Kamstrup Multical 801 Heat Meter


Add to my manuals
16 Pages

advertisement

Kamstrup Multical 801 Heat Meter | Manualzz

MULTICAL® 801

D A T A S H E E T

Cabinet design

Power supply

Jumper for modules

Extra power supply for

GSM/GPRS module

Approved meter data

Approval DK-0200-MI004-009

Standard EN 1434:2007 and OIML R75:2002

EU-directives

– MID (Measuring Instruments Directive)

– LVD (Low Voltage Directive)

– EMC (Electromagnetic Compatibility Directive)

Temperature range

Differential range

Accuracy

θ: 2...180°C

∆Θ: 3...170 K

E

C

±(0.5 + ∆Θ min

/ ∆Θ)%

Temperature sensors

– Type 67-F and 67-K

– Type 67-G and 67-L

Pt100 – EN 60 751, 4-wire connection

Pt500 – EN 60 751, 4-wire connection

Flow sensor types

– ULTRAFLOW®

– Electronic meters with active and passive pulse output

– Mechanical meters with electronic pick-up

– Mechanical meters with reed switch

Flow sensor sizes

– [kWh]

– [MWh]

– [GJ]

EN 1434 designation q p q p q p

0.6 m 3 /h...q

p

0.6 m 3 /h...q

0.6 m 3 /h...q

p p

15 m 3 /h

15000 m 3 /h

30000 m 3 /h

Environmental class A and C

MID designation

– Mechanical environment Class M1

– Electromagnetic environment Class E1 and E2

– Non condensing, closed location (indoor installation), 5…55°C

Backup-battery

Module 2

Module 1

Two optional pulse inputs VA and VB

Test and verification plug

10

5810625_H1_GB_02.2012