Nonlinear vector network analysis. Agilent Technologies E8364C

Add to My manuals
39 Pages

advertisement

Nonlinear vector network analysis. Agilent Technologies E8364C | Manualzz

PNA-X Series Network Analyzer

Nonlinear vector network analysis

Please refer to the Nonlinear Vector Network Analyzer brochure for more information 5989-8575EN

Pulse, antenna, mm-wave

Pulsed-RF measurements (Option 008)

This option extends the pulsed-RF measurement capability of

the PNA-X to pulse widths below 267 ns, which is the limit for

the standard wideband detection mode. The PNA-X is a complete

pulsed-RF solution with built in pulse generators and modulators,

so external test sets and pulse generators are not required.

null out unwanted spectral components, enables the internal

receiver IF gates, controls internal pulse generators (Option 025),

internal pulse modulators (Option 021 and/or 022), and external

pulse modulators, and performs optimization for measurement

sensitivity. Option 008 also includes conventional pulsed-RF

measurement software (Option H08), which can run on the

PNA-X or an external computer. The N1966A pulse I/O adapter is

recomended using external pulse generators and/or external pulse

modulators.

Add IF inputs for antenna and millimeter-wave (Option 020)

This option enables external IF inputs on the rear panel of the

PNA-X for applications such as antenna and millimeter-wave

test.

Add pulse modulator to internal first source (Option 021)

This option enables the internal pulse modulator on source 1.

Control of the modulator can also be done via pin 8 of the

Pulse I/O D-sub connector on the rear panel of the PNA-X

using an external pulse generator, or by using one of the internal

pulse generators (Option 025). The N1966A pulse I/O adapter

is recommended if using an external pulse generator.

(See diagram below for details of the D-sub connector.)

Add pulse modulator to internal second source (Option 022)

This option enables the internal pulse modulator on source 2.

Control of the modulator can also be done via pin 8 of the

Pulse I/O D-sub connector on the rear panel of the PNA-X

using an external pulse generator, or by using one of the internal

pulse generators (Option 025). The N1966A pulse I/O adapter

is recommended if using an external pulse generator. Option 224

or 400 required. (See diagram for details of the D-sub connector.)

Add four internal pulse generators (Option 025)

This option enables four internal pulse generators. These

pulse generators can be used to control the internal pulse

modulators and internal receiver IF gates, and are also available

on pins 10 through 13 of the Pulse I/O D-sub connector on

the rear panel of the PNA-X to control external modulators

and/or gates. The N1966A pulse I/O adapter is recommended

if using external pulse modulators. (See diagram for details of

the D-sub connector.)

Fast CW Sweep (Option 118)

This option uses FIFO (fi rst-in fi rst-out) to allow external point-

trigger acquisition of 400,000 data points per second on fi ve

measurement receivers. When enabled, there is no display

update, no background computation, or other interference

from the vector network analyzer application. All the data

gathered is placed into a 500 million points FIFO buffer. While

the data is going into FIFO it can be read from the FIFO buffer.

Accessories

Rack mount kit without handles (Option 1CM)

Adds a rack mount (5063-9217) and rail kit (E3663AC) for use

Pulse I/O adapter (N1966A)

An adapter for connecting between the Pulse I/O connector on

the rear panel of the PNA-X and the coaxial inputs and outputs

of external pulse generators and external pulse modulators.

Coaxial connectors are SMB-male. The PULSE IN connectors

are for controlling the PNA-X's internal IF gates, which are

enabled with Option H08 and used with narrowband detection.

The PULSE OUT connectors are from the PNA-X's four internal

pulse generators, which are enabled with Option 025. The

PULSE SYNC IN connector is used to synchronize the internal

pulse generators with an external timing pulse. The RF PULSE

MOD IN connector controls the internal pulse modulator(s) which

are enabled with Options 021 and 022.

Pulse I/O adapter (N1966A) simplifies connections

8

1 5

7

1 4

6

1 3

5

1 2

4

1 1

3

1 0

2

9

1

Pulse I/O D-sub connector (DB-15 female)

11

PNA-X Series Network Analyzer

Upgrade kits

Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X, order the corresponding item number.

The model and serial numbers of the instrument to be retrofitted are required as part of the order.

Description

Frequency upgrade 1

N5242A Extend analyzer’s frequency

Required option For N5241A For N5242A For N5244A For N5245A User installable

N5245A range to 26.5 GHz

Extend analyzer’s frequency

N5241A

N5244A

N5241AU-960

N/A

N/A

N/A

N/A N/A

N5244AU-990 N/A

No

No

Test set range to 50 GHz

Option 224 2-ports, add internal 2nd source, Options 200, 219 N5241AU-922 N5242AU-922 N5244AU-922 N5245AU-922 No combiner and mechanical switches

Option 423 4-ports, add internal combiner and Options 400, 419 N5241AU-927 N5242AU-927 N5244AU-927 N5245AU-927 No mechanical switches

Power configuration

Option 219 2-ports, extended power range Option 200 and bias-tees

N5241AU-921 N5242AU-921

N5244AU-921 N5245AU-921 No

Option 419 4-ports, extended power range Option 400 and bias-tees

Option H85 High-power configurable

(for 2- or 4-port) 419 or 423

N5241AU-926

Option 219, 224, N5241AU-H85

N5242AU-926

N5242AU-H85

N5244AU-926 N5245AU-926

N5244AU-H85 N5245AU-H85

No

No

Measurement applications

Option 010 Time-domain measurements

Option 028 Noise figure measurements using standard receivers

Option 029 Fully-corrected noise figure measurements for 2-port

Option 029 Fully-corrected noise figure measurements for 4-port or H85, and 080 or H85, and 080

Option H29 Add 26.5 GHz noise receivers Option 423

Option 080 Frequency offset

N5241AU-010

Option 219, 224, N5241AU-924

Option 419, 423, N5241AU-929

N/A

N5241AU-080

N5242AU-010

N5242AU-924

N5242AU-929

N/A

N5242AU-080

N/A

N/A

N5244AU-010 N5245AU-010

N5241AU-028 N5242AU-028 N5244AU-028 N5245AU-028

N/A

N/A

Yes

Yes

No

No

N5244AU-H29 N5245AU-H29 No

N5244AU-080 N5245AU-080 Yes

Option 082 Scalar-calibrated converter measurements

Option 083 Vector- and scalar-calibrated converter measurements

Option 084 Embedded LO measurements

Option 086 Gain compression application

Option 080

Option 080

N5241AU-082

N5241AU-083

N5242AU-082

N5242AU-083

N5244AU-082 N5245AU-082

N5244AU-083 N5245AU-083

Yes

Yes

Option 028, 029, N5241AU-084 N5242AU-084 N5244AU-084 N5245AU-084 Yes

H29, 082, 083, or

087

N5241AU-086 N5242AU-086 N5244AU-086 N5245AU-086 Yes

Option 087 Intermodulation distortion application

Option 460 Integrated true-mode stimulus Option 400 application

Option 551 N-port capabilities

Option 224 or 423

N5241AU-087

N5241AU-460

N5241AU-551

N5242AU-087

N5242AU-460

N5242AU-551

N5244AU-087 N5245AU-087

N5244AU-460 N5245AU-460

N5244AU-551 N5245AU-551

Yes

Yes

Yes

Nonlinear vector network analysis

Option 510 Nonlinear component

Option 514 Nonlinear X-parameters

Option 518 Nonlinear pulse envelope

Option 520 characterization domain

Arbitrary load-impedance

X-parameters

Options 419 and N5241AU-510 N5242AU-510 N5244AU-510 N5245AU-510 Yes

080, or 400, H85 and 080

Options 423, N5241AU-514 N5242AU-514 N5244AU-514 N5245AU-514 Yes

510

Options 021, 025 N5241AU-518 N5242AU-518 N5244AU-518 N5245AU-518 Yes and either one of

510 or 514

Option 514 N5241AU-520 N5242AU-520 N5244AU-520 N5245AU-520 Yes

1. Frequency upgrade options from N5241A or N5242A to N5244A or N5245A are not available. Trade-in is recommended.

12