FCC Notes:

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested an found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against interference when operated in a commercial environment.

Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures to correct the interference.

Warranty Limits:

Warranty terminates automatically when any person other than the authorized technicians opens the machine. The user should consult his/her dealer for the problem happened. Warranty voids if the user does not follow the instructions in application of this merchandise. The manufacturer is by no means responsible for any damage or hazard caused by improper application.

About This Manual:

Posiflex has made every effort for the accuracy of the content in this manual. However,

Posiflex will assume no liability for any technical inaccuracies or editorial or other errors or omissions contained herein, nor for direct, indirect, incidental, consequential or otherwise damages, including without limitation loss of data or profits, resulting from the furnishing, performance, or use of this material.

This information is provided “as is” and Posiflex Technologies, Inc. expressly disclaims any warranties, expressed, implied or statutory, including without limitation implied warranties of merchantability or fitness for particular purpose, good title and against infringement.

The information in this manual contains only essential hardware concerns for general user and is subject to change without notice. Posiflex reserves the right to alter product designs, layouts or drivers without notification. The system integrator shall provide applicative notices and arrangement for special options utilizing this product. The user may find the most up to date information of the hardware from web sites: http://www.posiflex.com or http://www.posiflex.com.tw

All data should be backed-up prior to the installation of any drive unit or storage peripheral. Posiflex will not be responsible for any loss of data resulting from the use, disuse or misuse of this or any other Posiflex product.

All rights are strictly reserved. No part of this documentation may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, or otherwise, without prior express written consent from

Posiflex Technologies, Inc. the publisher of this documentation.

© Copyright Posiflex Technologies, Inc. 2008

All brand and product names and trademarks are the property of their respective holders.

P/N: 19430903010

Part 1

BRIEF INTRODUCTION

THE PRODUCT

The PD-309/ PD-2605 is a pole mount customer display option designed for Posiflex mini slim base of KS-2010 or DT-20X POS terminals. It is delivered in separate carton for the host system and shall be installed per instructions in this manual.

FEATURES

LCD (Liquid crystal display) with dark blue character and yellow green back-light for PD-309

Bright VFD (vacuum fluorescent display) with green filter for PD-

2605

Two-line display with 20 characters per line

Easy viewing characters (6.0 mm by 9.66 mm for PD-309 / 9.03 mm by 5.25 mm for PD-2605)

Long life and trouble free operation

15°

Display frame can rotate horizontally 270

°

freely

Selectable command emulation modes including PST and EPSON command emulation modes for PD-309

Various command emulation modes selectable by DIP switch for

PD-2605

Support 13 Code Pages of 128 characters each for PD-2605

Support 12 international character sets of 12 characters each for

PD-2605

Simple installation

Selectable between Serial (RS232) interface model and USB interface model

Supports UPOS 1.8 and is WEPOS ready for PD-2605

Part 2

INSTALLATION GUIDES

HOST SYSTEM PREPARAION

For serial interface (RS232) PD-309 or PD-2605 to be used in KS-

2010 or DT-20X series, you have to adjust during power off the internal jumper of the host system to supply 5 V DC to the COM port selected for the serial interface pole display. This adjustment has to be done by a qualified electronic technician following guide from relevant technical manual. The default communication protocol should be set to 9600 bps, none parity, 8 data bits, 1 stop bit with hardware handshaking on CTS. The power for the USB interface type pole display is supported through the USB connection. However, should these customer displays are to be connected through an USB HUB instead of a direct USB port of the system, the HUB must be powered by a separate power adaptor otherwise there could be the power shortage problem.

INSTALLATION

For the KS-2010 series with mini slim base or

DT-20X POS system, the LCD customer display PD-309/U or

Base for KS-2010 Bottom of DT-20X the VFD PD-2605/U can be attached to either rear corner of bottom plate. Refer to the pictures in Pix. 1 at right. Use the 3 attached screws to fix the

Pix. 1

metal base plate of the PD to bottom of mini slim base or

DT-20X at the circled positions. For mini slim base

Connect the interface cable to go into the base through cable exit arrowed in Pix. 2 at right to the main unit. For

DT-20X arrange the interface cable to go through under bottom to connector area arrowed in Pix. 1 at above right.

Pix. 2

COMMAND EMULATION MODE SETUP

(FOR PD-2605)

DIP switch window

Pix. 3

Now please check the back of PD-2605 display head as in the above left picture in Pix. 3. There is a small piece of plastic cover for the “DIP switch window”. Slide the cover downward but don’t pull it off otherwise you may have to practice for inserting it back. You can find 6 positions of

Part 3

DIP switches in this window. Adjust for the appropriate command mode used by the application program according to below table. Switch position counts from left to right and “ON” means pushed up as indicated in the above right part in Pix. 3.

Switch Position

1 2 3 4 5 6

ON OFF OFF ON OFF OFF

Command Mode

ON OFF ON ON OFF OFF

ON

ON

OFF

OFF

ON

ON

OFF OFF OFF

ON OFF OFF ON ON OFF

OFF ON OFF

ON OFF ON ON ON OFF

ADM

Aedex

Epson

Futaba

Noritake

UTC

The factory default command mode is set to Noritake mode for normal delivery. Please change it to Epson mode if OPOS or UPOS driver is used for the application program.

POWER ON SIGN

With interface cable connection well installed (and with COM port power set for serial models), turn on the Posiflex POS system, a firmware identifier as power on sign will appear on the pole display screen for a while to indicate that pole display is self-tested O.K. and ready to work.

USING THE CUSTOMER DISPLAY

INTERRFACE SELECTION

This series of customer display is designed to serve in Posiflex POS systems with RS232 interface models and with USB interface models. It is advisable to well study the I/O port availability of the host system before determining which interface model to be used.

When a RS232 (serial) interface model of PD-309 / 2605 is used, the jumper on main board of the host system must be modified to supply power to the COM port designated for PD-309 / 2605. Whenever the RS232 interface

PD-309 / 2605 is to be removed from the host system, consequently the jumper has to be changed back to neutralize the power support COM port, otherwise

damage could occur!

The USB interface model of PD-309 / 2605 should be connected directly to an USB port and must not be through any non-self-powered USB

HUB to get power through the USB port itself and there is no need for other special arrangement.

Part 4

COMMAND MODE SELECTION GUIDE

The below table provides some comparison for selection on command mode to be used in the application program for PD-2605 if it is not yet determined.

Mode

Cursor

Default mode

User defined font

Brightness control

ADM Aedex Epson Futaba Noritake UTC

N.A. N.A. Invisible

Blinking

Block

Blinking

Block

Blinking

Block

(DP)

N.A. N.A. Over/W V. scroll Over/W PT

N.A.

NO

N.A.

NO

2 chars N.A.

YES YES

2 chars

YES

2 chars

(PT)

YES (DP)

Leading code change NO

Code page select NO

Auto scroll message NO

YES

NO

NO

NO

YES

NO

YES

YES

YES

YES

YES

YES

YES (PT)

YES

YES (PT)

Timer clock NO NO YES NO NO YES (PT)

For PD-309 it is always the Epson command mode at power on. It can enter or exit the PST command mode through software command.

DRIVER INSTALLATION

FOR RS-232 INTERFACE MODELS:

For direct I/O control over the serial interface (RS232) models, you have to send all commands (listed later in this manual) under communication protocol 9600 bps, none parity, 8 data bits, 1 stop bit with hardware handshaking on CTS signal to the COM port used. No other driver installation is required.

FOR USB INTERFACE MODELS:

Copy the driver and library from Posiflex Product Information CD or

DVD under \Drivers\PD23_26U to your system or download from web site http://www.posiflex.com.tw/Download%20list.asp?Status=1&Series_Name=P

D%20Series&Model_Name=PD-2300U. Follow instructions given in the file

“README.TXT” to send commands (listed later in this manual) and data to the customer display under the programming language.

FOR OPOS APPLICATION:

Find the subfolder \Drivers\UPOS\OPOS of the Posiflex Product

Information CD or DVD or download it from web site http://www.posiflex.com.tw/Download%20list.asp?Status=1&Series_Name=U

POS&Model_Name=OPOS and execute the file “SETUP.EXE” to install the

OPOS Control Manager. To add the customer display under OPOS control please set in OPOS Control Manager device name “PD3x-Line Display” in the top row. For RS-232 models, select the COM port in the 3 rd

row and set baud rate to “9600” in 4 th

row as in the left sample screen below. Select “USB” in

Part 5

3 rd

row for USB interface models as in the right sample picture below.

SPECIFICATION

Number of digits

Dot matrix

Digit height

Digit width

Display color

OPTICAL

20 digits/row, 2 rows

5 X 7 dots

9.66 mm (PD-309) / 9.03 mm (PD-2605)

6.0 mm (PD-309) / 5.25 mm (PD-2605)

Dark blue (PD-309) / Green (PD-2605)

MECHANICAL

Total Height

Display Head Height

Display Head Width

Display Head Depth

Case color

283 mm

57.5 mm

196.6 mm

39.5 mm

Black

ELECTRICAL

Power from interface port of KS or DT system:

+ 5VDC 1A

ENVIRONMENTAL

Operating temperature 0

°

to + 40

°

C

Storage temperature -10

°

to + 60

°

C

Operating humidity 20% to 85%, non-condensing

Storage humidity 5% to 90%, non-condensing

WARNING: If the user opens the pole display housing to make any modification, all the product warranty will be voided.

NOTE: Please refer to Posiflex Product Information CD or DVD or visit our web http://www/posiflex.com.tw for further information when needed.

Part 6

APPENDIX

APPLICABLE COMMANDS

(FOR PD-309)

EPSON COMMAND MODE (POWER ON DEFAULT):

NAME HEX CODES FUNCTION

BS <08> Move Cursor Left

HT <09>

LF <0A>

HOM <0B>

Move Cursor Right

Move Cursor Down

Move Cursor To Home Position

CLR

CR

CAN

ESC t

<0C>

<0D>

<18>

ESC = <1B><3D><n>

ESC @ <1B><40>

<1B><74><n>

US MD1 <1F><01>

US MD2 <1F><02>

US MD3 <1F><03>

US LF <1F><0A>

US CR <1F><0D>

Clear Display Screen

Move Cursor To Left Most Position

Clear Cursor Line

Select Peripheral Device / Command Mode n=1 pass through (should not be used) n=2, 3 (not required) n=4 switch to PST command mode

Initialize Display

Disable / Enable Euro Dollar Sign n = 0, 19

Specify Overwrite Mode

Specify Vertical Scroll Mode

Specify Horizontal Scroll Mode

Move Cursor Up

Move Cursor To Right Most Position

US $

<1F><24><n>< m>

Move Cursor To Specified Position n = 1 ~ 20 m = 1, 2

US @ <1F><40>

US B <1F><42>

Show Version

Move Cursor To Bottom Position

US C <1F><43><n> Cursor On / Off, n = 1, 0

US E <1F><45><n>

Blink Display Screen n = 0 ~ 255

PST COMMAND MODE:

HEX CODES FUNCTION

<01> Set Pass Through Flag (should not be used)

<06> <N

1

> <N

2

> Change Leading Code

<14> <01> Wraparound Mode (Default)

<14> <02> Vertical Scroll Mode

<14> <03> Insert Mode

Part 7

<14> <04>

<14> <08>

<14> <09>

<14> <0A>

<14> <0B>

<14> <0C>

<14> <0D>

<14> <0E>

<14> <10>

<14> <11>

<14> <12>

Overwrite Mode (Default)

Back Space

Move Cursor Right

Move Cursor Down

Move Cursor Left

Delete Character

Move Cursor To Left Most Position

Clear Display

Clear Line 1

Clear Line 2

Cursor Block Mode

<14> <13> Cursor Under Line Mode

<14> <15> <02> Clear Pass Through Flag

<14> <16> Switch To Epson Mode

<14> <17>

<14> <18>

Cursor On

Cursor Off

<14> <19> Reset

<14> <1A> <P> Move Cursor To Position P (P=0~13,14~27h)

<14> <1B> Move Cursor To Rightmost Position Of Line 1

<14> <1C> Move Cursor To Rightmost Position Of Line 2

The Euro Dollar Sign is designated at code <D5>h.

COMMAND CODES SUMMARY

(FOR PD-2605)

Command Function

ADM mode

0C

Clear Display

0D

0E

Carriage Return

Write Line 1

Command Function

10

1E

1F

Write Decimal Point

Write Field 1

Write Field 2

0F

Write Line 2

AEDEX mode

Attention code + Function code + data + CR

1

2

Display top

Display bottom

7

8

Stop trapping

Change attention code

Display whole area 4

6

On going scroll

One time scroll

9

EPSON mode

BS

HT

Move cursor left US ;

Move cursor right US <

LF

HOM

CLR

Move cursor down

Move cursor home

US E

US T

Clear display screen US X

Mark semicolon

Clear mark

Set/cancel blinking

Set and display counter

Brightness adjustment

Part 8

CR

CAN

US ,

Move cursor leftmost

Clear cursor line

Mark comma

ESC %

ESC &

ESC R

Set/cancel user-defined char.

Define user-defined char.

US MD1

Overwrite mode ESC ?

US MD2

Vertical scroll mode US @

US MD3

US LF

Horizontal scroll mode

Move cursor up

ESC =

ESC t

US CR

Move cursor rightmost

US B

US $

Move cursor specified

ESC @

Delete user-defined char.

Show firmware version

Select peripheral device

Select code page table

Move cursor to bottom

Initialize display

International character set

Display counter US . Mark period

FUTABA mode

1F

04 bb

Reset

US U

10 pp

Brightness control

13

Digit select

Cursor on

Cursor off

1E pp

Change code page

14

1C 0i

International character set

05

· · · 0D Moving sign

06 x1 x2

08

11 09

Change leading code 12 09

01

x1 x2 02

Set pass through flag 11 0A

Clear pass through flag

12 0A

0D

Back space

Horizontal tab

Vertical scroll up

Cursor up/down

Line feed

Carriage return

NORIRAKE mode

1B 49

0E

Reset

Clear

1B 54 nn

Cursor blinking Rate

15

1B 4C bb

Brightness control

16

Cursor on

Cursor off

Back space

1E pp

Change code page

08

International

1C 0i

character set

05

· · · 0D Moving sign

11 09

12 09

Horizontal tab

Vertical scroll up

06 x1 x2

01

Change leading code 11 0A

Set pass through flag 12 0A

Cursor up/down

Line feed

Part 9

x1 x2 02

Clear pass through flag

0C

1B 48 pp

Digit select

1B 43 ad x1

User defined fonts

~ x5

0D

Form feed

Carriage return

UTC Pass through mode Command [+data] [+CR]

ESC uA Top line message ESC uH Redefine graphic

ESC uA CR Clear top line

ESC uB CR Clear bottom line

ESC uIx

ESC uE

Display fonts

Set/Display time

ESC uB

ESC uD

Bottom line message ESC utcEx Change d mode

Continuous scrolling ESC utcFx Change RS mode

ESC uF Top line scroll once ESC RS * Direct to pole mode

UTC Direct to pole mode

EOT x

BS

HT

LF

Brightness

Back spacing

Horizontal tab

Line feed

DC4

CAN

EM

SUB x

Cursor off

Clear to end of line

Clear to end of display

Display fonts

CR

DLE

DC1

DC2

DC3

Carriage return

Display position

ESC d *

FS

Normal display mode GS

Vertical scroll mode RS

Cursor on

US

Pass thru mode

Flashing text start

Flashing text end

Clear display

Reset display

1

2

3

4

5

INTERNATIONAL CHARACTER SETS

(FOR PD-2605)

Hex code Country Hex code Country

0 USA 6 Italy

France

Germany

United Kingdom

Denmark I

Sweden

7

8

9

A

B

Spain

Japan

Norway

Denmark II

Ex-Jugoslavia

警告使用者

T31454

這是甲類的資訊產品,在居住的環

境 中 使 用 時 , 可 能 會 造 成 射 頻 干

擾,在這種情況下,使用者會被要

求採取某些適當的對策。