advertisement
PCI-2513 User's Guide Specifications
Note 2: Noise reflects 10,000 samples at 1 MHz, typical, differential short, using CA-68-3S cable.
Digital input / output
Table 3. Digital input/output specifications
Number of I/O
Ports
Input scanning mode
Configuration
Input protection
Input high
Input low
Output high
Output low
24
Three banks of eight.
Each port is programmable as input or output
Asynchronous, under program control at any time relative to input scanning
10 kΩ pull-up to +5 V, 20 pf to analog common
±15 kV ESD clamp diodes
+2.0 V to +5.0 V
0 to 0.8 V
>2.0 V
<0.8 V
Output current
Digital input pacing
Digital output pacing
Output 12 mA per pin, 200 mA total continuous
Onboard clock, external input scan clock (XAPCR)
Four programmable sources:
Onboard output scan clock, independent of input scan clock
Onboard input scan clock
External output scan clock (XDPCR), independent of external input scan clock (XAPCR)
External input scan clock (XAPCR)
Digital input trigger sources and modes
Digital output trigger sources Start of input scan
Data transfer
Sampling/update rate
Pattern generation output
DMA
12 MHz maximum
Two of the 8-bit ports can be configured for 16-bit pattern generation. The pattern can also be updated synchronously with an acquisition at up to 12 MHz.
Counters
Counter inputs can be scanned based on an internal programmable timer or an external clock source.
Channels
Resolution
Input frequency
Input signal range
Input characteristics
Trigger level
Minimum pulse width
De bounce times
Time-base accuracy
Counter read pacer
Trigger sources and modes
Programmable mode
Counter mode options
Table 4. Counter specifications
Four independent
32 bits
20 MHz maximum
–5 V to 10 V
10 k pull-up, ±15 kV ESD protection
TTL
25 ns high, 25 ns low
16 selections from 500 ns to 25.5 ms, positive or negative edge sensitive, glitch detect mode or debounce mode
30 ppm (0 °C to 50 °C)
Onboard input scan clock, external input scan clock (XAPCR)
Counter
Totalize, clear on read, rollover, stop at all Fs, 16- or 32-bit, any other channel can gate the counter
37
advertisement
Related manuals
advertisement
Table of contents
- 6 What you will learn from this user's guide
- 6 Conventions in this user's guide
- 6 Where to find more information
- 7 Overview: PCI-2513 features
- 7 Software features
- 8 What comes with your PCI-2513 shipment?
- 8 Hardware
- 8 Optional components
- 9 Additional documentation
- 9 Unpacking the PCI-2513
- 9 Installing the software
- 9 Installing the PCI-2513
- 10 Configuring the hardware
- 10 Connecting the board for I/O operations
- 10 Connectors and cables
- 11 Connector pinout
- 11 Cabling
- 12 Field wiring and signal termination
- 12 Installing multiple boards
- 13 PCI-2513 block diagram
- 13 Synchronous I/O – mixing analog, digital, and counter scanning
- 14 Bus mastering DMA
- 14 Analog input
- 14 Analog input scanning
- 14 Settling time
- 14 Example: Analog channel scanning of voltage inputs
- 15 Digital I/O
- 15 Digital input scanning
- 15 Digital outputs and pattern generation
- 15 Triggering
- 15 Hardware analog triggering
- 16 A note on the hardware analog level trigger and comparator change state
- 16 Digital triggering
- 16 Software-based triggering
- 16 Analog triggering
- 16 Pattern triggering
- 16 Counter triggering
- 17 Stop trigger modes
- 17 Pre-triggering and post-triggering modes
- 17 No pre-trigger, post-trigger stop event
- 17 Fixed pre-trigger with post-trigger stop event
- 17 No pre-trigger, infinite post-trigger
- 17 Fixed pre-trigger with infinite post-trigger
- 17 Counter inputs
- 18 Mapped channels
- 18 Counter modes
- 18 Totalize mode
- 18 Clear on read mode
- 19 Stop at the top mode
- 19 32-bit or 16-bit
- 19 Latch on map
- 19 Gating "on" mode
- 19 Decrement "on" mode
- 19 Debounce modes
- 20 Trigger after stable mode
- 20 Trigger before stable mode
- 21 Debounce mode comparisons
- 22 Encoder mode
- 24 Maximizing encoder accuracy
- 24 Connecting the PCI-2513 to an encoder
- 26 Timer outputs
- 27 Example: Timer outputs
- 27 Using detection setpoints for output control
- 27 What are detection setpoints?
- 27 Setpoint configuration overview
- 29 Setpoint configuration
- 29 Set high limit
- 29 Set low limit
- 29 Set criteria
- 29 Set output channel
- 29 Update modes
- 29 Set values for output
- 30 Using the setpoint status register
- 30 Examples of control outputs
- 30 Detecting on analog input and FIRSTPORTC updates
- 31 Detection on an analog input, timer output updates
- 31 Using the hysteresis function
- 32 Detecting setpoints on a totalizing counter
- 32 Detection setpoint details
- 32 Controlling digital and timer outputs
- 33 FIRSTPORTC or timer update latency
- 36 Analog input
- 36 Accuracy
- 37 Digital input / output
- 37 Counters
- 38 Input sequencer
- 38 Frequency/pulse generators
- 39 Trigger sources and modes
- 39 Power consumption
- 39 PCI compatibility
- 39 Environmental
- 40 Mechanical
- 40 Main connector and pinout