SERVICE PROCEDURE RE-III
Residential Thermostat Testing
Double Element, Non-Simultaneous, Single Phase
Operation (continued).
WARNING
High voltage exposure. Use caution to avoid personal injury during this procedure.
Not Enough Hot Water (continued).
7. Check voltage across terminal L4 of upper
thermostat and terminal 1 of lower thermostat
(see illustration 11).
A) Rated voltage NOT present,
- check wire connection between thermostats.
B) Rated voltage IS present, okay, go to step 8.
8. Adjust lower thermostat to highest setting. Water temperature in
tank must be below the lower thermostat setting for this test.
9. Check voltage across terminal L4 of upper
thermostat and terminal 2 of lower thermostat (see illustration 12).
A) Rated voltage NOT present, replace lower thermostat.
B) Rated voltage IS present, thermostat is ok.
WARNING
Be sure thermostats are reset to their original temperature settings as found prior to thermostat testing
Illustration 11
Water Temperature In Tank Is Above Thermostat Setting.
1. This procedure assumes Line voltage, ECO and elements are in working
order.
2. Adjust upper and lower thermostats to the lowest setting.
3. Turn power “ON” to water heater and set multi-meter to “Volts AC”.
4. Check across terminals L4 and T2 of upper thermostat
(see illustration 8 on page 17).
A) Rated voltage IS present, replace upper thermostat.
B) Rated voltage NOT present, upper thermostat is okay. Go to step
5 below.
C) Lower than rated voltage IS present, recheck for grounded upper
element (see page 15).
5. Check across terminals L4 and 2 of lower thermostat (see illustration 12).
A) Rated voltage IS present, replace lower thermostat.
B) Rated voltage NOT present, lower thermostat is okay.
C) Lower than rated voltage IS present, recheck for grounded lower
element (see page 15).
Page 18
Illustration 12
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 12 Introduction
- 12 Tools
- 13 General Information
- 16 Sequence of Operation
- 16 Single Element Operation
- 17 Double Element, Non-Simultaneous, Single Phase
- 18 Double Element, Simultaneous, Single Phase, 4 wire Service
- 19 Double Element, Non-Simultaneous, 3 Phase
- 20 Double Element, Simultaneous, 3 Phase
- 21 Double Element, Non-Simultaneous, Single Phase, Off Peak
- 22 Troubleshooting
- 24 Line Voltage and High Limit ECO Testing
- 25 Heating Element Testing
- 26 Residential Thermostat Testing
- 26 Single Element
- 27 Double Element, Non-Simultaneous, Single Phase
- 29 Double Element, Non-Simultaneous, 3 Phase
- 31 Double Element, Simultaneous, 3 Phase
- 33 Double Element, Non-Simultaneous, Single Phase, Off Peak
- 35 Light Duty Commercial Thermostat Testing
- 35 Double Element, Non-Simultaneous, Single Phase
- 37 Double Element, Simultaneous, Single Phase