About this document

This manual is intended for administrators and users of the AXIS P5534

Network Camera, and is applicable to firmware 5.40 and later. It includes instructions for using and managing the product on your network. Previous experience of networking will be of use when using this product. Some knowledge of UNIX or Linux-based systems may also be beneficial, for developing shell scripts and applications.

Later versions of this document will be posted to the Axis website, as required. See also the product’s online help, available via the web-based interface.

Liability

Every care has been taken in the preparation of this manual. Please inform your local Axis office of any inaccuracies or omissions. Axis

Communications AB cannot be held responsible for any technical or typographical errors and reserves the right to make changes to the product and manuals without prior notice. Axis Communications AB makes no warranty of any kind with regard to the material contained within this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Axis

Communications AB shall not be liable nor responsible for incidental or consequential damages in connection with the furnishing, performance or use of this material. This product is only to be used for its intended purpose.

Intellectual Property Rights

Axis AB has intellectual property rights relating to technology embodied in the product described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the patents listed at http://www.axis.com/patent.htm and one or more additional patents or pending patent applications in the US and other countries.

This product contains licensed third-party software. See the menu item

“About” in the product’s user interface for more information.

This product contains source code copyright Apple Computer,

Inc., under the terms of Apple Public Source License 2.0 (see http://www.opensource.apple.com/apsl). The source code is available from http://developer.apple.com/darwin/projects/bonjour/

Equipment Modifications

This equipment must be installed and used in strict accordance with the instructions given in the user documentation. This equipment contains no user-serviceable components. Unauthorized equipment changes or modifications will invalidate all applicable regulatory certifications and approvals.

Trademark Acknowledgments

Apple, Boa, Bonjour, Ethernet, Internet Explorer, Linux, Microsoft,

Mozilla, Real, SMPTE, QuickTime, UNIX, Windows, Windows Vista and

WWW are registered trademarks of the respective holders. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Oracle and/or its affiliates. UPnP

TM mark of the UPnP TM Implementers Corporation.

is a certification

Support

Should you require any technical assistance, please contact your Axis reseller. If your questions cannot be answered immediately, your reseller will forward your queries through the appropriate channels to ensure a rapid response. If you are connected to the Internet, you can:

• download user documentation and software updates

• find answers to resolved problems in the FAQ database. Search by product, category, or phrase

• report problems to Axis support staff by logging in to your private support area

• chat with Axis support staff (selected countries only)

• visit Axis Support at www.axis.com/techsup/

Electromagnetic Compatibility (EMC)

This equipment has been designed and tested to fulfill applicable standards for:

Radio frequency emission when installed according to the instructions and used in its intended environment.

Immunity to electrical and electromagnetic phenomena when installed according to the instructions and used in its intended environment.

USA

Depending on the characteristics of the electrical environment, using shielded cables (STP) may be appropriate, in which case the following is applicable: This equipment has been tested using shielded cables

(STP) and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help

Canada

This Class B digital apparatus complies with Canadian ICES-003.

Europe

This digital equipment fulfills the requirements for RF emission according to the Class B limit of EN 55022.

This product fulfills the requirements for immunity according to

EN 61000-6-1 residential, commercial and light-industry environments.

This product fulfills the requirements for immunity according to

EN 61000-6-2 industrial environments.

This product fulfills the requirements for immunity according to

EN 55024 office and commercial environments.

Australia/New Zealand

This digital equipment fulfills the requirements for RF emission according to the Class B limit of AS/NZS CISPR 22.

Korea

이 기기는 가정용(B급) 전자파적합기기로서 주로 가정에서 사

용하는 것을 목적으로 하며, 모든 지역에서 사용할 수 있습니다.

Japan

この装置は、クラスB 情報技術装置です。この装置は、家庭

環境で使用することを目 的としていますが、この装置がラジ

オやテレビジョン受信機に近接して使用されると、 受信障

害を引き起こすことがあります。 取扱説明書に従って正し

い取り扱いをして下さい。

AXIS P5534 PTZ Dome Network Camera

Table of Contents

Hardware overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Midspan LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Accessing the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Access from a browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Access from the Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Set the root password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

The Live View page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Media streams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

How to stream H.264 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

MJPEG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

AXIS Media Control (AMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Alternative methods of accessing the video stream . . . . . . . . . . . . . . . . . . . .

13

Accessing audio streams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Setting up the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Video and Audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

Video Stream . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

Stream Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

Camera Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Privacy Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Audio Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Audio Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

Live View Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

PTZ (Pan Tilt Zoom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25

Preset Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25

Gatekeeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25

Guard Tour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26

OSDI Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26

Advanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26

Control Queue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

27

Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

Motion Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

Audio detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29

Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30

Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

Convert Event Types to Action Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32

Setting Up an Action Rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32

Recipients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33

Schedules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33

Recurrences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

34

Recordings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

Recording List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

Continuous recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

System Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

Date & Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

38

Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

39

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

43

Ports & Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

44

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

44

Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

45

Advanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

46

Reset to factory default settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

46

Multi-Connector Cable (sold separately) . . . . . . . . . . . . . . . . . . . . . . . .

47

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

49

Checking the firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

49

Upgrading the firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

49

Emergency recovery procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

49

3

AXIS P5534 PTZ Dome Network Camera

Table of Contents

Symptoms, possible causes and remedial actions . . . . . . . . . . . . . . . . . . . . . .

50

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

54

Performance considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

56

4

AXIS P5534 PTZ Dome Network Camera

Hardware overview

Hardware overview

1

3

2

4

5 6

7

1

Part number (P/N) & Serial number (S/N)

2

Network connector (High PoE)

3 Multi-connector

4

Control button

5

SD memory card slot

6

Status LED indicator

7

Restart button

Connectors

Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet Plus (PoE+) IEEE 802.3at. Use the supplied midspan.

Caution

Due to local regulations or the environmental and electrical conditions in which the product is to be used, a shielded network cable (STP) may be appropriate or required. Any network cables that are routed in outdoor environments or similar shall be

shielded (STP) and intended for their specific use. Make sure that the midspan is properly grounded. See Electromagnetic

Compatibility (EMC) for regulatory requirements.

SD card slot - A standard or high-capacity SD card (not included) can be used for local recording with removable storage. For instructions on how to insert and remove an SD card, please refer to the Installation Guide.

Note

Before removal, the SD card should be unmounted to prevent corruption of recordings. To unmount the SD card, go to

Setup

> System Options > Storage > SD Card and click Unmount.

Control button - The control button is used for:

• Connecting to an AXIS Video Hosting System service. See page 40. To connect, press and hold the button for about

1 second until the Status LED flashes green.

5

AXIS P5534 PTZ Dome Network Camera

Hardware overview

• Connecting to AXIS Internet Dynamic DNS Service. See page 40. To connect, press and hold the button for

about 3 seconds.

• Resetting the product to factory default settings. See page 46.

Restart button - Press to restart the product.

Multi-connector - Terminal connector for connecting external equipment:

• Audio equipment

• Input/Output (I/O) devices

• AC/DC power supply

When connecting external equipment, a multi-connector cable (available from Axis) is required in order to maintain the product’s IP

rating, see Multi-Connector Cable (sold separately), on page 47.

LED indicators

Color

Unlit

Amber

Amber/red

Red

Green

Indication

Connection and normal operation

Steady during startup. Flashes during firmware upgrade.

Flashes amber/red if network connection is unavailable or lost.

Flashes red for firmware upgrade failure.

Shows steady green for 10 seconds for normal operation after restart.

Note

• The Status LED can be configured to flash while an event is active.

Midspan LED indicators

LED

Port

Color

Unlit

AC input

Green

Green, flashing

Green, flashing

Green

Indication

No camera connected.

Steady when camera connected, normal operation.

Slow flash when over current or short circuit condition on the port.

Fast flash when input voltage is out of range or other internal error.

Steady when AC power connected.

6

AXIS P5534 PTZ Dome Network Camera

Accessing the product

Accessing the product

To install the Axis product, refer to the Installation Guide supplied with the product.

The product can be used with most operating systems and browsers. The recommended browsers are Internet Explorer with Windows,

Safari with Macintosh and Firefox with other operating systems. See Technical Specifications, on page 54.

Note

• To view streaming video in Internet Explorer, allow installation of AXIS Media Control (AMC) when prompted.

• QuickTime

TM is also supported for viewing H.264 streams and for audio.

• If your computer restricts the use of additional software components, the product can be configured to use a Java applet for viewing Motion JPEG.

• The Axis product includes (1) H.264 decoder license for viewing video streams and (1) AAC audio license. These licenses are automatically installed with AMC. The administrator can disable the installation of the decoders, to prevent installation of unlicensed copies.

Access from a browser

1. Start a browser (Internet Explorer, Firefox, Safari).

2. Enter the IP address or host name of the Axis product in the browser’s Location/Address field. To access the product from a

Macintosh computer (Mac OS X), click on the Bonjour tab and select the product from the drop-down list.

If you do not know the IP address, use AXIS IP Utility to locate the product on the network. For more information on how to discover and assign an IP address, refer to the Installation Guide.

3. Enter your user name and password. If this is the first time the product is accessed, the root password must first be

configured; for instructions see Set the root password, on page 8 .

4. The product’s Live View page appears in your browser.

Note

The layout of the Live View page may have been customized to meet specific requirements. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View page.

7

AXIS P5534 PTZ Dome Network Camera

Accessing the product

Access from the Internet

Once connected, the Axis product is accessible on your local network (LAN). To access the product from the Internet you must configure your network router to allow incoming data traffic to the product. To do this, enable the NAT-traversal feature, which will attempt to automatically configure the router to allow access to the product. This is enabled from

Setup > System Options >

Network > TCP/IP Advanced.

For more information, please see NAT traversal (port mapping) for IPv4, on page 41. See also AXIS Internet Dynamic DNS Service at

www.axiscam.net For Technical notes on this and other topics, visit the Axis Support web at www.axis.com\techsup

Set the root password

To gain access to the Axis product, you must set the password for the default administrator user

root. This is done in the Configure

Root Password dialog, which appears when the product is accessed for the first time.

To prevent network eavesdropping, the root password can be set via an encrypted HTTPS connection, which requires an HTTPS certificate. HTTPS (Hypertext Transfer Protocol over SSL) is a protocol used to encrypt traffic between web browsers and servers. The

HTTPS certificate ensures encrypted exchange of information.

To set the password via a standard HTTP connection, enter it directly in the first dialog.

To set the password via an encrypted HTTPS connection, follow these steps:

1. Click

Create self-signed certificate.

2. Provide the requested information and click

OK. The certificate is created and the password can now be set securely. All traffic to and from the product is encrypted from this point on.

3. Enter a password and then re-enter to confirm the spelling. Click

OK. The password has now been configured.

Note

• The default administrator user name

root is permanent and cannot be deleted.

• If the password for root is lost, the product must be reset to the factory default settings. See Reset to factory default

settings, on page 46.

The Live View page

If the Axis product has been customized to meet specific requirements, not all the items described below will appear in the Live View page. The following provides an overview of each available button.

8

AXIS P5534 PTZ Dome Network Camera

Accessing the product

Controls on the Live View page

Click

View size to scale the image down to 800 pixels wide or to full scale. Only available in MJPEG.

The

Stream Profile drop-down list allows you to select a customized or pre-programmed stream profile. Stream profiles are configured under

Video & Audio > Stream Profiles. See Stream Profiles, on page 17.

Click

Pulse to activate the output for a defined period of time, such as switching on an external light for 20 seconds.

Click the

Active/Inactive buttons to manually start and stop a connected device — e.g. switch an external light on and off.

The Manual Trigger button can trigger an event directly from the Live View page. The button is configured under

Live View Config > Action Buttons.

Click

Snapshot to save a snapshot of the video image. Right-click the video image to save it in JPEG format on your computer. This button is primarily intended for use when the AXIS Media Control viewer toolbar is not available.

Enable this button from

Live View Config > Action Buttons.

The Audio clip drop-down list allows you to play an audio clip from the Live View page. Select the audio clip and click the Play button.

Activate the product’s fan with this button. Enable this button from Live View Config > Action Buttons. The Fan button is activated automatically. Press this button to activate it manually.

Enable or disable the

Gatekeeper by selecting On or Off from the drop-down list. See page 25 for more information

about Gatekeeper.

AXIS Media Control viewer toolbar

The AXIS Media Control viewer toolbar is available in Internet Explorer only. See AXIS Media Control (AMC), on page 12 for more

information. The toolbar displays the following buttons:

The

Play button connects to the Axis product and starts playing a media stream.

The Stop button stops the media stream.

The Snapshot button takes a snapshot of the video image. The location where the image is saved can be specified in the AMC Control Panel.

Click the

View Full Screen button and the video image will fill the entire screen. Press ESC (Escape) on the computer keyboard to cancel full screen view.

The

Record button is used to record the current video stream. The location where the recording is saved can be specified in the AMC Control Panel.

9

AXIS P5534 PTZ Dome Network Camera

Accessing the product

AMC Audio controls

AMC audio buttons control the speakers and microphone connected to the client computer. The buttons are only visible when audio is enabled.

Speaker button — Click to turn the speakers on or off.

Microphone button – Click to mute or unmute the microphone. In Simplex - Network Camera speaker only mode, click this button to stop sending audio to the product.

Use the slider to control the volume of the speakers and the microphone.

Half-duplex mode

The Talk/Listen button is used to switch between sending and receiving audio. The button can be configured from the Audio tab in the AMC Control panel:

• Push-To-Talk mode: Click and hold the button to talk/send. Release the button to listen.

• Toggle mode: Click once to switch between talking and listening.

Simplex – Network Camera speaker only mode

To send audio, the Talk and Microphone buttons must both be enabled. Click either button to stop audio transmission.

PTZ Controls

The Live View page also displays Pan/Tilt/Zoom (PTZ) controls. The administrator can enable/disable controls for specified users under

System Options > Security > Users.

With the PTZ Control Queue enabled the time each user is in control of the PTZ settings is limited. Click the buttons to request or release control of the PTZ controls. The PTZ Control Queue is set up under PTZ > Control Queue.

Click the Emulate joystick mode button and click in the image to move the camera view in the direction of the mouse pointer.

Click the Center mode button and click in the image to center the camera view on that position. The center mode button could also be used to zoom in on a specific area. Click in the image and drag to draw a rectangle surrounding the area to be magnified. To zoom out, rotate the mouse wheel.

Click the

Ctrl panel button to open the PTZ control panel which provides additional PTZ controls.

User-defined buttons can also appear in the Control panel. See Controls, on page 27.

Select a PTZ preset position to steer the camera view to the saved position. See Preset Positions,

on page 25.

10

AXIS P5534 PTZ Dome Network Camera

Accessing the product

Pan and Tilt bars – Use the arrows to pan and tilt the camera view, or click on a position on the bar to steer the camera view to that position.

Zoom bar – Use the arrows to zoom in and out, or click on a position on the bar to zoom to that position.

Focus bar – Use the arrows to focus the camera, or click on a position on the bar to set the focus position. Using the focus bar will disable the product’s autofocus. To re-enable, use the PTZ control panel which is opened by clicking the

Ctrl panel button (see above).

Iris bar – Click on a position on the iris bar to change the degree to which the iris is opened. This will disable the product’s auto iris. To re-enable, use the PTZ control panel which is opened by clicking the

Ctrl panel button (see above).

The PTZ controls can be disabled under

PTZ > Advanced > Controls, see Controls, on page 27.

11

AXIS P5534 PTZ Dome Network Camera

Media streams

Media streams

The Axis product provides several audio and video stream formats. Your requirements and the properties of your network will determine the type you use.

The Live View page in the product provides access to H.264 and Motion JPEG video streams, audio streams and to the list of available stream profiles. Other applications and clients can access video and audio streams directly, without going via the Live View page.

How to stream H.264

The video compression standard H.264 makes good use of bandwidth, and can provide high quality video streams at less than 1 Mbit/s.

Deciding which combination of protocols and methods to use depends on your viewing requirements, and on the properties of your network. The available options in AXIS Media Control are:

Unicast RTP

RTP over RTSP

RTP over RTSP over HTTP

Multicast RTP

This unicast method (RTP over UDP) is used for live unicast video, especially when it is important to always have an up-to-date video stream, even if some images are dropped.

This unicast method (RTP tunneled over RTSP) is useful as it is relatively simple to configure firewalls to allow RTSP traffic.

Unicasting is used for video-on-demand transmission so that there is no video traffic on the network until a client connects and requests the stream.

Note that there are a maximum of 20 simultaneous unicast connections.

This unicast method can be used to traverse firewalls. Firewalls are commonly configured to allow the HTTP protocol, thus allowing RTP to be tunneled.

This method (RTP over UDP) should be used for live multicast video. The video stream is always up-to-date, even if some images are dropped.

Multicasting provides the most efficient usage of bandwidth when there are large numbers of clients viewing simultaneously. A multicast cannot however, pass a network router unless the router is configured to allow this. It is not possible to multicast over the Internet, for example.

Note also that all multicast viewers count as one unicast viewer in the maximum total of 20 simultaneous connections.

AXIS Media Control negotiates with the Axis product to determine the transport protocol to use. The order of priority, listed in the

AMC Control Panel, can be changed and the options disabled, to suit specific requirements.

Note

H.264 is licensed technology. The Axis product includes one H.264 viewing client license. Installing additional unlicensed copies of the client is prohibited. To purchase additional licenses, contact your Axis reseller.

MJPEG

This format uses standard JPEG still images for the video stream. These images are then displayed and updated at a rate sufficient to create a stream that shows constantly updated motion.

The Motion JPEG stream uses considerable amounts of bandwidth, but provides excellent image quality and access to every image contained in the stream. The recommended method of accessing Motion JPEG live video from the Axis product is to use the AXIS

Media Control in Internet Explorer in Windows.

AXIS Media Control (AMC)

AXIS Media Control (AMC) in Internet Explorer in Windows is the recommended method of accessing live video from the Axis product.

12

AXIS P5534 PTZ Dome Network Camera

Media streams

The AMC Control Panel can be used to configure various video and audio settings. Please see the AXIS Media Control User’s

Manual for more information.

The AMC Control Panel is automatically installed on first use, after which it can be configured. Open the AMC Control Panel from:

• Windows Control Panel (from the Start menu)

• Alternatively, right-click the video image in Internet Explorer and click

Settings.

Alternative methods of accessing the video stream

You can also access video and images from the Axis product in the following ways:

Motion JPEG server push (if supported by the client, Firefox, for example). This option maintains an open HTTP connection to the browser and sends data as and when required, for as long as required.

Still JPEG images in a browser. Enter the path http://<ip>/axis-cgi/jpg/image.cgi

Windows Media Player. This requires AXIS Media Control and the H.264 decoder to be installed. The following paths can be used:

Unicast via RTP: axrtpu://<ip>/axis-media/media.amp

Unicast via RTSP: axrtsp://<ip>/axis-media/media.amp

Unicast via RTSP, tunneled via HTTP: axrtsphttp://<ip>/axis-media/media.amp

Multicast: axrtpm://<ip>/axis-media/media.amp

QuickTime TM

. The following paths can be used:

rtsp://<ip>/axis-media/media.amp

rtsp://<ip>/axis-media/media.3gp

13

AXIS P5534 PTZ Dome Network Camera

Media streams

Note

• <ip>= IP addess

• The Axis product supports QuickTime 6.5.1 and later.

• QuickTime adds latency to the video stream.

• It may be possible to use other players to view the H.264 stream using the paths above, although Axis does not guarantee this.

Accessing audio streams

The Live View page provides access to audio through AXIS Media Control; in addition audio can be accessed in the following ways:

VAPIX® Application Programming Interface (API) For more information, visit www.axis.com/developer

Windows Media Player supports simplex audio. The following paths can be used:

Unicast via RTP: axrtpu://<ip>/axis-media/media.amp

Unicast via RTSP: axrtsp://<ip>/axis-media/media.amp

Unicast via RTSP, tunneled via HTTP: axrtsphttp://<ip>/axis-media/media.amp

Multicast: axrtpm://<ip>/axis-media/media.amp

QuickTime

TM

supports G.711 and AAC audio encoding. The following paths can be used:

rtsp://<ip>/axis-media/media.amp

rtsp://<ip>/axis-media/media.3gp

• The

Java applet supports simplex audio with G.711 encoding.

14

AXIS P5534 PTZ Dome Network Camera

Setting up the product

Setting up the product

The Axis product can be configured by users with administrator or operator rights. Click

Setup in the top right-hand corner of the Live View page.

Administrators have unrestricted access to all settings.

Operators have access to all settings except System Options

See also the online help .

Basic Setup

Basic Setup provides shortcuts to the settings that should be made before using the Axis product:

1. Users. See page 37.

2. TCP/IP. See page 39.

3. Date & Time. See page 38.

4. Video Stream. See page 16.

5. Audio Settings. See page 19.

The Basic Setup menu can be disabled from

System Options > Security > Users.

15

AXIS P5534 PTZ Dome Network Camera

Video and Audio

Video and Audio

The video and audio settings can be used to optimize video and audio quality. You can configure the following:

• Video stream settings. See page 16.

• Stream profiles. See page 17.

• Camera settings. See page 17.

• Overlay image. See page 19.

• Privacy mask. See page 19.

• Audio settings. See page 19.

• Audio clips. See page 21.

Video Stream

You can define the following video stream settings from Video & Audio > Video Stream:

• Image. See page 17.

• H.264. See page 17.

• MJPEG. See page 17.

Pixel Counter

The pixel counter shows the number of pixels in an area of the image. The pixel counter is useful in situations where there is a requirement that the image is a certain size, for example in face recognition.

The pixel counter can be accessed from:

Video & Audio > Video Stream. Under Preview, click Open and select the Show pixel counter option to enable the rectangle in the image. Use the mouse to move and resize the rectangle, or enter the number of pixels in the

Width

and

Height fields and click Apply.

16

AXIS P5534 PTZ Dome Network Camera

Video and Audio

• The Live View page in Internet Explorer in Windows. Right-click in the image and select

Pixel counter. Use the mouse to move and resize the rectangle.

Image

You can modify the image resolution and compression, and rotate the image from the

Image tab (Video & Audio > Video Stream).

Setting the compression level affects the image quality and bandwidth; the lower the compression, the higher the image quality with higher bandwidth requirements.

To avoid bandwidth problems on the network, you can limit the frame rate allowed to each viewer. The maximum frame rate can be set to

Unlimited, or you can limit the frame rate to a value.

An image or text can be superimposed over the image as overlay. See Overlay, on page 19.

Save your settings before they can take effect.

H.264

H.264, also known as MPEG-4 Part 10/AVC, is a video compression standard that provides high quality video streams at low bit rates.

An H.264 video stream consists of different types of frames such as I-frames, P-frames and B-frames. An I-frame is a complete image whereas P-frames and B-frames only contain the differences from previous/future frames.

The

GOV length is the number of frames between two consecutive I-frames. Increasing the GOV length may save considerably on bandwidth requirements in some cases, but may also have an adverse affect on image quality.

The bit rate can be set as Variable Bit Rate (VBR) or Constant Bit Rate (CBR). VBR adjusts the bit rate according to the image complexity, using up more bandwidth for increased activity in the image, and less for lower image activity. CBR allows you to set a fixed Target bit rate that consumes a predictable amount of bandwidth. As the bit rate would usually need to increase for increased image activity, but in this case cannot, frame rate and image quality are affected negatively. To partly compensate for this, it is possible to prioritize either frame rate or image quality. Not setting a priority means that frame rate and image quality are equally affected. You must save your settings before they can take effect.

The current bit rate can be set to appear as text overlay. To do this, select the Include text check box option under Overlay

Settings and enter the modifier#b in the field.

MJPEG

Sometimes the image size is large due to low light or complex scenery. Adjusting the maximum frame size helps to control the bandwidth and storage used by the Motion JPEG video stream in these situations. Setting the frame size to the

Default setting provides consistently good image quality at the expense of increased bandwidth and storage usage in low light. Limiting the frame size optimizes bandwidth and storage usage, but may give poor image quality. To prevent increased bandwidth and storage usage, the maximum frame size should be set to an optimal value.

Stream Profiles

There are four pre-programmed stream profiles available for quick set up. The settings for these can be adjusted. New customized profiles can also be created. Each profile has a descriptive name, indicating its purpose.

• The stream profiles can be accessed from the Stream profile drop-down list in the Live View page.

• To add, copy, modify, and remove stream profiles go to Video & Audio > Stream Profiles.

• To select the default stream profile go to

Live View Config > Stream Profile and choose the profile from the drop-down list.

For more information see the online help on this page.

Camera Settings

The

Video & Audio > Camera Settings page provides access to advanced image settings for the Axis product.

17

AXIS P5534 PTZ Dome Network Camera

Video and Audio

Image Appearance

Increasing the

Color level increases the color saturation. The value 100 gives maximum color saturation. The value 0 gives a black and white image.

The image Brightness can be adjusted in the range 0–100, where a higher value produces a brighter image.

Increasing the Sharpness can increase bandwidth usage. A sharper image might increase image noise especially in low light conditions. A lower setting reduces image noise, but the whole image will appear less sharp.

White balance

White balance is used to make colors in the image appear the same regardless of the color temperature of the light source. The Axis product can be set to automatically identify the light source and compensate for its color. Alternatively, select the type of light source from the drop-down list. For a description of each available setting, see the online help .

Wide Dynamic Range (Dynamic Contrast)

Wide dynamic range (Dynamic Contrast) can improve the exposure when there is a considerable contrast between light and dark areas in the image. In intense backlight conditions, enable WDR. Disable WDR In low light conditions for optimal exposure.

Note

This setting is only possible when using automatic exposure control.

Exposure Settings

Configure the exposure settings to suit the image quality requirements in relation to lighting, frame rate and bandwidth considerations.

Exposure control - These settings is used to adapt to the amount of light used. Automatic is the default settings can be used in most situations. The shutter speed is automatically set to produce optimum image quality.

Max exposure time - Select the maximum exposure time from the drop-down list. Increasing the exposure time will improve image quality, but decrease the frame rate. There may also be an increase in motion blur. Checking

Allow slow shutter decreases the shutter speed in low light to improve image brightness.

Enable Backlight compensation - Enable this option if a bright spot of light, for example a light bulb, causes other areas in the image to appear too dark.

Exposure zones - This settings determines which part of the image is used to calculate the exposure. For most situations, the Auto setting can be used. For particular requirement, select a predefined area.

Max gain - Measured in decibels (dB), gain describes the amount of amplification applied to a signal, in this case the visual information in the image. A high level of amplification may provide a better image in very low light situations. A high gain will also increase the amount of image noise.

Day/Night

The IR cut filter prevents infrared (IR) light from reaching the image sensor. In poor lighting conditions, for example at night, or when using an IR lamp, set the IR cut filter to Off. This increases light sensitivity and allows the product to “see” infrared light. The image is shown in black and white when the IR cut filter is off.

If using automatic Exposure control, set the IR cut filter to Auto to automatically switch between On and Off according to the lighting conditions.

Image settings

Autofocus enabled - Automatic focusing is enabled by default. If the focus position is changed manually using the focus bar,

autofocus will be disabled even if enabled here. In this case, use the PTZ control panel to enable autofocus, see PTZ Controls, on page

10. If required, the focus control can be disabled under PTZ > Advanced > Controls.

18

AXIS P5534 PTZ Dome Network Camera

Video and Audio

Image freeze on PTZ - Select All movements to freeze the image while the camera is moving during a pan, tilt or zoom operation.

Once the camera reaches its new position, the view from that position is shown.

Presets freezes the image only when the camera moves between preset positions.

Overlay

Overlays can be used to provide extra information and are superimposed over the video image. With overlay text it is possible to include date and time or view the current bit rate as overlay text.

To include the current bit rate as overlay text go to Video & Audio > Video Stream > Overlay Settings, select the Include text check box option, and enter the overlay code in the field. See the online help for supported formats.

Overlay image

An overlay image can be used to provide extra information, or to mask a part of the video image.

To use your own image, such as a logo, first upload the image to the Axis product. Go to

Video & Audio > Overlay Image, click

Browse to locate the file and then click Upload. The file can then be selected from the Use overlay image drop-down list.

To place an overlay image at specific coordinates, go to

Video & Audio > Video Stream and select the Include overlay image at

coordinates check box option and enter the X and Y coordinates.

For more information see the online help

Privacy Mask

A privacy mask is an area of solid color that prohibits users from viewing parts of the monitored area. Privacy masks cannot be bypassed via the VAPIX® Application Programming Interface (API).

The Privacy Mask List, Video & Audio > Privacy Mask, shows all the masks that are currently configured in the Axis product and indicates if they are enabled.

The Pan/Tilt/Zoom coordinates of the privacy mask are locked in their position. This means that regardless of the angle and zoom of the lens, the same place or object will be hidden. To define at what magnification the mask should be displayed, zoom to the desired level and click

Set level.

You can add a new mask, re-size the mask with the mouse, choose a color for the mask, and give the mask a name.

For more information, see the online help

Audio Settings

The audio functionality for each video stream is enabled under

Video & Audio > Video Stream > Audio.

Note

A multi-connector cable (available from Axis; Multi-Connector Cable (sold separately)) is required when connecting external

audio equipment to the Axis product.

Audio Channels

Select the type of audio transmission from the Audio mode: drop-down list (Video & Audio> Audio Settings). The different types are:

Full duplex - Simultaneous two-way audio allowing you to transmit and receive audio (talk and listen) at the same time. There is no echo cancellation; if feedback loops appear, try moving the microphone or the speaker.

Half-duplex - Audio can be transmitted in both directions between the Axis product and the client computer, but only in one direction at a time. You must actively receive sound using the

Talk/Listen button visible in the Live View page (see AXIS Media

19

AXIS P5534 PTZ Dome Network Camera

Video and Audio

Control viewer toolbar). In Push-To-Talk mode, click and hold the button to speak and release it when done. In Toggle mode, click

once to switch between speaking and listening. The

Talk/Listen mode is configured from the Audio tab in the AMC control panel

(see AXIS Media Control on page 12).

Simplex - speaker only - Audio is transmitted from the client to the Axis product and played by the speaker connected to the product. To send audio, the

Talk and Microphone buttons in the AMC toolbar must both be enabled. Click either button to stop audio transmission.

Simplex - microphone only - Audio captured by the microphone connected to the Axis product is transmitted from the product to one or more clients.

For more information about these settings, please see the online help .

Audio Input

An external microphone or a line source can be connected to the product’s Audio-in connector. Configure the audio input settings under Video & Audio > Audio Settings.

Note

A multi-connector cable (available from Axis; Multi-Connector Cable (sold separately)) is required when connecting external

audio equipment to the Axis product.

Source - Select Microphone for an external microphone or Line for a Line in device, e.g. an audio mixer for multiple microphones or a microphone with a built-in amplifier.

Microphone power - The Enable microphone power option provides DC power for an external microphone. Microphone power should only be used with microphones that have no battery. This setting should not be enabled when using a dynamic or battery powered microphone. Microphone power will not harm the microphone; if you are uncertain, try switching it off and on. To use a professional microphone requiring 48V phantom power, you need an external power supply and a balanced-unbalanced converter

(audio transformer) in between.

Input gain - Control the volume (dB Full Scale) of the audio input. If the sound is too low, choose a higher dB, to amplify the sound. If the sound is too high, choose a lower dB. The Level bar gives a visual representation of the audio signal level in dB relative to the full-scale input level.

• Green — the signal is at a good level.

• Yellow — the signal is becoming distorted.

• Red — the signal is distorted.

Encoding - Select digital audio encoding format.

AAC requires a license for both encoding and decoding. AAC is the least complicated and most widely used codec.

If achieving the best possible audio quality is a priority, AAC is the recommended codec to use. An AAC license is included in the Axis product.

G711

G726

Sample rate - The number of times per second the sound is sampled. A higher sample rate will provide better audio quality, but also requires a greater bandwidth.

Bit rate - Set the required bit rate depending on the selected encoding. A higher bit rate will give better audio quality. A lower bit rate may have latency or delay, but will require less bandwidth.

For more information about these settings, please see the online help .

20

AXIS P5534 PTZ Dome Network Camera

Video and Audio

Audio Output

An external speaker can be connected to the product’s Audio-out connector. The output can be used with high impedance headphones or connected to another amplifier with speakers.

Configure the audio output settings under Video & Audio > Audio Settings.

Note

A multi-connector cable (available from Axis; Multi-Connector Cable (sold separately)) is required when connecting external

audio equipment to the Axis product.

Output gain - Control the volume (dB Full Scale) of the line audio output. If the sound is too low, choose a higher dB. If the sound is too high, choose a lower dB.

Audio Clips

An audio clip is a sound file that can be played either when an event occurs or manually from the

Live View page. Audio clips can be uploaded to the product or recorded by a microphone connected to the product.

You can add, play, download, modify and remove audio clips from

Video & Audio > Audio Clips. For more information see the online help .

Note

Audio clips cannot be used if the product’s audio functionality is enabled. The audio functionality is enabled on the

Audio

tab under

Video & Audio > Video Stream.

21

AXIS P5534 PTZ Dome Network Camera

Live View Config

Live View Config

You can customize the Live View page and alter it to suit your requirements. It is possible to define the following features of the Live View page.

• Stream Profile. See page 17.

• Default Viewer for Browser. See page 22.

• Viewer Settings. See page 23.

• Action Buttons. These are the buttons described in Controls on the Live View page, on page 9 .

• User Defined Links. See page 23.

• Output Buttons. See page 23.

Default viewer for browsers

From Live View Config > Default Viewer select the default method for viewing video images in your browser. The product attempts to show the video images in the selected video format and viewer. If this is not possible, the product overrides the settings and selects the best available combination.

22

AXIS P5534 PTZ Dome Network Camera

Live View Config

Browser

Windows Internet Explorer

Other browsers

Viewer

AMC

QuickTime

Java applet

Still image

Server Push

QuickTime

Java applet

Still image

Description

Recommended viewer in Internet Explorer (H.264/Motion JPEG)

H.264

A slower imaging alternative to AMC (Motion JPEG). Requires one of the following installed on the client:

• JVM (J2SE) 1.4.2 or higher

• JRE (J2SE) 5.0 or higher

Displays still images only. Click the Refresh button in your browser to view a new image

Recommended viewer for other browsers (Motion JPEG).

H.264

A slower imaging alternative to Server Push (Motion JPEG only).

Displays still images only. Click the Refresh button in your browser to view a new image

For more information, please see the online help .

Viewer Settings

Options for the viewer are configured under

Live View Config > Viewer Settings.

• The

Show viewer toolbar option will display the AXIS Media Control (AMC) or the QuickTime viewer toolbar under the video image in your browser.

• H.264 decoder installation. The administrator can disable installation of the H.264 decoder included with AXIS Media

Control. This is used to prevent installation of unlicensed copies. Further decoder licenses can be purchased from your

Axis reseller.

• Select Show crosshair in PTZ joystick mode to enable a cross that will indicate the center of the image in PTZ joystick mode.

• Select

Use PTZ joystick mode as default to enable joystick mode. The mode can be changed temporarily from the PTZ control panel.

• You can enable recording from the Live View page. The recordings are saved to the location specified in the AMC Control

Panel. See AXIS Media Control (AMC), on page 12.

User Defined Links

To display user-defined links in the Live View page, select the Show custom link option, give the link a name and then enter the URL to link to. When defining a web link do not remove the 'http://' from the URL address. Custom links can be used to run scripts or activate external devices connected to the product, or they can link to a web page. Custom links defined as cgi links will run the script in the background, in a hidden frame. Defining the link as a web link will open the link in a new window.

Output Buttons

An output on the Axis product can be controlled directly from the Live View page, by enabling the display of output buttons. To display the output buttons in the Live View page, select the type of control to use for the port from the drop-down list under

Live View Config > Output Buttons:

Pulse activates the output for a defined period of time. The pulse time can be set as short as 1/100 second, and as long as 60 seconds

Active/Inactive displays two buttons (on/off). The output ports must first be configured under System Options> Ports &

Devices > I/O Ports. See I/O Ports, on page 44.

23

AXIS P5534 PTZ Dome Network Camera

Live View Config

Note

A multi-connector cable (available from Axis) is required when connecting external I/O devices to the Axis product. See

Multi-Connector Cable (sold separately), on page 47

24

AXIS P5534 PTZ Dome Network Camera

PTZ (Pan Tilt Zoom)

PTZ (Pan Tilt Zoom)

Preset Positions

A preset position is a predefined view that can be used to quickly steer the camera to a specific location. Preset positions can be accessed in several ways:

• By selecting the preset from the Preset positions drop-down list in the Live View Page.

• When setting up action rules. See page 31.

• When setting up Guard Tour. See page 26.

• When setting up the Gatekeeper. See page 25

To add a preset position:

1. Go to PTZ > Preset Positions.

2. Use the pan, tilt and zoom controls to steer the camera view to the desired position.

3. Enter a descriptive name in the

Current position field.

4. If required, select

Use current position as Home.

5. Click Add. The camera’s position, iris and focus settings are saved as a preset position.

The Home position is readily accessible by clicking the Home button on the Live View page and in the Preset Positions setup window.

To set a customized home position, select

Use current position as Home when adding a preset position. The user-defined home position will have (H) added, for example, Entrance (H). The default Home position, called “Home”, will still be available.

The product can be configured to return to the Home position when the PTZ functionality has been inactive for a specified length of time. Enter the length of time in the

Return to home when inactive field and click Save. Set the time to zero to prevent the product from automatically returning to the Home position.

To include the preset position name in the overlay text, go to

Video & Audio, select Include overlay text and enter the modifier #P in the field. For more information about modifiers, see File Naming & Date/Time Formats in the online help .

Gatekeeper

The Gatekeeper monitors an area such as an entrance gate. It can pan, tilt and zoom in, and take a snapshot of, for example, a face, triggered by movement in the area. The camera will then automatically return to the home position and continue to overview the monitored area.

25

AXIS P5534 PTZ Dome Network Camera

PTZ (Pan Tilt Zoom)

To configure the Gatekeeper, follow the online instructions under

PTZ > Gatekeeper.

Guard Tour

A guard tour displays the video stream from different preset positions, one-by-one, in a predetermined order or at random and for configurable time periods. The enabled guard tour will keep running after the user has logged off or closed the browser.

To add a guard tour:

1. Go to PTZ > Guard Tour and click Add.

2. Enter a descriptive name.

3. Specify the pause length between runs.

4. Select an available preset position and click

Apply.

5. Specify the Move speed.

6. Specify the View Time in seconds or minutes.

7. Specify the

View order or select the Random view order check box option.

8. Click

Save.

To modify or remove guard tours, go to

PTZ > Guard Tour, select the guard tour in the Guard Tour List and click Modify/Remove.

For more information see the online help .

Note

The pause between guard tour runs must be set to at least 10 minutes.

OSDI Zones

On-Screen Direction Indicator (OSDI) zones can be included in the overlay text (see Overlay, on page 19) to aid the user to navigate

the Axis product. Each OSDI zone is set up with coordinates and a descriptive name.

OSDI zones are set up under PTZ > OSDI Zones. The Axis product uses the coordinates of the center of the view to set the lower left and upper right zone areas. First navigate to where you would like the lowermost left point of the OSDI zone to be located.

Click Get to set the coordinates. Proceed to where the upper right point of zone should be located and click Get. Give the zone a descriptive name and click OK.

To include the name of the OSDI zone in the overlay text, go to Video & Audio < Video Stream < Overlay Settings. Check the

Include text box and enter the modifier #L in the field. For more information about modifiers, see File Naming & Date/Time Formats in the online help .

Advanced

Limits

Define the pan, tilt, zoom and focus limits for the Axis product. Movements to the left and right, up and down, can be restricted to narrow the area under surveillance.

Configure the near focus limit to avoid focusing on objects too close to the camera lens.

Move speed sets the speed of the camera’s pan and tilt movements. The default setting is maximum speed.

26

AXIS P5534 PTZ Dome Network Camera

PTZ (Pan Tilt Zoom)

When using a joystick (or emulating one with the mouse) the

Enable proportional speed setting can be used to reduce the maximum pan/tilt movement speed, i.e. the speed the camera view moves at when the joystick is pushed all the way out in any direction. This is useful then the view is zoomed in on an object.

When Enable Auto-flip is selected, the Axis product will simulate continuous pan movement in the same direction, i.e. the camera will pan the full 360 degrees, even though there is a mechanical stop at ±180 degrees.

When Enable movement prediction is selected, the Axis product will attempt to predict the new position in the pan movement, after compensating for the slight delay while the camera changes direction after an auto-flip. This is useful for tracking moving objects or persons when using the joystick or emulated joystick mode.

See the online help for more information.

Controls

Panel Shortcut Command Buttons can be configured to provide direct access to commands issued via the VAPIX® Application

Programming Interface. The buttons will be displayed in the PTZ control panel, which is available in the Live View page through the

Ctrl panel button, see page 10.

Deselect the options under Enable/Disable controls to disable the pan, tilt, zoom, focus and iris controls.

Note

Disabling PTZ controls will not affect preset positions. For example, if the tilt control is disabled, the product can still move to preset positions that require a tilt movement.

Control Queue

The administrator can set up a queue for PTZ controllers from PTZ > Control Queue. Once set up, the PTZ Control Queue buttons appear in the Live View page offering one viewer exclusive control for a limited period of time. Other users will be placed in queue.

A user who belongs to a group (see Users, on page 37) with a higher PTZ priority can go before other users in the queue and

take control of the product. The order of priority is as follows:

1.

Administrator — An administrator takes over PTZ control regardless of who is first in queue. The administrator will be removed from the queue 60 seconds after the last PTZ control command.

2.

Event — The Axis product can be configured to go to a preset position when triggered by an alarm (see Events, on page 31).

The event will immediately be placed first in the queue except when an administrator is in control.

3.

Operator — Same as administrator but with lower priority

4.

Guard Tour — A guard tour (see page 26) has PTZ control for an indefinite period of time. It may be overridden by an

operator, event or administrator. The guard tour will resume when higher priority groups leave the queue.

5.

Viewer — Multiple viewers must wait for their turn. The viewer has 60 seconds PTZ control before control is passed on to the next viewer in queue.

Note

• The administrator can enable and disable PTZ controls for selected users.

• To identify different users in the viewer group, cookies must be enabled on the client.

27

AXIS P5534 PTZ Dome Network Camera

Detectors

Detectors

Motion Detection

Motion detection is used to generate an alarm whenever movement occurs (or stops) in the view. Up to 10 Include and Exclude windows can be configured:

Include windows — target specific areas within the whole video image

Exclude windows — define areas within an Include window that should be ignored (areas outside Include windows are automatically ignored)

Once configured, motion detection windows appear in the list of Detectors in Action rule setup. See Setting Up an Action Rule, on

page 32.

Note

Using the motion detection feature may decrease the product’s overall performance.

Set up motion detection

To set up a motion detection Include Window, follow these instructions:

1. Go to

Detectors > Motion Detection.

2. Select the

Configure Included Windows option and click New. Select the new window in the list of windows and enter a descriptive name.

3. Adjust the size (drag the bottom right-hand corner) and the position (click on the text at the top and drag to the desired position) of the active window (window with red frame).

4. Adjust the

Object Size, History and Sensitivity profile sliders (see Motion detection parameters for details). Any detected

motion within an active window is indicated by red peaks in the Activity window.

5. Click

Save.

To exclude parts of the include window, select the

Configure Excluded Windows and position the exclude window within the include window.

To delete an include or exclude window, select the window in the list of windows and click

Del.

Motion detection parameters

The parameters controlling motion detection are described in the table below:

28

AXIS P5534 PTZ Dome Network Camera

Detectors

Parameter

Description

High level (100%)

Medium level (50%)

Low level (0%)

Object Size

Object size relative to window size.

Only very large objects trigger motion detection.

History

Object memory length.

An object that appears in the window triggers motion detection for a long time before it is considered as non-moving.

Sensitivity

Difference in luminance between background and object.

Ordinary colored objects on ordinary backgrounds trigger motion detection.

Even very small objects trigger motion detection.

5–15%

15%

An object that appears in the window triggers motion detection only for a very short time before it is considered as non-moving.

60–90%

90%

A large difference in luminance is required to trigger motion detection.

Only very bright objects on a dark background trigger motion detection.

75–95%

90%

Recommended values

Default values

Tips:

• To trigger on small objects or movements, use several small motion detection windows rather than one large window and select a low object size.

• To avoid triggering on small objects, select a high object size.

• If no objects should appear in the Include Window, select a high history level. This will cause motion detection to trigger as long as the object is present in the window.

• To only detect flashing light, select a low sensitivity. In other cases high sensitivity is recommended.

Audio detection

The Axis product can be configured to generate an alarm when audio rises above or falls below the threshold value. The threshold value can be set in the range 0–100 where 0 is the most sensitive and 100 the least sensitive.

1. Go to

Detectors > Audio Detection.

2. Set the audio alarm level and click

Save.

3. Go to

Events > Action Rules and set up an action rule, see Setting Up an Action Rule, on page 32.

Note

A multi-connector cable (available from Axis) is required when connecting external audio equipment to the Axis product.

See Multi-Connector Cable (sold separately), on page 47.

Detected audio is indicated by colored peaks in the

Activity indicator. An event is triggered when detected audio rises above or falls below the threshold value, which is represented by the bar.

29

AXIS P5534 PTZ Dome Network Camera

Applications

Applications

Third party applications can be uploaded to and installed on the Axis product. For information about available applications, downloads, trials and licenses, go to www.axis.com/applications

To upload an application, go to Applications > Overview, click Browse to locate the file and then click Upload Package. Click on the uploaded application’s name to open the menu options Settings, License and About. For configuration instructions, please refer to the documentation provided with the application.

Most applications need a license to run. To install the license, select the License menu option. If the product is connected to the Internet, Automatic Installation appears in the web page. If the product is not connected to the Internet, go to www.axis.com/applications to acquire a License key. You will need a license code and the product’s serial number (found on the label and under System Options > Support > System Overview) to receive a license key.

Installed Applications lists installed applications with information about the version and the vendor, the status of the application

(running or not running), and information about the license.

Use the

Start and Stop buttons to start and stop the application.

To generate a log file for the application, select the application and click

Log.

Note

It is recommended to run one application at a time. Avoid running applications when motion detection is active.

30

AXIS P5534 PTZ Dome Network Camera

Events

Events

The Axis product can be configured to perform actions when different events occur, for example, start a recording when motion is detected. The set of conditions that defines how and when the action is triggered is called an

Action Rule.

Available Action Rule triggers and conditions include:

Applications — use installed applications to trigger the rule, see Applications, on page 30.

Detectors

-

Audio Detection — trigger the rule when audio is detected, see Audio detection, on page 29.

-

Motion Detection — trigger the rule when motion is detected, see Motion Detection, on page 28.

Hardware

Fan — trigger the rule if the fan is malfunctioning. This can for example be used to send maintenance notifications.

-

Network — trigger the rule if network connection is lost or restored. This can for example be used to start recording to the SD card.

-

Temperature — trigger the rule if the temperature falls outside or inside the operating range of the product. This can for example be used to send maintenance notifications.

Input Signal

-

Digital Input Port — trigger the rule when an I/O port receives a signal from a connected device, see I/O

Ports, on page 44.

-

Manual Trigger — trigger the rule using the Manual Trigger button in the Live View page, see Controls on

the Live View page, on page 9 . This can for example be used to validate actions during product installation

and configuration.

PTZ

-

Moving — trigger the rule when the camera view moves due to a PTZ operation. This can for example be used as an additional condition to prevent an action rule triggered by motion detection to record video while the camera view moves due to a PTZ operation.

-

Preset Reached — trigger the rule when the camera stops at a preset position. This can be for example be used with the Send Images action to upload images from the preset position.

Storage

Available — trigger the rule when the storage device is unmounted or removed. This can for example be used to send maintenance notifications.

Full — trigger the rule when the storage device is full. Under normal operation, the oldest recordings will be overwritten to prevent the storage device from becoming full.

-

Locked — trigger the rule if the storage device is locked (write protected).

System

-

System Initializing — trigger the rule when the product is being started. This can for example be used to send a notification when the product restarts.

Time

-

Recurrence — trigger the rule periodically, see Recurrences, on page 34. This can for example be used to upload

an image every 5 minutes.

31

AXIS P5534 PTZ Dome Network Camera

Events

-

Use Schedule — trigger the rule according to the selected schedule, see Schedules, on page 33.

Available actions include:

Day/Night Vision Mode — set day mode (IR cut filter on) or night mode (IR cut filter off).

Output Port — activate an I/O port to control an external device.

Play Audio Clip — see Audio Clips, on page 21.

PTZ Control

Preset Position — go to a preset position.

-

Guard Tour — start a guard tour, see Guard Tour, on page 26.

Record Video — record video to a selected storage.

Send Images — send images to a recipient.

Send Notifications — send a notification message to a recipient.

Convert Event Types to Action Rules

If the Axis product is upgraded to firmware version 5.40 or later, it is recommended to convert Event Types to Action Rules. The legacy user

Event Types in the camera will continue to work but will not be visible in the user interface of the camera. The Event

Types need to be converted to Action rules to become visible in the user interface.

To convert Event Types to Action Rules go to Events > Action Rules and click Convert.

Caution

This is not recommended when using a VMS based on the old Event Management System.

Setting Up an Action Rule

An action rule defines the conditions that must be met for the product to perform an action, for example record video or send email notifications. If multiple conditions are defined, all must be met to trigger the action.

The following example describes how to set up an action rule to record video to a network share if there is movement in the camera’s field of view.

Set up motion detection and add a network share:

1. Go to

Detectors > Motion Detection and configure a motion detection window, see page 28

2. Go to

System Options > Storage and set up the network share, see page 44.

Set up the action rule:

1. Go to

Events > Action Rules and click Add.

2. Select Enable rule and enter a descriptive name for the rule.

3. Select Detectors from the Trigger drop-down list.

4. Select Motion Detection from the drop-down list. Select the motion detection window to use.

5. Optionally, select a

Schedule and Additional conditions, see below.

6. Under

Actions, select Record Video from the Type drop-down list.

7. Select a

Stream profile and configure the Duration settings as described below.

32

AXIS P5534 PTZ Dome Network Camera

Events

8. Select Network Share from the

Storage drop-down list.

To add additional criteria, select the Additional conditions option and add additional triggers. To prevent an action from being triggered repeatedly, a Wait at least time can be set. Enter the time in hours, minutes and seconds, during which the trigger should be ignored before the action rule can be activated again.

The recording Duration of some actions can be set to include time immediately before and after the event. Select Pre-trigger time and/or Post-trigger time and enter the number of seconds. When While the rule is active is enabled and the action is triggered again during the post-trigger time, the recording time will be extended with another post-trigger time period.

For more information, see the online help .

Recipients

Recipients receive media files and notification messages. The following recipients are available:

Recipient

Email

FTP

HTTP

Network Share

TCP

Use with action

Send Images

Send Notification

Send Images

Send Images

Send Notification

Send Images

Send Notification

To add a recipient:

1. Go to

Events > Recipients and click Add.

2. Enter a descriptive name

3. Select a recipient Type.

4. Enter the information needed for the recipient type.

5. Click Test to test the connection to the recipient.

6. Click

OK.

Schedules

Schedules can be used as action rule triggers or as additional conditions, for example to record video if motion is detected outside office hours. Use one of the predefined schedules or create a new schedule as described below.

To create a new schedule:

1. Go to

Events > Schedules and click Add.

2. Enter a descriptive name and the information needed for a daily, weekly, monthly or yearly schedule.

3. Click

OK.

To use the schedule in an Action Rule, select the schedule from the Schedule drop-down list in the Action Rule Setup page.

33

AXIS P5534 PTZ Dome Network Camera

Events

Recurrences

Recurrences are used to trigger Action Rules repeatedly, for example every 5 minutes or every hour.

To set up a recurrence:

1. Go to

Events > Recurrences and click Add.

2. Enter a descriptive name and recurrence pattern.

3. Click OK.

To use the recurrence in an Action Rule, first select Time from the Trigger drop-down list in the Action Rule Setup page and then select the recurrence from the second drop-down list.

To modify or remove recurrences, select the recurrence in the

Recurrences List and click Modify or Remove.

34

AXIS P5534 PTZ Dome Network Camera

Recordings

Recordings

The Axis product can be configured to record video continuously or according to an action rule:

• To start a continuous recording, see page 35.

• To set up action rules, see page 32.

• To access recordings, see Recording List, on page 35.

• To configure camera controlled storage, see Storage, on page 43.

Recording List

Recorded videos are listed on the

Recordings > List page. The list shows each recording’s start date and time, duration and the event that triggered the recording.

To play or download a recording, follow these steps:

3. Select the recording.

4. Click

Play to play the recording, or click Download to download the recording.

Multiple recordings can be downloaded at the same time. Select the recordings and click Download. The downloaded file is a zip file containing a minimum of three files, of which the Matroska (mkv) files are the actual recordings. The recordings are time-stamped with the date and time they were downloaded (that is, not the date the recordings were made).

Note

1. Go to Recordings > List.

2. Use the filter to narrow the list of recordings. Enter the desired filter criteria and click

Filter. Some filters may take a long time to complete.

To play recordings in Windows Media Player, AXIS Matroska File Splitter must be installed. AXIS Matroska File Splitter can be downloaded from www.axis.com/techsup/software

For detailed recording and video information, select a recording and click

Properties.

To remove a recording, select the recording and click

Remove.

Continuous recording

The Axis product can be configured to continuously save video to a storage device. See Storage, on page 43 for more information

about storage devices. To prevent the disk from becoming full, it is recommended to configure the disk to automatically remove old recordings see .

To start a continuous recording, follow these steps:

1. Go to Recordings > Continuous.

2. Select Enabled.

3. Select type of storage device from the

Disk list.

4. Select a

Stream profile to use for continuous recordings.

5. Click

Save to save and start the recording.

35

AXIS P5534 PTZ Dome Network Camera

Recordings

Note

If a new stream profile is selected while a recording is ongoing, the recording will be stopped and saved in the recording list and a new recording with the new stream profile will start. All previous continuous recordings will remain in the recording list until they are removed manually or through automatic removal of old recordings.

36

AXIS P5534 PTZ Dome Network Camera

System Options

System Options

Security

Users

User access control is enabled by default and can be configured under System Options > Security > Users. An administrator can set up other users by giving them user names and passwords. It is also possible to allow anonymous viewer login, which means that anybody may access the Live View page.

The user list displays authorized users and user groups (access levels):

Viewer - Access to the Live View page

Operator - Access to the Live View page and to all settings except System Options

Administrator - Unrestricted access to all settings; can add, modify and remove other users.

Under

HTTP/RTSP Password Settings, select the type of password to allow. You may need to allow unencrypted passwords if there are viewing clients that do not support encryption, or if you upgraded the firmware and existing clients support encryption but need to log in again and be configured to use this functionality.

Under

User Settings, select the Enable anonymous viewer login option to allow anonymous users access to the Live View page.

Select the Enable anonymous PTZ control login to allow anonymous users access to the PTZ controls.

Deselect the Enable Basic Setup option to hide the Basic Setup menu. Basic Setup provides quick access to settings that should be made before using the Axis product.

ONVIF

ONVIF (Open Network Video Interface Forum) is a global interface standard that makes it easier for end users, integrators, consultants, and manufacturers to take advantage of the possibilities offered by network video technology. ONVIF enables interoperablity between different vendor products, increased flexibility, reduced cost and future-proof systems.

By creating a user you automatically enable ONVIF communication. Use the user name and password with all ONVIF communication with the product. For more information see www.onvif.org

IP Address Filter

IP address filtering is enabled on the System Options > Security > IP Address Filter page. Once enabled, the listed IP address are allowed or denied access to the Axis product. Select

Allow or Deny from the list and click Apply to enable IP address filtering.

The administrator can add up to 256 IP address entries to the list (a single entry can contain multiple IP addresses).

HTTPS

The Axis product supports encrypted browsing using HTTPS. This is configured on the System Options > Security > HTTPS page.

A self-signed certificate can be used until a Certificate Authority-issued certificate has been obtained. Click Create self-signed

certificate to install a self-signed certificate. Although self-signed certificates are free and offer some protection, true security is only implemented after the installation of a signed certificate issued by a Certificate Authority.

To obtain a signed certificate from an issuing Certificate Authority, click

Create Certificate Request. When the signed certificate is returned, click

Install signed certificate to import the certificate. The properties of any certificate request currently resident in the product or installed can be viewed by clicking

Properties.

To enable HTTPS in the Axis product, the

HTTPS Connection Policy must be set for each user group.

For more information, see the online help .

37

AXIS P5534 PTZ Dome Network Camera

System Options

IEEE 802.1X

IEEE 802.1X is a standard for port-based Network Admission Control providing secure authentication of wired and wireless network devices. IEEE 802.1X is based on EAP (Extensible Authentication Protocol).

To access a network protected by IEEE 802.1X, devices must authenticate themselves. The authentication is performed by a third-party entity called an authentication server, typically a RADIUS server, examples of which are FreeRADIUS and Microsoft

Internet Authentication Service.

In Axis' implementation, the network device and the authentication server authenticate themselves with the help of digital certificates using EAP-TLS (Extensible Authentication Protocol - Transport Layer Security). The certificates are provided by an

Certification Authority (CA). You need:

• a CA certificate to validate the identity of the authentication server

• a CA-signed client certificate and a private key to authenticate the network device.

To allow the network device to access a network protected by IEEE 802.1X:

1. Obtain a CA certificate, a client certificate and a client private key (contact your network administrator).

2. Go to Setup > System Options > Security > IEEE 802.1X and upload the CA certificate, the client certificate and the client private key.

3. Under

Settings, select the EAPOL version, provide your EAP identity and private key password.

4. Check the box to enable IEEE 802.1X and click

Save.

Certificates

CA Certificate

Client certificate

Client private key

The CA certificate is used to validate the identity of the authentication server. Enter the path to the certificate directly, or locate the file using the Browse button. Then click Upload. To remove a certificate, click Remove.

The client certificate and private key are used to authenticate the network device. They can be uploaded as separate files or in one combined file (e.g. a PFX file or a PEM file). Use the

Client

private key field if uploading one combined file. For each file, enter the path to the file, or locate the file using the

Browse button. Then click Upload. To remove a file, click Remove.

Settings

EAPOL version

EAP identity

Private key password

Enable IEEE 802.1X

Select the EAPOL version (1 or 2) as used in your network switch.

Enter the user identity (maximum 16 characters) associated with your certificate.

Enter the password (maximum 16 characters) for the private key.

Check the box to enable the IEEE 802.1X protocol.

Audio Support

Select

Enable audio support to allow clients to retrieve audio streams from the Axis product. For information on how to configure

audio settings, see Audio Settings, on page 19.

Note

Deselecting this option will disable audio globally in the Axis product, for configured events and profiles with audio as well.

Date & Time

The Axis product’s date and time settings are configured under

System Options > Date & Time.

Current Server Time displays the current date and time (24h clock). The time can be displayed in 12h clock in the text overlay (see below).

38

AXIS P5534 PTZ Dome Network Camera

System Options

To change the date and time settings, select the preferred

Time mode under New Server Time:

Synchronize with computer time sets date and time according to the computer’s clock. With this option, date and time are set once and will not be updated automatically.

Synchronize with NTP Server obtains date and time from an NTP server. With this option, date and time settings are

updated continuously. For information on NTP settings, see NTP Configuration, on page 40.

If using a host name for the NTP server, a DNS server must be configured. See DNS Configuration, on page 40.

Set manually allows you to manually set date and time.

If using an NTP server, select your

Time zone from the drop-down list. If required, check Automatically adjust for daylight saving

time changes.

The Date & Time Format Used in Images is the date and time format displayed as a text overlay in the video stream. Use the predefined formats or see File Naming & Date/Time Formats in the online help for information on how to create custom date and time formats. To include date and time in the overlay text, go to Video & Audio and select Include date and Include time.

Network

Basic TCP/IP Settings

The Axis product supports IP version 4 and IP version 6. Both versions can be enabled simultaneously, and at least one version must always be enabled.

IPv4 Address Configuration

By default, the Axis product is set to use IPv4 (IP version 4) and to obtain the IP address automatically via DHCP. The IPv4 settings are configured under System Options > Network > TCP/IP > Basic.

DHCP (Dynamic Host Configuration Protocol) allows network administrators to centrally manage and automate the assignment of

IP addresses. DHCP should only be enabled if using dynamic IP address notification, or if the DHCP can update a DNS server. It is then possible to access the Axis product by name (host name).

If DHCP is enabled and the product cannot be accessed, run AXIS IP Utility to search the network for connected Axis products, or reset

the product to the factory default settings (see page 46) and then perform the installation again.

To use a static IP address, check

Use the following IP address and specify the IP address, subnet mask and default router.

IPv6 Address Configuration

If IPv6 (IP version 6) is enabled, the Axis product will receive an IP address according to the configuration in the network router.

To enable IPv6, go to System Options > Network > TCP/IP > Basic. Other settings for IPv6 should be configured in the network router.

ARP/Ping

The IP address can be set using ARP and Ping. For instructions, see the product’s Installation Guide.

ARP/Ping is enabled by default. To disable, uncheck the box under System Options > Network > TCP/IP > Basic.

The ARP/Ping service is automatically disabled two minutes after the product is started, or as soon as an IP address is set. To reset the

IP address, the product must be restarted to activate ARP/Ping for an additional two minutes.

Pinging the product is still possible when this service is disabled.

39

AXIS P5534 PTZ Dome Network Camera

System Options

AXIS Video Hosting System (AVHS)

AVHS used in conjunction with an AVHS service, provides easy and secure Internet access to live and recorded video accessible from any location. For more information and help to find a local AVHS Service Provider go to www.axis.com/hosting

AVHS is enabled by default. The settings are configured under System Options > Network > TCP IP > Basic.

One-click enabled - Press the product’s control button (see Hardware overview, on page 5 ) to connect to an AVHS service over the

Internet. Once registered, Always will be enabled and the Axis product stays connected to the AVHS service. If the product is not registered within 24 hours from when the button is pressed, the product will disconnect from the AVHS service.

Always - The Axis product will constantly attempt to connect to the AVHS service over the Internet. Once registered the product will stay connected to the service. This option can be used when the product is already installed and it is not convenient to use the one-click installation.

AXIS Internet Dynamic DNS Service

AXIS Internet Dynamic DNS Service assigns a host name for easy access to the product. For more information, see www.axiscam.net

To register the Axis product with AXIS Internet Dynamic DNS Service, go to

System Options > Network > TCP/IP > Basic. Under

Services, click the AXIS Internet Dynamic DNS Service Settings button (requires access to the Internet). The domain name currently registered at AXIS Internet Dynamic DNS service for the product can at any time be removed.

Advanced TCP/IP Settings

DNS Configuration

DNS (Domain Name Service) provides the translation of host names to IP addresses. The DNS settings are configured under

System

Options > Network > TCP/IP > Advanced.

Select Obtain DNS server address via DHCP to use the DNS settings provided by the DHCP server.

To make manual settings, select Use the following DNS server address and specify the following:

Domain name - Enter the domain(s) to search for the host name used by the Axis product. Multiple domains can be separated by semicolons. The host name is always the first part of a fully qualified domain name, for example, myserver is the host name in the fully qualified domain name myserver.mycompany.com where mycompany.com is the domain name.

Primary/Secondary DNS server - Enter the IP addresses of the primary and secondary DNS servers. The secondary DNS server is optional and will be used if the primary is unavailable.

NTP Configuration

NTP (Network Time Protocol) is used to synchronize the clock times of devices in a network. The NTP settings are configured under

System Options > Network > TCP/IP > Advanced.

Select

Obtain NTP server address via DHCP to use the NTP settings provided by the DHCP server.

To make manual settings, select Use the following NTP server address and enter the host name or IP address of the NTP server.

Host Name Configuration

The Axis product can be accessed using a host name instead of an IP address. The host name is usually the same as the assigned DNS name. The host name is configured under System Options > Network > TCP/IP > Advanced.

Select Obtain host name via IPv4 DHCP to use host name provided by the DHCP server running on IPv4.

Select Use the host name to set the host name manually.

Select

Enable dynamic DNS updates to dynamically update local DNS servers whenever the Axis product’s IP address changes.

For more information, see the online help .

40

AXIS P5534 PTZ Dome Network Camera

System Options

Link-Local IPv4 Address

Link-Local Address is enabled by default and assigns the Axis product an additional IP address which can be used to access the product from other hosts on the same segment on the local network. The product can have a Link-Local IP and a static or DHCP-supplied IP address at the same time.

This function can be disabled under System Options > Network > TCP/IP > Advanced.

HTTP

The HTTP port used by the Axis product can be changed under System Options > Network > TCP/IP > Advanced. In addition to the default setting, which is 80, any port in the range 1024–65535 can be used.

HTTPS

The HTTPS port used by the Axis product can be changed under System Options > Network > TCP/IP > Advanced. In addition to the default setting, which is 443, any port in the range 1024–65535 can be used.

To enable HTTPS, go to

System Options > Security > HTTPS. For more information, see page 37.

NAT traversal (port mapping) for IPv4

A network router allows devices on a private network (LAN) to share a single connection to the Internet. This is done by forwarding network traffic from the private network to the “outside”, that is, the Internet. Security on the private network (LAN) is increased since most routers are pre-configured to stop attempts to access the private network (LAN) from the public network (Internet).

Use

NAT traversal when the Axis product is located on an intranet (LAN) and you wish to make it available from the other

(WAN) side of a NAT router. With NAT traversal properly configured, all HTTP traffic to an external HTTP port in the NAT router is forwarded to the product.

NAT traversal is configured under

System Options > Network > TCP/IP > Advanced.

Note

• For NAT traversal to work, this must be supported by the router. The router must also support UPnP

TM

.

• The router has many different names: “NAT router”, “Network router”, “Internet Gateway”, ”Broadband router”, “Broadband sharing device” or “Home firewall” but the essential purpose of the device is the same.

Enable/Disable - When enabled, the Axis product attempts to configure port mapping in a NAT router on your network, using UPnP TM

.

Note that UPnP

TM must be enabled in the product (see

System Options > Network > UPnP).

Use manually selected NAT router - Select this option to manually select a NAT router and enter the IP address for the router in the field. If no router is specified, the product automatically searches for NAT routers on your network. If more than one router is found, the default router is selected.

Alternative HTTP port - Select this option to manually define an external HTTP port. Enter the port number in the field. If no port is entered here, a port number is automatically selected when NAT traversal is enabled.

Note

• An alternative HTTP port can be used or be active even if NAT traversal is disabled. This is useful if your NAT router does not support UPnP and you need to manually configure port forwarding in the NAT router.

• If you attempt to manually enter a port that is already in use, another available port is automatically selected.

• When the port is selected automatically it is displayed in this field. To change this, enter a new port number and click

Save.

FTP

The FTP server running in the Axis product enables upload of new firmware, user applications, etc. The FTP server can be disabled under

System Options > Network > TCP/IP > Advanced.

41

AXIS P5534 PTZ Dome Network Camera

System Options

Note

This FTP server has nothing to do with the product’s ability to transfer images via FTP to other locations and servers.

RTSP

The RTSP server running in the Axis product allows a connecting client to start an H.264 stream. The RTSP port number can be changed under

System Options > Network > TCP/IP > Advanced. The default port is 554.

Note

H.264 video streams will not be available if the RTSP server is disabled.

SOCKS

SOCKS is a networking proxy protocol. The Axis product can be configured to use a SOCKS server to reach networks on the other side of a firewall or proxy server. This functionality is useful if the Axis product is located on a local network behind a firewall, and notifications, uploads, alarms, etc need to be send to a destination outside the local network (for example the Internet).

SOCKS is configured under System Options > Network > SOCKS. For more information, see the online help .

QoS (Quality of Service)

QoS (Quality of Service) guarantees a certain level of a specified resource to selected traffic on a network. A QoS-aware network prioritizes network traffic and provides a greater network reliability by controlling the amount of bandwidth an application may use.

The QoS settings are configured under System Options > Network > QoS. Using DSCP (Differentiated Services Codepoint) values, the

Axis product can mark the following types of traffic: live video, live audio, event/alarm traffic and management traffic.

Note

Live audio DSCP will be equal to live video DSCP if H.264 over RTSP is used.

SMTP (email)

To send email messages from the Axis product via SMTP (Simple Mail Transfer Protocol), an SMTP mail server must be set up. This is done under System Options > Network > SMTP (email).

Enter the host names or IP addresses and port numbers for the primary and secondary mail servers in the fields provided. A

From

email address is also required. If the mail server requires authentication, check Use authentication to log in to this server and enter the necessary information.

SNMP

The Simple Network Management Protocol (SNMP) allows remote management of network devices. An SNMP community is the group of devices and management station running SNMP. Community names are used to identify groups.

The Axis product can be configured to support SNMP on the System Options > Network > SNMP page.

Depending on the level of security required, select the version on SNMP to use.

SNMP v1/v2 provides the lowest level of security. The community name can be specified as a password for read or read/write access to all supported SNMP devices. The default password for the

Read community is public and the default password for the

Write community is write.

Note

If HTTPS is enabled, SNMP v1 and SNMP v2c should be disabled.

Traps for SNMP v1/v2 are used by the Axis product to send messages to a management system on important events and status changes. Check Enable traps and enter the IP address where the trap message should be sent and the Trap community that should receive the message.

42

AXIS P5534 PTZ Dome Network Camera

System Options

The following traps are available:

• Cold start

• Warm start

• Link up

• Authentication failed

SNMP v3 provides encryption and secure passwords. To use traps with SNMP v3, an SNMP v3 management application is required.

To use SNMP v3, HTTPS must be enabled, see HTTPS, on page 37. To enable SNMP v3, check the box and provide the initial user

password.

Note

The initial password can only be set once. If the password is lost, the Axis product must be reset to factory default, see

Reset to factory default settings, on page 46.

UPnP

TM

The Axis product includes support for UPnP TM . UPnP TM is enabled by default and the product is automatically detected by operating systems and clients that support this protocol.

UPnP

TM can be disabled under

System Options > Network > UPnP

TM

.

RTP/H.264

The RTP port range and multicast settings are configured under

System Options > Network > RTP.

The RTP port range defines the range of ports from which the video/audio ports are automatically selected. For multicast streams, only certain IP addresses and port numbers should be used.

Select Always Multicast Video and/or Always Multicast Audio to start multicast streaming without opening an RTSP session.

Bonjour

The Axis product includes support for Bonjour. Bonjour is enabled by default and the product is automatically detected by operating systems and clients that support this protocol.

Bonjour can be disabled under

System Options > Network > Bonjour.

Storage

SD card

The SD/SDHC memory card (not included) is managed on the System Options > Storage page. Click SD card to open Storage

Management.

Mounting is done automatically when the card is inserted or when the product boots. SD cards are normally preformatted when purchased, but if needed, click Format to format the card.

Format an SD card so that it can be written to one of two available options — VFAT and ext4. During the formatting any previous data stored on the disk will be lost. The recommended format is ext4, due to its resilience against data loss if the card is ejected or if there is abrupt power loss. A third-party ext4 driver or application is also needed to access the file system from Windows.

Note that most SD cards are pre-formatted with vFAT when purchased. The

Check Disk option is used to check for errors on the SD card and only works for the file system ext4. The

Repair option repairs the SD card of errors in the file system ext4. For vFAT file system use a card reader or PC to perform card maintenance.

Note

To prevent corruption of recordings, the SD card should always be unmounted before removal.

43

AXIS P5534 PTZ Dome Network Camera

System Options

If the card’s status shows as failed, click

Check disk to see if the problem can be found and then try Repair.

To avoid filling the card, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings

older than and select the number of days or weeks.

To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.

For more information, see the online help .

Network Share

Network share allows you to add network storage such as a NAS (Network Attached Storage) or any server that uses CIFS (Common

Internet File System) and use them for storage of recordings.

To add a network share:

1. Go to System Options > Storage.

2. Click

Network Share.

3. Enter the IP address, DNS or Bonjour name to the host server in the

Host field.

4. Enter the name of the share in the

Share field.

5. If required, select The share requires login and enter the user name and password.

6. Click Connect.

To clear all recordings and data from the Axis product’s folder on the designated share, click

Clear under Storage Tools.

To avoid filling the share, it is recommended to remove recordings continuously. Under

Recording Settings, select Remove recordings

older than and select the number of days or weeks.

To stop writing to the share and protect recordings from being removed, select

Lock under Recording Settings.

Ports & Devices

I/O Ports

The Axis product provides four configurable input and output ports for connection of external devices. A multi-connector cable

(available from Axis) is required when connecting external devices, see Multi-Connector Cable (sold separately), on page 47.

The I/O ports are configured under System Options > Ports & Devices > I/O Ports. Select the port direction (Input or Output). The ports can be given descriptive names and their Normal states can be configured as Open circuit or Grounded circuit.

Port Status

The list on the

System Options > Ports & Devices > Port Status page shows the status of the product’s input and output ports.

Note

A multi-connector cable (available from Axis) is required when connecting I/O devices to the Axis product. See

Multi-Connector Cable (sold separately), on page 47.

Maintenance

The Axis product provides several maintenance functions. These are available under

System Options > Maintenance.

Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current settings.

44

AXIS P5534 PTZ Dome Network Camera

System Options

Click

Restore to reset most settings to the factory default values. The following settings are not affected:

• the boot protocol (DHCP or static)

• the static IP address

• the default router

• the subnet mask

• the system time

• the IEEE 802.1X settings

Click Default to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The

Axis product can also be reset to factory default using the control button, see Reset to factory default settings, on page 46.

To test the product’s PTZ mechanics, click

Test under PTZ Status.

For information about firmware upgrade, see Upgrading the firmware, on page 49.

Support

Support Overview

The System Options > Support > Support Overview page provides information on troubleshooting and contact information, should you require technical assistance.

See also Troubleshooting, on page 49.

System Overview

To get an overview of the Axis product’s status and settings, go to

System Options > Support > System Overview. Information that can be found here includes firmware version, IP address, network and security settings, event settings, image settings and recent log items. Many of the captions are links to the proper Setup page.

Logs & Reports

The System Options > Support > Logs & Reports page generates logs and reports useful for system analysis and troubleshooting. If contacting Axis Support, please provide a valid Server Report with your query.

System Log - Provides information about system events.

Access Log - Lists all failed attempts to access the product. The Access Log can also be configured to list all connections to the product (see below).

Server Report - Provides information about the product status in a pop-up window. The Access Log is automatically included in the Server Report.

You can view or download the server report. Downloading the server report creates a .zip file that contains a complete server report text file in UTF–8 format. Select the

Include snapshot with default image settings option to include a snapshot of the product’s

Live View that also shows the settings specified under

Video Stream>Image>Image Appearance. The server report .zip file should always be included when contacting support.

Parameter List - Shows the product's parameters and their current settings. This may prove useful when troubleshooting or when contacting Axis Support.

Connection List - Lists all clients that are currently accessing media streams.

Crash Report - Generates an archive with debugging information. The report takes several minutes to generate.

45

AXIS P5534 PTZ Dome Network Camera

System Options

The log levels for the System Log and the Access Log are set under

System Options > Support > Logs & Reports > Configuration.

The Access Log can be configured to list all connections to the product (select Critical, Warnings & Info). If required, a different log level can be used when sending emails.

Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

Caution

Improper use may cause unexpected behavior and loss of contact with the Axis product.

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to

System Options > Advanced > Scripting. It is recommended to create a backup file before

customizing the scripts. If a script causes problems, reset the product to its factory default settings, see page 46.

For more information, see www.axis.com/developer

File Upload

Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page. Help is available from the standard help pages.

To open Plain Config, go to System Options > Advanced > Plain Config.

Reset to factory default settings

This will reset all parameters, including the IP address, to the factory default settings:

1. Press and hold the Control button and the Restart button at the same time (see Hardware overview, on page 5 ).

2. Release the Restart button but continue to hold down the Control button for about 15 seconds until the Status indicator flashes amber.

3. Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The product has been reset to the factory default settings. The default IP address is 192.168.0.90

4. Re-assign the IP address.

It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

46

AXIS P5534 PTZ Dome Network Camera

Multi-Connector Cable (sold separately)

Multi-Connector Cable (sold separately)

When connecting external equipment to the Axis product, a multi-connector cable (available from Axis) is required in order to maintain the product’s IP rating. The multi-connector cable can be purchased from your Axis reseller.

Connect the multi-connector cable to the product’s multi-connector (see page 5 ). The cable provides the following connectors:

Note

See page 54 for technical specifications.

Power connector - 3-pin terminal block used for power input. See image below.

Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).

Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio out.

I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications.

In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:

• Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the

VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under

System Options > Port & Devices > Port Status) if the alarm device is activated.

• Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under

System Options > Port & Devices > Port Status).

Function

GND

3.3 V DC Power

Configurable

(Input or Output)

Pin

1

2

3–6

Notes

Ground

Can be used to power auxiliary equipment.

Note: This pin can only be used as power out.

Digital input — Connect to GND to activate, or leave floating

(unconnected) to deactivate.

Digital output — Internal connection to ground when activated, floating (unconnected) when deactivated. If used with an external relay, a diode must be connected in parallel with the load, for protection against voltage transients.

Specifications

Max load = 250 mA

0 to +40 V DC

Max load =100 mA

Max voltage = +40 V DC

47

AXIS P5534 PTZ Dome Network Camera

Multi-Connector Cable (sold separately)

Connection diagram:

3.3 V max 250 mA

1

2

A

B

A

I/O configured as input

B

I/O configured as output

I/O connector

DC power input AC power input

48

AXIS P5534 PTZ Dome Network Camera

Troubleshooting

Troubleshooting

Checking the firmware

Firmware is software that determines the functionality of network devices. One of your first actions when troubleshooting a problem should be to check the current firmware version. The latest version may contain a correction that fixes your particular problem. The current firmware version in the Axis product is displayed in the page

Setup > Basic Setup and in Setup > About.

Upgrading the firmware

When you upgrade the product with the latest firmware from Axis website, the product receives the latest functionality available.

Always read the upgrade instructions and release notes available with each new release, before upgrading the firmware.

To upgrade, follow these instructions:

1. Save the firmware file to your computer. The latest version of the firmware is available free of charge from Axis website at www.axis.com/techsup

2. Go to Setup > System Options > Maintenance in the products web pages.

3. Under Upgrade Server, click Browse and locate the file on your computer. Click Upgrade.

After starting the upgrade process, always wait at least 5–10 minutes before restarting the product, even if you suspect the upgrade has failed.

AXIS Camera Management can be used for multiple upgrades. See www.axis.com for more information.

Note

• Your dealer reserves the right to charge for any repair attributable to faulty upgrade by the user.

• Preconfigured and customized settings are saved when the firmware is upgraded (providing the features are available in the new firmware) although this is not guaranteed by Axis Communications AB.

Emergency recovery procedure

If power or network connection is lost during the upgrade, the process fails and the product becomes unresponsive. Flashing red Status indicator indicates a failed upgrade. To recover the product, follow the steps below. The serial number is found on the product’s label.

1. In

UNIX/Linux, type the following from the command line:

49

AXIS P5534 PTZ Dome Network Camera

Troubleshooting

arp -s <IP address> <serial number> temp ping -s 408 <IP address>

In Windows, type the following from a command/DOS prompt: arp -s <IP address> <serial number> ping -l 408 -t <IP address>

2. If the product does not reply within a few seconds, restart it and wait for a reply. Press CTRL+C to stop Ping.

3. Open a browser and type in the product’s IP address. In the page that appears, use the

Browse button to select the upgrade file to use. Then click

Load to restart the upgrade process.

4. After the upgrade is complete (1–10 minutes), the product automatically restarts and shows a steady green on the Status indicator.

5. Reinstall the product, referring to the Installation Guide.

If the emergency recovery procedure does not get the product up and running again, contact Axis support at www.axis.com/techsup/

Symptoms, possible causes and remedial actions

Problems setting the IP address

When using ARP/Ping

Try the installation again. The IP address must be set within two minutes after power has been applied to the product. Ensure the Ping length is set to 408. See the Installation Guide for detailed instructions.

The product is located on a different subnet

The IP address is being used by another device

If the IP address intended for the product and the IP address of the computer used to access the product are located on different subnets, you will not be able to set the IP address. Contact your network administrator to obtain an IP address.

Disconnect the Axis product from the network. Run the Ping command (in a Command/DOS window, type ping and the IP address of the product:

Possible IP address conflict with another device on the same subnet.

• If you receive: Reply from <IP address>: bytes=32; time=10...

this means that the IP address may already be in use by another device on the network.

Obtain a new IP address from the network administrator and reinstall the product.

• If you receive: Request timed out, this means that the IP address is available for use with the Axis product. Check all cabling and reinstall the product.

The static IP address in the Axis product is used before the DHCP server sets a dynamic address.

This means that if the same default static IP address is also used by another device, there may be problems accessing the product.

The product cannot be accessed from a browser

Cannot log in

When HTTPS is enabled, ensure that the correct protocol (HTTP or HTTPS) is used when attempting to log in. You may need to manually type http or https in the browser’s address field.

The IP address has been changed by DHCP

If the product and the client are on the same network, run AXIS IP Utility to locate the product.

Identify the product using its model or serial number.

Certificate error when using

IEEE 802.1X

Move the Axis product to an isolated network, or to one with no DHCP or BOOTP server. Set the IP address again, using AXIS IP Utility or ARP/Ping (see the Installation Guide). Open the Setup pages and disabled DHCP in the TCP/IP settings. Return the product to the main network. The product now has a fixed IP address that will not change.

For authentication to work properly, the date and time settings in the Axis product should be

synchronized with an NTP server. See Date & Time, on page 38.

50

AXIS P5534 PTZ Dome Network Camera

Troubleshooting

The product is accessible locally but not externally

Router configuration

Firewall protection

To configure your router to allow incoming data traffic to the Axis product, enable the NAT-traversal feature which will attempt to automatically configure the router to allow access to the Axis

product, see NAT traversal (port mapping) for IPv4, on page 41. The router must support UPnP

Check the Internet firewall with your network administrator.

TM

.

Default routers required

Check if you need to configure the router settings.

Problems with the H.264 format

No H.264 displayed in the client

Check that the relevant H.264 connection methods and correct interface are enabled in the AMC

Control Panel (streaming tab). See AXIS Media Control (AMC), on page 12.

In the AMC Control Panel, select the H.264 tab and click Set to default H.264 decoder.

No multicast H.264

displayed in the client

Check that RTSP is enabled under System Options > Network > TCP/IP > Advanced.

Check with your network administrator that the multicast addresses used by the Axis product are valid for your network.

Multicast H.264 only accessible by local clients

Poor rendering of H.264

images

Check with your network administrator to see if there is a firewall preventing viewing.

Check if your router supports multicasting, or if the router settings between the client and the product need to be configured. The TTL (Time To Live) value may need to be increased.

Color depth set incorrectly on clients. Set to 16–bit or 32–bit color.

If text overlays are blurred, or if there are other rendering problems, you may need to enable

Advanced Video Rendering fromv the Video tab in the AMC Control Panel.

Color saturation is different in H.264 and Motion JPEG

Lower frame rate than expected

Why do I not get maximum frames per second?

Image degeneration

Ensure that your graphics card is using the latest driver. The latest drivers can usually be downloaded from the manufacturer’s website.

Modify the settings for your graphics adapter. Refer to the adapter’s documentation for more information.

Reduce the number of applications running on the client computer.

Limit the number of simultaneous viewers.

Check with the network administrator that there is enough bandwidth available.

Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to

Decode only

key frames.

Lower the image resolution.

See Performance considerations, on page 56.

The maximum frames per second is dependent on the utility frequency (60/50 Hz) of the Axis

product. See Technical Specifications, on page 54.

Decrease the GOV length. Go to

Video & Audio > Video Stream and select the H.264 tab to modify the GOV length.

Status indicator LED is flashing red and the product is inaccessible

A firmware upgrade has been interrupted or the firmware has otherwise been damaged

See Emergency recovery procedure, on page 49.

51

AXIS P5534 PTZ Dome Network Camera

Troubleshooting

No images displayed on web page

Problems with AXIS Media

Control (Internet Explorer

only)

Installation of additional

ActiveX component restricted or prohibited

To enable the updating of video images in Internet Explorer, set the browser to allow ActiveX controls. Also, make sure that AXIS Media Control is installed on your computer.

Configure the Axis product to use a Java applet for updating video images in Internet Explorer. Go to Setup > Live View Config and select Java applet under Default viewer.

Video and image problems, general

Image too dark or too light Check the video stream and camera settings under

Setup > Video & Audio > Video Stream and

Setup > Video & Audio > Camera Settings.

Missing images in uploads This can occur when trying to use a larger image buffer than is actually available. Try lowering the frame rate or the upload period.

Slow image update

Poor performance

Configuring pre-buffers, motion detection, high-resolution images or high frame rates will affect the performance of the Axis product.

Poor performance may be caused by heavy network traffic, multiple users accessing the product, low performance clients, use of features such as motion detection, event handling or uploaded applications.

Poor quality snapshot images

Screen incorrectly configured on your computer

Configure your screen to show at least 65000 colors, that is, at least 16 bits. Using only 16 or 256 colors will produce dithering artifacts in the image.

Overlay image is not displayed

Incorrect size or location of overlay image

The overlay image may have been positioned incorrectly or may be too large. See Overlay Image

Settings in the online help for more information.

Privacy mask is not displayed

Incorrect size or location of privacy mask

The privacy mask may have been positioned incorrectly or may be too large.

Browser freezes

Firefox can sometimes freeze on a slow computer

Lower the image resolution

Problems uploading files

Limited space There is only limited space available for the upload of your own files. Delete existing files to free up space.

Motion Detection triggers unexpectedly

Changes in luminance Motion detection is based on changes in luminance in the image. This means that if there are sudden changes in the lighting, motion detection may trigger mistakenly. Lower the sensitivity setting to avoid problems with luminance.

52

AXIS P5534 PTZ Dome Network Camera

Troubleshooting

No audio

Incorrect setup

No audio or very poor audio quality

Check the sound card in the computer. Ensure that mute is not selected and that the volume settings are correct.

Check that Enable audio support is selected under Setup > System Options > Security > Audio

Support.

Check that the correct

Audio Input source is selected under Setup > Video & Audio > Audio

Settings.

Poor audio quality

CPU overloaded

Unsynchronized audio and video

Distorted audio

Feedback loops

Reduce the number of listeners and viewers. Decrease image resolution and compression.

Synchronize the product’s date and time settings with an NTP server. Go to

Setup > System

Options > Date & Time.

Check that the correct

Audio Input source is selected under Setup > Video & Audio > Audio

Settings.

Feedback loops might appear in full-duplex mode. Try moving the microphone or the speaker, or use half-duplex mode instead.

Storage and disk management problems

Video cannot be recorded

Check that the SD card is not write protected (that is, read only).

SD card cannot be mounted Reformat the SD card and then click Mount.

53

AXIS P5534 PTZ Dome Network Camera

Technical Specifications

Technical Specifications

Function/group

Item

Camera Model

Image sensor

Video

Specifications

AXIS P5534 50 Hz, AXIS 5534 60 Hz

Progressive scan CCD 1/3”

Lens

f=4.7 – 84.6 mm, F1.6 – 2.8, autofocus, automatic day/night

Horizontal angle of view: 55.2° - 3.2°

Minimum illumination

Shutter time

Color: 0.74 lux at 30 IRE F1.6

B/W: 0.04 lux at 30 IRE F1.6

Pan/Tilt/Zoom

1/10 000 s to 1/4 s

E-flip, Auto-flip, 100 preset positions

Pan: 360° (with Auto-flip), 0.2° - 300°/s

Tilt: 180°, 0.2° – 300°/s

18x optical zoom and 12x digital zoom, total 216x zoom

Video compression

Resolutions

H.264 (MPEG-4 Part 10/AVC, Baseline profile)

Motion JPEG

1280x720 to 320x180

Frame rate H.264

30/25 fps (60/50 Hz) in all resolutions

Frame rate

Motion JPEG

Video streaming

30/25 fps (60/50 Hz) in all resolutions

Multiple, individually configurable streams in H.264 and Motion JPEG

Controllable frame rate and bandwidth

VBR/CBR H.264

Pan/Tilt/Zoom functionalities

Audio

Image settings

Audio streaming

Audio compression

Limited guard tour

Control queue

On-screen directional indicator

Compression, color, brightness, sharpness, white balance, exposure control, exposure zones, backlight compensation, fine tuning of behavior at low light

Rotation: 0°, 180°

Text and image overlay

3D Privacy mask

Image freeze on PTZ

Wide dynamic range

Manual shutter time

Two-wayx

AAC LC 8 kHz 32 kbit/s, 16 kHz 64 kbit/s

G.711 PCM 8 kHz 64 kbit/s

G.726 ADPCM 8 kHz 32 kbit/s or 24 kbit/s

Configurable bit rate

Audio input/output

Requires multi-connector cable (not included) for external microphone input or line input and line output

54

AXIS P5534 PTZ Dome Network Camera

Technical Specifications

Function/group

Network

System

Integration

General

Item

Security

Supported protocols

Application

Programming

Interface

Intelligent video

Triggers

Actions

Video access from web browser

Management and maintenance

Installation aids

Casing

Processor, memory

Power

Specifications

Password protection, IP address filtering, HTTPS encryption*, IEEE 802.1X network access control*, digest authentication, user access log

*This product includes software developed by the Open SSL Project for use in the Open

SSL Toolkit (www.openssl.org)

IPv4/v6, HTTP, HTTPS*, SSL/TLS*, QoS Layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP,

SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP,

DHCP, ARP, SOCKS

*This product includes software developed by the Open SSL Project for use in the Open

SSL Toolkit (www.openssl.org)

Open API for software integration, including VAPIX® and AXIS Camera Application

Platform from Axis Communications; specifications available at www.axis.com

Includes the ONVIF specification available at www.onvif.org

Support for AXIS Video Hosting System (AVHS) with One-Click Camera Connection

Video motion detection, audio detection, Advanced Gatekeeper, Support for AXIS Camera

Application Platform enabling installation of additional applications

Intelligent video, digital input, manual trigger, PTZ preset, PTZ moving, network lost, temperature, fan status, edge storage status, system initializing

Day/Night Vision Mode

Play Audio Clip

PTZ preset

Guard tour

Video recording to edge storage

File upload via FTP, HTTP, email and network share

Notification via email, HTTP and TCP

Pre- and post alarm video buffering

Camera live view

Video recording to file (ASF)

Customizable HTML pages

Windows 7, Windows Vista, Windows XP, Windows Server 2008, Windows Server 2003

DirectX 9c or higher

For other operating systems and browsers, see www.axis.com/techsup

AXIS Camera Management tool on CD and web-based configuration

Firmware upgrades over HTTP or FTP, firmware available on www.axis.com

Pixel counter

IP51-rated, metal casing (aluminum), acrylic (PMMA) clear dome

ARTPEC-3, 256 MB RAM, 128 MB Flash

Connectors

Edge storage

Operating conditions

Power over Ethernet Plus (PoE+) IEEE 802.3at, max. 30 W

20-24 V AC, max. 23.6 VA

24-34 V DC, max. 17 W

AXIS T8123 High PoE Midspan 1-port: 100-240 V AC, max. 37 W

RJ-45 for 10BASE-T/100BASE-TX PoE

Multi-connector (cable not included) for: power in, 4 configurable alarm inputs and outputs, mic in (max 74 mVpp), line mono input (max 6.2 Vpp), line mono output (max 2.8 Vpp) to active speaker

SD/SDHC memory card slot (card not included)

Support for recording to network share (Network Attached Storage or file server).

Temperature: 0 ºC to 50 ºC (32 ºF to 122 ºF)

Humidity 20–80% RH (non-condensing)

55

AXIS P5534 PTZ Dome Network Camera

Technical Specifications

Function/group

Item

Approvals

Dimensions

(HxWxD)

Weight

Included accessories

Video management software (not included)

Optional accessories

Specifications

EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN

55024, FCC Part 15 Subpart B Class B, ICES-003 Class B, VCCI Class B, C-tick AS/NZS

CISPR 22, EN 60950-1, KCC Class B IEC 60721-4-3 Class 3K3, 3M3, EN/IEC 60068-2

IP51

Midspan: EN 60950-1, GS, UL, cUL, CE, VCCI, CB, KCC

Camera with hard-ceiling mount: 195 x 183 x 183 mm (7.7” x 7.2” x 7.2”)

Camera with drop-ceiling mount: 195 x 238 x 238 mm (7.7” x 9.4” x 9.4”)

Camera: 1.9 kg (4.2 lb.)

Camera with drop-ceiling mount: 2.3 kg (5.1 lb.)

AXIS T8123 High PoE Midspan 1-port, mounting kit for hard and drop ceilings, clear and smoked dome cover, Installation Guide, CD with User Manual, recording software, installation and management tools, Windows decoder 1-user license

AXIS Camera Station — Video management software for viewing and recording up to 50 cameras

See www.axis.com/products/video/software/ for more software applications via partners

AXIS T8310 Video Surveillance Control Board

AXIS T90A Illuminators

AXIS T91A Mounting Accessories

Multi-connector cable for AC/DC power, I/Os and audio

Performance considerations

When settings up your system, it is important to consider how various settings and situations will affect performance. Some factors affect the amount of bandwidth (the bit rate) required, others can affect the frame rate, and some affect both. If the load on the

CPU reaches its maximum, this will also affect the frame rate.

The following factors are among the most important to consider:

• High image resolution and/or lower compression levels result in images containing more data. Bandwidth affected.

• Access by large numbers of Motion JPEG and/or unicast H.264 clients. Bandwidth affected.

• Simultaneous viewing of different streams (resolution, compression) by different clients. Effect on frame rate and bandwidth.

• Accessing Motion JPEG and H.264 video streams simultaneously. Frame rate and bandwidth affected.

• Heavy usage of event settings affect the product’s CPU load. Frame rate affected.

• Heavy network utilization due to poor infrastructure. Bandwidth affected.

• Viewing on poorly performing client computers lowers perceived performance. Frame rate affected.

56

User Manual

AXIS P5534 PTZ Dome Network Camera

© Axis Communications AB, 2011

Ver. M1.12

Date: December 2011

Part No. 45175

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement