MAINTENANCE. Marantz VP-12S2


Add to my manuals
40 Pages

advertisement

MAINTENANCE. Marantz VP-12S2 | Manualzz

MAINTENANCE

Replacing Lamp Unit

CAUTION:

• Do not touch the lamp and the lamp unit carelessly. It is extremely hot. Wait at least one hour for the lamp to cool down before handling.

• Do not loosen any screws except for those mentioned below.

• The lamp may break if handled improperly.

• Do not use other than a Marantz replacement lamp unit.

How to replace the Lamp Unit

PREPARATION:

When replacing the lamp, turn off the power for the projector. After the cooling fan stops, disconnect the power cord and wait for one hour until the lamp is cooled down completely, then replace the lamp.

1.

Press the STANDBY key on the remote controller or the

POWER key on the projector to turn the projector off.

5.

Remove the lamp cover screw.

2.

After the cooling fan stops, Unplug the AC power cord.

6.

Remove the lamp cover in the direction of the arrow.

Lamp cover

3.

Wait at the least one hour for the lamp and lamp unit to cool down.

4.

Read the caution and warning labels on the unit.

Lamp cover

7.

Remove the two screws of the lamp unit. At this time, do not remove the other screws.

WARNING

THIS COVER IS PROVIDED WITH

INTERLOCK TO REDUCE THE RISK OF

EXCESSIVE ULTRAVIOLET RADIATION.

DO NOT DEFEAT ITS PORPOSE OR

ATTEMPT TO SERVICE WITHOUT

REMOVING COVER COMPLETELY.

CAUTION : HIGH PRESSURE LAMP

MAY EXPLODED IF IMPROPERLY HANDLED.

REFER SERVICING TO QUALIFIED SERVICE

PERSONNEL.

ATTENTION : LA LAMPE SOUS

HAUTE PRESSION PEUT SI ELLE, N'EST

CAUTION HOT : UNPLUG

THE POWER CORD AND WAIT

60 MINUTES BEFORE CHARGING

THE LAMP.

ATTENTION CHAUD :

DEBRANCER LE CORD ON

MODEL NO. VP-16S1 / U1M

AC 120V 60HZ 2.0A

SERIAL NO.

PAS MANIPULEE CORRECTEMENT,

CONFIER L'OPERATION A UN

PERSONNEL D'ENTRETIEN QUALIFIE.

D'ALOMENTION ET ATENDER

60 MINUTES AVANT DE

CHANGER LAMPE.

WARNING

THIS COVER IS PROVIDED WITH

INTERLOCK TO REDUCE THE RISK OF

EXCESSIVE ULTRAVIOLET RADIATION.

DO NOT DEFEAT ITS PORPOSE OR

ATTEMPT TO SERVICE WITHOUT

REMOVING COVER COMPLETELY.

CAUTION :

HIGH PRESSURE LAMP

MAY EXPLODED IF IMPROPERLY HANDLED.

CAUTION HOT :

UNPLUG

THE POWER CORD AND WAIT

REFER SERVICING TO QUALIFIED SERVICE

PERSONNEL.

60 MINUTES BEFORE CHARGING

THE LAMP.

ATTENTION :

LA LAMPE SOUS

HAUTE PRESSION PEUT SI ELLE, N'EST

PAS MANIPULEE CORRECTEMENT,

CONFIER L'OPERATION A UN

PERSONNEL D'ENTRETIEN QUALIFIE.

ATTENTION CHAUD :

DEBRANCER LE CORD ON

D'ALOMENTION ET ATENDER

60 MINUTES AVANT DE

CHANGER LAMPE.

AC 120V 60H Z 2.0W

SERIAL NO.

MADE IN JAPAN

FABRIQUE AU JAPON