advertisement
▼
Scroll to page 2
of
22
Digital 3 phase Voltage Relay <DSP-DVR/DVR-M,DM II Meter> Contents 1. Abstraction 2. Main Features 3. Operation Time 4.Technical Specification 5.Preset Description 6. The order of Rotated Mode 7.PIN Assignment 8.Indication 9.Control Key Operation 10.Over voltage trip time characteristic 11.Trip Indication 12.Rotated Indication 13.Time-Voltage based Trip Output 14.Application Sequence Diagram 15.Dimension 16.Order Form Digital 3 phase Voltage Relay <DSP-DVR/DVR-M,DM II meter> 1.Abstraction Installation Panel Mounting Type Panel Flush MountingType Model Protection Indication DSP-DVR DSP-DVR-M Panel Mounting Type *Over Voltage *Under Voltage *Phase Loss *Reverse Phase *Line/Average Voltage *Frequency Panel Flush Mounting Type 2.Main Features MCU based control, 8 Pin Type Compact size Easy Installation : Panel Mounting Type → DSP-DVR : Panel Flush Mounting Type → DSP-DVR-M Operation based on direct line voltage detection : Protection : Over/Under voltage, Phase Loss, Reverse Phase, Voltage Unbalance : Indication : Voltage[Line/Average], Frequency :Time-Voltage operational characteristic → Definite / Inverse Over/Under Voltage Protection :Rated Line Voltage → 100 ~ 500VAC :Over Voltage protection Range → within (+) 20% to line voltage : Under Voltage protection Range → above (–) 20% to line voltage Possible to preset operation time for over/under voltage each, repectively Perfect check for initial line state a)”dt”(trip delay time) mode is preset “OFF” ▸Preset “a” in “out” mode :Main trip output(95-98) is energized (Open → Close ) in case the rated line voltage with normal forward phase state is sensed initially : Main trip output(95-98) is trip(Close → Open) within 0.5sec after energizing(Open→Close) if the initial state is under phase loss : Main trip output(95-98) is trip(Close → Open) after operational preset time is elapsed from instant energizing point(Open→Close) as showing a trip cause if the initial line state is under over/under voltage,reverse phase, voltage unbalance : v.OFF is shown in case the line voltage is not sensed initially or voltage is dropped to zero(0) while the normal operation is doing. ▸Preset “b” in “out” mode :Main trip output(95-98) is not energized (Open → Open ) even if the rated line voltage with normal forward phase state is sensed initially : Main trip output(95-98) is trip(Open → Close) within 0.5sec if the initial state is under phase loss : Main trip output(95-98) is trip(Open →Close) after operational preset time is elapsed as showing a trip cause if the initial line state is under over/under voltage,reverse phase, voltage unbalance : v.OFF is shown in case the line voltage is not sensed initially or voltage is dropped to zero(0) b)”dt”(trip delay time) mode is preset a value(time) ▸Preset “a” in “out” mode : Main trip output(95-98) is energized (Open → Close ) after “dt” is elapsed in case the rated line voltage with normal forward phase state is sensed initially : Main trip output(95-98) is still opened(not trip) even after “dt” is elapsed if the initial state is under phase loss,also “PL’ is shown : Main trip output(95-98) is energized (Open → Close) right after “dt” is elapsed if the initial line state is under over/under voltage, voltage unbalance, and then it is trip(Close → Open) after operational preset time is elapsed from energizing point(Open→Close) as showing a trip cause : v.OFF is shown in case the line voltage is not sensed initially or voltage is dropped to zero(0) while the normal operation is doing. :”rP” is shown as main trip output(97-98) is still opened(not trip) after operational trip time (0.5sec) without concerning with “dt” if reverse state is sensed initially ▸Preset “b” in “out” mode : Main trip output(95-98) is not energized (Open → Open ) in any case : Main trip output(95-98) is trip (Open → Close) after “dt” is elapsed if the initial state is under phase loss as “PL’ is shown :Main trip output(95-98) is trip (Open → Close) right after “dt”is elapsed as showing a trip cause if the initial line state is under over/under voltage, voltage unbalance : v.OFF is shown in case the line voltage is not sensed initially or voltage is dropped to zero(0) :”rP” is shown as main trip output(97-98) is still closed(not trip) after operational trip time (0.5sec) without concerning with “dt” if reverse state is sensed initially Trip cause is shown by characters and/or numbers : 4 Digit Window/DVR Type : 5 Digit Window/DVR-M Type 3 phase line voltage/average voltage and /or frequency is shown ordery in every 3sec Stored the information for latest 8 trip event. Reset after a trip : auto or manual Self-diagnostics to check if this relay is ready to work or not. 3.Operation Time Over Voltage *definite :0.2~20sec *Inverse :1~10 Class *ovt” mode Under Voltage 1~20sec : “uvt” mode Reverse Phase Within 0.5sec/initial phase state Phase Loss 0.5~5sec : “PL” mode Voltage Unbalance 1~10sec :” v-ut” mode 4.Technical Specification DIV Line Voltage Protection range Description Line Input:V1,V2,V3 100 ~500VAC,50/60Hz Over voltage Under 20% based on the line voltage Under voltage Protection delay time(dt) Over voltage trip delay time(ovt) Over 20% based on the line voltage 1~60 sec/definite *0.2~20 sec/definite *1~10 Class/inverse Under voltage trip delay time(uvt) Reverse Phase(RP) Phase Loss(PL) Voltage unbalance Voltage Allowable tolerance Time Time preset 1~20 sec/definite Within 0.5 sec 0.5~5sec/definite 1~10sec ±3% *t<=2sec:± 0.2sec, t>2sec:±10% *Reverse phase:+10% Control power *AC 85V∼AC260V,50/60Hz (DC90V∼DC370V) Trip output relay *DC24V(Optional) 1c(1-SPDT),5A/Resistive Application environment 95-96-98 Operation -25OC∼+70OC Storage -40OC∼+80OC Temperature Humidity 30∼85% , relative/non-condensing Insulation Resistence/IEC-60255-5 Case–Circuit: 10Mohm/500VDC High Voltage Withstand Test/ IEC-60255-5 *Case–Circuit:AC2000V,60Hz,1 min *Contact-Contact:AC 1000V,60Hz,1 min Lightning Impulse Voltage Withstand Test/ IEC*Circuit-Ground,Circuit-Circuit: 1.2/50(uS),5KV 60255-5 *Control Circuits:1.2/50(uS), 5KV 1 MHz Burst Immunity Test:IEC 61000- 4-18 2.5KV,Positive/Negative under 2sec Electrostatic Discharge:IEC-61000-4-2 Air :Level 3, 8KV, Contact:Level 3, 6KV Radiated Electromagnetic Field Disturbance:IEC-61000-4-3 Level 3, 10V/m Electric Fast Transient Burst :IEC-61000-4-4 Power,trip output:Level 4,4KV Surge Immunity test:IEC-61000-4-5 trip output :1.2X50uS,2KV(0O,90O, 180O , 270O) Conducted Disturbence Test :IEC-61000-4-6 10V, Level 3 Screw Torque Max0.6N.m Consuming power 4W Max 5.Preset description ▶ Main Mode Press "SET" key to enter into setting mode ,then enter password. The more detail is described in "Operation of Control key " Mode P*** Out/a/b LInE/OFF/ setting Value Function Description * "P000"(factory default password) is shown *Move cursor from first digit to right end digit by pressing "CLR" key,finally press once more if password is not changed from factory default value, but if password is changed, then make required digit by Password input using "UP","DN" key untill operator meets changed password. *Make power-on again as keeping both “UP” and “DN” key pressed under power-off in order to make an initialization to factory default * initial state of main trip output is defined as followed condition. ▸a : main trip output/95-98(1a) is energized (open→close) in case normal forwarded voltage is sensed after control power is loaded ▸b : main trip output/95-98(1a) is not energized (open→open) in case normal forwarded voltage is to select initial state of main sensed after control power is loaded trip output * initial trip is happened without concerning with above definition for initial state if one of over/under voltage,voltage unbalance,phase loss and reverse phase is sensed ▸phase loss : trip right after sensing. ▸reverse phase,voltage unbalance,over/under voltage : trip after preset time is elapsed. *OFF:the sensed voltage is only shown as trip output is to select line not come out voltage * to define the value of incoming line voltage:100~ 500VAC Factory Default 000 a 440 *1P:single phase motor/disable for phase loss & reverse 3P to select PhAS/ phase, voltage unbalance /voltage must be loaded phase of power 1P/3P between L1 and L2 line *3P:3 phase motor protection to select a base *L : to show line voltage to display trAn/L/A *A : to show average voltage incoming voltage to preset a time *OFF : disable dt/OFF/setting to stop *1~60sec/definite,adjustable value protection *all protective function except reverse state is stopped function during “dt”,but detected voltage is shown *OFF : disable *to protect over voltage according to preset value in "LInE" mode *protection range : under 20% based on line input ov/OFF/setting to protect over voltage value voltage *Auto reset is possible only after a sensed voltage is dropped under preset valued voltage after a time of “AUo” mode is elapsed continuously *Auto reset is done in case line voltage is not loaded *This mode is not available in case initial PL(phase loss) is happened to define voltage-trip *dEF : definite Otc/dEF/Inv time *Inv : Inverse charateristics to preset trip *to preset trip delay time after sensed voltage is over ovt/setting delay time to preset value value protect over *definite : 0.2∼20sec/adjustable voltage *inverse : 1~10 Class uv/OFF/ to preset trip *OFF : disable setting delay time to *to protect under voltage according to preset value in value protect ubder "LInE" mode voltage *protection range:over 20% based on line input voltage *Auto reset is possible only after a sensed voltage is risen over preset valued voltage after a time of “AUo” mode is elapsed continuously *This mode is not available in case initial PL(phase loss) is happened to preset trip *to preset trip delay time after sensed voltage is under uvt/setting delay time to preset value value protect under *1∼20sec/definite,adjustable voltage L OFF OFF dEF 1 OFF 10 *OFF : disable *trip in case voltage unbalance rate is over 45% :[(max-min)/max]*100[%] * 0.5 ~ 5 sec/definite,adjustable to protect phase *In case 3 phase is normal power-off state, this mode is PL/oFF/ setting loss by not worked. value incoming line *This protection is not available for the load such as a voltage motor which the reversed voltage can be created by the internal common point of 3 phase line ,but available for initial phase loss *This mode is not available for single phase line. RP/oFF/ setting to protect *OFF : disable value reverse phase * within 0.5sec by incoming *In case 3 phase is normal power-off state or phase line voltage loss state , this mode is not worked. *Auto reset is not possible,but manual reset. *”dt” is not interfaced with this mode v-Ub/oFF/ setting value to preset voltage unbalance protection rate(%) v-Ut/setting value to preset operating trip * to preset a operating trip time for voltage unbalance delay time for *Adjustable range: 1~10 sec voltage unbalance rESt/Hr/Er *trip in case preset rate condition is kept on preset time or more *rate:[(Max V-Min V)/Max V]*100 [%] *adjustable range:5%~30% to decide how *to decide how to reset in case of trip to reset trip *Hr : manual reset by key touch state →Password Input :rP ,PL/trip state is still remained even in case of power OFF-ON,but possible only by password input →”CLR” key: OV,UV,v-UB → not possibl to preset setting value under trip state *Er : electrical reset → "CLR" Key → Control power off → Auto reset : “OV”, “UV”, “v-Ub” :possible to reset naturally after preset time by “AUT” mode is elapsed if trip cause is clear → not possibl to preset setting value under trip state OFF OFF oFF 3초 Er caused by “PL” and “RP”,but possible to preset under trip state caused by “OV”, “UV” and “v-Ub Aut to decide auto reset time 3 *possible to preset auto reset time in case “Er” is preset in “rESt” mode *1sec~10 sec to decide OFF *OFF/basic factor : line voltage/average voltage additional [L1,L2,L3] to indicate orderly in every 3 sec. factor besides rotA/ON/OFF *ON : frequencty is added to basic factor basic factor to *possible to fix one of rotated factor or to release as indicate value pressing "CLR" key repeatedly in the order *to check latest 8 trip cause to show latest *press "UP" or "DN" in the "trip" mode, then trip cause trIP /8 ~1/trip 8 trip cause and value is shown alternatively cause / trip orderly *press "CLR" or ""SET" to check next event or previous -value event *In order to enter setup state on the way of trip condition check, press "DN" or "UP" *oFF : disable for this mode to preset delay *preset time:1sec~10sec time to show v-ot/oFF/ *”v-ot” is shown initially if voltage is not detected “v-oFF’ if setting during an operation, but finally ”v-oFF’ is shown after voltage is not value preset time is elapsed detected while *operational condition for “v-oFF” in “out” mode working shall be applied for this mode as well Test *to check if this relay is ready to work normally or not. *"tESt" is appeared in case the operator press "CLR" key for 3 sec or more, then release pressed "CLR" key when “tESt” is shown *Trip output(95-98) will be energized after counting down preset ovt-time *press “CLR” key to reset after test trip ▶ Cab(calibration) Mode This mode is appeared as pressing "SET" key for 10 sec or more ,and is disappeared as "SET'key once more Mode Function P*** Password Input vrPE to have a Description *need to input password to adjust this mode group so that authorized person may be able to adjust. *How to input is aame as it of main mode *to show present sensed voltage Factory Default 000 0 vsPE vtPE ` calibration for *Possible to adjust with +,- 1V step size with 100V adjust phase "L1" range voltage to have a calibration for phase "L2" voltage to have a calibration for phase "L3" voltage to change Password *Possible to enter new digit by using "UP" or "DN" key after positioning a cursor on the required digit *Press both "SET" & "CLR" key in order to come out setting mode and the changed password is stored. 6. The order of Rotated Mode 0 0 000 7.PIN Assignment DIV Input Output Socket Pin 2 7 5 4 3 5 4 6-8-1 8. Indication feature Description * Control Voltage/AC 85V∼AC260V,50/60Hz (DC90V∼DC370V) Phase L1 voltage 3 Phase application Phase L2 voltage Phase L3 voltage Phase L1 voltage 1 phase application Phase L2 voltage Main trip/95-96-98,1c(SPDT) 9.Control key Operation *Note: trip will be occurred after completing preset process if trip condition is happened during preset process *Press "SET" Key to enter into setting mode, then "P000"/”P0000” (factory default password) is shown *Move cursor from first digit to right end digit by pressing "CLR" key, finally press once more if password is not changed from factory default 1.”SET” key value, but if password is changed, then make required digit by using "UP","DN" key untill operator meets changed password. *If there is no input for 15sec or pressing both "SET" and "CLR"key, it can be entered into operating condition. *After entering into possible state for preset , each key acts its job as 2. Changed follows :SET→backward direction ,CLR→foward direction ,UP,DN→ feature of Setting able to select number or character in preset mode. Key *The previous mode based on setting mode is come out as pressing "SET" key during doing a prest job 3."SET" Key & "CLR" Key/ to *Possible to select Mode by using "SET" or "CLR" key select MODE 4."UP" key & *Possible to preset required value as selection a character or number by "DN"Key/Adjust using UP/DOWN *The storage for preset data is completed by pressing both SET and CLR 5."SET" & key in the same time or after 15sec is elapsed "CLR"Key/ *The character and/or a number that is already preset in the above preset Store process is stored in one times. *While each factor is rotated, one of rotated factor is fixed by pressing "CLR" key and released as pressing once more 6.“CLR" key *After fixing a operating factor, the operator is able to rotate manually one by one as pressing "UP"(forwardly), "DN" (reversely) *Average voltage is shown without rotating if average voltage is selected. *possible to check preset and/or change value of each mode as pressing To check and/or “SET” key once during operation, change preset *”P000”/”P0000” is shown as pressing “SET” key value of each *preset value and mode are appeared alternatively and to check an/or change mode during preset value operation *next mode as pressing “CLR” Key Self-Test/Reset : "CLR" Key *return to operating mode as pressing both “SET” and "CLR" key or waiting for 15sec without any touch *to check if this relay is ready to work normally or not. *"tESt" is appeared in case the operator press "CLR" key for 3 sec or more only in case control power is loaded,without loading V1,V2,V3 , then release pressed "CLR" key *Trip output(95-98) will be trip after counting down preset ovt time as showing “0-0” *Make reset a trip as press “CLR” key once more 10.Over voltage trip time characteristic 11.Trip indication Trip cause and caused value is appeared alternatively Trip Display Cause Over voltage *trip caused by over voltage in phase L1-L2 Under voltage *trip caused by under voltage in phase L1-L2 Reverse phase * trip caused initially by reverse phase of incoming power line Phase loss *trip caused by phase loss of incoming power line, phase L2 *Indication is shown based on “RP” condition if phase loss is occurred under “RP” state Volarge unbalance *trip caused by voltage unbalance in L1-L2 *The difference value of [max-min] and “vub” is shown anlternatively Zero voltage *to show that voltage is not sensed *The operation voltage is dropped under 35V while normal operation is done or zero(0) initially 12. Rotated indication ▸If line voltage value with normal phase order is sensed after the control power is loaded, then 3 phase line voltage indication is rotated ▸output(95-98) is energized (Open→Close) as normal phase voltage is loaded if out” mode is preset “a” ▸output(95-98) is not energized (Open→Open) if out” mode is preset “b” ▸however v.oFF is shown if the voltage is not sensed or the voltage is dropped into 0V(Zero Volt) while normal operation is done ▸If single phase is applied. V-OFF or actual voltage is shown ▸”dt”(trip delay time) mode is preset “OFF” a)Preset “a” in “out” mode •Main trip output(97-98) is trip at once in case initial line phase state is phase loss •Main trip is energized ,then is trip after operational trip time is elapsed in case initial line phase state is under reverse phase,over/under voltaege and voltage unbalance as each mode is preset valued condition,also trip cause is shown b)Preset “b” in “out” mode •”PL” is shown during “dt” in case initial line phase state is phase loss, consequently main trip output(97-98) is trip right after “dt” is elapsed •Main trip output(97-98) is trip after the sum of “dt” and operational time is elapsed in case initial line phase state is under reverse phase,over/under voltaege and voltage unbalance as each mode is preset valued condition,also trip cause is shown ▸”rotA” Mode : OFF → voltage of L1, L2, L3 ▸”rotA” mode: ON → voltage of L1,L2,L3, Frequency ▸Average voltage : same as a case of line voltage by “rotA” ON,OFF ▸Bar graph indication : DSP-DVR-M Type Operational state The ratio of a sensed voltage to preset “ov” value is shown e.g. preset value for “ov”:400V, sensed voltage :320V, then bar graph:80% Trip state 13.Time-Voltage based trip output ▸Over Voltage : “out” mode/a, trip caused by over-voltage during a normal operation ▸Over Voltage : “out” mode/b, trip caused by over-voltage during a normal operation ▸ Over/Under voltage: “out” mode/a, auto reset after trip during a normal operation ▸ Over/Under voltage: “out” mode/b, auto reset after trip during a normal operation 14.Application Sequence Diagram 15.Dimension ▶DSP-DVR ▶DSP-DVR-M ▪ Converter ▪ Display meter 16.Order form DIV 1 2 3 Type Control Power Frequency Reference Code DSP-DVR DSP-DVR-M DSP-SOCKET-8P DSP-DVR DSP-DVR-M B Z 7 Description Panel Mounting Type Panel Flush Mounting Type 24VDC(Optional) 85~260VAC(90~370VDC) 50/60Hz Description Panel Mounting Type,3Phase incoming voltage,8PIN Socket embedded, Control power/85~260VAC (90~ 370 VDC), Possible to fix line voltage in “Line” mode:100~500 VAC Panel Flush Mounting Type,3Phase incoming voltage, 8PIN Socket embedded,Control power/85~260VAC(90~ 370VDC),Possible to fix line voltage in “Line” mode: 100~500 VAC 8PIN Socket
advertisement
Related manuals
advertisement