MXT-1001 / MXT. AMX CWU-SAA596803, CWU-SAA596805, CWU-SAA596807


Add to my manuals
54 Pages

advertisement

MXT-1001 / MXT. AMX CWU-SAA596803, CWU-SAA596805, CWU-SAA596807 | Manualzz

Installing Tabletop (MXT) Panels

MXT-1001 / MXT-701

Detailed specifications drawings for the MXT-1001 and M XT-701 are available to download from www.amx.com.

Connector Locations - MXT-1001/MXT-701

Two Type A USB ports are located on the rear right corner of the panel (FIG. 17). USB peripherals (i.e. mouse, keyboard) may be connected to either of the two USB ports on the rear of the device. Updates to the device’s firmware can also made via the USB ports (see the Modero G5 Configuration and Programming Guide for details). Note that FIG. 17 shows the MXT-1001, but the USB ports are in a similar location on the MXT-701.

USB Ports Entry for RJ45/PoE Cable

FIG. 17 MXT-1001 - rear view

NOTE:

Refer to the Power via PoE section on page 32

for details on PoE and Ethernet Cable Installation and Modification.

Power via 13.5V

The MXT-2001-PAN and MXT-1901-PAN use a 13.5V -compliant power supply to provide power to the panel via the 2-pin 3.5mm captive wire PWR connector. The incoming PWR and GND wires from the power supply must be connected to the corresponding locations within the PWR connector.

NOTE: Connecting power to the panel should be done using the included 2-pin 3.5mm captive wire connector included with the device. This connector is retained within its port with locking screws instead of the pins on each side of standard captive wire connectors, and using force to insert a standard captive wire connector may damage the device.

Wiring a 13.5V

Power Connection

To use the 2-pin 3.5mm captive wire connector with a 13.5V

-compliant power supply, the incoming PWR and GND wires from the external source must be connected to their corresponding locations on the connector (FIG. 18). The connector uses locking screws to insure a connection to the device, so make sure to insert and tighten the screws before applying power.

PWR +

Power Supply

GND -

To the Touch Panel

FIG. 18 NetLinx power connector wiring diagram

1.

Insert the PWR and GND wires on the terminal end of the 2-pin 3.5mm captive wire cable.

Match the wiring locations of the +/- on both the power supply and the terminal connector.

2.

Tighten the clamp to secure the two wires.

Do not tighten the screws excessively; doing so may strip the threads and damage the connector.

3.

Verify the connection of the 2-pin 3.5mm captive wire to the external 13.5V

-compliant power supply and apply power.

Power via PoE

Power for the MXT-1001 and MXT-701 is supplied via PoE (Power Over Ethernet), utilizing an AMX-certified, capacitive touchcompliant PoE injector such as the PS-POE-AT High Power PoE Injector ( FG423-81 ) or other approved AMX PoE power source.

The incoming Ethernet cable should be connected to the RJ45 port on the cable attached to the device.

Modero X® Series G5 Touch Panels - installation & Hardware Reference Manual 32

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!