3.1 Absolute Limiting Values

Any (also temporary) stress in excess of the limiting values may cause permanent damage on CPC-PP/Eco.

Parameter

Storage temperature

Operating temperature*

Supply voltage

(standard version)

Supply voltage

(EX version)

Voltage on bus connections

Voltage on bus connections (EX version)

Current across ground connection

Min Max Unit

-20 80

0

0

0

-4

-30

60

16

30

15

30

1

* Extended temperature range on demand

°C

°C

V

V

V

V

A

EMS Dr. Thomas Wünsche 15

CPC-PP User Manual

3.2 Nominal Values

Parameter

Current consumption

Supply voltage

(standard version)

Supply voltage

(EX version)

CAN controller clock frequency

Bus data rate

Min Typ Max Unit

– 40 120 mA

7

16

16

14

28

V

V

MHz kBit/s –

100

10,

20,

50,

100,

125,

250,

500,

1000 and others

– – % Throughput to

PC486/DX2-66 at CAN bitrate

125kBit/s

Throughput to

PC486/DX2-66 at CAN bitrate

1MBit/s

12,5 15 – %