INSTALLATION & OPERATING INSTRUCTIONS Models 122–322 Types H, WH & P L W WARNING: If these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. This manual should be maintained in legible condition and kept adjacent to the heater or in another safe place for future reference. CATALOG NO. 1000.53H Effective: 09-19-08 Replaces: 11-16-07 P/N 241112 Rev. 9 Rev. 9 reflects the following: Changes to: The text in the BEFORE INSTALLATION section on page 5; the text in paragraph one of the GENERAL SAFETY section on page 8; the text in paragraph one of the Outdoor Installations section on page 10; Table E on page 10; the wiring diagram on page 35. 2 CONTENTS WARNINGS 4 Pay Attention to These Terms 4 BEFORE INSTALLATION 5 Product Receipt 5 Model Identification 5 Ratings and Certifications 5 Installations at Elevation 5 Component Locations 6 General Information 7 Time/Temperature Relationships in Scalds 8 GENERAL SAFETY 8 Clearances 9 Equipment Base 9 INSTALLATION 9 Installation Codes 9 Combustion and Ventilation Air 11 Conventional Combustion Air Supply 11 Water Piping 12 Hydronic Heating 13 Domestic Hot Water Piping 15 Pool Heating 17 Gas Supply 17 Electrical Power Connections 19 Venting 21 Outdoor Installation 32 High Limit (Manual Reset) 33 Flow Switch 33 CONTROLS 33 Ignition Control Module 33 Low Water Cut Off (Optional) 34 Operating Control 34 WIRING DIAGRAM—MODELS 122 –322 35 PRE-START-UP 36 Filling System-Heating Heaters 36 Domestic Hot Water Heaters 36 Inspect Venting System 36 For Your Safety Read Before Lighting 36 Pre-Start-Up Check 36 INITIAL START-UP 36 Tools Needed 36 Preparation for Start-Up 36 Start-Up 37 Main Burner Adjustment Safety Inspection Follow-Up POST START-UP CHECK OPERATION Operating Instructions To Turn Off Gas To Appliance MAINTENANCE Suggested Minimum Maintenance Schedule APPENDIX Inside Combustion Air Contamination 3 37 37 38 38 38 38 39 39 39 40 40 WARNINGS - Pay Attention to These Terms DANGER: Indicates the presence of immediate hazards which will cause severe personal injury, death or substantial property damage if ignored. WARNING: Indicates the presence of hazards or unsafe practices which could cause severe personal injury, death or substantial property damage if ignored. CAUTION: Indicates the presence of hazards or unsafe practices which could cause minor personal injury or product or property damage if ignored. NOTE: Indicates special instructions on installation, operation, or maintenance which are important but not related to personal injury hazards. DANGER: Make sure the gas on which the heater will operate is the same type as that specified on the heater rating plate. WARNING: To minimize the possibility of improper operation, serious personal injury, fire, or damage to the heater: WARNING: Should overheating occur or the gas supply valve fail to shut, do not turn off or disconnect the electrical supply to the heater. Instead, shut off the gas supply at a location external to the heater. • Always keep the area around the heater free of combustible materials, gasoline, and other flammable liquids and vapors. • Heater should never be covered or have any blockage to the flow of fresh air to the heater. WARNING: Risk of electrical shock. More than one disconnect switch may be required to deenergize the equipment before servicing. WARNING: Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. WARNING - CALIFORNIA PROPOSITION 65: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. CAUTION: Operation of this heater in lowtemperature systems requires special piping. Harmful internal condensation will occur if the inlet water temperature does not exceed 105°F. Warranty claims will be denied when condensation occurs. WARNING: This unit contains refractory ceramic fiber (RCF) insulation in the combustion chamber. RCF, as manufactured, does not contain respirable crystalline silica. However, following sustained exposure to very high temperatures (>2192F), the RCF can transform into crystalline silica (cristabolite). The International Agency for Research on Cancer (IARC) has classified the inhalation of crystalline silica (cristabolite) as carcinogenic to humans. CAUTION: If this heater is to be installed above radiation level, it must be provided with a low water cut-off device at the time of heater installation. CAUTION: If this heater is to be installed in a negative or positive pressure equipment room, there are special installation requirements. Consult factory for details. When removing the burners or heat exchangers, take precautions to avoid creating airborne dust and avoid inhaling airborne fibers. When cleaning spills, use wet sweeping or High Efficiency Particulate Air (HEPA) filtered vacuum to minimize airborne dust. Use feasible engineering controls such as local exhaust ventilation or dust collecting systems to minimize airborne dust. Wear appropriate personal protective equipment including gloves, safety glasses with side shields, and appropriate NIOSH certified respiratory protection, to avoid inhalation of airborne dust and airborne fiber particles. CAUTION: This heater requires forced water circulation when the burner is operating. See minimum and maximum flow rates. Severe damage will occur if the heater is operated without proper water flow circulation. 4 BEFORE INSTALLATION the left inside jacket of the heater. The model number will have the form H3 0162 or similar depending on the heater size and configuration. The first character of the model number identifies application (H = Hydronic Heating System, WH = Hot Water Supply System, P = Pool Application). The second character identifies the firing mode (3 - two stage firing, 4 - On/Off firing ). The next four places identify the size of the heater. Raypak strongly recommends that this manual be reviewed thoroughly before installing your Hi Delta heater. Please review the General Safety information before installing the heater. Factory warranty does not apply to heaters that have been improperly installed or operated (refer to the warranty at the back of this manual). Installation and service must be performed by a qualified installer, service agency or the gas supplier. If, after reviewing this manual, you still have questions which this manual does not answer, please contact your local Raypak representative or visit our website at www.raypak.com. Ratings and Certifications Standards: • Gas-Fired Low Pressure Steam and Hot Water Heaters, ANSI Z21-13 • CSA 4.9 - latest edition Industrial and Commercial Gas-Fired Package Heaters, CAN 3.1 - latest edition Gas-Fired Pool Heaters, ANSI Z21.56 • CSA 4.7 latest edition Gas Water Heaters, ANSI Z21.10.3 • CSA 4.3 - latest edition Thank you for purchasing a Raypak product. We hope you will be satisfied with the high quality and durability of our equipment. • Product Receipt • On receipt of your heater it is suggested that you visually check for external damage to the shipping crate. If the crate is damaged, make a note to that effect on the Bill of Lading when signing for the shipment. Next, remove the heater from the shipping packaging. Report any damage to the carrier immediately. All Raypak heaters are National Board Approved, and design-certified and tested by the Canadian Standards Association (CSA) for the U.S. and Canada. Each heater is constructed in accordance with Section IV of the American Society of Mechanical Engineers (ASME) Heater Pressure Vessel Code and bears the ASME stamp. The heater also complies with the latest edition of ASHRAE 90.1 Standard. • On occasion, items are shipped loose. Be sure that you receive the correct number of packages as indicated on the Bill of Lading. WARNING: Altering any Raypak pressure vessel by installing replacement heat exchangers, tube bundle headers, or any ASME parts not manufactured and/or approved by Raypak will instantly void the ASME and CSA ratings of the vessel and any Raypak warranty on the vessel. Altering the ASME or CSA ratings of the vessel also violates national, state, and local approval codes. Claims for shortages and damages must be filed with the carrier by consignee. Permission to return goods must be received from the factory prior to shipping. Goods returned to the factory without an authorized Returned Goods Receipt number will not be accepted. All returned goods are subject to a restocking charge. When ordering parts, you must specify the model and serial number of the heater. When ordering under warranty conditions, you must also specify the date of installation. Installations at Elevation Rated inputs are suitable for up to 4500 feet elevation without de-rate. Consult the Factory for installations at any altitude in excess of 4500 feet. Purchased parts are subject to replacement only under the manufacturer’s warranty. Debits for defective replacement parts will not be accepted. Parts will be replaced in kind only per Raypak’s standard warranties. Model Identification The model identification number and heater serial number are found on the heater data plate located on 5 Component Locations COMBUSTION AIR INTAKE FLUE EXHAUST Fig. 1: Component Locations—Back PRESSURE RELIEF CONNECTION WATER OUTLET GAS CONNECTION WATER INLET VIEW PORT Fig. 2: Component Locations—Left Side HI LIMITS HI-LIMITS Fig# 9399 Panels removed for clarity Fig. 3: Component Locations—Front 6 General Information Model No. Quantity of Vent Size (in.) Burners Gas Valves Blowers Flue Intake 122 3 2* 1 4 5 162 4 2* 1 5 5 202 5 2* 1 5 5 242 6 2* 1 5 5 322 8 2* 1 6 5 *Second valve located inside air plenum Table A: Basic Data Model Burners per Valve No. A B Stages % Fire at Stage 1 2 1 2 122 2 1 A AB 66 100 162 3 1 A AB 75 100 202 3 2 A AB 60 100 242 4 2 A AB 66 100 322 5 3 A AB 63 100 Table B: Manifold Data Fig. 5: Air Shutter Adjustment Fig. 4: Gas Valve Detail 7 GENERAL SAFETY To meet commercial hot water use needs, the high limit safety control on this water heater will shut off the main gas valve before the outlet temperature reaches 210°F. However, water temperatures over 125°F can cause instant severe burns or death from scalds. When supplying general purpose hot water, the recommended initial setting for the temperature control is 125°F. Safety and energy conservation are factors to be considered when setting the water temperature on the thermostat. The most energy-efficient operation will result when the temperature setting is the lowest that satisfies the needs of the application. Water temperature over 125°F can cause instant severe burns or death from scalds. Children, disabled, and elderly are at highest risk of being scalded. Water temperature over 125°F can cause instant severe burns or death from scalds. Children, disabled and elderly are at highest risk of being scalded. • • See instruction manual before setting temperature at water heater. Feel water before bathing or showering. Temperature limiting valves are available. Feel water before bathing or showering. NOTE: When this water heater is supplying general purpose hot water for use by individuals, a thermostatically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further information. Temperature limiting valves are available, see manual. Time/Temperature Relationships in Scalds The following chart details the relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the safest water temperature for your applications. Maximum water temperatures occur just after the heater’s burner has shut off. To determine the water temperature being delivered, turn on a hot water faucet and place a thermometer in the hot water stream and read the thermometer. Water Temp. Time to Produce Serious Burn 120°F More than 5 minutes 125°F 1-1/2 to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1-1/2 seconds 155°F About 1 second Table courtesy of The Shriners Burn Institute Table C: Time to Produce Serious Burn 8 Equipment Base The temperature of the water in the heater can be regulated by using the temperature control. To comply with safety regulations, the temperature control is set at the lowest setting when shipped from the factory. The heater should be mounted on a level, structurally sound surface. The heater is approved for installation on a combustible surface but must NEVER be installed on carpeting. Gas-fueled equipment installed in enclosed parking garages must be located at least 18 in. above the floor. To adjust the water temperature, insert a small straight screwdriver into the adjustment screw on the front of temperature control and turn the wheel to the desired setting (See Fig. 6). CAUTION: The heater should be located in an area where water leakage will not result in damage to the area adjacent to the appliance or to the structure. When such locations cannot be avoided, it is recommended that a suitable catch pan, adequately drained, be installed under the appliance. The pan must not restrict air flow. In addition, the heater shall be installed such that the gas ignition system components are protected from water (dripping, spraying, rain, etc.) during appliance operation or service (circulator replacement, control replacement, etc.). WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the Commonweatlh of Massachusetts. Fig. 6: Temperature Control CAUTION: Hotter water increases the risk of scaldINSTALLATION ing! There is a hot water scald potential if the Clearances thermostat is set too high. Indoor Installations INSTALLATION Heater Side Installation Codes Installations must follow these codes: · · · · · Local, state, provincial, and national codes, laws, regulations and ordinances. National Fuel Gas Code, ANSI Z223.1- latest edition (NFGC). National Electrical Code, ANSI/NFPA 70 - latest edition (NEC). Standard for Controls and Safety Devices for Automatically Fired Heaters, ANSI/ASME CSD-1, when required (CSD-1). For Canada only: CAN/CGA B149 Installation Code (B149) and C.S.A. C22. 1 C.E.C. Part 1 (C22. 1). Minimum Clearance Recommended Service from Combustible Clearance Surfaces Floor* 0” 0” Rear 1” 24” Water Side 12” 24” Other Side 1” 24” Top 1” 1” Front Open 24” Vent 2” 2” * DO NOT install on carpeting. Table D: Clearances – Indoor Installations 9 FRONT VIEW TOP VIEW Fig. 7: Minimum Clearances from Combustible Surfaces—Indoor Installations Outdoor Installations When installed according to the listed minimum clearances from combustible construction, these heaters can still be serviced without removing permanent structural construction around the heater. However, for ease of servicing, we recommend a clearance of at least 24 in. in front, and at least 36 in. on the water connection side. This will allow the heater to be serviced in its installed location without movement or removal of the heater. These heaters are design-certified for outdoor installation. Heaters must not be installed under an overhang unless clearances are in accordance with local installation codes and the requirements of the gas supplier. Three sides must be open in the area under the overhang. Roof water drainage must be diverted away from heaters installed under overhangs. Service clearances less than the minimums may require removal of the heater to service either the heat exchanger or the burner tray. In either case, the heater must be installed in a manner that will enable the heater to be serviced without removing any structure around the heater. Heater Side Min. Clearance Recommended Service from Combustible Clearance Surfaces Front Open 24” Rear 12” 24” Water Side 36” 36” Other Side 36” 36” Top Unobstructed 36” Vent N/A N/A Table E: Clearances – Outdoor Installations !$ !$ Fig. 8: Minimum Clearances from Combustible Surfaces—Outdoor Installations 10 a motorized sealed damper to prevent the circulation of cold air through the heater during the non-operating hours. These clearances are required when the outdoor vent cap is used. If installing the heater outdoors with a vent stack, the indoor clearances may be utilized. Conventional Combustion Air Supply The combustion air intake hood MUST be used for outdoor installations. The hood is shipped loose and installed on the side of the heater over the filter box at the job site. U.S. Installations All Air from Inside the Building Combustion and Ventilation Air The confined space shall be provided with two permanent openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all spaces meets the criteria for an unconfined space. The total input of all gas utilization equipment installed in the combined space shall be considered in making this determination. Each opening shall have a minimum free area of 1 square inch per 1,000 Btu per hour (22 cm² per kW) of the total input rating of all gas utilization equipment in the confined space, but not less than 100 in.² (645 cm²). One opening shall commence within 12 in. (30 cm) of the top, and one opening shall commence within 12 in. (30 cm) of the bottom, of the enclosure. The minimum dimension of air openings shall be not less than 3 in. (8 cm) in any direction. Indoor Units The heater must be supplied with sufficient quantities of non-contaminated air to support proper combustion and equipment ventilation. Combustion air can be supplied via conventional means where combustion air is drawn from the area immediately surrounding the heater, or via direct vent, where combustion air is drawn directly from outside. All installations must comply with the requirements of the NFGC (U.S.) and B149 (Canada), and all local codes. CAUTION: Combustion air must not be contaminated by corrosive chemical fumes which can damage the heater and void the warranty. (See the Appendix.) All Air from Outdoors The confined space shall communicate with the outdoors in accordance with methods 1 or 2. The minimum dimension of air openings shall not be less than 3 in. (8 cm) in any direction. Where ducts are used, they shall be of the same cross-sectional area as the free area of the openings to which they connect. Direct Combustion Air If outside air is drawn through the intake pipe directly to the unit for combustion: 1. Install combustion air direct vent in accordance with the venting section of this manual. 1. Two permanent openings, one commencing within 12 in. (30 cm) of the top, and one commencing within 12 in. (30 cm) of the bottom, of the enclosure shall be provided. The openings shall communicate directly, or by ducts, with the outdoors or spaces (crawl or attic) that freely communicate with the outdoors. 2. Provide adequate ventilation of the space occupied by the heater(s) by an opening(s) for ventilation air at the highest practical point communicating with the outdoors. The total cross-sectional area shall be at least 1 in.2 of free area per 20,000 BTUH (111 mm2 per kW) of total input rating of all equipment in the room when the opening is communicating directly with the outdoors or through vertical duct(s). The total cross-sectional area shall be at least 1 in.2 of free area per 10,000 BTUH (222 mm2 per kW) of total input rating of all equipment in the room when the opening is communicating with the outdoors through horizontal duct(s). a. Where directly communicating with the outdoors or where communicating to the outdoors through vertical ducts, each opening shall have a minimum free area of 1 sq in. per 4000 Btu per hr (5.5 cm2 per kW) of total input rating of all equipment in the enclosure. b. Where communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 sq in. per 2000 3. In cold climates, and to mitigate potential freezeup, Raypak highly recommends the installation of 11 Btu per hr (11 cm2 per kW) of total input rating of all equipment in the enclosure. than 18 in. (450 mm) nor less than 6 in. (150 mm) above the floor level. The duct can also "Goose Neck" through the roof. The duct is preferred straight down 18” from floor, but do not place near piping. This air supply opening requirement shall be in addition to the air opening for ventilation air required in (1). 2. One permanent opening, commencing within 12 in. (30 cm) of the top of the enclosure, shall be permitted where the equipment has clearances of at least 1 in. (2.5 cm) from the sides and back and 6 in. (16 cm) from the front of the appliance. The opening shall directly communicate with the outdoors or shall communicate through a vertical or horizontal duct to the outdoors or spaces (crawl or attic) that freely communicate with the outdoors, and shall have a minimum free area of: 3. For heaters not using a barometric damper in the vent system, and when air supply is provided by natural air flow from outdoors for a power burner and there is no draft regulator, drafthood or similar flue gas dilution device installed in the same space, in addition to the opening for ventilation air required in (1), there shall be a permanent air supply opening(s) having a total cross-sectional area of not less than 1 sq. in. for each 30,000 BTUH (70 sq. mm per kW) of total rated input of the burner(s), and the location of the opening(s) shall not interfere with the intended purpose of the opening(s) for ventilation air referred to (1). This opening(s) can be ducted to a point neither more than 18 in. (450 mm) nor less than 6 in. (150 mm) above the floor level. The duct can also "Goose Neck" through the roof. The duct is preferred to be straight down 18” from floor, but do not place near piping. a. 1 sq in. per 3000 Btu per hr (7 cm2 per kW) of the total input rating of all equipment located in the enclosure, and b. Not less than the sum of the areas of all vent connectors in the confined space. WARNING: Do not use one permanent opening method if the equipment room is under negative pressure conditions or the equipment is common vented with other gas-fired appliances. Canadian Installations 4. Refer to the latest version of the B149 for additional information. CAUTION: All combustion air must be drawn from the air outside of the building; the mechanical equipment room must communicate directly with the outdoors. Water Piping General The heater should be located so that any water leaks will not cause damage to the adjacent area or structures. 1. Ventilation of the space occupied by the heater shall be provided by an opening(s) for ventilation air at the highest practical point communicating with outdoors. The total cross-sectional area of such an opening(s) shall be at least 10% of the area required in (2) and (3), but in no case shall the cross-sectional area be less than 10 sq. in. (6500 sq. mm.). CAUTION: This heater requires forced water circulation when the burner is operating. See Table F and Table G for minimum and maximum flow rates and water pump selection. The pump must be interlocked with the heater to prevent heater operation without water circulation. 2. For heaters using a barometric damper in the vent system, and when air supply is provided by natural air flow from the outdoors for natural draft, partial fan assisted, fan-assisted or power draftassisted burners, there shall be a permanent air supply opening(s) having a cross section area of not less than 1 sq. in. per 7000 BTUH (310 sq. mm per kW) up to and including 1 million BTUH, plus 1 sq. in. per 14000 BTUH (155 sq. mm per kW) in excess of 1 million BTUH. This opening(s) shall be either located at or ducted to a point neither more Relief Valve Piping WARNING: Pressure relief valve discharge piping must be piped near the floor and close to a drain to eliminate the potential of severe burns. Do not pipe to any area where freezing could occur. Refer to local codes. 12 Hydrostatic Test Low Temperature System Unlike many other types of heaters, Raypak heaters do not require hydrostatic testing prior to being placed in operation. The heat exchanger has already been factory-tested and is rated for 160 PSI maximum operating pressure. However, Raypak does recommend hydrostatically testing the piping connections to the heater and the rest of the system prior to operation. This is particularly true for hydronic systems using expensive glycol-based antifreeze. Raypak recommends conducting the hydrostatic test before connecting gas piping or electrical supply. Heater requires minimum inlet temperature of 105°F. Consult the following sections for piping details. Temperature & Pressure Gauge The temperature and pressure gauge is factorymounted in the in/out header. Hydronic Heating Pump Selection Leaks must be repaired at once to prevent damage to the heater. NEVER use petroleum-based stop-leak compounds. In order to ensure proper performance of your boiler system, you must install a properly sized pump. Raypak recommends using a 20°F Delta T as design Delta T. (Delta T is the temperature difference between the inlet and outlet water when the heater is firing at full rate). If a Delta T larger than 20°F is necessary, see Table F for minimum flow rate requirements. 1. Connect fill water supply. Fill heater with water (be sure bleed valve is open). When water flows from bleed valve, shut off water. Close bleed valve. Carefully fill the rest of the system, being sure to eliminate any entrapped air by using high point vents. Close feed valve. Test at standard operating pressure for at least 24 hours. Pressure Drop in Feet of Head Feedwater Regulator 2. Make sure constant gauge pressure has been maintained throughout test. Raypak recommends that a feedwater regulator be installed and set at 12 PSIG minimum pressure at the highest point of system. Install a check valve or back flow device upstream of the regulator, with a manual shut off valve as required by local codes. 3. Check for leaks. Repair if found. 10°F ΔT 20°F ΔT Model No. gpm ΔP (ft) gpm ΔP (ft) 122 20 2.5 10 162 27 4.5 202 34 242 40 322 30°F ΔT gpm ΔP (ft) Min. Flow Max. Flow gpm ΔP (ft) ΔT gpm ΔP (ft) ΔT <1.0 10* <1.0 20 30 5.3 7 13 1.10 10 <1.0 27 30 5.4 9 7.2 17 1.85 11 <1.0 10 <1.0 34 30 5.5 11 10.0 20 2.65 14 1.3 10 <1.0 40 44 11.8 9 27 4.70 18 2.2 14 1.4 40 44 12.2 12 * Flow switch (when used) will not activate at less than 12 gpm. NOTE: Basis for minimum flow - 10 gpm or 40° Delta T maximum flow - 44 gpm, except for 1.25” header. Table F: Heater Rates of Flow and Pressure Drops 13 Fig. 9: Single Boiler—Low Temperature Application (Heat Pump) Primary/Secondary Piping Fig. 10: Dual Boiler—Primary/Secondary Piping 14 Piping—Heating Boilers Three-Way Valves All high points should be vented. Purge valves and a bypass valve should be installed. A boiler installed above radiation level must be provided with a low water cut-off device. The boiler, when used in connection with a refrigeration system, must be installed so the chilled medium is piped in parallel with the boiler with appropriate valves to prevent the chilled medium from entering the boiler. Valves designed to blend water temperatures or reduce water circulation through the boiler should not be used. Raypak boilers are high recovery low mass boilers not subject to thermal shock. Raypak offers a full line of electric sequencers that produce direct reset of boiler water temperature. Refer to the Controls Section in our Complete Catalog. Domestic Hot Water Piping The boiler piping system of a hot water heating boiler connected to heating coils located in air handling units where they may be exposed to circulating refrigerated air, must be equipped with flow control valves or other automatic means to prevent gravity circulation of the boiler water during the cooling cycle. It is highly recommended that the piping be insulated. When designing the water piping system for domestic water applications, water hardness should be considered. Table G indicates the suggested flow rates for soft, medium and hard water. Hardness is specified as grains per gallon. Air-Separation/Expansion Tank All boilers should be equipped with a properly sized expansion tank and air separator fitting as shown in the diagrams. Model No. Soft (0–4 grains per gallon) Medium (5–15 grains per gallon) Hard* (16–25** grains per gallon) ΔT gpm ΔP MTS SHL ΔT gpm ΔP MTS SHL ΔT gpm ΔP MTS SHL 122 10 20 2.5 1-1/4 4.9 8 26 4.0 1-1/4 7.8 7 30 5.3 1-1/4 10.3 162 14 20 2.5 1-1/4 4.9 11 26 4.1 1-1/4 7.9 9 30 5.4 1-1/4 10.4 202 17 20 2.6 1-1/4 5.0 13 26 4.2 1-1/4 8.0 11 30 5.5 1-1/4 10.5 242 21 20 2.6 1-1/2 3.5 16 26 4.3 1-1/2 5.9 9 44 11.8 1-1/2 16.1 322 27 20 2.7 1-1/2 3.6 20 27 4.8 1-1/2 6.6 12 44 12.2 1-1/2 16.5 ΔT = Temperature rise, °F. ΔP = Pressure drop through heat exchanger, ft. SHL = System head loss, ft. (System head loss is based on the heater and tank placed no more than 5 feet apart and 25 feet equivalent length of pipe and fittings.) gpm = Gallons per minute, flow rate.) MTS = Minimum tubing size. *Must utilize optional cupro-nickel tubes. **With Hard Water (16-25 grains per gallon), the operating control must be set no higher than 130F for scale free operation. For operating temperatures above 130F, a water softener must be utilized. Table G: Domestic Water Heater Flow Rate Requirements 15 Fig. 11: Single Heater—Domestic Hot Water with One Storage Tank 16 Pool Heating Winterizing Your Heater When heaters installed outdoors in freezing climate areas are to be shut down for the winter, please observe the following procedure: CAUTION: Power to the heater should be interlocked with the main system pump to make sure the heater does not fire without the main system pump in operation. Improper flow control can damage the heater. Uncontrolled flow (too high) or restricted flow (too low) can seriously damage the heater. Follow these instructions to make sure your heater is properly installed. Heaters installed outdoors in freezing climate areas should be shut down for the winter. To shut down heater, turn off manual main gas valve and main gas shut-off. Close isolation valves and remove water piping from the in/out header of the heater. Drain the heater and any piping of all water that may experience below freezing temperatures. The Hi Delta pool heater is equipped with an external pump and bypass arrangement that blends outlet water with the inlet to increase the inlet water temperature, thereby reducing the likelihood of condensation forming on the heat exchanger. The pump also serves to circulate water through the heater from the main system piping. Pool and Spa Water Chemistry NOTE: Chemical imbalance can cause severe damage to your heater and associated equipment. Maintain your water pH between 7.4 and 7.8 and total alkalinity between 100 and 150 ppm. If the mineral content and dissolved solids in the water become too high, scale forms inside the heat exchanger tubes, reducing heater efficiency and also damaging the heater. If the pH drops below 7.2, the heater will be severely damaged. To complete the installation of the pool heater, the pool thermostat needs to be installed in the main return water line. This will ensure that the heater will be energized at the right time. If the main water line is too far away from the heater and the capillary bulb will not reach it, locate the pool thermostat adjacent to the main line and run wires back to the heater. NOTE: Heat exchanger damage resulting from chemical imbalance and/or scaling is not covered under the warranty. Adjustment of the bypass valve is critical to proper operation of the heater. The bypass valve should be adjusted to achieve a minimum inlet water temperature of 105°F and an outlet water temperature between 120°F and 140°F. When starting with a cold pool, make initial adjustments. Make final adjustments when pool water approaches desired temperature. Gas Supply DANGER: Make sure the gas on which the heater will operate is the same type as specified on the heater’s rating plate. Automatic Chlorinators and Chemical Feeders All chemicals must be introduced and completely diluted into the pool or spa water before being circulated through the heater. Do not place chlorine tablets or bromine sticks in the skimmer. High chemical concentrations will result when the pump is not running (i.e. overnight). Gas piping must have a sediment trap ahead of the heater gas controls, and a manual shut-off valve located outside the heater jacket. A pounds to inches regulator must be installed to reduce to gas supply pressure to under 10.5 in. WC. The regulator should be placed a minimum distance of 10 times the pipe diameter upstream of the heater gas controls. All gas piping must be tested after installation in accordance with local codes. The heater and its gas connection must be leak-tested before placing it in operation. Chlorinators must feed downstream of the heater and have an anti-siphoning device to prevent chemical backup into the heater when the pump is shut off. NOTE: High chemical concentrates from feeders and chlorinators that are out of adjustment will cause very rapid corrosion to the heat exchanger in the heater. Such damage is not covered under the warranty. 17 GAS FLOW MANUAL SHUT OFF VALVE SUPPLIED BY OTHERS SEDIMENT TRAP EXTENTS OF UNIT ENCLOSURE MANUAL SHUT OFF VALVE GAS FLOW SUPPLIED BY OTHERS EXTENTS OF UNIT ENCLOSURE SEDIMENT TRAP UNION TO BURNERS TO BURNERS Fig. 12: Sediment Trap Orientation Gas Supply Connection Gas Supply Pressure A minimum of 7 in. WC and a maximum of 10.5 in. WC upstream gas pressure is required under load and no load conditions for natural gas. A minimum of 11 in. WC and a maximum of 13 in. WC is required for propane gas. The gas pressure regulator supplied on the heater is for low pressure service. If upstream pressure exceeds 14 in. WC, an intermediate gas pressure regulator, of the lockup type, must be installed. CAUTION: The heater and its manual shutoff valve must be disconnected from the gas supply during any pressure testing of the gas supply system at test pressures in excess of 1/2 PSIG (3.45 kPa). The heater must be isolated from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG. Relieve test pressure in the gas supply line before reconnecting the heater and its manual shut off valve to the gas supply line. FAILURE TO FOLLOW THIS PROCEDURE MAY DAMAGE THE GAS VALVES. Over pressurized gas valves are not covered by warranty. The heater and its gas connections shall be leak tested before placing the appliance in operation. Use soapy water for leak test: DO NOT use open flame. When connecting additional gas utilization equipment to the gas piping system, the existing piping must be checked to determine if it has adequate capacity. Gas Pressure Regulator The gas valve pressure regulator(s) on the heater are nominally preset at 3.5 in. WC for natural gas, and 10.5 in. WC for propane gas manifold pressure. The pressure at the gas valve outlet tap, measured with a manometer,while in operation should be 3.5 ± 0.1 in. WC for natural gas and 10.5 in. ± 0.1 in. WC for propane gas. If an adjustment is needed, turn the adjustment screw clockwise to increase pressure or counter-clockwise to decrease pressure. CAUTION: Do not use Teflon tape on gas line pipe thread. A pipe compound rated for use with gas systems is recommended. Apply sparingly only on male pipe ends. CAUTION: Support gas supply piping with hangers, not by the heater or its accessories. Ensure the gas piping is protected from physical damage and freezing where required. 18 Electrical Power Connections Installations must follow these codes: · · · · National Electrical Code and any other national, state, provincial or local codes or regulations having jurisdiction Safety wiring must be N.E.C. Class 1 Heater must be electrically grounded as required by N.E.C. In Canada, C22.1 The heater is wired for 120 VAC, 12 AMPS. The voltage is indicated on the tie-in leads. Consult the wiring diagram shipped with the heater in the instruction packet. The remote tank control stat, thermostat, or electronic heater control as applicable, may be connected to stage selector terminal (See wiring diagram). 24 Volts are supplied to this connection through the heater transformer. DO NOT attach line voltage to the “TH” leads. Before starting the heater check to ensure proper voltage to the heater and pump. AC = 108 Volts AC Minimum, 132 Volts AC MAX AB = 108 Volts AC Minimum, 132 Volts AC MAX BC = < 1 Volt AC Fig. 13: Check Power Source Making the Electrical Connections Refer to Fig. 14 Wiring Connection, and the Wiring Diagram. Install a separate disconnect means for each load. Use appropriate-sized wire as defined by NEC, CSA and/or local code. All primary wiring should be 125% of minimum rating. 1. Verify circuit breaker is properly sized by referring to heater rating plate. A dedicated circuit breaker should be provided. It is strongly recommended that all individually-powered control modules and the heater should be supplied from the same power source. 2. Turn off all power to the heater. Verify that power has been turned off by testing with a volt-ohm meter prior to working with any electrical connections or components. Surge Protection 3. Observe proper wire colors while making electrical connections. Many electronic controls are polarity sensitive. Components damaged by improper electrical installation are not covered by warranty. Microprocessor-based and solid state controls are vulnerable to damage from voltage and amperage fluctuations in the power supply. All sensitive control components should be protected by a suitable commercial-grade surge protection device. 4. Provide an external surge suppressor capable of maintaining system integrity. If any of the original wire as supplied with the heater must be replaced, it must be replaced with 105°C wire or its equivalent. 5. Provide overload protection and a disconnect means for equipment serviceability as required by local and state code. Check the Power Source 6. Install heater controls, thermostats, or building management systems in accordance with the applicable manufacturer’s instructions. WARNING: Using a volt-ohm meter (VOM), check the following voltages at the terminal block inside the unit. Make sure proper polarity is followed and house ground is proven. 7. Conduit should not be used as the ground. There must be a solidly wired ground. NOTE: A grounding electrode conductor shall be used to connect the equipment grounding conductors, the equipment enclosures, and the grounded service conductor to the grounding electrode. 19 Fig. 14: Single Stage and 2-Stage Tankstat Electrical Connections—Domestic Hot Water 1. For Pool and Closed Loop Water Source Heat Pump applications, your heater should be configured to operate in an ON/OFF firing mode. This means that you will connect a single-pole control to stage one of stage selector (Terminals 4 & 5). Then jumper the remaining firing stages. For example, if your heater is a 162, you will jumper stage two. Then your heater will either be on at full fire, or it will be off. DANGER—SHOCK HAZARD: Make sure electrical power to the heater is disconnected to avoid potential serious injury or damage to components. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. NOTE: Minimum 18 AWG, 105°C, stranded wire must be used for all low voltage (less than 30 volts) external connections to the unit. Solid conductors should not be used because they can cause excessive tension on contact points. Install conduit as appropriate. All high voltage wires must be the same size (105°C, stranded wire) as the ones on the unit or larger. 2. For multi-stage controller connections, connect each stage of the control to the corresponding stage selector terminal block in the heater. Stage 1 of the heater to stage 1 of the control. Stage 2 of the heater to stage 2 of the control, and so on. Set the operating control at the setpoint in which you want the heater to maintain. Ensure that the sensing bulb of the control is at the point in the system that will best maintain the temperature you want. For example, when you are heating a tank of water, you want the operating control sensor bulb in the tank. Installer action is required to electrically enable your Hi Delta heater to operate after making the power connections. You must make a connection on Terminal Block #3 for temperature control connections. This will be done based on the controller option selected with your heater order. Consult the wiring diagram shipped with the heater in the instruction packet. The Stage 1 connections are for the remote tank control through the heaters 24 volt transformer. DO NOT attach line voltage to the Stage 1 connection. Before starting heater, check to ensure proper voltage to heater and pump. 20 Venting SINGLE STAGE TANKSTAT General CAUTION: Proper installation of flue venting is critical for the safe and efficient operation of the heater. Definition of Appliance Categories Heaters are divided into four categories based on the pressure produced in the exhaust and the likelihood of condensate production in the vent. STAGE 1 CONNECTION Category I. A heater which operates with a non-positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent. ATTACH STAGE 1 CONNECTIONS ON HEATER TO THE SINGLE STAGE TANKSTAT AS SHOWN IN THE DIAGRAM ABOVE. Category II. A heater which operates with a non-positive vent static pressure and with a vent gas temperature that may cause excessive condensate production in the vent. Fig. 15: Single Stage Tankstat Category III. A heater which operates with a positive vent pressure and with a vent gas temperature that avoids excessive condensate production in the vent. 2-STAGE TANKSTAT Category IV. A heater which operates with a positive vent pressure and with a vent gas temperature that may cause excessive condensate production in the vent. STAGE 1 CONNECTION See Table H for appliance category requirements for the Hi Delta. STAGE 2 CONNECTION OR STAGE 1 CONNECTION OF HEATER 2 NOTE: For additional information on appliance categorization, see appropriate ANSI Z21 Standard and the NFGC (U.S.), or B149 (Canada), or applicable provisions of local building codes. ATTACH STAGE 1 CONNECTIONS ON HEATER TO STAGE 1 CONNECTION ON TANKSTAT. ATTACH STAGE 2 CONNECTIONS OR STAGE 1 CONNECTION OF HEATER 2 TO STAGE 2 CONNECTIONON TANKSTAT AS SHOWN IN THE DIAGRAM. Determination of Appliance Category for Venting Purposes and Venting Arrangements Fig. 16: 2-Stage Tankstat Heater must be electrically grounded in accordance with NEC and C22.1(in Canada). WARNING: Contact the manufacturer of the vent material if there is any question about the appliance categorization and suitability of a vent material for application on a Category III or IV vent system. Using improper venting materials can result in personal injury, death or property damage. NOTES: 1. Field installed ground to inside of junction box. 2. If any of the original wire as supplied with the heater must be replaced, it must be replaced with 105°C wire or its equivalent. 21 Combustion Air Supply From Inside Building (Non-Direct Venting) From Outside Building (Direct Venting) Exhaust Configuration Venting Category Certified Appliance Material Vertical Natural Draft Venting I Type B or and Category I Venting System* Horizontal Thru-wall Venting III Stainless Steel (Gas Tight) Vertical Venting I Type B or and Category I Venting System* Horizontal Thru-wall Venting III Stainless Steel (Gas Tight) Combustion Air Inlet Material Galvanized Steel PVC ABS CPVC *As defined in the latest edition of the NFGC, or in Canada, the B149. Table H: Venting Category Requirements Barometric Damper Vent Terminal Location A barometric damper may be required when vent heights exceed 25 feet or when the draft is greater than -0.08 in. WC. In these installations, a barometric damper (single acting) is recommended. NOTE: During winter months check the vent cap and make sure no blockage occurs from build up of snow. Condensate can freeze on the vent cap. Frozen condensate on the vent cap can result in a blocked flue condition. The damper should be installed NO CLOSER than 18 in. from the discharge of the unit and no closer than 18 in. from a combustible ceiling. The damper can be installed in horizontal or vertical runs of vent pipe as necessary. Installation in a bull-head tee is acceptable as shown in the NFGC. General Give special attention to the location of the vent termination to avoid possibility of property damage or personal injury. The weights on the damper should be adjusted per the damper manufacturer’s instructions for proper operation. a) Gases may form a white vapor plume in winter. The plume could obstruct a window view if the termination is installed in close proximity to windows. Support of Vent Stack b) Prevailing winds could cause freezing of condensate and water/ice build-up on building, plants or roof. The weight of the vent stack or chimney must not rest on the heater vent connection. Support must be provided in compliance with applicable codes. The vent should also be supported to maintain proper clearances from combustible materials. c) The bottom of the vent terminal and the air intake shall be located at least 12 in. above grade. d) Un-insulated single-wall metal vent pipe shall not be used outdoors on cold climates for venting gas utilization equipment. Use insulated vent pipe spacers where the vent passes through combustible roofs and walls. e) Through-the-wall vents for Category II and IV appliances and non-categorized condensing appliances shall not terminate over public walkways or 22 Fig. 17: Minimum Clearances from Vent/Air Inlet Terminations – Indoor and Outdoor Installations 1 1 2 t TT * 2 U.S. Installations Canadian Installations A Clearance above grade, veranda, porch, deck, or balcony 1 ft (30 cm) 1 ft (30 cm) B Clearance to window or door that may be opened 4 ft (1.2m) below or to side of opening; 1 foot (30 cm) above opening 3 ft (91 cm) C Clearance to permanently closed window * * D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft (61cm) from the centerline of the terminal 5 ft (1.5m) * E Clearance to unventilated soffit * * F Clearance to outside corner * * G Clearance to inside corner 6 ft (1.83m) * H Clearance to each side of center line extended above meter/regulator assembly * 3 ft (91 cm) within a height 15 ft above the meter/regulator assembly I Clearance to service regulator vent outlet * 6 ft (1.83m) J Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 4 ft (1.2m) below or to side of opening; 1 ft (30 cm) above opening 3 ft (91 cm) K Clearance to mechanical air supply inlet 3 ft (91 cm) above if within 10 ft (3m) horizontally 6 ft (1.83m) L Clearance above paved sidewalk or paved driveway located on public property 7 ft (2.13m) 7 ft (2.13m) t M Clearance under veranda, porch, deck or balcony * 12 in. (30 cm) TT In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Code In accordance with the current CAN/CGA-B149 Installation Codes Vent terminal shall not terminate directly above sidewalk or paved driveway located between 2 single family dwellings that serves both dwellings Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor and top of terminal and underside of veranda, porch, deck or balcony is greater than 1 ft (30cm) Clearances in accordance with local installation codes and the requirements of the gas supplier Table I: Vent/Air Inlet Termination Clearances 23 f) over an area where condensate or vapor could create a nuisance or hazard or could be detrimental to the operation of regulators, relief valves, or other equipment. Where local experience indicates that condensate is a problem with Category I and III appliances, this provision shall also apply. g) The vent terminal of a direct vent appliance with an input over 50,000 Btu per hour shall require a 12-inch vent terminal clearance. Locate and guard vent termination to prevent accidental contact by people or pets. i) h) Terminate vent at least one (1) foot above grade, including normal snow line. Multiple direct vent installations require a four (4) foot clearance between vent caps. g) DO NOT terminate vent in window well, stairwell, alcove, courtyard or other recessed area, unless previously approved by local authority. Canada Installations h) DO NOT terminate above any door, window, or gravity air intake. Condensate can freeze, causing ice formations. A vent shall not terminate: i) j) Refer to latest edition of CAN/CGA-B149. a) Directly above a paved sidewalk or driveway which is located between two single family dwellings and serves both dwellings Locate or guard vent to prevent condensate from damaging exterior finishes. Use a 2’ x 2’ rust resistant sheet metal backing plate against brick or masonry surfaces. b) Less than 7 ft.(2.13m)above a paved sidewalk or paved driveway located on public property DO NOT extend exposed vent pipe outside of building. Condensate could freeze and block vent pipe. c) Within 6 ft(1.8m) of a mechanical air supply inlet to any building d) Above a meter/regulator assembly within 3 ft(900mm) horizontally of the vertical centre-line of the regulator US Installations Refer to latest edition of NFGC. e) Within 6 ft.(1.8m) of any gas service regulator vent outlet Vent termination requirements are as follows: a) Vent must terminate at least four (4) feet below, four (4) feet horizontally, or one (1) foot above any door, window or gravity air inlet to the building. f) Less than 1 ft.(300mm) above grade level g) Within the 3 ft.(1m) of a window or door which can be opened in any building, any non-mechanical air supply inlet to any building or the combustion air inlet of any other appliance b) The vent must not be less than seven (7) feet above grade when located adjacent to public walkways. h) Underneath a verandah, porch or deck, unless c) Terminate vent at least three (3) feet above any forced air inlet located within ten (10) feet. (i) the verandah, porch or deck is fully open on a minimum of two sides beneath the floor, and d) Vent must terminate at least four (4) feet horizontally, and in no case above or below unless four (4) feet horizontal distance is maintained, from electric meters, gas meters, regulators, and relief equipment. (ii) the distance between the top of the vent termination and the underside of the verandah, porch or deck is greater than 1 ft (30 cm). e) Terminate vent at least six (6) feet away from adjacent walls. f) DO NOT terminate vent closer than five (5) feet below roof overhang. 24 Venting Installation Tips on, Venting of Equipment, of the latest edition of NFGC, or in Canada, B149 Installation Code for Gas Burning Appliances and Equipment, or applicable provisions of local building codes. Support piping: · · · horizontal runs- at least every five (5) feet. vertical runs - use braces: under or near elbows 10 FEET OR LESS Follow items listed below to avoid personal injury or property damage. · · · · 2' MIN. 2' MIN. Cut nonmetallic intake pipe with fine-toothed hacksaw. Do not use nonmetallic intake pipe or fittings that are cracked or damaged. Do not use nonmetallic intake fittings if they are cut or altered. Do not drill holes, or use screws or rivets, in nonmetallic intake pipe or fittings. To make metallic vent joints: · · VENT CAP VENT PIPE Do not install seams of vent pipe on bottom of runs. 100% Seal all joints and seams with high temperature silicone sealant. COMBUSTION AIR FILTER WARNING: Examine the venting system at least once a year. Check all joints and vent pipe connections for tightness, corrosion or deterioration. NOTE: The words "Flue Exhaust", "Flue" and "Exhaust Vent" are used interchangeably. BOILER UNIT Venting Configurations For heaters connected to gas vents or chimneys, vent installations shall be in accordance with the section Model No. Appliance Category Certified Venting Material Fig. 18: Natural Draft Vertical Venting (Category I) Minimum Recommended Vent Size (inches) 122 162 202 242 Min./Max. Venting Length without Barometric Damper (feet)** 4 I Type B or Equivalent 5 322 5/25 6 **Vent lengths are based on a lateral length of 2 feet. Refer to the latest edition of the NFGC for further details. (ANSI Z223.1) Table J: Natural Draft Vertical Venting 25 Natural Draft Vertical Venting System Installation CAUTION: Listed vent cap terminal must be used and sized adequately to evacuate the flue products from the heaters. Natural draft venting uses the natural buoyancy of the heated flue products to create a thermal driving head that expels the exhaust gases from the flue. The negative draft must be within the range of -.01 in. to -.08 in. WC as measured 12 in. from the appliance flue outlet to ensure proper operation. Vent material must be listed by a nationally recognized test agency. Natural Draft Vertical Venting with Common Venting System, Category I Appliance Only Manifolds that connect more than one heater to a common chimney must be sized to handle the combined load. Consult available guides for proper sizing of the manifold and the chimney. At no time should the area of the vent be less than the area of the largest heater exhaust outlet. The maximum and minimum venting length for Category I appliance shall be determined per the latest edition of the NFGC (U.S.) or B149 Installation Code (Canada). The diameter of vent flue pipe should be sized according to Part 11 of the latest edition of the NFGC (U.S.) and part 7 and appendix B of the B149 Installation Code (Canada). The minimum flue pipe diameter for conventional negative draft venting using double-wall B type vent is 4” for 122, 5” for 162, 202 and 242, 6” for 322. WARNING: Vent connectors serving appliances vented by natural draft shall not be connected into any portion of mechanical draft systems operating under a positive pressure. CAUTION: Vent connectors for natural draft venting systems must be type “B” vent or better. NOTE: Vent Adapter will have to be used to connect B vent to the unit. Common venting systems may be too large when an existing unit is removed. At the time of removal of an existing appliance, the following steps must be followed with each appliance remaining connected to the common venting system placed in operation, while the other appliances remaining connected to the common venting system are not in operation. The connection from the appliance vent to the stack must be as direct as possible and shall be the same diameter as, or larger than the vent outlet. The horizontal breaching of a vent must have an upward slope of not less than 1/4 inch per linear foot from the heater to the vent terminal. The horizontal portions of the vent shall also be supported for the design and weight of the material employed to maintain clearances and to prevent physical damage or separation of joints. a) Seal any unused opening in the common venting system. Natural Draft Vertical Vent Termination b) Visually inspect the venting system for proper size and horizontal pitch and determine there is no blockage or restriction, leakage, corrosion or other unsafe condition. The vent terminal should be vertical and should terminate outside the building at least two (2) feet above the highest point of the roof that is within 10 feet. The vent cap should have a minimum clearance of four (4) feet horizontally from and in no case above or below (unless a four (4) foot horizontal distance is maintained) electric meters, gas meters, regulators and relief equipment. The distance of the vent terminal from adjacent public walkways, adjacent buildings, open windows and building openings must be consistent with the NFGC, or in Canada, the B149 Installation Code for Gas Burning Appliances and Equipment. Gas vents supported only by flashing and extended above the roof more than five feet should be securely guyed or braced to withstand snow and wind loads. c) Insofar as is practical, close all building doors and windows and all doors between the space in which the appliances remaining connected to the common venting system are located and other spaces of the building. Turn on clothes dryers and any appliance not connected to the common vent system. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate summer exhaust fan. Close fireplace dampers. d) Place in operation the appliances being inspected. Follow the manufacturers instructions for lighting 26 12" MIN INSULATED EXHAUST VENTING FLUE EXHAUST VENT CAP COMBUSTION AIR FILTER 12" MIN BOILER UNIT Fig. 19: Horizontal Thru-Wall Venting (Category III) each appliance. Adjust thermostat so appliance will operate continuously. g) Any improper operation of the common venting system should be corrected so that the installation conforms with the latest edition of the NFGC (US) and the B149 Installation Code (Canada). When re-sizing any portion of the common venting system, the common venting system should be re-sized to approach the minimum size as determined using the appropriate tables in Appendix G in the NFGC (US) and Appendix B of the B149 Installation Code (Canada). e) Check the pressure at a pressure tap located 12 in. above the bottom joint of the first vertical vent pipe. Pressure should be anywhere between -.01 to -.08 in. WC. f) After it has been determined that each appliance remaining connected to the common venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and other gas burning appliances to their previous conditions of use. Model No. Appliance Category Certified Venting Material Vent Size (inches) 122 162 202 242 Max. Venting Length (feet) 4 III Stainless Steel (Gas Tight) 5 322 70 Subtract 10 ft per elbow, maximum three elbows 6 Table K: Horizontal Thru-Wall Venting (Category III) 27 Horizontal Thru-wall Venting System (Category III) Installation Horizontal Thru-wall Direct Vent Termination These installations utilize the heater-mounted blower to vent the combustion products to the outdoors. Combustion air is taken from inside the room and the vent is installed horizontally through the wall to the outdoors. Adequate combustion and ventilation air must be supplied to the mechanical room in accordance with the NFGC or, in Canada, the B149 Installation Code. The flue exhaust direct vent cap MUST be mounted on the exterior of the building. The direct vent cap cannot be installed in a well or below grade. The direct vent cap must be installed at least one (1) foot above ground level and above normal snow levels. The Raypak supplied flue exhaust direct vent cap must be utilized. WARNING: No substitutions of flue pipe or vent cap material are allowed. Such substitutions would jeopardize the safety and health of inhabitants. The total length of the horizontal thru-wall exhaust vent system should not exceed seventy (70) feet in length. If horizontal run exceeds 70 feet, an appropriately sized extractor must be used. To maintain proper operation pressure reading must be between -.01 to .08 in. WC as measured 12 in. from the appliance flue outlet. Each elbow used is equal to ten (10) feet of straight pipe. This will allow installation in one of the four following combinations. · · · · The Stainless Steel direct vent cap must be furnished by the heater manufacturer in accordance with its listing. Use only the special gas vent pipes listed for use with category III gas burning heaters, such as the stainless steel vent by Heat Fab Inc (800-772-0739), Protech Systems, Inc. (800-766-3473) or Z-Flex (800-6545600). Pipe joints must be positively sealed. Follow carefully the vent manufacturers installation instructions. 70’ of straight flue pipe. 60' of straight flue pipe and one elbow. 50' of straight flue pipe and two elbows. 40' of straight pipe and three elbows. The vent cap is not considered in the overall length of the venting system. The vent must be installed to prevent the flue gas leakage. Care must be taken during assembly to ensure that all joints are sealed properly and are airtight. The vent must be installed to prevent the potential accumulation of condensate in the vent pipes. It is recommended that: a) The vent be installed with a slight downward slope of not more than 1/4" per foot of horizontal run to the vent terminal. b) The vent be insulated through the length of the horizontal run. For appliances installed in extreme cold climate, it is recommended that: a) The vent be installed with a slight upward slope of not more than 1/4" per foot of horizontal run to the vent terminal. In this case, an approved condensate trap must be installed per applicable codes. b) The vent be insulated through the length of the horizontal run. 28 12" VENT PIPE VENT CAP INTAKE VENT 36" MIN. INTAKE VENT COMBUSTION AIR FILTER 6" 12" MIN. BOILER UNIT Fig. 20: Direct Vent Horizontal Thru-Wall Venting (Category III) Model No. Appliance Category Certified Venting Material 122 162 202 242 322 Vent Size (inches) 4 III Stainless Steel (Gas Tight) 5 6 Max. Venting Length (feet) Combustion Air Intake Pipe Material 40 Subtract 10 ft per elbow, Max. two elbows Galvanized Steel PVC ABS CPVC Table L: Horizontal Thru-Wall Venting 29 Air Inlet Size (inches) Max. Air Intake Length (feet) 5 40 Subtract 10 ft per elbow, Max. two elbows Horizontal Thru-wall Direct Vent System (Category III) Installation Horizontal Thru-wall Direct Vent Termination These installations utilize the heater mounted blower to draw combustion air from outdoors and vent combustion products to the outdoors. The flue exhaust direct vent cap MUST be mounted on the exterior of the building. The direct vent cap cannot be installed in a well or below grade. The direct vent cap must be installed at least one (1) foot above ground level and above normal snow levels. The total length of the thru-wall exhaust vent cannot exceed forty (40) feet in length for the flue outlet. Each elbow used is equal to ten (10) feet of straight pipe. This will allow installation in one of the three following combinations. Multiple direct vent caps MUST NOT be installed with one combustion air inlet directly above a direct vent cap. This vertical spacing would allow the flue products from the direct vent cap to be pulled into the combustion air intake installed above. This type of installation can cause non warrantable problems with components and poor operation of the unit due to the recirculation of flue products. Multiple direct vent caps should be installed in the same horizontal plane with a three (3) foot clearance from the side of one vent cap to the side of the adjacent vent cap(s). · 40’ of straight flue pipe. · 30' of straight flue pipe and one elbow. · 20' of straight flue pipe and two elbows. The total length air supply pipe cannot exceed forty (40) feet in length for the combustion air inlet. Each elbow used is equal to ten (10) feet of straight pipe. This will allow installation in one of the three following combinations. Combustion air supplied from outdoors must be free of particulate and chemical contaminants. To avoid a blocked flue condition, keep the vent cap clear of snow, ice, leaves, debris, etc. · 40’ of straight combustion air pipe · 30' of straight combustion air pipe and one elbow. · 20' of straight combustion air pipe and two elbows. WARNING: No substitutions of flue pipe or vent cap material are allowed. Such substitutions would jeopardize the safety and health of inhabitants. The flue exhaust direct vent cap is not considered in the overall length of the venting system. Care must be taken during assembly that all joints are sealed properly and are airtight. The Stainless Steel flue exhaust direct vent cap must be furnished by the heater manufacturer in accordance with its listing. Use only the special gas vent pipes listed for use with category III gas burning heaters, such as the stainless steel vent by Heat Fab Inc (800-772-0739), Protech Systems, Inc. (800-7663473) or Z-Flex (800-654-5600). Pipe joints must be positively sealed. Follow carefully the vent manufacturers installation instructions. The vent must be installed to prevent the potential accumulation of condensate in the vent pipes. It is recommended that: a) The vent be installed with a slight downward slope of not more than 1/4" per foot of horizontal run to the vent terminal. b) The vent be insulated through the length of the horizontal run. For appliances installed in extreme cold climate, it is recommended that: a) The vent be installed with a slight upward slope of not more than 1/4" per foot of horizontal run to the vent terminal. In this case, an approved condensate trap must be installed per applicable codes. b) The vent be insulated through the length of the horizontal run. 30 36" VENT CAP 36" MIN. 12" MIN. VENT PIPE INTAKE VENT COMBUSTION AIR FILTER BOILER UNIT Fig. 21: Direct Vent—Vertical Venting (Category I) Model No. Appliance Category Certified Venting Material 122 162 202 242 322 Vent Size (inches) Min./Max. Vertical Venting Height (feet) Combustion Air Intake Pipe Material 5/25 Galvanized Steel PVC ABS CPVC Air Inlet Size (inches) Max. Air Intake Length (feet) 5 40 Subtract 10 ft per elbow, Max. two elbows 4 I Type B Equivalent 5 6 Table M: Vertical Venting 31 Vertical Direct Vent System Installation blockage from snow. The vent cap must have a minimum 3 foot clearance from the air inlet opening. These installations utilize the heater mounted blower to draw combustion air from outdoors and uses the natural buoyancy of the heated flue products to create a thermal driving head that expels the exhaust gases from the flue. The negative draft must be within the range of -0.01 to -0.08 in. WC as measured 12 in. from the appliance outlet to ensure proper operation. The vent material must be in accordance with the above instructions for vent materials. Vent material must be listed by a nationally recognized test agency. Outdoor Installation Outdoor models are self-venting when installed with the factory-supplied restricted direct vent cap and require no additional vent piping. This special vent cap is provided with the heater in accordance with CSA requirements. It must be installed directly on the heater. See Section B for correct clearances. Care must be taken when locating the outdoor unit because the flue gases discharged from the vent hood can condense as they leave the hood. Improper location can result in damage to adjacent structures or building finish. For maximum efficiency and safety, the following precautions must be observed: The maximum and minimum venting length for Category I appliance shall be determined per the latest edition of the NFGC (U.S.) and B149 Installation Code (Canada). a) Outdoor models must be installed outdoors and must use the outdoor vent hood supplied by the manufacturer. The connection from the appliance exhaust vent to the stack must be as direct as possible and should be the same as or larger than the vent outlet. The vent must be installed to prevent accumulation of condensate and, where necessary, have means provided for drainage of condensate. The horizontal breaching of a vent must have an upward slope of not less than 1/4 inch per linear foot from the heater to the vent terminal. The horizontal portions of the vent shall also be supported for the design and weight of the material employed to maintain clearances and to prevent physical damage or separation of joints. b) Periodically check venting system. The heater’s venting areas must never be obstructed in any way and minimum clearances must be observed to prevent restriction of combustion and ventilation air. Keep area clear and free of combustible and flammable materials. c) Do not locate adjacent to any window, door walkway, or gravity air intake. The vent must be located a minimum of four (4) feet horizontally, or four (4) feet below, or one (1) foot above such areas. Vertical Direct Vent Termination The exhaust vent terminal should be vertical and should terminate outside the building at least two (2) feet above the highest point of the roof within 10 feet. The vent cap should have a minimum clearance of four (4) feet horizontally from and in no case above or below (unless a four (4) foot horizontal distance is maintained) electric meters, gas meters, regulators and relief equipment. The distance of the vent terminal from adjacent public walkways, adjacent buildings, open windows and building openings must be consistent with the NFGC, or in Canada, the B149. Installation Code. Gas vents supported only by flashing and extended above the roof more than five feet should be securely guyed or braced to withstand snow and wind loads. d) Install above grade level and above normal snow levels. e) Vent terminal must be at least 3 feet above any forced air inlet located within 10 feet. f) Adjacent brick or masonry surfaces must be protected with a rust-resistant sheet metal plate. g) Multiple Outdoor Vent installations require a four (4) feet clearance between vent caps. NOTE: Condensate can freeze on the vent cap. Frozen condensate on the vent cap can result in a blocked flue condition. The vertical direct vent cap is designed for roof top mounting only. The air inlet opening MUST be installed one (1) foot above the roof line or above normal snow levels that might obstruct combustion air flow. This dimension is critical to the correct operation of the heater and venting system and reduces the chance of The restricted vent cap must be furnished by the heater manufacturer in accordance with its listing. An outdoor air filter, supplied by the manufacturer is mounted on the heater. 32 CONTROLS WARNING: Installation, adjustment and service of heater controls including timing of various operating functions must be performed by a qualified installer, service agency or the gas supplier. Failure to do so may result in control damage, heater malfunction, property damage, personal injury, or death. WARNING: Turn off the power to the heater before installation, adjustment or service of the heater controls. Failure to do so may result in heater malfunction, property damage, personal injury, or death. Fig. 22: Ignition Module High Limit (Manual Reset) The heater is equipped with a manual reset high limit temperature device. Push the reset button and adjust the setting to 30° F or 40° F above desired operating temperature. CAUTION: This appliance has provisions to be connected to more than one (1) supply source. To reduce the risk of electric shock, disconnect all such connections before servicing. CAUTION: Risk of electric shock. More than one (1) disconnect switch may be required to deenergize the equipment before servicing. Ignition Control Module The interrupted proved ignition device conserves energy. When additional heat is needed, the combustion air blower starts to purge all air from the combustion chamber for about 15 seconds. On proof of air flow, the air proving switch closes and the igniter is energized, eliminating the fuel costs of maintaining a constant pilot. Fig. 23: Manual Reset High Limit To ensure safe operation, the gas valve cannot open until the pilot igniter is verified. The 100% igniter safety is an electronic device which closes the main gas valve within 8/10 of a second whenever the flame is interrupted. Main burner is automatically lit when the device is powered and pre-purged. Unit performs its own safety check and opens the main valve only after the igniter is proven to be capable of ignition. 33 Flow Switch Low Water Cut Off (Optional) Dual-purpose control shuts off heater in case of pump failure or low water flow. Mounted and wired in series with the main gas valve. Check with Manufacturer for proper paddle size. Utilize correct paddle size for proper operation. The low water cut off automatically shuts down the burner whenever water level drops below the level of the sensing probe. A 3-second time delay prevents premature lockout due to temporary conditions such as power fluctuations or air pockets. NOTE: Flow switch will not operate if flow is less than 20 gpm. Fig. 25: Low Water Cut Off Fig. 24: Flow Switch 34 WIRING DIAGRAM—MODELS 122–322 35 PRE-START-UP 4. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it, call a qualified service technician. Forced or attempted repair may result in a fire or explosion. Filling System-Heating Heaters Fill system with water. Purge all air from the system using purge valve sequence. After system is purged of air, lower system pressure. Open valves for normal system operation, fill system through feed pressure. Manually open air vent on the compression tank until water appears, then close vent. 5. Do not use this appliance if any part has been under water, immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Domestic Hotwater Heaters 6. Check around unit for debris and remove combustible products, i.e. gasoline, etc. Purge all air from system before lighting heater. This can be normally be accomplished by opening a downstream valve. Pre-Start-Up Check 1. Verify heater is filled with water. Inspect Venting System: 2. Check system piping for leaks. If found, repair immediately. 1. Check all vent pipe connections and flue pipe material. 3. Vent air from system. Air in system can interfere with water circulation. 2. Ensure vent terminations are installed per code and are clear of all debris or blockage. 4. Purge air from gas line up to heater. For Your Safety Read Before Lighting INITIAL START-UP Tools Needed WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • • • • • • • 1. This appliance does have an intermittent pilot. It is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot or burner by hand. One 12-0-12, 24” scale manometer Two 6-0-6, 12” scale manometers 7/16” open end wrench 1/2” open end wrench Screwdriver Volt meter 3/16” Allen wrench 2. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. Preparation for Start-Up 3. WHAT TO DO IF YOU SMELL GAS Check Power Supply • • With volt meter at incoming power check voltage between: • • WARNING: Do not turn on gas at this time. Do not try to light any appliance. Do not touch any electrical switch; do not use any telephone in your building. Immediately call your gas supplier from a neighbor's telephone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. Hot - Common (~120 VAC) Hot - Ground (~120 VAC) Common - Ground (< 1 VAC) 36 6. Reconnect fan pressure switch tubing to original position. WARNING: If Common - Ground is > 1 VAC, STOP: Contact electrician to correct ground failure. Failure to do this may burn out 120V-24V transformer, or may cause other safety control damage or failure. Main Burner Adjustment 1. Turn off unit. Attach Manometers to Measure Pressures • • • 2. Open manual firing valve. 3. Turn on the unit, wait 15 seconds, and the igniter should glow. Sight glass to check igniter at both ends of the heater. Gas valve should be open after 45 seconds. Attach 24" scale manometer to the first main gas shut-off valve pressure tapping. Attach one 12" scale manometer to the manifold gas pressure tapping. (See gas valve detail on page 7.) Attach one 12" scale manometer to — Pull rubber tube from air pressure switch off the aluminum tubing and connect the manometer using a tee. 4. If burner does not light on first trial. It will retry, up to 3 times. 5. Main burner ignition – check manifold gas pressure at gas valve manifold pressure tap. (See gas valve detail page 7) This should read 3.5 ± 0.1 in. WC for natural gas or 10.5 ± 0.1 in. WC for LP gas. Turn Off Main Gas Valve; Check the Gas Supply Pressure 6. If the pressure reading differs by more than ± 0.1 in. WC. Remove manifold adjustment screw cover off the pressure regulator on the gas valve, adjust main burner manifold pressure. Replace the manifold adjustment screw cap on the gas valve. 1. Slowly turn on main gas shut-off valve. 2. Read the gas supply pressure from the manometer; minimum supply pressure is 5” W.C., recommended supply is 7” W.C. for natural gas (minimum 11” W.C. for LP gas). Your Hi Delta is tuned in! 3. If pressure is > 14" W.C., turn off the valve. Safety Inspection 4. Check if the service regulator is installed and/or adjust the service regulator. • • • Start-Up • Blower Adjustment • • • • 1. Disconnect fan pressure switch tubing at plenum and connect manometer using a tee. 2. Close all manual firing valves. 3. Turn power on. 4. Check manometers attached to fan pressure switch. The readings should be : 0.5 ± 0.1 in. WC for models 102 and 122. 0.7 ± 0.1 in. WC for models 202, 242, 322. If not, adjust the air shutter on the blower to attain the correct value. (See air shutter adjustment page 7). • • 5. Turn power off. 37 Replace main gas manifold adjustment screw cap. Check all thermostats and high limit settings. During the following safety checks leave manometers hooked up, check and record. If other gas fired equipment are in the room and on same gas main check all pressures on the Hi Delta with all other equipment running. Check thermostats for ON/OFF operation. Check High limits for ON/OFF operation. While in operation, check flow switch operation Check the low gas pressure switches (For proper adjustment, if available, use the attached manometers to set pressure. The scales on the switch are approximate only); Low gas pressure switch must be set at 5 in. WC for natural gas and 10 in. WC for LP gas. High gas pressure switch (optional) at 1 in. WC above manifold pressure. Insert ignition control lockout tests as safety check. Follow-Up • • · · Safety checks must be recorded as performed. Turn unit on. 10. To restart system, follow lighting instructions in the Operation section. After main burner ignition: • • • • • off immediately. Wait 5 minutes. Reconnect combustion air pressure switch, burner should reignite after pre-purge time delay. Check Manometer for proper reading. Cycle unit several times and recheck readings Re-analyze with unit running record or print results. Remove all Manometers and replace hose, remove jumper, replace all gas pressure caps. Check for gas leaks one more time. 11. High limit control set to design temperature requirements of system? For multiple zones: flow adjusted as required in each zone? 12. Heater cycled with thermostat? Raise to highest setting and verify heater goes through normal start-up cycle. Reduce to lowest setting and verify heater goes off. POST START-UP CHECK Check off steps as completed: 13. Observed several operating cycles for proper operation? 1. Heater and heat distribution units or storage tank filled with water? 14. Set room thermostat or tankstat to desired temperature? 2. Automatic air vent, if used, open two full turns during venting procedure? 15. Reviewed all instructions shipped with this heater with owner or maintenance person, returned to envelope and given to owner or placed in pocket inside front panel on heater? 3. Air purged from system? 4. Air purged from gas piping? Piping checked for leaks? OPERATION 5. Followed start-up procedure for proper start-up? Operating Instructions 6. Is burner flame visible? Lighting Instructions 7. Test safety controls: If heater is equipped with a low water cut-off or additional safety controls, test for operation as outlined by manufacturer. Burner should be operating and should go off when controls are tested. When safety devices are restored, burners should reignite after pre-purge time delay. 1. STOP! Read the safety information first. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the burner. Do Not try to light the burner by hand. 8. Test limit control: While burner is operating, move indicator on high limit control below actual heater water temperature. Burner should go off while blower and circulator continue to operate. Raise setting on limit control above heater water temperature and burner should reignite after pre-purge time delay. 5. Remove upper front panel. 6. Turn on main manual gas valve. 7. Wait five (5) minutes to clear out any gas. Then smell for gas, especially near the floor. If you then smell gas. STOP! Follow the steps in the safety information on the front cover. If you do not smell gas, go to next step. 9. Test ignition system safety device: · · · Turn on manual gas valve. Turn power on. Set thermostat to call for heat. When the unit is in operation. Disconnect combustion air blower pressure switch, burner should go 38 Yearly (Beginning of each heating season): 8. Turn on all electric power to the appliance. 9. Set thermostat to desired setting. The appliance will operate. The igniter will glow after the prepurge time delay (15 seconds). After igniter reaches temperature (45 seconds) the main valve will open. System will try for ignition three (3) times. If ignition is not sensed, lockout will commence. 1. Annual service call by qualified service agency. 2. Visually check top of vent for soot. Call service person to clean. Some sediment at bottom of vent is normal. 3. Visually inspect venting system for proper function, deterioration or leakage. 10. If the appliance will not operate, follow the instruction "To Turn Off Gas To Appliance", and call your service technician or gas supplier. 4. Check that heater area is free from combustible materials, gasoline, and other flammable vapors and liquids. 11. Replace access panel. To Turn Off Gas To Appliance 5. Check for and remove any obstruction to the flow of combustion or ventilation air to heater. 1. Set the thermostat to lowest setting. 6. Follow pre-start-up check in the Initial Start-up section. 2. Turn off all electric power to the appliance if service is to be performed. 7. Visually inspect burner flame. Should see light blue flame. Visually inspect hot surface igniter for damage, cracking or debris build-up. 3. Remove upper front panel. 4. Turn off main manual gas valve. 8. Check operation of safety devices. Refer to manufacturer’s instructions. 5. Replace access panel. If heater fails to start, check for: • • • • • 9. Follow oil-lubricating instructions on circulator. Over-oiling will damage circulator. Water-lubricated circulators do not need oiling. Loose connections, blown fuse or service switch off? High temperature limit switch set below heater water temperature? Thermostat set below room temperature? Gas not turned on at meter or heater? Incoming gas pressure less than 6 in. WC for natural gas, 11 in. WC for LP gas. 10. To avoid potential of severe burn, DO NOT REST HANDS ON OR GRASP PIPES. Use a light touch - return piping will heat up quickly. 11. Check blower and blower motor. Clean and oil as necessary. MAINTENANCE 12. Check for piping leaks around circulators, relief valves and other fittings. Repair, if found. DO NOT use petroleum based stop leak. Suggested Minimum Maintenance Schedule: Daily: 1. Check that heater area is free from combustible materials, gasoline, and other flammable vapors and liquids. Regular service by a qualified service agency and maintenance must be performed to ensure maximum heater operating efficiency. Maintenance as outlined below may be performed by the owner. 2. Check for and remove any obstruction to the flow of combustion or ventilation air to heater. 39 Monthly: Products causing contaminated combustion air: 1. Check for piping leaks around circulators, mixing valves, relief valves, and other fittings. If found, repair at once. DO NOT use petroleum-based stop leak compounds. • • • • • • • • • • • • 2. Visually inspect burner flame. 3. Visually inspect venting system for proper function, deterioration or leakage. 4. Check air vents for leakage. Quarterly: • • 1. Check relief valve. Refer to manufacturer’s instructions on valve. Areas causing contaminated combustion air: 2. Test low water cut-off, if used. Refer to manufacturer’s instructions. • • • • • • • • • • 3. Clean screen and air filter in intake. APPENDIX Inside Combustion Air Contamination: All heaters experience some condensation during start-up. The condensate from flue gas is slightly acidic. In most cases the pH level is not harmful to vents or drains. When combustion air is contaminated by vapors from products in areas listed below, the acidic levels in the condensate increase. Higher acidic levels attack many materials, including stainless steel commonly used in high efficiency systems. • • dry cleaning/laundry areas and establishments metal fabrication plants beauty shops refrigeration repair shops photo processing plants auto body shops plastic manufacturing plants urniture refinishing areas and establishments new building construction remodeling areas. Check for areas and products as listed above before installing heater. If found: • • The heater can use special corrosion-resistant nonmetallic intake vent material. You may, however, choose to use outside combustion air for one or more of these reasons: • spray cans containing chloro/fluorocarbons permanent wave solutions chlorinated waxes/cleaners chlorine-based swimming pool chemicals calcium chloride used for thawing sodium chloride used for water softening refrigerant leaks paint or varnish removers hydrochloric acid/muriatic acid cements and glues antistatic fabric softeners used in clothes dryers chloride-type bleaches, detergents, and cleaning solvents found in household laundry rooms adhesives used to fasten building products ... and other similar products. installation is in an area containing contaminants listed below which will induce acidic condensation. you want to reduce infiltration into your building through openings around windows and doors. you are using AL29-4C stainless steel vent pipe, which is more corrosion-resistant than standard metallic vent pipe. In extremely contaminated areas, this may also experience deterioration. 40 remove products permanently, OR provide outdoor combustion air. LIMITED PARTS WARRANTY COMMERCIAL BOILERS TYPE HI-DELTA SIZES 122 TO 322 MODELS H AND WH SCOPE: Raypak, Inc. (“Raypak”) warrants to the original owner that all parts of this boiler which are actually manufactured by Raypak will be free from failure under normal use and service for the specified warranty periods and subject to the conditions set forth in this Warranty. Labor charges and other costs for parts removal or reinstallation, shipping and transportation are not covered by this Warranty but are the owner’s responsibility. HEAT EXCHANGER WARRANTY: Domestic Hot Water Five (5) years from date of boiler installation. Includes copper heat exchanger with bronze and cast iron waterways. Ten (10) years from date of boiler installation. Includes only cupro nickel heat exchanger with bronze or cast iron waterways. Space Heating (Closed Loop System) Ten (10) years from date of boiler installation. Includes both cupro nickel and copper heat exchanger with bronze or cast iron waterways. Thermal Shock Warranty Twenty (20) years from date of boiler installation against “Thermal Shock” (excluded, however, if caused by boiler operation at large changes exceeding 150°F between the water temperature at intake and boiler temperature, or operating at boiler temperatures exceeding 230°F). ANY OTHER PART MANUFACTURED BY RAYPAK: One (1) Year warranty from date of boiler installation, or eighteen (18) months from date of factory shipment based on Raypak’s records, whichever comes first. SATISFACTORY PROOF OF INSTALLATION DATE, SUCH AS INSTALLER INVOICE, IS REQUIRED. THIS WARRANTY WILL BE VOID IF THE BOILER RATING PLATE IS ALTERED OR REMOVED. ADDITIONAL WARRANTY EXCLUSIONS: This warranty does not cover failures or malfunctions resulting from: 1. Failure to properly install, operate or maintain the boiler in accordance with our printed instructions provided; 2. Abuse, alteration, accident, fire, flood and the like; 3. Sediment or lime buildup, freezing, or other conditions causing inadequate water circulation; 4. High velocity flow exceeding boiler design rates; 5. Failure of connected systems devices, such as pump or controller; 6. Use of non-factory authorized accessories or other components in conjunction with the boiler system; 7. Failing to eliminate air from, or replenish water in, the connected water system; 8. Chemical contamination of combustion air or use of chemical additives to water. PARTS REPLACEMENT: Under this Warranty, Raypak will furnish a replacement for any failed part. The failed part must first be returned to Raypak if requested, with transportation charges prepaid, and all applicable warranty conditions found satisfied. The replacement part will be warranted for only the unexpired portion of the original warranty. Raypak makes no warranty whatsoever on parts not manufactured by it, but Raypak will apply any such warranty as may be provided to it by the parts manufacturer. TO MAKE WARRANTY CLAIM: Promptly notify the original installer, supplying the model and serial numbers of the unit, date of installation and description of the problem. The installer must then notify his Raypak distributor for instructions regarding the claim. If either is not available, contact Service Manager, Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 or call (805) 278-5300. In all cases proper authorization must first be received from Raypak before replacement of any part. EXCLUSIVE WARRANTY - LIMITATION OF LIABILITY: This is the only warranty given by Raypak. No one is authorized to make any other warranties on Raypak’s behalf. THIS WARRANTY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. RAYPAK’S SOLE LIABILITY AND THE SOLE REMEDY AGAINST RAYPAK WITH RESPECtTTO DEFECTIVE PARTS SHALL BE AS PROVIDED IN THIS WARRANTY. IT IS AGREED THAT RAYPAK SHALL HAVE NO LIABILITY, WHETHER UNDER THIS WARRANTY, OR IN CONTRACT, TORT, NEGLIGENCE OR OTHERWISE, FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGE, INCLUDING DAMAGE FROM WATER LEAKAGE. Some states do not allow limitations on how long an implied warranty lasts, or for the exclusion of incidental or consequential damages. So the above limitation or exclusion may not apply to you. This Limited Warranty gives you specific legal rights. You may also have other rights which may vary from state to state. We suggest that you complete the information below and retain this certificate in the event warranty service is needed. Reasonable proof of the effective date of the warranty (date of installation) must be presented, otherwise, the effective date will be based on the rate of manufacture plus thirty (30) days. _____________________________________________________ Name of Owner _____________________________________________________ Address _____________________________________________________ ______________________________________________ Name of Dealer ______________________________________________ Address ______________________________________________ _____________________________________________________ ______________________________________________ Model No. Serial No. Date of Installation:_____________________________________ Date of Initial Operation: ___________________________ CORPORATE HEADQUARTERS: RAYPAK, INC. • 2151 Eastman Avenue • Oxnard • CA 93030 •(805) 278-5300 • FAX (800) 872-9725 • www.raypak.com 41 42 43 www.raypak.com Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement