advertisement
Index
A
AC distribution box, 5-28
Address bus commands, 4-2
Address gate array (ADG), 1-7
ARC utility programs, B-3
Audit trail messages, B-7
B
BA36R StorageWorks shelf, 1-14, 2-14,
5-33
Baud rate, console terminal, B-7
Blowers, 1-14, 2-14, 5-38
boot command, A-3, B-1
Boot processor, 3-3
Booting LFU, A-2
BPD line, 3-3
build -c command, 5-7, 5-11
build command, B-1
C
Cabinet control logic (CCL) panel, 1-12,
5-32
Cabinet panels, 5-40
Cables, 5-42
Cache memory, 1-7
CD-ROM drive, 1-14, 2-14, 5-26
clear command, B-2
Commander node, 4-2
Comment (#) command, B-4
Console CD-ROM, A-2
Console commands, B-1
Console halt conditions, 4-30
continue command, B-2
Control and status register (CSR), 4-2
CPU double error halt, 4-30, 4-33
crash command, B-2
create command, B-2
D
Data bus signals, 4-3
Data interface gate arrays (DIGA), 1-7
date command, B-2
DC distribution module, 5-43
DC to DC converters, 1-7, 1-15
DECevent, 4-3
deposit command, B-2
display command, LFU, B-12
Dump file, B-6
DWLPB error log, 4-24
DWLPB PCI box, 5-36
E
EMI gasket, 5-13
Enabled (E) processor, 3-3
Environment variables
arc_enable, B-5
auto_action, B-5
boot_file, B-5
boot_osflags, B-5
boot_reset, B-6
bootdef_dev, B-5
console, B-6
cpu, B-6
cpu_enabled, B-6
cpu_primary, B-6
d_harderr, B-6
d_report, B-6
d_softerr, B-6
dump_dev, B-6
enable_audit, B-7
graphics_switch, B-7
interleave, B-7
language, B-7
Index-1
simm_callout, B-7
sys_model_num, B-7
sys_serial_num, B-7
tta0_baud, B-7
Error checking, 4-3
Error log, DECevent, 4-4
Error log header structure, 4-31
Error log size, 4-42
Event type identification, 4-7
examine command, B-2
exit command, LFU, A-10
Expander cabinet, 1-2, 5-43
F
Fatal errors, 4-30
Floppy drive , 1-14, 5-43
G
Graphics console, B-6
graphics_switch environment variable setting, B-8
grep command, 3-15
GS60E options, 1-3
H
H7056 power supply removal and replacement, 5-29
Hard error, B-6
Hose numbering, 3-5
Hoses, 1-10
I
I/O hose cable, 5-18
info 5 command, 3-15
info command, 3-14
init command, 3-13
initialize command, B-2
K
KFTHA module, 1-10
KFTHA placement, 1-5
Index-2
L
LARS number, 5-7, 5-11
LFU booting, A-2
display command, A-12
exit command, A-10
list command, A-4
update command, A-6
verify command, A-12
LFU prompt, UPD>, A-3
list command, LFU, A-4
Loadable firmware update (LFU) utility, A-1
M
Machine check 620 errors, 4-17, 4-52
Machine check 660 errors, 4-8
Machine check 670 errors, 4-30
Machine check errors, 4-6
Machine check error log, 4-42
Machine check logout frames, 4-39
Memory interleaving, 3-3 size, 3-3
Memory interleave specification, B-7
Memory module placement, 1-5 removal, 5-13 test, 3-10
Module placement rules, 1-5
MS7CC memory module, 1-8
Multiprocessor testing, 3-3
N
Node # line, 3-3
O
OCP cable, 5-24, 5-43
OCP removal, 5-24
OpenVMS event type
identification, 4-7
OSF event type identification, 4-7
P
PAL code, 4-3
Parse trees, 4-23, 4-61
Parsing errors, 4-8, 4-12
path option, A-9
PCI shelves (DWLPB-DA), 1-15
Plenum assembly, 5-38
Power rack assembly, 5-30
Power subsystem, 1-12
Power supplies, 1-12, 5-31
Processor module, 1-6, 5-2 placement, 1-5 replacement, 5-12
R
Removal and replacement procedures
AC distribution box, 5-28
BA36R StorageWorks shelf, 5-34 boot processor, 5-4 cabinet control logic (CCL) panel, 5-
32 cabinet panels and doors, 5-40
CD tray, 5-26
DWLPB, 5-36
H7056 power supply, 5-29
I/O hose cable, 5-18
KFTHA, 5-18 memory module, 5-13 operator control panel (OCP), 5-24 plenum, 5-39 power rack assembly, 5-30 power supply, 5-31 processor module, 5-2 second module, 5-8
SIMM, 5-14 terminator module, 5-12
TLSB card cage, 5-20
run command, B-3
runecu command, B-3
S
Self-test console display, 3-2
Serial console, B-6
set command, B-3
show command, B-3 show configuration command, 5-13
Show configuration display, 3-4
show device command, 5-23, 3
show simm command, 5-13
SIMM console commands, 3-13
SIMM fault, 4-12
SIMM identification, failing, 3-12
SIMMs, 1-9
Slave node, 4-2
start command, B-4
stop command, B-4
StorageWorks shelves (BA36R), 1-15
Summary error log, 4-5
Supported event types, 4-6
T
Terminating testing, 3-9
Terminator module, 1-5, 5-12
test command, 3-6, 5-23, B-4, B-6
TLEP subpacket, 4-44
TLSB system bus, 1-4, 4-2
Troubleshooting overview, 1-16
Troubleshooting tools, 1-17
TYP line, 3-3
U
update command, 5-5, 5-9, A-6
Updating firmware, A-1
V
Verification, 5-13, 5-15, 5-19, 5-23, 5-25,
5-27, 5-29, 5-31, 5-33, 5-37, 5-39
verify command, LFU, A-12
Index-3
advertisement
Related manuals
advertisement
Table of contents
- 1 Title page
- 2 Copyright
- 5 Contents
- 11 Preface
- 13 Chapter 1 Introduction
- 31 Chapter 2 Troubleshooting with LEDs
- 47 Chapter 3 Console Display and Diagnostics
- 63 Chapter 4 DECevent Error Log
- 109 Chapter 5 Removal and Replacement Procedures
- 153 Appendix A Updating Firmware
- 169 Appendix B Console Commands and Environment Variables
- 177 Index