7.14.10 Display the Alarm Handler Status

In the MR window, select Popup Menu - [Mode] -> [Alarm Handler].

When the realtime OS is MRxx conformed to uITRON specifications V.3.0, the following data is displayed in the status bar.

7.14.10.1 Display the Alarm Handler Status(When the realtime OS is MRxx conformed to uITRON specifications V.3.0.)

Of all the cycle start handlers defined in the configuration, only those which are not started yet at present are listed in the ascending order of start time. The function of each item is listed below.

(When the realtime OS is MRxx conformed to uITRON specifications V.3.0.)

Item Contents

ID

StaAddr

(name)

AlarmTime

ID No. of alarm handler

Starting address of alarm handler

Name of alarm handler

Starting time of alarm handler

7.14.10.2 Display the Alarm Handler Status(When the realtime OS is MRxx conformed to uITRON specifications V.4.0.)

Of all the cycle start handlers defined in the configuration, only those which are not started yet at present are listed in the ascending order of start time. The function of each item is listed below.

(When the realtime OS is MRxx conformed to uITRON specifications V.4.0.)

Item Contents

ID

Name

ID No. of alarm handler

Name of alarm handler

Almtim

Status

The amount of time by the millisecond remaining before the alarm handler's activation time

Activity status of alarm handler

• The following are displayed in the Status area:

TALM_STA

TALM_STP

Alarm handler is in an operational state

Alarm handler is in a non-operational state