advertisement
33. OPERATION MODES -- Location 94
The keypad is programmable for keypad mode to work stand-alone for door control directly or for server mode to work with a split-decoder for high security access control.
LOCATION
94
(1)
→
OPERATION MODES
0 or 1
(2)
→
VALIDATION
#
(3)
(1) LOCATION
Key in Location 94
(2) OPERATION MODES
0 – Keypad Mode (Default)
Keypad Mode sets the keypad for stand-alone operation to provide its available functions. It is compatible with the auxiliary readers/keypads for multi-station expansion.
1 – Server Mode
Server Mode sets the keypad to compatible with both the decoder for split-decoded operation and the auxiliary readers/keypads for multi-station expansion. A split decoded keypad system uses the keypad(s) for human interface outside and the internal decoder for door lock control to prevent sabotage.
(3) VALIDATION
Press # key once. Two-beep confirms the entry
The DK-2800 MK-II keypads are set in “ KEYPAD MODE ” in default. It is necessary to set it to “ SERVER
MODE ” while the keypad is in Split-Decoded operation. Here are the code entries of setting the keypad into
“ SERVER MODE ”
94 1 #
34. CLOSE PROGRAMMING MODE -- * *
Always close programming mode with * * to set system back to normal Operation after programming.
The button is equivalent to the * button in the keypad with bell button.
VALIDATION
* * ------------------------------- System is back to normal operation mode
50
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 1. INTRODUCTION
- 4 2. EXPLANATION OF SYMBOLS
- 5 3. INTENDED USE
- 5 4. DELIVERY CONTENT
- 6 5. FEATURES AND FUNCTIONS
- 7 6. SAFETY INSTRUCTIONS
- 7 7. INSTALLATION PRECAUTIONS
- 8 8. OPERATING ELEMENTS
- 8 a) DA-2800 (OPTIONAL) -- SPLIT-DECODER WITH REMOTE CONTROL RECEIVER
- 10 b) DA-2801 -- SPLIT-DECODER
- 12 9. CONNECTION TERMINALS
- 16 10. SETTING UP A SPLIT-DECODED KEYPAD SYSTEM
- 19 11. PREPARATION FOR PROGRAMMING
- 19 a) CRITERIA FOR CODES AND CARDS
- 19 b) SECURITY LEVEL OF THE OPERATION MEDIA
- 20 c) LIST OF USER INFORMATION
- 21 12. PROGRAMMING & OPERATION
- 21 a) POWER-UP THE KEYPAD
- 21 b) SET KEYPAD IN PROGRAMMING MODE WITH MASTER CODE
- 21 c) DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE
- 22 d) SYSTEM REFRESHING WITH “REFRESHING CODE
- 22 e) THE DEFAULT VALUES AFTER REFRESHING
- 23 13. MASTER CODE -- Location
- 24 14. SUPER USER CODE -- Location
- 26 15. COMMON USER CODES FOR OUTPUT 1, 2 & 3 -- Locations
- 27 16. USER CODES / CARDS FOR OUTPUT 1, 2 & 3 -- Locations
- 31 17. VISITOR CODES (FOR OUTPUT 1 ONLY) -- Location
- 33 18. DURESS CODES (FOR OUTPUTS 1, 2 & 3) -- Locations
- 35 19. OUTPUT MODE & TIMING FOR OUTPUT 1, 2 & 3 -- Locations
- 36 20. SYSTEM REAL-TIME-CLOCK -- Location
- 37 21. START & STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 -- Location
- 39 22. PERSONAL SAFETY AND SYSTEM LOCK-UP -- Location
- 39 23. USER CODE ENTRY MODE – AUTO OR MANUAL -- Location
- 40 24. PACIFIER TONES ON-OFF SELECTION -- Location
- 41 25. OUTPUT OPERATION ANNOUNCER -- Location
- 41 26. STATUS LED FLASHING ON-OFF DURING STANDBY -- Location
- 42 27. DOOR FORCED OPEN WARNING & TIMING -- Location
- 43 28. DOOR PROPPED-UP WARNING & THE DELAY TIME -- Location
- 45 29. EGRESS DELAY, WARNING AND ALARM -- Location
- 47 30. DOOR OPENING ALARM & TIMER -- Location
- 48 31. WIEGAND DATA OUTPUT MODES -- Location
- 49 32. WIEGAND DATA OUTPUT FORMAT -- Location
- 50 33. OPERATION MODES -- Location
- 50 34. CLOSE PROGRAMMING MODE
- 51 35. PROGRAMMING MAKE SIMPLE – FOR GENERAL USERS
- 53 36. WIEGAND OUTPUT FORMATS FOR ADVANCED KEYPADS
- 56 37. PROGRAMMING SUMMARY CHART
- 59 38. APPLICATION EXAMPLES
- 59 a) BASIC WIRINGS OF A SPLIT-DECODED ACCESS CONTROL DOOR LOCK
- 60 b) A SPLIT-DECODED ACCESS CONTROL DOOR LOCK WITH AUXILIARY KEYPAD
- 61 c) A DUAL KEYPAD SPLIT-DECODED ACCESS CONTROL INTER-LOCK SYSTEM
- 63 39. APPLICATION HINTS FOR THE AUXILIARY TERMINALS
- 65 40. THE OPTIONAL AUXILIARY READERS & KEYPADS
- 66 41. AUXILIARY INFORMATION
- 67 42. TECHNICAL DATA