- Home
- Domestic appliances
- Small kitchen appliances
- Coffee makers
- Grindmaster Cecilware
- 4K-GB-LD
- Operating instructions
advertisement
▼
Scroll to page 2
of 36
Operator Manual Powdered Beverage Dispenser GB Models 1, 2, 3, 4, 5, & 6 Model GB3M10-LD Model GB5M10-LD Model GB1HC Table of Contents Safety Information..................2 Installation...............................3 Operation ................................6 Cleaning...................................8 Maintenance .........................10 Troubleshooting Guide.........13 Parts Diagram and List..........15 Wiring Diagrams ...................23 Thank you for purchasing this quality powdered beverage dispenser. For your safety and the safety of others, read all warnings and the operator manual before installing or using the product. Properly instruct all operators. Keep training records. For future reference, record serial number here: Grindmaster-Cecilware 4003 Collins Lane, Louisville, KY 40245 USA Phone: 502.425.4776 Toll Free: 800.695.4500 Fax: 502.425.4664 Web: gmcw.com Email: [email protected] ©2016 Grindmaster-Cecilware Printed in USA Grindmaster-Cecilware provides the industry’s BEST warranty. Visit gmcw.com for warranty terms and conditions. 0516 Form # CW-314-01 Part # 390-00013 Safety Information Important Safety Information This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. For your safety and the safety of others, read all warnings and the operator manual before installing or using the product. DANGER: This term warns the user of imminent hazard that will result in serious injury or death. WARNING: This term refers to a potential hazard or unsafe practice, which could result in serious injury or death. CAUTION: This term refers to a potential hazard or unsafe practice, which could result in minor or moderate injury. NOTICE: This term refers to information that needs special attention or must be fully understood. WARNING The appliance is not intended for outdoor use. Do not clean with pressurized water or use in an area where pressurized water may be used. Cleaning and maintenance shall be made only by properly trained persons with supervision. CAUTION Lifting hazard. Single person lift could cause injury. Use assistance when moving or lifting. For safe and proper operation, the appliance has to be placed in a stable, vertical position. The appliance is not to be used by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. Be sure to provide supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must be supervised to ensure they do not play with the appliance. The appliance is only to be installed in locations where it can be overseen by trained personnel. NOTICE To avoid damaging unit, turn on power and wait for tank to fill with water before turning on heater. Observe machine voltage configuration. Do not apply improper voltage to machine or damage to machine will occur. Do not use extension cord. 2 Cecilware® GB Series Installation CAUTION: Lifting hazard. Single person lift could cause injury. Use assistance when moving or lifting. Water Inlet Connection: NOTICE: This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In addition: 1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for cleaning underneath. 2. An approved backflow prevention device, such as a double check valve to be installed between the machine and the water supply. Unpacking Instructions Carefully unpack the GB Machine and inspect immediately for shipping damage. Your GB Machine was shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the factory. In case of damage, contact the shipper, not GrindmasterCecilware. After the machine has been unpacked and placed on a counter, pull out the stainless steel drip tray. It should contain the following: • 1/4” Flare Water Inlet Fitting. The GB beverage dispenser is equipped with a 1/4" Flare Water Inlet fitting, which is located on the left side in the back of the base (when looking at the machine from the front). Water pipe connecting and fixtures directly connected to a potable water supply shall be sized, installed, and maintained in accordance with Federal, State, and Local codes. HIGHLY RECOMMENDED: A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/Phosphate Filter, to remove odors and inhibit lime and scale build up in the machine. Note: In areas with extremely hard water, a water softener must be installed in order to prevent mineral deposits that could result in malfunctioning of the equipment and in order not to void the warranty. GB Series Cecilware® 3 Installation (continued) Description and Location of Components Note: Refer to following illustration for description and location of COMPONENTS and CONTROLS. 14 lb. 14 lb. 14 lb. 14 lb. GRAM THROW, STRENTH ADJUSTMENT LAMP SOCKET 521 lb. 521 lb. 4 lb. 4 lb. LAMP 4 lb. 4 lb. CUP SIZE, VOLUME ADJUSTMENT LAMP STARTER HOT WATER SPOUT CAPP. SPOUT [2] CORD SET PRODUCT GUIDE SHELF WHIP CHAMBER DRIP TRAY GB2-LP DRIP TRAY 2K- GB DRIP TRAY GB2M-5.5 DRIP TRAY DRIP TRAY GB2-SKI FRONT VIEW GB3 SHOWN GB2-Super SKI RIGHT SIDE VIEW TANK ASS'Y HI-LIMIT (TEMP) LABEL AREA WATER LEVEL CONTROL DISPENSE VALVE HEATER ASS'Y AUGER MOTOR THERMOSTAT PRODUCT LABEL DRAIN HOSE W/PLUG DISPENSE BUTTON WATER INLET HOSE POWER SWITCH PILOT LIGHT FOR HEATER WHIPPER MOTOR BLOWER DUCT HOSE FAN/BLOWER POWER CORD SPOUT RINSE SWITCH DRIP TRAY RELAY/TIMER DRIP TRAY 4 WATER INLET VALVE Cecilware® GB Series Installation (continued) 1. HOPPERS: Depress the door latch on the left side of the door and pull door open to access the hoppers. • The hoppers hold up to 14 lbs. (14 kg) of Cappuccino product and up to 1.5 lbs. (0.7kg) of freeze dried coffee product, depending on model. • To remove the hoppers swing the top compartment door open and lift out the hoppers. • To reposition the hoppers in the compartment, slide the hopper base back between the rails until the 1/4" pin at the bottom of the hopper base falls into the 1/4" positioning hole of the compartment base cover. 2. RINSE SWITCH: With the door open, the rinse switch is located on the left side of the first Whipper chamber. • In the RINSE position, it disengages the hopper motors and allows only water to be dispensed. • It is used for flushing out the Whipper Chambers and to adjust the water dispense valves for proper flow rates. 3. HEATER SWITCH: This switch is located inside the cabinet behind the right hopper. Open door and remove right hopper to access it. • Its primary function is to shut off the heating element during the initial priming, start-up operation of the machine, or whenever the tank is being drained for service. Note: The Power Switch and Heater Switch must be ON in order for the elements to operate. 4. POWER SWITCH: This switch is located on the left side of the splash panel below the door. On 120V, 1.8 KW and 120/240 or 240V, 3 KW single element machines the power switch controls all power to the machine including the heater elements. Note: On 120/240V, 6 KW machines, the Power and Heater Switches are independent of each other. Both switches must be OFF in order for the machine to be completely shut down. 5. WATER LEVEL CONTROLS: Under normal conditions and operation, the water level in the tank should not drop more than 1/2" (1.3cm) from the probe. If it does, the tank is not refilling fast enough. Check the water line and water filter; they may need cleaning or replacing. GB Series 1. Tank Control Board (Export 240V 2. Water Inlet Valve (Export 240V 3. Water Level Sensor Part# 349-00012 Part# L706AL) Part# L462AL Part# L426AL) Part# K695QL Start-up Procedure NOTICE: Make sure that the Heater Switch, located behind right hopper with door opened, is in the OFF position. 1. Connect the 1/4" dia. copper waterline to the 1/4" flare water inlet fitting of the valve. 2. Plug the power cord(s) into a proper receptacle. Note: GB8M10 units use two power cords. Each cord must be plugged into a separate receptacle. 3. Activate the Power Switch (Toggle Up). The door display panel, the red power indicator light and the green dispense buttons will light up and the tank will start filling. Allow approximately 4-5 minutes for the tank to fill. 4. Activate the Heater Switch. Allow approximately 10-30 minutes for the water to reach a temperature of 190°F (88°C). The heat up time will depend on the water inlet temperature, the input voltage, and the wattage of the elements in the machine. 5. Place a 8 oz. (240ml) or larger cup under the left dispense nozzle, press and hold the left dispense switch for 6 seconds. The machine will dispense water at the rate of 1 oz. (30ml) per second. Repeat it several times to check for consistent output. Repeat same for the other dispense switches. This procedure checks that the dispense valves are not air-locked. 6. While the tank is heating, remove the hoppers, load them with products, and reposition them back in the machine. When the green ready light comes on, the tank has reached its brew temperature and the machine is ready to dispense the first cup of Cappuccino. Filling the Hoppers 1. To remove the hoppers, swing the top compartment door open and lift out the hoppers. 2. Fill each hopper with the correct product. 3. Reposition hoppers in the hopper compartment, making sure the hoppers are properly seated. If you need help, call Grindmaster-Cecilware Technical Service Department, (502) 425-4776 or (800) 695-4500 (USA & Canada only) 8 AM - 6 PM EST. Prior authorization must be obtained Grindmaster-Cecilware for all warranty claims. Cecilware® from 5 Operation Your new powdered beverage dispenser is easy to operate and maintain. Before you place it in service, please have all personnel familiarize themselves with these instructions. Keep this manual in a convenient place for ready reference. How to Operate To dispense a cup of Cappuccino or Coffee: • Place an 8 oz. (240ml) or larger cup under selected drink dispense nozzle. • For Manual units: Push and hold brew button until cup is 2/3 full, then release button. • For Automatic units: Press and Release button. Cup will fill up automatically to its preset amount. Adjustments Water Flow Rate Adjustment Adjust water flow rate to correct level in Whipping Chamber. The Dispense Valves are factory adjusted for a maximum Flow Rate of 1 to 1.3 oz./sec (30-38 ml/sec). [Approximate settings: 1.3 oz./sec (38 ml/sec) for COFFEE and CAPPUCCINO] Exceeding this Flow Rate will cause the Mixing Chamber to overflow. Note: To access the Water Dispense Valves, open door and remove Hoppers. TO ADJUST WATER FLOW RATE: 1. Open door and remove hoppers. Locate Dispense Valve behind hoppers, mounted on tank. 2. Locate adjustment screw on Dispense Valve. 3. Using Allen Key or flat screwdriver rotate, 1/4 turn at a time, CLOCKWISE to decrease water flow, or COUNTERCLOCKWISE to increase water flow. 4. Check water flow output, after each 1/4 turn. WATER FLOW ADJUSTMENT DISPENSE VALVE DISPENSE CAP Adjust Water Flow Rate so that the water level reaches half way up in the Mixing Chamber, as shown. TRIANGULAR RIB Temperature Adjustment (Tank Control Board Type) 1. Locate the Tank Control Board. 2. Press button under right side of display to increase temperature. 3. Press button under left side of display to decrease temperature. 4. Pressing both buttons simultaneously will reset to default 190°F (88°C). 190° Display Increase Decrease Temperature Adjustment (Thermostat Type) 1. Locate Thermostat: Remove the right side panel. Thermostat is mounted on side of tank. The GB beverage dispensers are factory set to deliver hot brewing water at 190°F (88°C) with the thermostat knob turned to full ON position. If adjustments should be necessary to increase or decrease the water TEMPERATURE, proceed as follows: Note: Set the Rinse Switch to ON. This will disengage the Hopper Motors when dispensing water for Temperature measurements. 2. To INCREASE the water temperature - With the Thermostat Knob to its maximum clockwise position, remove the knob and locate the slotted adjustment screw inside the hollow thermostat shaft. Using a narrow-bladed screwdriver, engage slotted adjustment screw and turn it ¼ turn slowly counter-clockwise. Allow a few minutes for the temperature to reach set level. The Heater Light will go ON, indicating the heating element is activated, wait for it to go OFF, indicating that the water has reached new set temperature. Take a temperature reading and repeat if necessary. 3. To DECREASE the water temperature - simply turn the Thermostat Knob one notch counter-clockwise to the next lower dial setting. CORRECT WATER LEVEL FOR MAX FLOW RATE. MIXING CHAMBER 6 Cecilware® GB Series Operation (continued) GB SKI SUPER - VOLUME AND PRODUCT STRENGTH ADJUSTMENTS DRINK STRENGTH ADJUSTMENTS - by adjusting the Auger Speed. I. UNITS WITH FIXED SPEED AUGER MOTORS-AC [CD150] - Fixed Auger Speed [95 RPM] and dispenses powder at a constant fixed rate. Drink Strength adjustments can be made by adjusting the water flow rate on the Water Dispense Valves. 1. Remove Hoppers to access the Dispense Valve, located behind the hoppers. 2. Locate Flow Adjustment Screw on Dispense Valve. 3. Rotate adjustment screw Counterclockwise to INCREASE Flow Rate, Clockwise to DECREASE Flow Rate. (Note: the water flow rate should not exceed 1 to 1.3 oz./sec.) Do not turn Adjustment Key more than 1/4 turn at a time without checking drink strength (ratio of water to powder). II. UNITS WITH VARIABLE SPEED AUGER MOTORS-DC [CD151] - Variable Auger Speed [10 to 130 RPM] Drink or Product Strength adjustments can be made by adjusting the Auger Motor RPM [knob on inside door panel], which controls the amount of product being dispensed [gram throw]. The gram throw is factory preset at 7. Because the consistency of each product varies, the customer can set the desired gram throw for each hopper. The water flow rate on the Dispense Valves should remain fixed. Note: the water flow rate should not exceed 1-1.3 oz./sec to avoid spillage from dispense chamber. DRINK SIZE ADJUSTMENTS a. Manual Machines : Hold down the Dispense Button until desired amount is dispensed. b. Automatic Machines with Timer L493A on Inside Door Panel NOT Programmable] & speed control board L556A: To increase the volume, turn the dial to the next increment. [0-1 is equivalent to 2 sec.] c. Automatic Machines with Programmable "Teach me"Timers [L576A or L582A]: These units do not have a cup size adjustment knob inside the door, since the timer is programmable from the dispense button. PROGRAMMING FOR AUTOMATIC DISPENSE WITH BUZZER 1. Turn Power Switch ON (toggle switch inside door). 2. PRESS and HOLD [red] STOP Button with one hand. 3. PRESS and HOLD [green] DISPENSE Button with other hand. 4. RELEASE [red] STOP Button ONLY. 5. Continue to HOLD [green] DISPENSE Button until buzzer sounds for (4 SEC. DELAY), then RELEASE. 6. PRESS and RELEASE [green] DISPENSE Button. Product begins dispensing. When it reaches the "DESIRED VOLUME", 7. PRESS and RELEASE [green] DISPENSE Button to SET "DESIRED VOLUME". DISPENSE Button can be "jogged" to top off. 8. PRESS and RELEASE [red] STOP button to LOCK IN "DESIRED VOLUME". Repeat steps 1 to 8 for each Dispense Button. PROGRAMMING INSTRUCTIONS FOR MANUAL DISPENSE WITH BUZZER 1. PRESS AND HOLD STOP [red] BUTTON WITH ONE HAND. 2. PRESS AND HOLD DISPENSE [green] BUTTON WITH OTHER HAND. 3. RELEASE STOP [red] BUTTON. 4. CONTINUE TO HOLD [green] BUTTON AFTER BUZZER SOUNDS (4 SEC. DELAY). 5. RELEASE DISPENSE [green] BUTTON. 6. PRESS AND RELEASE STOP [red] BUTTON. 7. YOU ARE READY FOR MANUAL DISPENSE. The Total Time The Water Is Running Is Accumulated And Saved Into Memory. For Normal Operation, Press and Release Dispense Button. The Timers Have Been Factory Preset for 6 oz. Cups for Coffee; For 8 oz. Cups for Soup and Cappuccino. To Change To Larger Or Smaller Cup Sizes [Volumes] Repeat Steps 1 To 8 Above. STO P HO WA T TER TO CHECK VOLUME AND GRAM THROW DISPENSED (ratio): 1. Remove the product guide from the hopper and position a receptacle under the hopper nozzle to catch the gram throw of product. Also place a measuring cup under extension tube to catch the water dispensed. 2. Push the dispense button and check the amount of product dispensed, amount of water dispensed, and time [use stop watch] to dispense that water. 3. The amount of of water dispensed in the measuring cup divided by the amount of time to dispense that water is the Water Flow Rate from Dispense Valve. FOR CAPPUCCINO: The machine is factory adjusted to dispense 4-4.5 gr./sec. per OZ. Cup. [32 grams Product per 8 oz. cup] The recommended throw is 28-32 grams per 8 oz. cup for Cappuccino, with 80% fill. FOR COFFEE: The machine is factory adjusted to dispense 0.3 gr./sec per OZ. Cup. [1.5 grams of coffee product per 5 oz. of liquid (in a 6 oz. cup). The recommended throw is 1.5 to 1.8 grams per 6 oz. cup of Coffee, with 80% fill. GB Series Cecilware® 7 Cleaning NOTICE: All sanitizing agents in the food zone must 2. Whipper chamber cleaning comply with 21 CFR 178.1010. Sanitize all food dispensing units periodically. All parts to be sanitized must be cleaned first. Cleaning and sanitizing frequency must follow state and local health department regulations. Daily maintenance: 1. Rinse whipper chambers • Position a container under dispense tubes. • Move rinse switch to "rinse". • Push and hold each dispense button 3 to 5 sec. • Move rinse switch to "serve". Note: On manual dispense machines, push and hold the dispense buttons for 10 seconds. 2. Empty drip tray, wash, rinse, and sanitize. 3. The outside of the machine can be cleaned with warm soapy water and a damp cloth. • Remove dispense caps by turning and lifting. • Remove mixing bowls by lifting and pulling. • Remove product tubes by pulling down. • Twist off whipping chambers clockwise. • Pull off whipper blades. • Twist off whipper chamber mounts clockwise. • Remove O-rings. • Remove tray by pulling levers down. • Remove both powder trays by pulling levers out. • Wash, rinse, and sanitize small parts and interior machine surfaces. • Reassemble all small parts. Note: When reassembling, align flat keyway inside blade with flat keyway of motor shaft. Push the whipper blade all the way on. Weekly maintenance: 1. Product hopper cleaning • Rotate product guides up, remove hoppers from machine. • Empty powder into pans. • Pull off product guides. • Remove agitator wheels. • Unscrew and remove front and back auger locks. • Remove auger. • Wash, rinse, sanitize, and air dry all small parts. • Wash & scrub hoppers and agitator wheel recesses with bristle brush. Rinse, sanitize, and allow to air dry. • Reassemble all hoppers. • Pour powder into hoppers. • Install all hoppers into unit. Sanitizing 1. Prepare a sanitizing solution in accordance with local health department regulations. You may also refer to the US Food and Drug Administration regulation 21 CFR 178.1010 “Sanitizing Solutions” and US Environmental Protection Agency 40 CFR 18.940 “Tolerance exemptions for active and inert ingredients for use in antimicrobial formulations (Food-contact surface sanitizing solutions)”. 2 Follow the instructions provided with the sanitizing agent. 3 Let all sanitized parts drain and air dry. DO NOT WIPE THEM DRY. 8 Cecilware® GB Series Cleaning (continued) AGITATOR GEAR AGITATOR WIRE AUGER MOTOR AUGER BUSHING FRONT NUT [2] FLANGE/ NUT AUGER AUGER BUSHING-BACK PRODUCT GUIDE DISPENSE CUP MIX BOWL SOCKET MIXING CHAMBER BASE MOUNT GROMMET SLINGER DISC WHIPPER CHAMBER TWIST TO REMOVE MOUNTING BASE 'O'-RING #125 EXTENSION TUBE GB Series WHIPPER BLADE Cecilware® 9 Maintenance Lit Display Replacement WARNING Risk of electrical shock. Turn off power to unit before replacing bulb or starter. To replace the picture inside metal door: Lift up the two end tabs on top of door with a pointed object or flat head screwdriver. Pull the entire picture frame out. Open up the two clear panels and replace picture. Tuck clear plastic panel inside bracket at top. Be sure to tuck clear panel under bracket before sliding frame assembly inside door. The longer metal tab side goes in the front. To replace the picture inside molded door: Remove molded door front by removing side screws. Slide out clear plastic panel with picture. Replace picture and slide the plastic panel w/ new picture into the door frame. Then put front molded door back on with screws on the sides. To replac PRODUCT LABEL PRODUCT LABEL 10 Cecilware® GB Series Maintenance (continued) Recommended preventive maintenance 1) Dispense Valves • Check all dispense valves for lime build-up. • Drain the water tank to just below the level of the dispense valves. • Remove the valves and clean. (Take these valves apart by hand as shown). • Replace the assembly as needed (L467AL -120V or L676AL - 230V import). • Replace the valve into the tank and refill tank. • Repair Kit M491QL. 2) • • • • • • 3) • • • • • Check all chamber mounts for signs of wear: Product running down the front of the unit. Product built up on the back of chamber mount. Remove chamber mount. Clean and re-lubricate motor shaft using food grade lubricant only. Replace with new chamber mount. Clean out vent motor, trough, and tubing. Lift up black tabs, remove trough drawer. Clean and replace trough drawer. Remove hose assembly from the motor. Clean out and replace hose. WATER FLOW ADJUSTMENT Dispense Valve Chamber Mount GB Series Cecilware® 11 Maintenance (continued) Component Tests Dual Probe Test If lack of water persists, check the probe as follows: 1. Turn on the power and water supply. 2. Check inside the tank to make sure the water is below the Probe. 3. Pull the BLUE wire and terminal OFF the Probe rod. If water still does not flow after the wire is disconnected from the Probe, the problem may be in the Tank Control Board. 4. If water starts flowing into the tank, the Probe may be grounded, due to excessive liming. Check with Ohm meter. Clean probe. Out of Product Sensor Test 1. Remove Hopper from cabinet, place the palm of your hand up against the 1 inch diameter round sensor at the back of the hopper chamber. 2. Listen for relay clicking on and off as you move your hand towards and away from the sensor. 3 If relay clicks, system is operating OK. 4 Replace with a full hopper and listen for the relay click. 5 If all this checks out and the out of product light does not go off, then there must be defective wiring. See wiring diagram. BLUE DUAL PROBE Water Inlet Valve Test 1. Turn power OFF. If the water level rises inside a partially filled tank, the Water Inlet Valve is leaking. 2. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet. If water flows in and stops when you pull it out, the Valve is working correctly. Repeat this test a few times. The problem may be in the Probe or Water Level Control Board. 3. If the water does not flow in when the cord is plugged into an electrical outlet, the Solenoid coil may be damaged, opened or the valve may have an obstruction preventing the water from flowing in. Clean or replace it. OUT OF PRODUCT SENSOR Dual Probe Liquid Level Controller Test (For models manufactured 2015 and prior) Check the Controller as follows: 1. Make sure there is power input to the Controller at the terminals AC1 & AC2 Your voltmeter should read 115 Volts. It should read the same at terminals AC1 & FILL when the water level is low. This is the output power to actuate the coil of the Solenoid Valve to open it. The lack of voltage at terminals AC1 & L-LEVEL or H-LEVEL indicates that the Controller is not working properly. 2. Make sure all wire connections are tight, including ground. 3. If after this, the Controller is still failing to open the Water Inlet Valve, replace it. HOSE NUT ASSY DUAL PROBE LIQUID LEVEL CONTROLLER N L1 TO SOLENOID TO PROBE GROUNDING PLATE IN BACK OF THE BOARD WATER INLET VALVE 12 GROUND TERMINAL 4 3 T5 2 1 SINGLE L398C [120V] DUAL L690A [120V] SINGLE L399C [220V] DUAL L706A [220V] SS WATER LEVEL CONTROL CCA Cecilware® GB Series Troubleshooting Guide Before you call for help, please read the following: WARNING: To reduce the risk of electrical shock, unplug the dispenser power cord before repairing or replacing any internal components of the unit. Before any attempt to replace a component, be sure to check all electrical connections for proper contact. Problem Merchandiser Display not lit. No power. No water when Rinse Switch is ON. No product when Dispense Button is pressed. Possible Cause Dispensing unit unplugged. No power from Terminal Block. Defective light assembly. Water supply OFF. Clogged inlet screen (Water Inlet Valve). Inoperative Water Inlet Valve. Loose electrical connection. No product in Hopper. Auger not working. Damaged, loose, or missing Agitator Gear. Inoperative Auger Motor or Relay. Water does not shut off. Water keeps dispensing. Hopper outlet clogged. Faulty Coupling. Leaking Water Inlet Valve. Inoperative Dispense Switch. Inoperative Rinse Switch. Clogged/stuck Water Dispense Valve. No water is going into tank at all. Water Inlet Valve malfunction. Water Level Sensor/ Probe malfunction. Solid State Level Control Board. Water will not stop flowing into water tank. Water Level Probe malfunction. Solenoid (Water Inlet Valve) malfunction. Solid State Water Level Control malfunction. Water is not heating up in the water tank. Heater Switch is OFF. Thermostat is OFF. (Only models with separate Thermostat) Loose connection on Thermostat. Hi-Limit Temperature Switch is defective. Heater is burned out or defective. GB Series Cecilware® Solution Reconnect dispensing unit. Check the Terminal Block for loose wire. Replace LED board. Turn water ON. Disconnect water line and clean inlet screen. Check connection, if needed replace Valve. Check all electrical connections. Add product. Engage Hopper/Nut to Motor Gear (See pg 9). Replace Agitator Gear (See pg 9). Check connections of Motor, Relay, and/or Switch; if needed replace components. Clean Hopper and check Cartridge Heater. Replace damaged Coupling components. Clean/check fittings of Water Inlet Valve. Replace Water Inlet Valve if needed. See Water Inlet Valve Test. Check Switch connections. Replace Dispense Switch if needed. Check Rinse Switch connections. Replace Rinse Switch if inoperative. Clean or unclog Water Dispense Valve. Replace Dispense Valve if inoperative. Check Solenoid. Replace if necessary. See Water Inlet Valve Test. Check Probe. Replace if necessary. See Dual Probe Test. Check Water Level Controls. Replace if necessary. See Dual Probe Liquid Level Controller Test. Check Probe. Replace if necessary. See Dual Probe Test. Check Solenoid. Replace if necessary. See Water Inlet Valve Test. Check the Water Level Controls. Replace if necessary. See Dual Probe Liquid Level Controller Test. Turn Heater Switch ON. Turn Thermostat ON. Turn Knob Clockwise. Make sure all wires and terminals on Thermostat are tight. Replace the Hi-limit. Replace the Heater. 13 Troubleshooting Guide (continued) If you still need help, call Grindmaster-Cecilware Technical Service Department, (502) 425-4776 or (800) 695-4500 option 2 (USA & Canada only) (Monday through Friday 8 AM - 6 PM EST). Please have the model and serial number ready so that accurate information can be given. Prior authorization must be obtained from Grindmaster-Cecilware for all warranty claims. Grindmaster-Cecilware provides the industry’s BEST warranty. Visit our website at GMCW.com for warranty terms and conditions. 14 Cecilware® GB Series Parts Diagram and List Hopper Illustrations HOPPER ASS'Y CD104, 7 LB, 18" HEIGHT x 3"W, W/NYLON AUGER HOPPER ASS'Y CD120, 5.5 LB, 14" HEIGHT x 3"W, W/NYLON AUGER HOPPER ASS'Y CD68A, 4 LB, 11.5" HEIGHT x 3"W, W/NYLON AUGER HOPPER ASS'Y CD313, 1 LB COFFEE, 7.875" HEIGHT x 3"W, W/NYLON AUGER HOPPER ASS'Y CD105 (14 lb; 18" HEIGHT X 6.25"SQ) W/NYLON AUGER HOPPER ASS'Y CD99A (8 lb; 11.5" HEIGHT X 6.25"SQ) W/NYLON AUGER COVER CD160 HOPPER COVER CD106 AGITATOR GEAR CD117 Agitator Gear with wire CD256 Agitator Gear with spring CD182 AUGER MOTOR CD175 90rpm AC CD87A 44rpm AC (COFFEE) CD151 90rpm DC (Portion Control) AGITATOR CD14 1 AUGER MOTOR CD175 90rpm AC CD87A 44rpm AC (COFFEE) CD151 90rpm DC (Portion Control) AGITATOR WIRE HOPPER CD105 HOPPER CD104 HOPPER CD99A HOPPER CD120 HOPPER CD68A AUGER BUSHING FRONT CD102 WITH 0-RING CD103 HOPPER CD313 AUGER BUSHING FRONT CD277 NYLON AUGER CD130 (22.5Øx18mmPT) W/"O" RING CD139 NUT [2] CD278 FLANGE/ NUT CD271 NYLON AUGER CD130 (22.5Øx18mmPT) W/"O" RING CD139 NUT [2] CD278 FLANGE/ NUT CD271 AUGER BUSHING-BACK CD279 AUGER BUSHING-BACK CD279 PRODUCT GUIDE CD70A PRODUCT GUIDE CD70A MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A DISPENSE CUP CD61A-white / CD272-black MIXING CHAMBER CD137-white / CD275 black BASE MOUNT GROMMET CD66A EXTENSION TUBE M467A - white H306A-stainless steel TWIST TO REMOVE MOUNTING BASE CD65A-white / CD317-black M379A 'O'-RING #125 CD65X - ORANGE GROMMET WHIPPER BLADE CD64A HOPPER ASS'Y CD338, 5 LB, 14"HEIGHT x 2.5"W, W/NYLON AUGER HOPPER ASS'Y CD339, 4 LB, 12.5"HEIGHT x 2.5"W, W/NYLON AUGER MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A MIXING CHAMBER CD137-white / CD275 black WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white SLINGER DISC CD124 WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white DISPENSE CUP CD61A-white / CD272-black EXTENSION TUBE M467A - white H306A-stainless steel BASE MOUNT GROMMET CD66A SLINGER DISC CD124 TWIST TO REMOVE MOUNTING BASE CD65A-white / CD317-black M379A 'O'-RING #125 WHIPPER BLADE CD143 or CD64A P - HOPPER ASS'Y CD308 LT & CD309 RT 10 LB, 14"H, W/NYLON AUGER P - HOPPER ASS'Y CD177 LT & CD178 RT 8 LB, 11.5"H, W/NYLON AUGER HOPPER COVER HOPPER COVER CD187 AUGER MOTOR CD175 90rpm AC CD87A 44rpm AC (COFFEE) CD151 90rpm DC (Portion Control) AGITATOR GEAR CD117 Agitator Gear with wire CD256 Agitator Gear with spring CD182 AGITATOR GEAR CD117 Agitator Gear with wire CD256 Agitator Gear with spring CD182 AUGER MOTOR CD175 90rpm AC CD87A 44rpm AC (COFFEE) CD151 90rpm DC (Portion Control) AGITATOR WIRE AGITATOR WIRE HOPPER CD338 HOPPER CD308 Left shown HOPPER CD339 HOPPER CD177 Left shown NUT [2] CD278 AUGER BUSHING-FRONT CD277 NYLON AUGER CD130 (22.5Øx18mmPT) W/"O" RING CD139 FLANGE/ NUT CD271 AUGER BUSHING-BACK CD279 NYLON AUGER CD130 (22.5Øx18mmPT) W/"O" RING CD139 PRODUCT GUIDE CD70A MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A MIXING CHAM. CD137 BASE MOUNT GROMMET CD66A SLINGER DISC CD124 TWIST TO REMOVE MOUNTING BASE CD65A DISPENSE CUP CD61A-white / CD272-black GB Series WHIPPER BLADE CD64A MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A MIXING CHAM. CD137 BASE MOUNT GROMMET CD66A WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white M379A 'O'-RING #125 EXTENSION TUBE M467A AUGER BUSHING-BACK CD279 PRODUCT GUIDE CD70A DISPENSE CUP CD61A WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white NUT [2] CD278 AUGER BUSHING FRONT CD277 FLANGE/ NUT CD271 EXTENSION TUBE M467A - white H306A-stainless steel Cecilware® SLINGER DISC CD124 TWIST TO REMOVE MOUNTING BASE CD65A-white / CD317-black M379A 'O'-RING #125 WHIPPER BLADE CD64A 15 Parts Diagram and List (continued) Hopper Illustrations HOPPER ASS'Y CD144, 5.5 LB, 14"Hx 3"W, W/WIRE AUGER CD101 HOPPER ASS'Y CD152, 4 LB, 11.5"H x 3"W, W/WIRE AUGER CD101 HOPPER ASS'Y CD98A, 4 LB, 11.5"H x 3"W, W/WIRE AUGER CD74A or CD153 HOPPER COVER CD106 HOPPER CD144 AGITATOR CD14 1 COVER CD160 AGITATOR GEAR CD117 [W/CD101] CD97A [W/ CD153A or CD74A] CD320 [coffee W/ CD74A] AGITATOR WIRE HOPPER CD152 HOPPER ASS'Y CD163 (14 lb; 18" HEIGHT X 6.25"SQ) W/WIRE AUGER HOPPER ASS'Y CD162 (11 lb; 14" HEIGHT X 6.25"SQ) W/WIRE AUGER HOPPER ASS'Y CD161 (8 lb; 11.5" HEIGHT X 6.25"SQ) W/WIRE AUGER HOPPER CD163 HOPPER CD162 DC MOTOR CD151 90rpm (Portion Control) DC MOTOR CD151 90rpm (Portion Control) HOPPER CD161 HOPPER CD98A AUGER BUSHING-FRONT CD102 W/"O" RING CD103 AUGER BUSHING-FRONT CD277 CD306 [W/CD74 & CD153] WIRE AUGER CD101 (22.5Øx18mmPT) CD74A (17Øx12mmPT) CD153 (17Øx9mmPT) NUT [2] CD278 FLANGE/ NUT CD271 AUGER BUSHING-BACK CD279 MIXING CHAM. CD137 WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white EXTENSION TUBE M467A WIRE AUGER CD101 (22.5Øx18mmPT) CD74A (17Øx12mmPT) CD153 (17Øx9mmPT) MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A BASE MOUNT GROMMET CD66A SLINGER DISC CD124 TWIST TO REMOVE MOUNTING BASE CD65A M379A 'O'-RING #125 DISPENSE CUP CD61A MIXING CHAM. CD137 WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white EXTENSION TUBE M467A WHIPPER BLADE CD143 or CD64A HOPPER COVER CD187 AGITATOR WIRE BASE MOUNT GROMMET CD66A SLINGER DISC CD124 TWIST TO REMOVE MOUNTING BASE CD65A M379A 'O'-RING #125 WHIPPER BLADE CD143 or CD64A HOPPER COVER AGITATOR GEAR CD117 [W/ CD101] CD97 [W/ CD153 OR CD74A] CD320 [coffee W/ CD74A] MOTOR CD151 DC 90rpm (Portion Control) AGITATOR WIRE HOPPER CD185 MOTOR CD151 DC 90rpm (Portion Control) HOPPER CD179 Left shown HOPPER CD155 AUGER BUSHING FRONT CD277 NUT [2] CD278 AUGER BUSHING-FRONT CD277 FLANGE/ NUT CD271 WIRE AUGER CD101 (22.5Øx18mmPT) MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A P - HOPPER ASS'Y CD179 (LEFT) CD180 (RIGHT) 10 LB, 14"HEIGHT, W/WIRE AUGER HOPPER ASS'Y CD185, 5 LB, 14"HEIGHT x 2.5"W, W/WIRE AUGER HOPPER ASS'Y CD155, 4 LB, 12.5"HEIGHT x 2.5"W, W/WIRE AUGER AGITATOR GEAR CD117 [W/ CD101] CD97 [W/ CD153 OR CD74A] CD320 [coffee W/ CD74A] AUGER BUSHING-BACK CD279 PRODUCT GUIDE CD70A PRODUCT GUIDE CD70A DISPENSE CUP CD61A NUT [2] CD278 FLANGE/ NUT CD271 AUGER BUSHING-BACK CD279 NUT [2] CD278 WIRE AUGER CD149 (22.5Ø x 24.8mmPT) CD74A coffee (17Øx18mmPT) FLANGE/ NUT CD271 AUGER BUSHING-BACK CD279 PRODUCT GUIDE CD70A DISPENSE CUP CD61A MIXING CHAM. CD137 WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white EXTENSION TUBE M467A 16 PRODUCT GUIDE CD70A MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A BASE MOUNT GROMMET CD66A SLINGER DISC CD124 TWIST TO REMOVE MOUNTING BASE CD65A M379A 'O'-RING #125 WHIPPER BLADE CD64A DISPENSE CUP CD61A MIXING CHAM. CD137 WHIPPER CHAMBER STRAIGHT CD63A-white STRAIGHT CD316-black SLANTED CD362-white EXTENSION TUBE M467A Cecilware® MIX BOWL SOCKET CD67A CD67A W/O-RING M378A CD100 W/O-RING M480A BASE MOUNT GROMMET CD66A SLINGER DISC CD124 TWIST TO REMOVE MOUNTING BASE CD65A M379A 'O'-RING #125 WHIPPER BLADE CD64A GB Series Parts Diagram and List (continued) Tank Assembly GB Series Cecilware® 17 Parts Diagram and List (continued) Unit Assembly (GB3M shown) INSTAN EE/DEC T COFF AFF PRESSO DT ES INSTAN ON OFF ER HEAT ONWER PO Rinse Serve CCW CCW CCW *See Metal Parts List 18 Cecilware® GB Series Parts Diagram and List (continued) Unit Assembly (GB2 SKI-SUPER shown) T HOER T WA CCW CCW CCW *See Metal Parts List GB Series Cecilware® 19 Parts Diagram and List (continued) Parts List ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 13 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39-43 44 45 46 47 48 49 50 51 52 56 57 20 DESCRIPTION TANK ASS’Y/TANK TOP ASS’Y - SEE METAL PARTS LIST - NEXT PAGE SILICONE HOSE [BREATHER FITTING] [ .375 I.D x 32”] M326A SILICONE HOSE [DISPENSE VALVE] [ .313 I.D x 14.5”] M324A SILICONE HOSE [WATER INLET] [.375 I.D. x 13”] M326A CHECK VALVE [PREVENTS BACKFLOW] [suggested – not supplied] HOSE NUT ASS’Y OR FITTING WATER INLET VALVE 120V (230V, 50HZ USE L426AL) FUSE HOLDER (120/240V ONLY) BUSSMAN SC25 FUSE (GB'S 120/240V ONLY) POWER CORD (230V, 50 HZ USE C112AL) TERMINAL BLOCK FOR 120V [WAS B117A] [FOR 240V USE B116A] RELAY CONTROL GB5M, 5K, GB6 TANK CONTROL BOARD 349-00012 (FOR 230V 50HZ USE L706AL) [PRIOR TO 10/15 - DUAL WATER LEVEL CONTROL BOARD USE L690AL - 120V & L706A - 220V) [older SINGLE WATER LEVEL CONTROL BOARD L398A - 120V & L399A - 220V] STEPDOWN TRANSFORMER (240/120V only) SPEED CONTROL BOARD [Controls Auger Speed GRAM THROW] TRANSFORMER [use w/DC motor & Speed Control CCA] RELAY, OMRON FAN CD56AL & ELBOW INSERT CD108 [USE FOR GB1, 1SKI, 2, 3, 6 ONLY] FAN CD224L w/ RW31Q Fan Housing Ass’y [GB4, 5, 2SKI ] FAN CD166L [230V 50HZ ] DUCT HOSE [for Exhaust Fan] 3/4" FEET (SET OF 4) RINSE SWITCH [GB1, GB5 & GB6-L069AL; GB2-L299AL; GB3-L446AL; GB4 L470AL] POWER SWITCH & HEATER SWITCH (120V) OR [FOR 120/240V USE L299A] HEATER INDICATOR LIGHT (amber C002AL, red C165AL) Use C072AL for GB1MLD GRILL - SEE METAL PARTS LIST - NEXT PAGE DRIP TRAY - SEE METAL PARTS LIST - NEXT PAGE WHIPPER MOTOR-short shaft (ONE PER HOPPER) (240V- CD399L) (old style CD75AL) SLINGER DISC (ONE PER HOPPER) GROMMET CHAMBER MOUNTING (TWO PER HOPPER) CHAMBER MOUNT (ONE PER HOPPER) “O” RING # 125 (used w/ grommet CD66AL) WHIP BLADE (old style used CD64AL) (ONE PER HOPPER) EXTENSION TUBE PLASTIC (ONE PER HOPPER) WHIP CHAMBER (Straight – CD63AL) OR (Slanted – CD362L) (ONE PER HOPPER) MIXING CHAMBER [ALTERNATE CD62AL W/ RECTANGULAR WING] (ONE PER HOPPER) DISPENSE CAP OR SPLASH GUARD (ONE PER HOPPER) “O” RING (#110) (used w/socket CD67A) MIXING BOWL SOCKET (ONE PER HOPPER) DISPENSE BUTTON (GB L455A) / (GB Ski Super L584A) STOP SWITCH REPLACE WITH DOOR LIGHTING ASSEMBLY 234-00131 – LIGHTING ASSEMBLY, DOOR, GB1MLP/2LP 234-00132 – LIGHTING ASSEMBLY, DOOR, GB3LP/OATMEAL 234-00133 – LIGHTING ASSEMBLY, DOOR, GB3M5.5/10 234-00134 – LIGHTING ASSEMBLY, DOOR, GB4M5.5/GB5M10 DOOR LATCH DOOR ASS’Y - SEE METAL PARTS LIST - NEXT PAGE CLEANING INSTRUCTIONS PROGRAMMING INSTRUCTIONS TIMER “TEACH ME” [PROGRAM. dispense Time/Cup Size]-Single [Triple L582A] or TIMER [NOT PROGRAM.] [use w/pot. L577A & dial/cup size labels: NF32A/33A/34A] POTENTIOMETER - USED W/SPEED CONTROL BD [GRAM THROW DIAL] LABEL, GRAM THROW DIAL- [GB2 NF30A; GB3 ND81A; GB4 NF31A] PRODUCT GUIDE (CHUTE) GB1SKI use , GB2SKI use CD234L HOPPER ASS’Y WITH COVER [w/NYLON auger] OR HOPPER ASS’Y WITH COVER [w/WIRE auger] (GB1M and GB1HC use CD99AL; GBM5.5 use CD144L; GB3M10 and GB5M10 use CD185L & CD180L) AC AUGER MOTOR (240V use CD167L) DC AUGER MOTOR 90 RPM CD151 [W/Screw P443A] Portion Control - Optional SIDE PANELS - SEE METAL PARTS LIST - NEXT PAGE LAMP HOLDER TWIN TUBE BULB 16W (240V-USE CE80AL TWIN 18W) Cecilware® GBM GB-SUPER-SKI w/ GB-SKI GBM-5.5 TEACH-ME TIMERS GB-LP GBK ß M326AL M324AL M326AL L463AL 359-00098 CD257 C032SL 60105 ß ß M326AL M324AL M326AL L463AL L462AL C032SL L533AL ß ß M326AL M324AL M326AL L463AL L462AL C032SL L533AL ß ß M326AL M324AL M326AL L463AL L462AL C032SL ß ß M326AL M324AL M326AL L463AL 359-00029 L022A C396AL CE181 C032SL B157AL ß ß M326AL M324AL M326AL L463AL L462AL C032SL 60112CWL L533AL ß B129AL ß B129AL ß B129AL ß B129AL ß CE187L L556AL CF29AL B129AL ß B129AL ß CA214L M042AL ß CA214L M042AL ß CA214L M042AL ß CA214L M042AL ß CA214L M042AL ß CA214L M042AL ß L069AL C002AL ß ß CD350L L069AL C002AL ß ß CD350L L069AL C002AL ß ß CD350L L069AL C002AL ß ß CD350L L069AL C002AL ß ß CD350L L069AL C165AL ß ß CD350L CD124L CD66AL CD65AL M379A CD353L M467AL CD63AL CD124L CD66AL CD65AL CD124L CD66AL CD65AL CD124L CD66AL CD65AL CD124L CD66AL CD65AL CD353L M467AL ß CD353L M467AL ß CD353L M467AL CD362L CD124L CD66AL CD65AL M379A CD353L M467AL CD63AL CD137L CD137L CD137L CD137L CD137L CD137L CD61AL M378A CD67AL L455AL ß CD61AL CD61AL CD61AL CD61AL CD67AL L455AL ß CD67AL L455AL ß CD67AL L455AL ß CD61AL M378A CD67AL L584AL ß CD67AL L455AL ß 61234 ß N978AL - U008AL ß NQ28AL - M705AL ß N978AL - M705AL ß N978AL - 61234 ß N978AL NF58AL L576AL - M705AL ß N978AL - CD70AL CD68AL CD70AL - CD70AL ß L557AL NF30AL CD70AL CD70AL ß CD105L CD105L CD180L & CD185L CD98AL CD155L GB6 CD353L M467AL CD362L - CD175L ß B216AL CD175L ß B216AL CD175L ß B216AL CD175L ß B216AL CD175L CD151L ß B216AL CD175L ß B216AL CE82AL CE82AL CE82AL CE82AL CE82AL CE82AL GB Series Parts Diagram and List (continued) Metal Parts List MODELS ITEM 1 ITEM 23 TANK ASS’Y TANK & TOP Only ITEM 23 GRILL ITEM 24 ITEM 45 DRIP TRAY DOOR ASS’Y ITEM 53 SIDE PANELS SC01QL (LIT) GB1M SPACE SAVER TI17QL (NONLIT) RH91AL RI12A RH48Q RG48AL M673AL-CLEAR .125 M674Q RI19A RI12A RH48Q RG48AL M673AL-CLEAR .125 M674Q RT72AL SQ14A RY89QL RG48AL M674Q-WINDOW/ M673AL-CLEAR BRKT DOOR ASSY, .125 CLEAR RI20AL RH05AL RH49Q RG48AL M704Q-WINDOW/ M703A-CLEAR BRKT DOOR ASSY, CLEAR SC35QL GB2M-5.5 SC36CL SC36QL RI19A GB3M-5.5 SC36CL SC36QL GB3M-10 SC36CL SC36QL RL69CL-TOP & RL72QL-TANK COMPONENTS& TOP ONLY NO TANK ITEM 55 WINDOW ASS’Y M774AL-CLEAR M775Q=(2) M775AL + BRACKET .125 M775AL-CLEAR .040 RT67AL OR RT61A OR RI23AL RI11AL SC35CL GB4M-5.5 ITEM 54 WINDOW SJ61CL SJ61QL RR34AL RR33AL SD82Q RG48AL M704Q-WINDOW/ M703A-CLEAR BRKT DOOR ASSY, CLEAR SC35CL SC35QL RK44AL RM21QL 210-00162 RG48A M464AL-CLEAR M464M-MILKY 3K-GB SC35CL RK47AL RM23QL RF79Q RD46A 4K-GB RL72CL SC35QL RL72QL-TANK & TOP RZ80AL RZ79AL RZ07QL RD46A M465AL-CLEAR M702AL-CLEAR WINDOW M465M-MILKY M702ML-MILKY WINDOW 5K-GB RL72CL RL72QL-TANK & TOP RZ80AL RZ79AL RZ07QL RD46A M702ML-MILKY WINDOW M702M SC35CL SC35QL SC25AL SC26AL SC01QL SC33AL M711AL CLEAR WINDOW M712QL=M711AL (2), BRACKET, AND EYELETS GB3-LP SC36CL SC36QL SC30SL SC31AL SB30QL SC33AL M684AL CLEAR .125 M685AL CLEAR .040 GB4-LP SC36CL SC36QL SC57AL SC58AL SC62QL SC33AL M703A CLEAR .125 M704Q CLEAR .040 RL54QL TANK & TOP RT67A RT61A RX81CL RL51AL M414AL-CLEAR PANEL - RN21QL RN21PL RQ78AL RQ16QL TB34QL RN21CL RN16CL RQ78AL RQ16AL RN61Q M703A M704Q GB5M-10 2K-GB GB2-LP GB1-SKI-LD BUDGET W/ MOLDED DOOR LOW PROFILE SKI GB2-SKI-LD GB2-Super-SKI GB6M GB Series Super SKI SJ61CL SJ61QL TANK & TOP SM14AL SM13AL Cecilware® TF43CL RR70BL (LEFT) RR71BL (RIGHT) RN33A SL76AL M892AL-FRONT CLEAR 0.040 M892ML-BACK MILKY 0.060 M893AL-CLEAR WINDOW 0.125 21 Parts Diagram and List (continued) Tank Parts List Item Description GB1 GB2M-5.5 GB3M-5.5 GB3M-10 GB4M-5.5 GB5M-10 2K-GB 3K-GB K525AL K525AL K525AL K525AL K525AL K525AL K525AL K525AL K525AL 4K-GB 1 ELBOW TUBE 2 DISPENSE VALVE (DUMP)* L467AL L467AL L467AL L467AL L467AL L467AL L467AL L467AL L467AL 3 GROMMET, SILICONE, (0.466 ID) M461AL M461AL M461AL M461AL M461AL M461AL M461AL M461AL M461AL 4 DUAL LEVEL PROBE K695QL K695QL K695QL K695QL K695QL K695QL K695QL K695QL K695QL 5 HI-LIMIT, #500, 200°F CUTOUT L656AL L656AL L656AL L656AL L656AL L656AL L656AL L656AL L656AL 6 M773AL M773AL M773AL M773AL M773AL M773AL M773AL M773AL M773AL K667QL K667QL K667QL K667QL K667QL K667QL K667QL K667QL K667QL 8 O-RING SHIM ASSEMBLY, HEAT SINK W/HI-LIMIT BRACKET SCREW, S.S., 1/4 - 20 x 5/8 - - - - - - - 9 HEATER, 120V, 1700W* G267TL G267TL G267TL G267TL G267TL G267TL G267TL G267TL G267TL HEATSINK, 1/8" ALU. F/ HI-LIMIT K661AL K661AL K661AL K661AL K661AL K661AL K661AL K661AL K661AL 61128 61128 61128 61128 61128 61128 61128 THERMOSTAT (2015 and prior) L532AL L532AL L532AL L532AL L532AL L532AL L532AL L532AL L532AL M600AL - M601AL M601AL M879AL M879AL M600AL M600AL M500AL ß ß ß ß ß ß ß 14 SILICONEGASKET TANK WELDMENT ASS'Y (SEE METAL PARTS LIST) TANK INSULATION MATERIAL - - - - - - - 15 DRAIN HOSE, SILICONE M326AL M326AL M326AL M326AL M326AL M326AL M326AL 7 10 11 12 13 THERMISTOR PROBE (New 2015) - 61128 - 61128 ß ß - - M326AL M326AL 16 DRAIN HOSE, SILICONE - - - - - - - 17 DRAIN HOSE, SILICONE M324AL M324AL M324AL M324AL M324AL M324AL M324AL M324AL M324AL 18 DRAIN HOSE, SILICONE M326AL M326AL M326AL M326AL M326AL M326AL M326AL M326AL M326AL 19 DRAIN PLUG M391AL M391AL M391AL M391AL M391AL M391AL M391AL M391AL M391AL 20 PLUG, SILICON M494AL M494AL M494AL M494AL M494AL M494AL M494AL M494AL M494AL Description 5K-GB GB2-LP GB3-LP GB4-LP GB1-SKI-LD GB2-SKI-LD GB2-Super-SKI GB6M ELBOW TUBE K525AL K525AL K525AL K525AL K525AL K525AL K525AL K525AL Item 1 - 2 DISPENSE VALVE (DUMP)* L467AL L467AL L467AL L467AL L467AL L467AL L467AL L467AL 3 GROMMET, SILICONE, (0.466 ID) M461AL M461AL M461AL M461AL M461AL M461AL M461AL M461AL K695QL 4 DUAL LEVEL PROBE K695QL K695QL K695QL K695QL K695QL K695QL K695QL 5 HI-LIMIT, #500, 200°F CUTOUT L656AL L656AL L656AL L656AL L656AL L656AL L656AL L656AL 6 O-RING SHIM ASSEMBLY, HEAT SINK W/HI-LIMIT BRACKET SCREW, S.S., 1/4 - 20 x 5/8 M773AL M773AL M773AL M773AL M773AL M773AL M773AL M773AL K667QL K667QL K667QL K667QL K667QL K667QL K667QL K667QL - - - - - - - - 9 HEATER, 120V, 1700W* G267TL G267TL G267TL G267TL G402AL G402AL G402AL G267TL 10 HEATSINK, 1/8" ALU. F/ HI-LIMIT K661AL K661AL K661AL K661AL K661AL K661AL K661AL K661AL 61128 L532AL M008AL M500AL 61128 L532AL M008AL - 61128 L532AL M008AL - 61128 L532AL M008AL - 61128 L532AL M008AL M601AL 61128 L532AL M008AL M607AL 61128 L532AL M008AL 61128 L532AL M008AL M879AL ß ß ß ß ß ß ß ß 14 THERMISTOR PROBE (New 2015) THERMOSTAT (2015 and prior) THERMOSTAT KNOB (≤2015) SILICONE GASKET TANK WELDMENT ASS'Y (SEE METAL PARTS LIST) TANK INSULATION MATERIAL - - - - - - - - 15 DRAIN HOSE, SILICONE M326AL M326AL M326AL M326AL M326AL M326AL M326AL M326AL 16 DRAIN HOSE, SILICONE - - - - - - - - 7 8 11 12 13 17 DRAIN HOSE, SILICONE M324AL M324AL M324AL M324AL M324AL M324AL M324AL M324AL 18 DRAIN HOSE, SILICONE M326AL M326AL M326AL M326AL M326AL M326AL M326AL M326AL 19 DRAIN PLUG M391AL M391AL M391AL M391AL M391AL M391AL M391AL M391AL PLUG, SILICON M494AL M494AL M494AL M494AL M494AL M494AL M494AL M494AL 20 - * EXPORT MODELS 2 DISPENSE VALVE - L676AL 9 HEATER, 240V 3000W - G266AL 22 Cecilware® GB Series Wiring Diagrams GB1, GB1M, GB1MD (120V, 1700W, 1 PH, 2 wires + Ground) w/ Relay DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 5 H-LEVEL 6 COMMON LED WATER TANK GB Series 4 L-LEVEL GND Cecilware® 23 Wiring Diagrams (continued) GB2, GB2M, GB2M, 2K (120V, 1700W, 1 PH, 2 wires + Ground) w/ Relays DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 6 COMMON LED WATER TANK 24 4 L-LEVEL 5 H-LEVEL GND Cecilware® GB Series Wiring Diagrams (continued) GB2, GB2M, 2K GB2, 2M, 2MD, 2K, [120/240V, 3KW, 1PH, L1, L2, NTL, GND] W/RELAYS DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 5 H-LEVEL 6 COMMON LED WATER TANK GB Series 4 L-LEVEL GND Cecilware® 25 Wiring Diagrams (continued) GB3, GB3M, GB3MD, 3K (120V, 1700W, 1 PH, 2 wires + Ground) w/ Relay DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 5 H-LEVEL 6 COMMON LED WATER TANK 26 4 L-LEVEL GND Cecilware® GB Series Wiring Diagrams (continued) GB3, GB3M (120V/240, 3kW, 1 PH, L1, L2, +NTL + GND) w/ Relays BLK BLK BREW SW BREW SW BREW SW BRO WHT WHT GND BLK YEL N BRO DOOR UNIT WHT BLK AUGER MOTOR AC WHT BLK GND WHT AUGER MOTOR AC BLK AUGER MOTOR AC RINSE SWITCH N N DISPENSE VALVE DISPENSE VALVE DISPENSE VALVE N WHIPPER MOTOR AC COM 3 RELAY 2 NO WHIPPER MOTOR AC 4 1 COM 3 RELAY 2 NO WHIPPER MOTOR AC 4 COM 1 3 2 NO 4 1 RELAY N BLUE L1 N N DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED WHT L1 BLK 1 FILL 2 AC-1L 3 AC-2N N N BLU YEL GRN WATER LEVEL PROBES 4 L-LEVEL 5 H-LEVEL 6 COMMON LED WATER TANK GND THERMOSTAT BLK HEATER LIGHT 3KW-HEATER FUSE 6A HEATER SWITCH HI-LIMIT RED L1 WHT POWER SWITCH N L2 L1 G GND GB Series Cecilware® 27 Wiring Diagrams (continued) GB3M, 3K (120V/240, 6kW, 1 PH, L1, L2, +NTL + GND) w/ Relays 28 Cecilware® GB Series Wiring Diagrams (continued) GB3M-W [120V, 1.7KW, 1 PH, 2 WIRES + GROUND] W/ RELAYS DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 5 H-LEVEL 6 COMMON LED WATER TANK GB Series 4 L-LEVEL GND Cecilware® 29 Wiring Diagrams (continued) GB4, GB4M, 4M-8, 4MD [120V, 1.7KW, 1 PH, 2 WIRES + GROUND] W/ RELAYS DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 5 H-LEVEL 6 COMMON LED WATER TANK 30 4 L-LEVEL GND Cecilware® GB Series Wiring Diagrams (continued) GB5M [120V, 1.7KW, 1 PH, 2 WIRES + GROUND] W/ RELAYS GB Series Cecilware® 31 Wiring Diagrams (continued) GB6M 120V 32 GB6M-10-LD-U Cecilware® GB Series Wiring Diagrams (continued) GB2SKI-SUPER [SINGLE PHASE W/TEACH ME TIMERS] 240 V.AC 6 KW HOT CHOCOLATE 2 1 4 3 HOT-WATER TEACH-ME TIMER 2 1 2 1 4 3 4 3 DISPENSE SWITCH 4+ BLU WHT HOT WATER DISPENSE VALVE 1 3 2 RELAY NO GND 4+ BLU TRANSFORMER RINSE SWITCH 3 2 RELAY 1 COM DISPENSE VALVE D.C. AUGER MOTOR BLK WHT 4 1 2 YEL BLK WHT 3- SPEED CONTROL D.C. AUGER MOTOR GND MAIN UNIT 2 TRANSFORMER COM POT 3- SPEED CONTROL DOOR UNIT HOT WATER SW. POT YEL TEACH-ME TIMER DISPENSE SWITCH STOP SW. 1 L1 HOT CHOCOLATE NO 4 BLK N DISPENSE VALVE DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 4 L-LEVEL 5 H-LEVEL 6 COMMON LED WATER TANK GND FAN 3 TANK HEATERS - 1 PHASE - 6 KW FUSE WHT HEATER LIGHT 120V 3 2 1 L3 L2 L1 CONTACTOR 110V COIL 3 2 1 T1 220V BLK TRANSFORMER POWER SWITCH GND HI-LIMIT THERMOSTAT HEATER SWITCH 10GA L1 10GA L2 G GND GB Series Cecilware® 33 Wiring Diagrams (continued) GB2SKI-SUPER 3 PHASE, W/TEACH ME TIMERS 240 V.A.C. 18 KW HOT CHOCOLATE 2 1 4 3 HOT CHOCOLATE HOT-WATER TEACH-ME TIMER 2 1 4 3 TEACH-ME TIMER 2 1 4 3 DISPENSE SWITCH DISPENSE SWITCH STOP SW. HOT WATER SW. DUAL LIQUID LEVEL CONTROL WATER INLET VALVE RED BLK 1 FILL WHT 2 AC-1L 3 AC-2N BLU YEL GRN WATER LEVEL PROBES 6 COMMON LED WATER TANK 34 4 L-LEVEL 5 H-LEVEL GND Cecilware® GB Series GB Series Cecilware® 35 Grindmaster-Cecilware 4003 Collins Lane, Louisville, KY 40245 USA Phone: 502.425.4776 Toll Free: 800.695.4500 Fax: 502.425.4664 Web: gmcw.com Email: [email protected] ©2016 Grindmaster-Cecilware Printed in USA 0516 Form # CW-314-01 Part # 390-00013
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project