Model VM08 Owner’s Manual
Before Operation
(IMPORTANT Be sure to read below before first using your VM08.)
* Remove the insulation paper
The VM08 uses a memory back up battery inside. You will find a piece of insulation paper attached to avoid current dissipation. When using the VM08 for the first time, turn ON the power and then remove the insulation paper.
The insulation paper is easily removed by pulling it in direction of arrow as shown at right.
Insulation paper
* Caution when powering on
There is no power switch in VM08.
Power is switched ON/OFF simply by plugging and unplugging the VM08’s AC adaptor plug.
Be sure to switch off power to the monitor amplifier connected to the VM08 output or fully retard the input level controls to prevent damage to connected speakers when switching power ON/OFF in this manner.
1
2
9V
AD-9B
ONLY
DC IN
OUT
DIGITAL FOOT SW
RESET
AUX SEND
8/7
7
8
6/5
5
6
4
TRIM
-10 -50
3 TRIM
-10 -50
INPUT
R ST OUT
L
2 TRIM
-10 -50
1
PHONES
TRIM
-10 -50
RESET switch
AC adaptor
< Caution >
If the VM08 is not to be used for a long time, be sure to unplug the AC adaptor from the wall outlet.
* Reset of VM08
It is possible for the computer to malfunction at power ON/OFF or by electro induction noise from lightning. In this happens, switch the power ON/OFF to the VM08 several times. If it does not return to normal operation, press the rear panel [RESET] switch with a slender ball point pen or similar tool. This returns all settings to the initial figures setup at shipping from the plant. This procedure can be used to clear all stored scene memories.
<Please remember this!>
If reset is executed with the INPUT and MASTER raised simultaneous with start up of this unit, the
LEVEL ADJUST key/FADER ADJUST key will blink. This indicates that the VM08 has entered the
Level Adjust Mode/Fader Adjust Mode because of the difference between present fader position and the fader position at start up following reset. To exit from this mode, retard all faders to the
[MIN] position, and the key blinking will stop.
* Internal battery for the memory back up
The internal battery has a life expectancy of about two years.
When the battery runs low and its voltage falls below a certain level, the warning message "BattEmpty" will appear in the display. If you continue to use the unit an old battery, your stored scene memories will be lost when the power is turned off. Do not try to replace the battery yourself as there are no user-serviceable parts inside. Please ask your Fostex distributor or an authorized service station to do the job.
<Please remember this!>
There is an automatic internal battery voltage check function in the VM08.
Refer to [Setup mode] on page 27.
6
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Precautions
- 4 Names and Functions
- 6 Before Operation
- 6 Remove the insulation paper
- 6 Caution when powering ON
- 6 Reset of VM
- 7 Peripheral Equipment Connection
- 9 Application Examples
- 11 Initial State of the VM
- 12 Normal Mix Mode
- 14 Channel Parameter Edit Mode
- 14 Setup method for PAN setting
- 15 EQ setup method
- 15 Setup method of the effect send level
- 16 Setup method of the aux send level
- 17 PRE/POST setup method
- 18 Effect Edit Mode
- 19 About the effect types
- 20 Selecting the effect type
- 21 Effect parameter settings
- 21 Muting an effect
- 22 Effect parameter details
- 24 Scene Memory Mode
- 24 Storing a scene memory
- 24 Recalling a scene memory
- 25 Level adjust
- 25 Fader adjust
- 26 Directly recalling a scene memory
- 26 Clearing a scene memory
- 27 Setup Mode
- 27 Making settings in setup mode
- 27 Details of the setup menu
- 27 Input 5/6 input setting
- 27 Input 7/8 input setting
- 28 Fader fix setting
- 28 Channel fader recall setting
- 28 Master fader recall setting
- 28 Foot switch setting
- 28 Battery check
- 29 Specifications