESC t
<0C>
<0D>
<18>
ESC = <1B><3D><n>
ESC @ <1B><40>
<1B><74><n>
US MD1 <1F><01>
US MD2 <1F><02>
US MD3 <1F><03>
US LF <1F><0A>
US CR <1F><0D>
Clear Display Screen
Move Cursor To Left Most Position
Clear Cursor Line
Select Peripheral Device / Command Mode n=1 pass through (should not be used) n=2, 3 (not required) n=4 switch to PST command mode
Initialize Display
Disable / Enable Euro Dollar Sign n = 0, 19
Specify Overwrite Mode
Specify Vertical Scroll Mode
Specify Horizontal Scroll Mode
Move Cursor Up
Move Cursor To Right Most Position
US $
<1F><24><n>< m>
Move Cursor To Specified Position n = 1 ~ 20 m = 1, 2
US @ <1F><40>
US B <1F><42>
Show Version
Move Cursor To Bottom Position
US C <1F><43><n> Cursor On / Off, n = 1, 0
US E <1F><45><n>
Blink Display Screen n = 0 ~ 255
PST COMMAND MODE:
HEX CODES FUNCTION
<01> Set Pass Through Flag (should not be used)
<06> <N
1
> <N
2
> Change Leading Code
<14> <01> Wraparound Mode (Default)
<14> <02> Vertical Scroll Mode
<14> <03> Insert Mode
Part 7
<14> <04>
<14> <08>
<14> <09>
<14> <0A>
<14> <0B>
<14> <0C>
<14> <0D>
<14> <0E>
<14> <10>
<14> <11>
<14> <12>
Overwrite Mode (Default)
Back Space
Move Cursor Right
Move Cursor Down
Move Cursor Left
Delete Character
Move Cursor To Left Most Position
Clear Display
Clear Line 1
Clear Line 2
Cursor Block Mode
<14> <13> Cursor Under Line Mode
<14> <15> <02> Clear Pass Through Flag
<14> <16> Switch To Epson Mode
<14> <17>
<14> <18>
Cursor On
Cursor Off
<14> <19> Reset
<14> <1A> <P> Move Cursor To Position P (P=0~13,14~27h)
<14> <1B> Move Cursor To Rightmost Position Of Line 1
<14> <1C> Move Cursor To Rightmost Position Of Line 2
The Euro Dollar Sign is designated at code <D5>h.
COMMAND CODES SUMMARY
(FOR PD-2605)
Command Function
ADM mode
0C
Clear Display
0D
0E
Carriage Return
Write Line 1
Command Function
10
1E
1F
Write Decimal Point
Write Field 1
Write Field 2
0F
Write Line 2
AEDEX mode
Attention code + Function code + data + CR
1
2
Display top
Display bottom
7
8
Stop trapping
Change attention code
Display whole area 4
6
On going scroll
One time scroll
9
EPSON mode
BS
HT
Move cursor left US ;
Move cursor right US <
LF
HOM
CLR
Move cursor down
Move cursor home
US E
US T
Clear display screen US X
Mark semicolon
Clear mark
Set/cancel blinking
Set and display counter
Brightness adjustment
Part 8
CR
CAN
US ,
Move cursor leftmost
Clear cursor line
Mark comma
ESC %
ESC &
ESC R
Set/cancel user-defined char.
Define user-defined char.
US MD1
Overwrite mode ESC ?
US MD2
Vertical scroll mode US @
US MD3
US LF
Horizontal scroll mode
Move cursor up
ESC =
ESC t
US CR
Move cursor rightmost
US B
US $
Move cursor specified
ESC @
Delete user-defined char.
Show firmware version
Select peripheral device
Select code page table
Move cursor to bottom
Initialize display
International character set
Display counter US . Mark period
FUTABA mode
1F
04 bb
Reset
US U
10 pp
Brightness control
13
Digit select
Cursor on
Cursor off
1E pp
Change code page
14
1C 0i
International character set
05
· · · 0D Moving sign
06 x1 x2
08
11 09
Change leading code 12 09
01
x1 x2 02
Set pass through flag 11 0A
Clear pass through flag
12 0A
0D
Back space
Horizontal tab
Vertical scroll up
Cursor up/down
Line feed
Carriage return
NORIRAKE mode
1B 49
0E
Reset
Clear
1B 54 nn
Cursor blinking Rate
15
1B 4C bb
Brightness control
16
Cursor on
Cursor off
Back space
1E pp
Change code page
08
International
1C 0i
character set
05
· · · 0D Moving sign
11 09
12 09
Horizontal tab
Vertical scroll up
06 x1 x2
01
Change leading code 11 0A
Set pass through flag 12 0A
Cursor up/down
Line feed
Part 9
x1 x2 02
Clear pass through flag
0C
1B 48 pp
Digit select
1B 43 ad x1
User defined fonts
~ x5
0D
Form feed
Carriage return
UTC Pass through mode Command [+data] [+CR]
ESC uA Top line message ESC uH Redefine graphic
ESC uA CR Clear top line
ESC uB CR Clear bottom line
ESC uIx
ESC uE
Display fonts
Set/Display time
ESC uB
ESC uD
Bottom line message ESC utcEx Change d mode
Continuous scrolling ESC utcFx Change RS mode
ESC uF Top line scroll once ESC RS * Direct to pole mode
UTC Direct to pole mode
EOT x
BS
HT
LF
Brightness
Back spacing
Horizontal tab
Line feed
DC4
CAN
EM
SUB x
Cursor off
Clear to end of line
Clear to end of display
Display fonts
CR
DLE
DC1
DC2
DC3
Carriage return
Display position
ESC d *
FS
Normal display mode GS
Vertical scroll mode RS
Cursor on
US
Pass thru mode
Flashing text start
Flashing text end
Clear display
Reset display
1
2
3
4
5
INTERNATIONAL CHARACTER SETS
(FOR PD-2605)
Hex code Country Hex code Country
0 USA 6 Italy
France
Germany
United Kingdom
Denmark I
Sweden
7
8
9
A
B
Spain
Japan
Norway
Denmark II
Ex-Jugoslavia
警告使用者
T31454
這是甲類的資訊產品,在居住的環
境 中 使 用 時 , 可 能 會 造 成 射 頻 干
擾,在這種情況下,使用者會被要
求採取某些適當的對策。
Part 10
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project