Electrical connection
For U.K. only
This tumble dryer is supplied ready for connection to an a.c. single phase
230 V, 50 Hz supply. The rated load is 3 kW. The machine is supplied with a 2 m long mains cable with moulded plug and the fuse rating is 13 A.
The appliance should be connected up only by a qualified electrician, in accordance with national and local safety regulations.
Connection should be made via a fused plug and a suitable switched socket which is easily accessible.
For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA.
The voltage, rated load and fuse rating are given on the data plate. Please ensure that these match the household mains supply.
Important
The wires in the mains lead are coloured in accordance with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol z or coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
WARNING
THIS APPLIANCE MUST BE EARTHED.
Non-rewireable plugs BS 1363
If this machine or appliance is fitted with a non-rewireable plug, the following information applies:
If the socket outlets are not suitable for the plug supplied with this product, it must be cut off and an appropriate plug fitted.
The plug cut from the flexible cord should be disposed of and on no account be inserted into a 13 A socket elsewhere in the house (electric shock hazard).
The fuse cover must be refitted when changing the fuse, and if the fuse cover is lost, the plug must not be used until a suitable replacement is obtained. The colour of the correct replacement cover is that of the coloured insert in the base of the plug, or the colour that is embossed in words in the base of the plug (as applicable to the design of plug fitted).
The correct fuse rating of the replacement fuses that are ASTA approved to
BS 1362 should be fitted. Replacement fuse covers may be purchased from your local electrical suppliers, electricity showroom, or Miele Service
Agent.
25
Electrical connection
For IRL only
This tumble dryer is supplied ready for connection to an a.c. single phase
230 V, 50 Hz supply. The rated load is
2.7 kW. The machine is supplied with a
2 m long mains cable with moulded plug and the fuse rating is 13 A.
The appliance should be connected up only by a qualified electrician, in accordance with national and local safety regulations.
Important
The wires in the mains lead are coloured in accordance with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol z or coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
WARNING
THIS APPLIANCE MUST BE EARTHED.
26
advertisement
Related manuals
advertisement
Table of contents
- 3 Guide to the appliance
- 6 Warning and safety instructions
- 8 Notes on laundry care
- 9 Loading and unloading washing
- 10 Programme selection
- 11 Programmes for Cottons
- 12 Programmes for Minimum iron and timed drying
- 13 Consumption data
- 14 Cleaning and care
- 15 Problem solving guide
- 17 After sales service
- 18 Installation
- 19 Installation - venting
- 25 Electrical connection
- 27 Technical Data