4.2 Diagram 2 (No. F747M.11.00) Pyrylandia Sp. z o. o. F-747M Train Radio Installation Manual (double cabin locomotive version) page 8/9
No.
1 F-747 Control Unit
2 Control Unit Standard Rack
3 F-747 Microphone
4 Microphone socket
5 Control Unit accessories socket
6 Support socket
Object EN
7 Control Unit to Rx/Tx Unit cable
8 Angle-plug Radmor
9 Assembling screw
10 Tx/Rx Unit
11 Tx/Rx Unit Standard Rack
12 Tx/Rx Unit power supply connector
13 Antenna connector
14 Control Unit socket
15 Tx/Rx Unit accessories socket
16 Tx/Rx Unit support socket
17 Antenna Radmor
18 Antenna socket Radmor
19 Antenna shield Radmor
20 DC/DC converter (24/13.6)V
21 DC/DC converter rack
22 Ground cable connection
23 Tx/Rx Unit power supply connector
24 cable fuse housing
25 DC/DC converter power supply cable (+)
26 DC/DC converter power supply cable (-)
27 Switching Panel to DC/DC converter power supply cable (+)
28 Switching Panel to DC/DC converter power supply cable (-)
29 Switching Panel power supply plug
30 Antenna coaxial cable
31 Antenna cable connector
32 Switching Panel (without the choking coil)
33 Power supply main switch
34 Cabin "A" and "B" switch
35 Switching Panel power supply socket
36 Switching Panel Tx/Rx Unit socket
37 Power supply fuse base
38 Soldered joint to connect Power Supply (+)
39 Screw joint place to connect Power Supply (-)
40 Power Supply cable from locomotive (-)
41 Power Supply cable from locomotive (+)
42 Soldering link strip
43 Cabin "A" to Switching Panel cable
44 Cabin "B" to Switching Panel cable
45 Control Unit socket
46 Angle-plug clip
47 Buckle Radmor
48 Switching Panel to Tx/Rx Unit cable
49 Angle-plug Radmor
50 Radio Stop relay cable (+)
51 Radio Stop relay cable (-)
52 Radio Stop relay
53 Locomotive Power Supply (battery)
54 Choking coil
Name/Spec.
Man F-747M
Radmor 06313-1
Maxon MA-2472
Mic. Socket
F-747M
06313-1
MA-2473
MPLT-166S
Type
CANON DB25F DB25F
CANON DB9F DB9F
LiHCH 20x0,25mm
2
LiHCH 20x0,25mm
2
Angle-plug DB25M DB25M
M4, knurled-head
N/O F-747M
Radmor 0631-1
Maxon power F
N female
CANON DB25F
CANON DB9F
CANON DB9F
3086
M4
F-747M
0631-1 female power connector
N antenna connector
DB25F
DB9F
DB9F
3086
N female
Radmor shield
PV6i
PV6i rack
PV6i ground
Maxon power M
Cable fuse
N
Alfatronix PV6i
Huber+Suhner
Huber+Suhner
Huber+Suhner
Huber+Suhner
SzP-3 VIII 88 "K"
RG214
N male
Radmor 0673
AB 194L-E16
Radmor 0673-2000
Kontakt WSz-3 male
RADOX TENUIS - TW 2.5mm
2
RADOX TENUIS - TW 2.5mm
2
RADOX TENUIS - TW 2.5mm
2
RADOX TENUIS - TW 2.5mm
2
SzP-3
RG214
N
0673/2
194L-E16-1752
0673-2000
WSz-3
CANON DB25F
Radmor Br1
DB25F
Br1
Radmor
Radmor
Huber+Suhner RADOX TENUIS - TW 2.5mm
2
RADOX TENUIS - TW 2.5mm
2
Huber+Suhner
Radmor PZ1
Huber+Suhner
Huber+Suhner
CANON DB25F
Radmor fastener
Canon holder
LiHCH 20x0,25mm
2
LiHCH 20x0,25mm
2
Angle-plug Radmor
Huber+Suhner
Huber+Suhner
Relay
PZ1 3362-1400
RADOX GKW-LW/S EMC 20x0,5mm
2
RADOX GKW-LW/S EMC 20x0,5mm
2
DB25F
DB25M
RADOX TENUIS - TW 0.5mm
2
RADOX TENUIS - TW 0.5mm
2
R5
Locomotive battery
Coil
24VDC
0673-5000/2
Note for two cabin locomotive version, should be programmed with screws
6 pin female plug
6 pin male socket
25 pin female socket
9 pin female socket
20 x 0,25mm
2 screened cable ,length ~ 1,75m
25 pin male plug
M4, knurled-head thumb screw should be programmed with screws two-pin female click connector female
25 pin female socket
9 pin female socket
9 pin female socket should be tuned to middle band after installation, installed with 6 screws M8 female
Mounted with 12 screws M6
4 male 6.3mm connector
3 screw assembling screw joint to locomotive ground two-pin male click connector glass fuse 10A red, 2.5mm
2
, length ~ 1m black, 2.5mm
2
, length ~ 1m red, 2.5mm
2
, length ~ 1m black, 2.5mm
2
, length ~ 1m straight or angle, 3 pin female plug
RG214 (or better) - usually is not at delivery joint type N, male for RG214 cable
6 screw assembling two-way, on-off switch multi-way, two-position switch
Szp-3, 3 pin male socket
25 pin female socket screw-in type fuse carry out soldered joint connected to (+) locomotive power supply conected to (-) locomotive power supply min. 2mm
2
diameter for 5m cable length, for more than 5m length use bigger cable diameter soldered 51 fields link strip
20x0.5mm
2
screened cable - are not at delivery. Cross-section min. 0,5 mm
2
25 pin female socket (in Cabin "A" and "B") buckle clip buckle locking fastener
20x0,25mm
2
screened cable, length ~ 1,8m
25 pin male plug
0.5mm
2
- is not at delivery
0.5mm
2
- is not at delivery type of relay depends from locomotive, and is not at delivery on board power supply
For tensions powering lower than 90VDC the coil should not being connected
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
4
4
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
4
12
1
1
1
1 piece
2
2
2
2
2
2
1
1
4.3 Descriptive table for F747M.00.00 and F747M.11.00 drawings Pyrylandia Sp. z o. o. F-747M Train Radio Installation Manual (double cabin locomotive version) page 9/9
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project