CEILING CONCEALED TYPE AIR CONDITIONER INDOOR UNIT

INSTRUCTION

MANUAL

H-MRV

Ceiling Concealed Type Room Air Conditioner

AE072FCAKA

AE092FCAKA

AE122FCAKA

AE142FCAKA

AE182FCAKA

AE212FCAKA

AE242FCAKA

AE09~212FCAKA

AE072FCAKA

AE242FCAKA

Contents

Before Application

Cautions

Part Description

Important Points of Safety

Operating Instructions

AUTO,COOL, DRY,HEAT Operation

TIME Operation

Sleep Function

Health Function

Maintenance

Trouble Shooting

When Fault Occurs

Notice to Users

Indoor Unit Installation

Installation Precautions

Installation Procedure

Malfunction

Installation Check and Trial Run

0010573331

Please read this manual carefully before use.

Please keep it attentively for future use.

17-18

19

20

21-22

23-33

34-35

36

1-2

3-8

9-11

12

13-14

15

16

Cautions

1

Cautions

Indoor

DB C

WB C

Cooling outdoor

DB C

WB C

Heating

Rated Maximum Minimum

27 32 18

19 23 14

35 43 -5

Indoor

DB C

WB C

24 26 --

20 27 15

14.5 -- --

7 24 -15 outdoor DB C

WB C

6 18 --

2

D

AE072FCAKA

AE242FCAKA

AE092FCAKA , AE122FCAKA , AE142FCAKA , AE182FCAKA , AE212FCAKA have the Return air box (see the following picture) when shipping from the factory and they are back-side return air. During the installation, also can be changed to Down-side Return air according to the user's need.

AE09~212FCAKA

3

D

SWING

MODE

T E M P

ON

OFF

FAN

SLEEP

HEALTH FRESH

CLOCK

TIMER

SET

RESET

LIGHT LOCK

Left picture is a wired remote controller, which can be used on AE072FCAKA(wired control), AE092FCAKA

(wired control), AE122FCAKA(wired control),

AE142FCAKA(wired control),AE182FCAKA(wired control),AE212FCAKA(wired control), AE242FCAKA

(wired control). The remote controller can be purchased extrally.

Wired remote Controller using method:

1.Use one wired remote controller. See fig (1)

2.Also can buy a remote controller extrally, realize wired remote control + remote control dual control modes.

AUTO

ON

*

OFF

SET

ROOM C

MODE FAN SWING

TEMP HEALTH

CLOCK

TIMER

SET

SLEEP

FILTER RESET

RESET

ON/OFF

Wire remote controlller

Remote controlller (1)

Remote controlller is an accessory, to be ordered extrally

fig(1)

The right figure is a remote controller, which can be used on AE072FCAKA(remote control), AE092FCAKA(remote control), AE122FCAKA(remote control), AE142FCAKA

(remote control),AE182FCAKA(remote control),

AE212FCAKA(remote control), AE242FCAKA(remote control) and the matching remote control receiver

Remote control receiver using method :

Use remote controller control the remote control window of the remote control receiver.

B A

AUTO

OFF

H

HEALTH

MODE

T E M P

ON

OFF

FAN

SWING

TIMER

RESET CODE

LOCK

R

Remote receiver (2)

fig(2)

Remote controlller (2)

4

D

14 15 16 17 18 19

13

12

11

10

9

8

AUTO

MODE FAN SWING

TEMP HEALTH

20

29

22.Setting button

Used to confirm

the time of timer

and clock

23.Sleep button

7

6

SET

CLOCK

TIMER

SET

SLEEP

21

22

26

27

28

21.Clock button

Used to calibrate the time of timer and clock

Used to set Sleep state

5

4

3

2

1

1.ON/OFF button

Used to turn on/off unit

2.Temperature display

3.Clock display

4.Timer ON/OFF display

5.Humidity display

6.Air filter cleaning display

When there is too much dust collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet.

Auto

Low Fan Med Fan High Fan Auto

11.Fresh air state display

12.Humidifying state display

Working mode

Wire controller

Auto operation

Cooling operation

Dehumidifying operation

16.Electric heating display

17.Operation mode button

* just press the air filter reset button.

7.Super/Soft operation display

8.Fan speed display

9.Auto Swing display

10.Health state display

SUR

FILTER RESET

RESET

ON/OFF

13.Sleep state display

14.Network control display

15.Working mode display

23

24

25

30

25.Reset button

Heating operation

Fan operation

When the wire controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal

26.Air Filter Reset

button

Used to set working mode:

Auto, Cooling, Dehumidifying,

Heating, Fan

18.Fan speed button

Used to set fan speed: Low

Fan, Med Fan, High Fan, Auto

19.Swing button

Used to set Auto Swing or

Fixed air sending direction

20.Temperature Setting button

Used to set temperature, temperature range: 16 C~30

C

24.Time Adjusting

button

Used to adjust the time of timer and clock

After cleaning the air inlet, press this button, the unit can start to operate

27.Timer button

Used to set the mode of timer

28.Lock state display

29.Health

Used to control the generating oxygen function and negative ion-function

Note:

1.This model does not have the following related

display and function

5 6 7 9 11 12 14 16 26

30.Remote control window

Used to receive the remote control signal

2.The outdoor unit no oxygen-bar function or no negative ion

Calibration of clock

When turning on the unit for the first time, the clock should be calibrated. The method of calibration is:

1.Press ìClockî button, the Clock display ìAMî ìPMî will flash.

2.Press or to adjust time. For each press, the time will increase or decrease 1

* minute. If depressing the button, the time will increase or decrease rapidly.

3.After confirming the time, press ìSetî button, ìAMî or ìPMî will stop flashing,the

clock will begin to work.

5

D

Remote LCD display contents and key name and each key function introduction

31

23

22

21

20

19

18

17

16

15

8

1

2

3

SWING

MODE

HEALTH

CLOCK

T E M P

ON

OFF

FRESH

SET

FAN

SLEEP

24

25

26

27

28

29

9

10

11

1.ON/OFF button

Used to turn on/off unit

Note: Wired remote

controller his key have compl

cooling running function.

2.Operation mode button

Used to set working mode:

Auto, Cooling,

Dehumidifying,

Heating, Fan

3.Health

Used to control the generating oxygen function and negative ion-function

4.Clock button

Used to calibrate the time of timer and clock

5.Timer button

13.Setting button

Used to confirm

the time of timer

and clock

14.Lock button

Used to lock the operating key and LCD contents

15.Timer ON/OFF display

16.Fan speed display

Auto

Low Fan Med Fan High Fan Auto

17.Battery energy display

18.Clock display

19.Auto Swing display

20.Humidifying state display

21.Sleep mode display

22.Working mode display

4

12

13

Used to set the mode of timer

Working mode

Remote controller

5

TIMER

6.Time Adjusting button

Auto operation

6

7

RESET

LIGHT LOCK

14

30

7.Reset button

When the wire controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal

8.Swing button

Cooling operation

Dehumidifying operation

Heating operation

Fan operation

23.Health state display

Display when the health running

24.Electric heating display

25.Comfort running display

Used to set Auto Swing or

Fixed air sending direction

26.Fresh air state display

AUTO

ON

*

SET

ROOM

OFF

C

MODE

TEMP

CLOCK

TIMER

FAN

ON/OFF

SWING

HEALTH

SET

SLEEP

FILTER RESET

RESET

9.Temperature Setting button

Used to set temperature, temperature range: 16 C~30 C

10.Fan speed button

Used to set fan speed: Low

Fan, Med Fan, High Fan, Auto

27.Signal launch display

23.Temperature display

Used to display the setting temperature and room temp.

29.Lock state display

11.Sleep button

12.Fresh air

Used to set fresh air function

30.Light button

Used to realize control board

VFD light stable,light weaker, light shut off etc.

31.Signal lauch head

Remote controller

(Operation of remote controller)

Make sure that the remote controller is used within 7 meters from receiver window of the wire controller and there are no obstructions in between.

The remote controller or wire controller should be handled with care.

When operating the remote controller in an area where electronically controlled lights are installed or wireless handsets are used, move closer to the indoor unit as the function of the remote controller might be affected by signals from this equipment.

Note:

3.When using remote controller, first point it to the receiving window of wire controller, and then operate remote controller.A ìtickî tone will be uttered to indicate a right acceptance.

4.All the buttons except the sleeping button is no effective after wire controller received lock signal from remote controller.

6

D

11

12

13

14

Remote LCD display contents and key name and each key function introduction

4

6

21

AUTO ion

OFF

H

HEALTH

MODE

T E M P

ON

OFF

FAN

SWING

TIMER

RESET CODE

B A

LOCK

20

15

16

1.ON/OFF button

Used to turn on/off unit

2.Temperature Setting button

Used to set temperature, temperature range: 16 C~30 C

17

18

19

2

7

3.Health

Used to control the generating oxygen function and negative ion-function

4.Operation mode button

8

9

10

Used to set working mode:

Cooling, Dehumidifying,

Heating

5.Timer button

Used to set the mode of timer

6.Reset button

When the remote controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal

7.Fan speed button

Used to set fan speed

8.Swing button

Used to set Auto Swing or

Fixed air sending direction

9.Time Adjusting button

10.Lock button

Press on time lock all the key sand press another time concel the lock.

11.Working mode display

12.Fan speed display

Used to display the fan speed. After setting

"AUTO" function,air speed can auto change according to the temp. difference between the room temp. and setting temp.

13.Health running display

Used to display healthy running.

14.Timer ON/OFF display

Display Timing mode.

"Blank" No Timing

15.Signal display

Sending out signal to the remote receiver.

16.Temperature display

Display the setting temp.

value.

17.Lock display

Display the key have been locked.

18.Super/Soft operation display

19.Timing time display

Display timing open time or timing close time

20.Signal launch head

Use to send signal to the indoor unit receive window.

21.Code

Select remote control receive code(H-MRV Remote cnotrol type use A code)

Make sure that the remote controller is used within 7 meters from receiver window of the wire controller and there are no obstructions in between.

The remote controller or wire controller should be handled with care.

When operating the remote controller in an area where electronically controlled lights are installed or wireless handsets are used, move closer to the indoor unit as the function of the remote controller might be affected by signals from this equipment.

R

Note:

1.After change the battery, working condition resume as follows:

Working mode:cooling Temp. 26 C

Timming mode: normal Air speed: Auto

2.The units used in this manual no 8 18 functions. The health key can only control the negative generator.

7

D

Clock set

When unit is started for the first time, clock should be adjusted as follows:

Press CLOCK button, "AM"or "PM" flashes.

Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly.

After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.

Battery loading

Batteries are fitted as follows:

* *

* *

Remove the battery compartment lid

Slightly press and disengage the battery compartment lid marked with ì î and then hold the remote controller by the upper section and then remove the battery compartment lid by pressing in the direction of the arrow as shown in the figure above.

Loading the battery

Ensure that batteries are correctly placed in the compartment as required for positive and negative terminals.

Replacing the battery compartment lid

The battery compartment lid is reinstalled in the reverse sequence.

Display review

Press the button to see if batteries are properly fitted. If no display appears, refit the batteries.

Caution:

If the remote controller does not operate as designed after fitting new batteries of the same type, press the Reset button (marked ) with a pointed article.

Note:

It is recommended that the batteries be removed from the compartment if the remote controller is not used for an extended period.

The remote controller is programmed for automatic test of operation mode after the batteries are replaced. When the test is conducted, all icons will appear on the screen and then disappear if the batteries are properly fitted.

When the display become weak, this display no power in the battery, please change the battery.

2

5

4

3

1

1 .Emergency switch

2 .Power lamp

After open the unit, this lamp bright when the unite enter health running, the lamp change from orange to blue lamp.

3 .Timing lamp

When the unit been setting Timing running, this lamp bright.

4 .Running lamp

When the compressor working, this lamp bright.

5 .Indoor temp. sensor

Test the room temperature.

R

8

Important Points of Safety

The following four important points of safety and suggestions should be paid great attention:

!

Warning: Misuse may cause fatal result such as death or serious injury etc.

!

Attention: Misuse may cause human injury or damage of machine, in some case

fatal results.

: Content marked with this ìforbiddenî sign should be absolutely forbid-

den, otherwise may cause damage of machine and human injury of the

user.

!

: Content marked with this ìcompulsoryî sign should be executed comp-

ulsively, otherwise may cause damage of machine and human injury of

the user.

Comply with the following important points of safety.

Put these important points of attention and suggestions nearby and convenient for reference in need.

Hand over this instruction manual to new user if you resell this machine.

!

Entrusted Installation

Installation of the machine should be entrusted to certified person of after service. Unauthorized installation may cause water leakage, electric shock or fire hazard for improper operation.

!

To prevent leakage of refrigerant, let certified person of after service do it.

Leakage of refrigerant over certain consistence may result in shortage of oxygen. Enough precautions

MUST

be done to avoid oxygen shortage in case of refrigerant leaking if the room where the airconditioner is installed is small.

!

Warning

The power supply must be fitted with earth line to ensure valid earthing of the air-conditioner. No or incomplete earthing connection may cause the risk of electric shock.

!

Test run

After indoor units are installed,all cassettes hinded models should be tested.when the units are confirmed to be normal,other fitments can be installed.

!

9

Important Points of Safety

!

Warning

Avoid your body being blown

directly by cold wind for long

period, otherwise your health

may be affected.

Donít extend your fingers or

any other article into the inlet

or outlet during operation of

the machine for touching re-

volving fans may cause human

injury or damage of machine.

If something abnormal (e.g.: burnt

smell etc.) occurs, stop running the

machine, shut down the manual

power switch and contact after

service. Continuous operation in

disorder may cause fire hazard or

electric shock etc.

!

When you have to disassemble

and reinstall the machine, entrust

it to after service. Improper inst-

allation may cause fire hazard,

electric shock or damage of ma-

chine.

!

Unauthorized alteration or repair

work is strictly forbidden. Impr-

oper alteration or maintenance

may cause fire hazard, electric

shock or water leakage. Repair

work should be entrusted to cert-

ified person of after service.

!

Attention

Ensure the drainage hose work

normally during installation.

Improper installation of drainage

can cause water leakage and

damp articles.

!

DO NOT install the machine in

place where flammable gas

releases easily to avoid fire

hazard.

Ensure electric leakage breaker

being installed. Electric leakage

breaker MUST be installed,

otherwise electric shock may be

caused.

!

If the power supply cord is

damaged, call a certified

electrician of the manufacturer

or other maintenance department

to replace it.

1 0

Important Points of Safety

!

Attention

* Ensure ventilation of the room

if the machine is used with

burning facilities. Deficient

ventilation can cause oxygen

shortage.

* DONíT lay any burning facilities

in place where winds produced by

the machine can reach. Incomplete

combustion of burning facility may

be caused otherwise.

* Check whether installation

bench of the machine is

damaged after a long period

of use. Machine on damaged

bench may fall down and cause

human injury or other damage.

* DONíT clean the machine with

water. Electric shock may occur

otherwise.

* In place where winds produced

by the machine can reach, donít

lay any animals or plants which

may be hurt otherwise.

* DONíT put flammable spray

articles nearby or spray them to

the machine. Fire hazard may

occur otherwise.

* Donít put vases containing water

or other else on the unit assembly.

Otherwise, the machine may be

immersed internally and result in

bad electric insulation causing

electric shock.

* DONíT operate switch with wet

hand. Electric shock may occur

otherwise.

* The is machine CANNOT be

used for the purpose of prese-

rving food, animals, plants,

precision instruments and

artwork etc., which may be

destroyed otherwise.

* Stop operation and shut down

manual power switch before

cleaning and maintenance.

* The power supply MUST be of

rated voltage and connected with

special electrical supply circuit.

* DONíT replace fuse with ma-

terial other than fuse of proper

capacity. Replacing fuse with

metal wire or copper etc. can

cause fire hazard or other faults.

11

Operating Instructions

Recommendations

Use COOL in summer.

Use HEAT in winter.

Use DRY in spring,autumn and in damp climate.

AUTO RUN, COOL,HEAT and DRY operation

AUTO

SET

AM

*

MODE FAN SWING

2

TEMP

CLOCK

3

TIMER

SET

SLEEP

FILTER RESET

RESET

ON/OFF

5

1

SWING

MODE

5

T E M P

ON

OFF

FAN

SLEEP

HEALTH FRESH

CLOCK

TIMER

SET

RESET

LIGHT LOCK

(1) Unit start

Press ON/OFF button, unit starts.

Previous operation status appears on display

(Not Timer setting). Power indicator lights up.

(2) Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Press FAN button. For each press, fan speed changes as follows:

Wire controller

LOW

Remote controller

MID HIGH

AUTO

AUTO

A

U

T

O

LOW

MID HIGH

AUTO

AUTO COOL DRY HEAT FAN

Unit will run in operation mode displayed on LCD.

Stop display at your desired mode.

(3) Select temp. setting

Press TEMP button

Every time the button is pressed, temp. setting increases 1 C.

If button is kept depressed, temp.setting will increase quickly.

Every time the button is pressed, temp. setting decreases 1 C.

If button is kept depressed, temp. setting will decrease quickly.

Unit will start running to reach the temp. setting on LCD.

(4) Fan speed selection

Unit runs at the speed displayed on LCD.In HEAT mode, warm air will blow out after a short period of time due to cold-draft prevention function.

In DRY mode, when room temp. becomes 2 C higher than temp. setting, unit will run intermittently at

LOW speed regardless of FAN setting.

(5) Unit stop

Press ON/OFF button.

Only time and room temp remains on LCD.

All indicators go out.

Vertical flap closes automatically.

Hints

Wire controller can memorize each operation status.

When starting it next time, just press ON/OFF button and unit will run in previous status.

Auto running: During the Auto running mode, air conditioning running and can auto-select the cooling, heating, fan mode according to the room temperature.

Fan running: The AC only have air supply running no cooling and heating running at the condition, AC can't have auto air supply running, and can't display the setting temperature value on the LCD.

During the heating running, after start the AC, in order to prevent cooled air, AC can stop for a while before send heat air.

During the dehumification running, when the room temp. setting temp. , not setting condition according to the air speed.

1 2

Operating Instructions

TIMER Operation

MODE FAN SWING

TEMP HEALTH

SET

ON

AM

SET

AM

*

CLOCK

2

TIMER SLEEP

4

FILTER RESET

3

RESET

SWING

MODE

T E M P

ON

OFF

FAN

1

SLEEP

HEALTH FRESH

ON/OFF

1

SET CLOCK

2

TIMER

4

3

LIGHT

LOCK

RESET

Set Clock correctly before starting Timer operation.

You can let unit start or stop automatically at following time: Before you wake up in the morning, or get back from outside or after you

fall asleep at night.

TIMER ON/OFF

(1)After unit start, select your desired operation mode.

Operation mode will be displayed on LCD.

Power indicator lights up.

(2)TIMER mode selection

Press TIMER button to change TIMER mode.

Every time the button is pressed, display changes as follows:

ON OFF

ON

OFF blank

Select your desired TIMER mode (ON or OFF)

To cancel TIMER mode

(3)Timer setting

Press TIME button.

Every time the button is pressed, time increases 10min.

If button is kept depressed, time will change quickly.

Every time the button is pressed, time decreases 10min.

If button is kept depressed, time will change quickly.

Time will be shown on LCD. It can be adjusted within

24hours.

(4)Confirming your setting

After setting correct time, press SET button to confirm

"ON" or "OFF" stops flashing.

Time displayed: Unit starts or stops at x hour x min (ON or OFF).

Timer mode indicator lights up.

Just press TIMER button several times until TIMER mode disappears.

According to the seting timing open, close sequence, can realize first open then colse the unit or first close then open the unit.

Hints:

Wire controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if timer setting is the same as previous one.

Wire remote controller or remote controller can memorize each working condition. Next time open the unit, only need to press the ON/OFF key, the AC can work according to last time working condition.(Timing, Sleeping and Swing mode not included.)

From Timing close to timing open, can setting sleep mode.

Please close health function first before setting Timer, then you can do the TIMER ON operation.Please do not use the health function when in TIMER ON state.

1 3

Operating Instructions

TIMER Operation

MODE FAN SWING

SET

ON

PM

OFF

AM

*

CLOCK

2

TIMER

TEMP

HEALTH

3

SET

SLEEP

6

4

FILTER RESET 5

RESET

ON/OFF

1

SWING

MODE

T E M P

ON

OFF

1

FAN

SLEEP

2

HEALTH FRESH

3

CLOCK SET

TIMER

6

RESET

4

5

LIGHT LOCK

TIMER ON-OFF

(1)After unit start, select your desired operation mode

Operation mode will be displayed on LCD.

Power indicator lights up.

(2) Press TIMER button to change TIMER mode

Every time the button is pressed, display changes as follows:

ON OFF

ON

OFF blank

(4) Time confirming for TIMER ON

After time setting, press TIMER button to confirm.

"ON" stops blinking, While "OFF" starts blinking.

Time displayed: Unit starts at Xhour X min.

(3)Time setting for TIMER ON

Press TIME button.

Every time the button is pressed, time increases 10min.

If button is kept depressed, time will change quickly.

Every time the button is pressed, time decreases 10min.

If button is kept depressed, time will change quickly.

Time will be shown on LCD.

It can be adjusted within 24hours.

AM refers to morning and PM to afternoon.

(5)Time setting for TIMER OFF

Follow the same procedures in "Time setting for

TIMER ON".

(6)Time confirming for TIMER OFF

After time setting, press SET button to confirm

"OFF" stops flashing.

Time displayed: Unit stops at X hour X min.

To cancel TIMER mode

Just press TIMER button several times until TIMER mode disappears.

According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.

1 4

Operating Instructions

Note: Before using this function, must adjust the clock, or the sleep function will be disordered.

Comfortable Sleep

At night, before going to bed you can press down the SLEEP button on the controller and the airconditioner will run by the comfortable sleeping mode to make you sleep more comfortable.

SET

AM

OFF

AM

*

MODE FAN

SWING

TEMP HEALTH

CLOCK

TIMER

SET

SLEEP

FILTER RESET

RESET

ON/OFF

Sleep Function

SWING

MODE

T E M P

ON

OFF

FAN

SLEEP

HEALTH FRESH

SET CLOCK

TIMER

RESET

LIGHT LOCK

In cooling, dehumidifying mode

hour the temp. rises 1 and then run continuously for another 6hrs' and then close. The actual temp.

is higher than the setting one which is to prevent from being too cool to your sleep.

In heating mode

close after 3hrs' continuous operation. The actral temperature is lower than the setting one which is to prevent from being too hot to your sleep.

Note:

In AUTO mode, unit will run in SLEEP function according to the operation mode.

After setting SLEEP function, it is forbidden to calibrate clock.

If the set sleep-time does not reach 8 hours, the unit will stop operation automatically after set time is complete.

Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set TIMER-

ON function first, the sleep function can only be set before TIMER-ON; if set theSLEEP function first, the TIMER function can not be set.

After setting sleep function, not allowed to adjust the clock. Can't use the remote controller operate the AC. If so, please cancel the sleep function first.

After setting sleep function, can't set the timing function.

SETTING T

1 hr

1 hr decrease 2

C decreases 2 C about 3 hrs

3 hrs

SHUT DOWN increase1

C

SLEEP RUN BEGINS

Heat mode

SLEEP RUN STOPS

SLEEP RUN BEGINS about 6 hrs

SLEEP RUN STOPS

1 hr

1 hr increase 1 increase 1

C

C

SETTING T

SHUT DOWN

Cooling mode

1 5

Operating Instructions

SET

AM

OFF

AM

*

MODE FAN SWING

TEMP HEALTH

CLOCK

TIMER

SET

SLEEP

FILTER RESET

RESET

ON/OFF

SWING

MODE

T E M P

ON

OFF

FAN

SLEEP

HEALTH FRESH

CLOCK

TIMER

SET

RESET

LIGHT LOCK

Health Function

1.How to use the health function (only for units

with this function)

After set the right function mode, press health button,

remote controller or wire controller displays ì î,

oxygen pump or negative ion generator starts up to apply

oxygen or negative ion to indoor unit. Press the button

again,the sign ì î disappeared and negative ion generator

stops working. After all health function of the indoor unit

being fully canceled, oxygen pump stopped.

CAUTION: oxygen pump is automatically stopped, if press health button just then, oxygen pump could not start up. But if the air

On the "Health" mode, if you want to setting timing open mode, should close the health first: On the timing open mode, please don't use health function.

conditioner has the negative ion function simultaneous, when press the health button, negative ion function could still be operated. When the temperature of the outdoor unit to oxygen-make function.

Power Failure Compensation (to be applied for a necessary situation) :

After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working, it will resume the previous working state when the power is supplied again.

Setting Method:

When the remote controller is on (excluding timer mode and fan mode), press the "Sleeping" button on the remote controller 10 times within 5 seconds, and after the buzzer rings 4 times, the air conditioner will enter the state of power failure compensation.

Cancel Method:

Press the "Sleeping" button on the remote controller 10 times within 5 seconds, and after the buzzer rings 2 timer, the power failure compensation mode will be cancelled.

Notes:

When a power failure suddenly occurs during the air conditioner is working after the power failure compensation is set, if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the "Switch On/Off" button after the power comes again.If the controller no sleep key ,use the "swing" key instead the "sleeping" on setting the auto restart function.

Concerning MRV Auto Restart function for H-MRV models

Haier Auto Restart function when the unit power drops down suddenly, the unit microprocessor will store the previous working condition and when the power is on again, the unit will run as this memory.

Auto Restart function is designed basically on the MRV whole system, but it is suitable for each indoor unit individually.

If some of indoor units power cut down, but the outdoor unit and the other indoor units still work, maybe problems will happen such as freezing at cooling mode and overload protection at heating mode on those indoor units without power.

Reason

When one or some indoor units power drops down and the other indoor units are still work, the indoor units without the power, will keep the previous working condition before the power is off. And expansion valve keeps open at a kind of opening rate condition as the previous requirement, so there is refrigerant flowing in the exchanger, but the indoor fan stops working. If the units work at cooling mode, the indoor units without the power will maybe make freezing. If the unit works at heating mode, maybe the outdoor unit compressor will stop because of the pressure or temperature protection. This is our design basically on Auto Restart function currently.

Haier, Herewith, solemnly informs our customers, installers, distributors, etc.

when making installation, please make sure when the power is shut down whether artificially or accidentally, the whole system including outdoor unit and all the indoor units must be off. If you do not make the installation as our indication, Haier will not be responsible for any problem resulting from this.

User Caution

About the remote cnotrol operation, above only take wired remote controller and remote controller (1) as a example about the remote controller (2) and remote receiver use method, it is the same remote controller (1) , please use refer to above method.

No sleep function when use remote (2) and remote receiver.

1 6

Trouble Shooting

The following cases are not troubles.

Water flow sound is heard.

"Hua-Hua

"

A sound of "Pi-Pa " is generated.

Smells are given off.

During operation , mist or steam are blown out.

During operation

,

the air conditioner may sometimes exhibit a sound of "clatter

"

or

"rumble

"

. This is the common sound of refrigerant flow but not a trouble.

This is caused by the thermal expansion or cold shrinkage of plastics.

Sometimes there are smells in the air flow from the indoor unit. This is caused by the smell of cigarettes or paint coatings inside the unit.

During COOL or DRY operation, the unit may blow out a thin mist. This is the condensate water mist caused by sudden cooling of the indoor air blown out from the indoor unit.

During COOL operation changes to FAN mode.

, it automatically

The system couldnt be re-started immediately

after turning off.The unit can

' t start?

In order to prevent frost accumulation on the heat exchanger in the indoor unit

, sometimes it will automatically transfers to FAN mode, but soon will return to

COOL mode.

This is due to the systems self-protection function , which prevents it from restarting in 3 min after stops.

Please wait for 3 min.

1 8

Trouble Shooting

During DRY operation, there is no air sent out or fan speed cant be changed.

In HEAT mode , the outdoor unit generates water or steam.

This occurs during removal of the frost

(in defrosting operation) on the radiator of outdoor unit.

In HEAT mode , the indoor fan still keeps running even the unit operation stops.

Defrost operation

After the unit stops , the indoor fan will continue to run for a while to eliminate

residual heat.

Before asking for after-service to an authorized service center, please check your air conditioner for the following items

The system couldnt start

Is power on/off switched on?

Is the power supply line normal?

Power failure?

ON

OFF

Is current leakage breaker triggered?

The power on/off switch is not at position of "ON

"

.

Please do immediately cut off power supply and contact the authorized service center.

1 8

When Fault Occurs

Poor cooling or heating

Is the operation controller adjusted as required?

Are there any obstructs before the air inlet or outlet?

Is there any door or window left open?

Is there any other heat source in the room?

Poor cooling

Is there any direct sunlight into the room?

Are there too many people in the room?

If , after the above checks and the corresponding corrective actions , the system remains abnormal operation , or the following facts appear, please turn off the air conditioner and then contact the local authorized service center.

Frequent open of fuse or breaker.

There is water leakage during COOL or DRY operation.

The operation is abnormal or abnormal sound is heard.

1 9

Notice to Users

Notice to users

To ensure proper operation of the system

, the user shall follow this instruction manual to install the unit.

When handling the air conditioner

, please be care not to scratch the case surface.

This instruction manual describes the installation method aided with the installation tools specified by manufacturer .

The maximum length of connection pipe is 50 m , and the maximum difference between levels of indoor unit and outdoor unit shall be 30 m.

Please keep the installation instruction manual well for reference in maintenance or changing installation position.

After installed

,

please follow the operational instruction manual to use the air conditioner properly.

Information about application

Adjust your desired air flow direction Avoid direct sunlight and gas flow

Keep appropriate room temperature

Too cool or too warm wont benefit to your health , but causes an increased energy consumption.

Effectively use the timer Using

TIMER mode you can enjoy a comfortable room temperature when wake up or come back home.

Maximum temperature

Caution: After installation

,

please confirm no refrigerant leaks.

2 0

Installation Precautions

Before installing, do read this "Safety precautions" carefully to guarantee the proper installation.

wrong installation occur, it is very possible death and severe injury and other serious accidents will happen. For those items are listed in" Warning"

!

Note" part can also cause serious accidents. Above all, both the two parts are very important contents related to safety, so they must be obeyed.

After finishing the installation work, do test run to verify everything is normal. After that please explain the using and maintenance methods to the user. Additionally, give this installation manual and operation manual to the user and ask them to keep it properly.

!

Warning

The distributing shop, where you bought the air conditioner, or the specified shops shall do the installation work. If you do the installation work by yourself, the improper installation will cause

water leakage, electric shock fire and other accidents.

The installation work shall be in line with what the installation manual specified. If installation is not proper, water leakage, electric shock, fire and other accidents will occur.

Install the air conditioner to a place where can definitely stand its weight. Places not firm enough will cause drop down of unit resulting in body hurt.

The installation work shall be preventive to typhoon and earthquake. If the installation work is not met with the requirements, overturn of the unit will occur resulting in accidents.

The wiring work shall be done by a qualified person and referred to the " technical standard of electric equipment" , "indoor wiring regulation" and what the manual specified. Do use special circuit. If the capacity of the circuit is not enough or bad work, electric shock, fire and other

accidents will happen.

Using the specified cable to do wiring work and connecting firmly and properly. Fix the connecting part of the terminals to prevent it from the external force.Improper connection and fixing will cause

heating and fire etc. accidents.

Wiring shall be kept in correct shape avoiding extrusion. After installation, the electric box cover and the external panel shall not nip the wire. Improper installation will cause heating and fire etc.

accidents.

When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant (R22). If air and other things enter, abnormal high pressure will occur, which easily cause break and body injuries etc. Accidents.

When installing, do use the accessories or specified parts. If not using the parts specified by our company, water leakage, electric shock, fire and refrigerant leakage will occur.

Do not lead the drainpipe to drain where the sulfur gas may be involved. Otherwise, the poisonous gas will enter into the indoor.

During installation, if refrigerant leakage occurs, do the ventilation work immediately. As soon as the refrigerant gas meets fire, poisonous gas will be produce. If the refrigerant gas enters into room and meet the air blowing heater, heater or stove etc. fire source, the poisonous gas may be produced.

After installation, confirm there is no leakage of refrigerant.

Do not install the unit in a place where the combustible gas may be leaked. In any case the combustible gas leaks and accumulated around the unit, fire accident will occur.

Do heat insulation work to the refrigerant gas pipes and liquid pipes to reach the purpose of heat preservation. If the heat insulation measure is not sufficient, water generated by condensing dew will drip leading to wet the floor and indoor articles.

!

Note

Do grounding work.Do not connect the grounding wire to gas pipe,tap,lighting rod or telephone line.Improper grounding will cause electric shock.

After electric installation,power on them to do electric leakage test.

2 1

Installation Precautions

! Attention

This description does not address to all possible cases. For new requirement and query, please consult the regional sales center of Haier Air Conditioner General Co., Ltd.

! Warning

This instruction manual must be read carefully before beginning of installation, improper installation may cause accidents and thus bring about machine damage and personal casualty.

Installing tools

1. Screw driver 6. Pipe cutter 10. Leakage detector or soap water

2. Hacksaw 7. Pipe expander 11. Measuring tape

3. Driller of 70mm diameter 8. Knife 12. Scraper

4. Spanner (diameter 17, 27mm) 9. Pinchers 13. Refrigeration oil

5. Spanner (14, 17, 19, 27mm)

Electrical requirements

The power supply shall be connected from the outdoor side. (For models with electric-aided heating function, the power supply to the indoor unit shall be connected at the indoor side

The power cord size is 3 G(1.0-1.5)mm

2

, type of H05RN-F).

A separate power circuit shall be supplied and connected by a qualified electrician according to the wiring rules specified in the corresponding national standard.

A current leakage breaker must be installed.

The connection method of power cord is " Y " type. If the power flexible cord is damaged, it shall be replaced by the manufacturer or its service department or similar qualified technician so as to avoid risks.

Power cord plug: L should be connected to the live wire, N should be connected to the neutral wire and to the ground wire.

Connection wire size: 3 G (1.0-1.5) mm

2

, type of H05RN-F.

Signal transmission wire size:H05RN-F 2 x (0.75-1.5) mm

2

(shielded wire).

Power cord, connection wire and signal wire shall be provided by the user.

Indoor unit

1. Select suitable places the outlet air can be sent to the

entire room, and convenient to lay out the connection

pipe, connection wire and the drainage pipe to outdoor.

2. The ceiling structure must be strong enough to support

the unit weight.

3. The connecting pipe, drain pipe and connection wire

shall be able to go though the building wall to connect

between the indoor and outdoor units.

Fig 1

4. The connecting pipe between the indoor and outdoor

units as well as the drain pipe shall be as short as possible. (See Figure 1)

5. If its necessary to adjust the filling amount of the refrigerant, please refer to the installation

manual attached with the outdoor unit.

6. The connecting flange should be provided by the user himself.

7. The indoor unit have 2 drainage outlet, one outlet be jamedwith rubber cap, during installation

only use another outlet (In/Out liquid pipe side). When necessary, use the two outlet at the

same time.

8. Not place the TV., equipment, facility, piano etc, expensive goods below the AC, prevent the

water dropping down from the AC and lead to damage to the goods.

22

Installation Procedure

After selecting the unit installation location, proceed the following steps:

1. Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall-through tube

purchased locally. The wall hole shall be with a outward down slope of at least 1/100. (See

Figure 2)

2. Before drilling check that there is no pipe or reinforcing bar just behind the drilling position.

Drilling shall avoid at positions with electric wire or pipe.

3. Mount the unit on a strong and horizontal building roof. If the base is not firm, it will cause

noise, vibration or leakage (see Figure 6).

4. Support the unit firmly.

5. Change the form of the connection pipe, connection wire and drain pipe so that they can go

through the wall hole easily.

Figure showing installation dimensions: (unit:mm)

Model a

AE092FCAKA 615

AE122FCAKA

AE142FCAKA

AE182FCAKA

AE212FCAKA

770

990 b

648

804

1024 c

452

452

452 d

225

225

225 e

55

55

55 f

125

125

125 g

225

225 i

100

100

225 100 c b

i e f d g a

Fig 2

223

223

500

1249

AE072FCAKA

AE242FCAKA

Notes

1.For electrical heating unit, the air outlet not allowed directly connecting with canvas

etc. easy catching fire goods.

2.This series' indoor unit are all middle static pressure(30 Pa external static pressure ).

3.An access port must be provided during installation of indoor unit for maintenance.

23

Installation Procedure

Installation of indoor unit

When installing the ceiling concealed type indoor unit, a specially designed return air bellows shall be installed, as shown in Figure 3, Figure 4.

Figure 3

Installing building roof

*0.5m or*5m

A

Ceiling

Air supply

Unit

Air outlet duct

Detail A

Figure 4

Air outlet grille

Return air

Return air bellows

Return air bellows

Air supply

No obstacles within 1 m

Unit

Return air

Each air return and supply duct should fix to the floor precast slab by using an iron stand. Use glue to seal the interface closely. Recommend the distance between the air return duct and the wall is more than

150mm.

The distance between air duct outlet and air conditioner outlet is according to the length of actually installed air duct and in service behavior of the static pressure terminal: Installation sketch map for long and short air duct is showed below, when connect to short air duct, using low static terminal (terminal color is write), the distance between air duct outlet and air conditioner outlet is no more than 0.5m; when connect to long air duct, using middle static terminal (terminal color is red), the distance between air duct outlet and air conditioner outlet could be within 5m at this point.

Figure 5

joint of air diffuser sling dog drain piping air return duct air return shutter

transition

air duct air outlet duct air diffuser

Drain piping of condensed water should keep a downhill grade of 1% or more. Use insulating pipe to cover the drain piping of condensed water to keep warmth.

As figure shown, suspend and install the unit.

M8 broad foundation bolt

Figure 6

M8 suspension screw

M8 broad lock ring

M8 nut

Unit

24

Figure 5

Installation Procedure

Installation of indoor unit

Installation for air duct of indoor unit

1

. Installation for air supply duct

This type of unit uses circular air duct with its caliber of 180mm.

An additional transitive air duct is necessary for the circular air duct to connect to the air

supply inlet. It should be also connected to its respective air diffuser separately. See

Fig.1. Adjust the wind speed of each air diffuser outlet to keep in line on the whole, so

as to meet a demand of the air conditioner in the room.

Indoor unit

flexible joint or static pressure box

transitive air duct circular air duct joint of air diffuser

air diffuser

Fig1: Duct connected

2

. Installation for air return duct

Use rivets to connect the air return duct to the air return inlet of the indoor unit. The

other end connects to the air return shutter. as shown in Fig.2.

air return shutter air return duct indoor unit rivet

Fig2: Duct return connected

3

. Air duct insulation

Insulation layer is needed for air supply and return duct. First, paste a glue nail to the

air duct, and then attach the insulation cotton that has a tinfoil layer and use the glue

nail cover to fix. Finally, seal the air duct interface with tinfoil adhesive tape closely.

as shown in Fig3.

galvanized board insulating fabric

tinfoil glue nail glue nail cover adhesive tape

Fig3

25

Installation Procedure

Installation of indoor unit

Installing the suspension screw:

Use M8 or M10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, M10 size is the only choice). These screws shall be installed as follows with space adapting to air conditioner overall dimensions according to the original building structures.

Wooden structure

A square wood shall be supported by the beams and then set the suspension screws.

Square wood

Suspension screw

New concrete slab

To set with embedded parts, foundation bolts etc.

Beam

Guide plate embedded part

Iron reinforcement

Foundation bolt

Pipe suspension foundation bolt Knife embedded part

Original concrete slab

Use hole hinge, hole plunger or hole bolt.

Steel reinforcement structure

Use steel angle or new support steel angle directly.

Hanging bolt

Suspension screw

Support steel angle

Hanging of the indoor unit l

Fasten the nut on the suspension screw and then hang the suspension screw in the T

slot of the suspension part of the unit.

l

Aided with a level meter, adjust level of the unit within 5 mm.

26

Installation Procedure

1. Remove upper cover of wire controller

Remove upper part of wire controller by press.

PCB is mounted on lower part of wire controller, be careful not to damage it.

Installation of remote controller

Upper cover of wire controller

2. Install the wired remote controller

Please drill two holes on the wall according to the back cover screw hole position of the wire remote

controller, then strike the wood block to the holes respectively, then align the 2 screw hole of the wire controller back cover to the wood block, fasten the wire reote controller to the wall use wood screws.

3. Switch setting

The switchs setting as follows:1.ON 2.OFF 3.ON 4.OFF

Note

Try as far as possible a flat surface for installation.

Don't use excessive force when tightening screws, or lower part might got deformed.

4. Connecting method as the following chart

No Symbol

1 A

2 B colour

White or Green

Red

3 C

Yellow

4 D contents

12V

Gnd

COM

Switch button

Lower cover of wire controller

Screw hole

Back cover of the wire controller

Use shielede wires for telecommunication between wire controller and indoor unit; indoor unit and outdoor unit. Ground the shield on one side.

Otherwise misoperation because of noise may occur.

Signal wire is self-provided by user.

ground

Shielded wire

5. Replace the upper cover of wire controller

Be careful not to hold down the wiring.

Hint

1. Power supply switch and signal wire should be prepaired by the user.

2. Don't touch PCB with hand.

27

Installation Procedure

Installating the Reciever and MP3 equipment MP3

Installation of receive display

Because of the temperature sensitive device, do not install the receive display at straight sunlight place, either in front of air outlet grill, for it is effected greatly from cool air and heat air, the receive display is at least 20mm distance to the air outlet grill.

Since there is light sensitive device which receives wireless remote signal, so do not installed behind the window curtain or other obstacles, in order not to obstruct the signal.

Must fix the remote control wire far from strong electricity (such as the wiring of electric light, air conditioner, etc.) and weak electricity (such as the wiring of telephone, interphone, etc.).

1.Fix the receive display with screws on the selected place

2.Place the panel onto the fixed frame, pay attention that the four claws must be placed into the corresponding four poles on the frame

Connecting wiring method of receiver :

Refer the indoor unit wiring diagram .

safety cautions see the electrical wiring part .

28

Installation Procedure

Drain pipe

! Caution

In order to drain water normally, the drain pipe shall be processed as specified in

the installation manual and shall be thermal insulated to avoid dew generation.

Improper hose connection may cause indoor water leakage.

Requirements

The indoor drain pipe shall be thermal insulated.

The connection part between the drain pipe and the indoor unit shall be insulated so as to prevent dew generation.

The drain pipe shall be slant downwards (greater than 1/100). The middle part shall not be of S type elbow, otherwise abnormal sound will be produced.

The horizontal length of the drain pipe shall be less than 20 m. In case of long pipe, supports shall be provided every 1.5 ñ 2m to prevent wavy form.

Central piping shall be laid out according to the following figure.

Take care not to apply external force onto the drain pipe connection part.

1.5m~2m

Support

Insulation

(supplied by the user)

Down slope above 1/100

S type elbow

To the largest (app. 10cm)

Wall

VP30

Down slope above 1/100

Pipe and insulation material

Outside

Slant

Drain pipe (supplied by the user)

Pipe

Rigid PVC pipe VP31.5mm (internal diameter)

Insulation

Foamed PE with thickness above 7mm

Hose

Drain pipe size: ÿ19.05mm

2

(3/4") PVC pipe

The hose is used for adjusting the off-center and angle of the rigid PVC pipe.

Directly stretch the hose to install without making any deformation.

The soft end of the hose must be fastened with a hose clamp.

Please apply the hose on horizontal part

Hose

sulation treatment:

Hose clamp

Wrap the hose and its clamp until to the

indoor unit without any clearance with

insulating material, as shown in the figure.

Drain confirmation

Subsidiary insulation

Insulation

Rigid PVC pipe

During trial run, check that there is no leakage at the pipe connection part during water draining even in winter.

29

Installation Procedure

R

efrigerant piping

Allowable pipe length and drop

These parameters differ according to the outdoor unit. See the instruction manual attached with the outdoor unit for details.

Pipe material and size

Pipe material

Model

Pipe size

(mm)

Phosphorus deoxidized copper seamless pipe (TP

2

M) for air conditioner

AE072FCAKA

AE092FCAKA

AE122FCAKA

AE142FCAKA

AE182FCAKA

AE212FCAKA

AE242FCAKA

Gas side

ÿ9.52

ÿ12.70

ÿ15.88

Liquid side

ÿ6.35

ÿ6.35

ÿ9.52

Supplementary refrigerant

The refrigerant supplementation shall be as specified in the installation instructions

attached with the outdoor unit. The added refrigerant shall be R22.

The adding procedure shall be aided with a measuring meter for a specified amount of supplemented refrigerant

A

Requirement

Overfilling or underfilling of refrigerant will cause compressor fault. The amount of the added refrigerant shall be as specified in the instructions.

Pipe expander

Connection of refrigerant pipe

Conduct flared connection work to connect all refrigerant pipes.

Pipe cutting and expanding

If the pipe is too long or the flare is damaged, it needs to be cut or expanded.

Pipe expansion dimensions as follows:

Pipe diameter

ÿ

Size A (mm)

6.35 mm (1/4

"

) 0.8 ~ 1.5

9.52 mm (3/8

"

) 1.0 ~ 1.8

12.7 mm (1/2

"

) 1.2 ~ 2.0

15.88 mm (5/8

"

) 1.4 ~2.2

1. Pipe cutting 2. Removing burrs

3.Insertion nut 4. Pipe expansion

Correct

Incorrect

Slope Damage Bur Partial Overlong

The connection of indoor unit pipes must use double spanners.

The installing torque shall be as given in the following table.

Connecting pipe

O.D.(mm)

ÿ6.35

ÿ9.52

ÿ12.70

ÿ15.88

Installing torque

(N-m)

11.8 (1.2kgf-m)

24.5 (2.5kgf-m)

49.0 (5.0 kgf-m)

78.4 (8.0 kgf-m)

Increased installing torque (N-m)

13.7 (1.4 kgf-m)

29.4 (3.0 kgf-m)

53.9 (5.5 kgf-m)

98.0 (10.0 kgf-m)

30

Double-spanner operation

Installation Procedure

R

efrigerant piping

Vacuum pumping

With a vacuum pump, create vacuum from the stop valve of the outdoor unit.

l

Emptying with refrigerant sealed in the outdoor unit is absolutely forbidden.

Open all valves

Open all the valves on the outdoor unit.

Gas leakage detection

Check with a leakage detector or soap water that if there is gas leakage at the pipe connections and bonnets.

Insulation treatment

Conduct insulation treatment on both the gas side and liquid side of pipes respectively.

During cooling operation, both the liquid and gas sides are cold and thus shall be insulated

so as to avoid dew generation.

l

The insulating material at gas side shall be resistant to a temperature above 120

*

.

l

The indoor unit pipe connection part shall be insulated.

The notch upward (Attached detail view)

Indoor unit

Field piping side

Subsidiary insulation tube

31

Installation Procedure

Electric wiring

! Warning

!

The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire.

During wiring connection, the power cord shall be of the specified cable and reliably fastened so that external forces applied to the cable wouldnt transfer to the terminals. Improper connection or fastening will cause danger of heating, fire etc.The power cord must be fitted with a grounding wire.

Grounding shall be made as specified. Unreliable grounding will cause electric shock. The grounding wire shall not be connected to the gas pipeline, water pipeline, thunder arrestor and telephone wire

! Caution

!

A current leakage breaker shall be installed, otherwise it electric shock would happen easily.

If the power cord is damaged, it must be replaced by the manufacturer or its service center or similar personnel to avoid risks. The power supply to the indoor unit shall be laid in complying with the operational instruction manual.

The electric wiring shall avoid contacting with the high temperature part of the piping so as to prevent the cable insulation melts and cause dangers.

After connected on the terminal block, the wires shall be bent to U form and then fastened with wire clip.

The control wiring and refrigerant piping may be laid and fastened together.

Before completion of vacuum pumping of the refrigerant pipe system, do not electrify the indoor unit.

The power cord of the indoor unit and connection wiring between indoor and outdoor units shall be laid out according to the operational instruction manual of the indoor unit.

The connection of the power cord shall comply with the local regulations.

The power supply wiring connection should meet the local regulation.

Wiring connection method : (the wiring diagram is attached inside the machine)

1) Ring terminal connection method

If there is a ring at the end of the connection wire, the wire connection method is as shown in the right figure. Remove the terminal screw and insert it through the ring at the connection wire end, then connect to the terminal board and fasten the screw.

2) Straight terminal connection method

Connection method for ring terminal

If there isnt a ring at the end of the connection wire, the connection method shall be: loosen the terminal screw, insert the connection wire end completely into the terminal board and fasten the screw.

Pull the connection wire outwards slightly to confirm it is clamped tightly.

3) Clamping method of the connection wire

After wire connection is finished, the connection wire must be pressed tightly with wire clips, which shall apply to the outer sheath of the connection wire.

32

Installation Procedure

Electric wiring

Wire connection for built-in indoor unit

Insert from outside the connection wire and signal transmission wire through the wall hole with pipeline already arranged.

Pull out the front ends of connection wire and signal wire and make a circle on the signal wire.

Connect the connection wire according to the connection method and indoor and outdoor wiring diagram.

Pull the connecting conductor outwards slightly to confirm it is clamped tightly.

Connect the plug for connecting the signal wire with the plug of the signal wire connected from the indoor unit.

After wire connection is finished, install wire clips using the same method for connection wire clamping.

Note: When connecting the indoor unit and the outdoor unit, please do connect the wires with the same color terminals.

Notes:

Before connecting the conductors between indoor unit and outdoor unit, check for the number on the indoor and outdoor units connecting terminals. Connect the terminals with the same color and number with a wire.

Wrong connection would damage the controller of the air conditioner or the machine couldnt operate.

Do not connect the connection wire and signal wire with the same cable. They shall be connected respectively to ensure system normal operation.

Field setting

Field setting the unit number

In order to realize central control of the MRV air conditioning system, its necessary to set

the indoor unit number (control address).

Indoor unit number setting

Indoor unit number setting switch and confirmation of the settings.

There is a 4-position dial switch for setting the indoor unit number on the computer board of the indoor unit.

Setting way is as follows:

Before connecting the power supply, please set the indoor unit number manually according to the following table

Matrix of the dial switch and indoor unit number

Example:

1 0 0

Position 1 Position 2 Position 3 Representing unit number

0

1

0

1

0

1

0

0

1

1

0

0

0

0

0

0

1

1

1

2

3

4

5

6

Pos.1 Pos.

2

Pos.

3

Pos.

4

Setting for No. 2 indoor unit

Disabled

: 0

: 1

33

Malfunction

Indoor unit malfunction display code

Indoor unit malfunction

Float switch or water motor abnormal

Outdoor unit abnormal

Setting running mode is different with outdoor running mode

Liquid temperature sensor is abnormal

Gas temperature sensor is abnormal

The communication between indoor 846 chip and communication chip is abnormal

The communication with electronic expansion box is abnormal

The communication between the wire remote controller and indoor unit control board is abnormal

The communication between indoor and outdoor unit is abnormal

Water temp. sensor is abnormal

Display code

E0

E1

E2

E3

E4

E5

E7

E8

E9

EB

Outdoor unit malfunction display code

(When the wire remote controller display E1,can check the indoor unit control board

LED1 or the outdoor unit control board LED1 Outdoor unit control board LED

(ALARMA or ALARMB)).

Outdoor unit malfunction

Outdoor unit defrost temp. sensor is abnormal

Outdoor unit environment temp. sensor is abnormal

Outdoor unit suction temp. sensor is abnormal

Outdoor unit discharge temp. sensor is abnormal

Outdoor unit AC over-current protection

Outdoor unit DC voltage is insufficient protection

IPM protection

Outdoor unit EEPROM abnormal

Compressor Discharge temperature overheat protection

The communication between outdoor unit 857 and communication chip is abnormal

Outdoor unit system over-high pressure protection

LED flashing times flashing once flashing twice flashing 3 times flashing 4times flashing 6times flashing 7times flashing 9times flashing 10times flashing 11times flashing 12times flashing 13 times

34

Malfunction

Remote controller Timer and Operation indicator malfunction code

When the unit running, Timer indicator flash stand for indoor unit malfunction operation indicator flashing stand for outdoor unit malfunction

1. Indoor unit malfunction

Timer indicator

Flashing times

Indoor unit malfunction

Flashing once The liquid tube temperature sensor is abnormal

Flashing twice The gas tube temperature sensor is abnormal

Flashing 3 times The environment temperature sensor is abnormal

Flashing 4 times The communication with outdoor unit is abnormal

Flashing 5 times The ommunication with the electronic expansion valve control board is abnormal

6

The communication between indoor 846 and communication chip is abnormal

Flashing 8 times PMV strong electricity board is abnormal

Flashing 10 times Indoor unit PG fan motor is abnormal

Flashing 11 times Indoor unit water overflow or float switch is abnormal

Flashing 12 times Indoor unit EEPROM data is abnormal

Flashing 13 times Indoor unit is overload

Flashing 14 times The communication between indoor unit and wire remote controller is abnormal

2.Outdoor unit malfunction

Operation indicator flashing times

Flashing once

Flashing twice

Flashing 3 times

Flashing 4 times

Flashing 5 times

Flashing 6 times

Flashing 7 times

Flashing 9 times

Flashing 10 times

Flashing 11 times

Flashing 12 times

Flashing 13 times

Flashing 14 times

Flashing 15 times

Outdoor unit Trouble contents

Outdoor unit defrost temp. sensor is abnormal

Outdoor unit environment temp. sensor is abnormal ction temperature sensor is abnormal

Outdoor unit discharging temperature sensor is abnormal

Outdoor unit evapor ating temperature sensor is abnormal

Outdoor unit AC over-current protection

Outdoor unit DC voltage is insufficient protection

IPM protection

Outdoor unit EEPROM is abnormal

Compressor discharging temperature overheat protection

The communication between the 857&communication chip is abnormal

Outdoor unit high pressure protection

High pressure sensor PD is abnormal

Low pressure sensor PS is abnormal

35