IP Filter Protection. Delta Electronics Ethernet Communication Module DVPEN01-SL
Add to my manuals
54 Pages
advertisement
Ethernet Communication Module DVPEN01-SL
2. Check the “Default Setting” box and the “Warning” dialog box will appear. Click on “Yes” to return to default setting (in approx. 5 ~ 10 seconds), and the password will be cleared as well.
3. After the searching, all the parameters have already returned to their default settings.
6.6 IP Filter Protection
Application Setting up IP filter protection
Network requirement
(1) IP of DVPEN01-SL: 192.168.0.4
(2) Only connections to 192.168.0.7 and 172.16.0.1~172.16.0.255 are allowed.
1. See 6.1 for the connection and how to set up the communication.
2. Open the setup page and switch to “IP Filter” page.
40 DVP-PLC Application Manual
Ethernet Communication Module DVPEN01-SL
3. Check “Enable IP Filter Function” box. Enter “192.168.0.7” in No. 1 IP and “255.255.255.255” in all
“Netmask” columns.
4. Enter “192.168.0.1” in No. 2 IP and “255.255.255.0” in No.2 “Netmask” column. Click on "OK” to complete the setting. Only the equipment within the IP range can be connected.
DVP-PLC Application Manual
41
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 INTRODUCTION
- 5 Functions
- 5 Specifications
- 6 PRODUCT PROFILE & OUTLINE
- 6 Dimension
- 6 Product Profiles
- 7 LED Indicators
- 7 RJ-45 PIN Definition
- 7 INSTALLATION & WIRING
- 7 Installation
- 8 CONTROL REGISTER (CR)
- 8 Control Registers in DVPEN01-SL
- 10 Explanations on CR
- 14 Numbering of Left-Side Extension Modules
- 15 SETTING UP SOFTWARE
- 15 Setting up Communication & Searching for Modules
- 18 Basic Settings
- 20 Network Settings
- 22 Setting up E-Mails
- 24 Data Exchange
- 25 IP Filter
- 26 Static ARP Table
- 27 Setting up Password
- 28 Returning to Default Setting
- 29 Export & Import of DVPEN01-SL Files
- 30 Recording IP Address
- 31 APPLICATION EXAMPLES
- 31 Setting up IP and Communicating through WPLSoft
- 34 Connecting the PC with DVPEN01-SL through LAN
- 38 Setting up IP and Communicating through WPLSoft
- 39 Setting up Password and Clearing Password
- 41 When the Password is Lost (Returning to Default Setting by RS-232)
- 42 IP Filter Protection
- 44 Setting up Static ARP Table
- 45 Application of E-Mail
- 47 Application of Data Exchange (1)
- 49 Application of Data Exchange (2)
- 50 Application of Data Exchange (3)
- 51 Application of Modbus TCP Master (1)