control Panel Indicators
The following is a description of the control panel indicators.
Motor
Running
Indicator
Pressure
Indicator
Digi-Trac™ control System Operation
The Digi-Trac™ Control System is an optional add-on that increases the functionality of the sprayer. It is installed directly below the pressure control knob on the control panel. It consists of a display and four function keys. The display shows various menu screens that allow the user to customize and monitor sprayer operation using the function keys.
Display
SET PSI
ACTUAL PSI
3000
2950
Function
Keys
Pressure Indicator
The pressure indicator shows the current operating pressure of the sprayer. It has three different indications: blinking yellow, solid yellow, and solid green.
Blinking yellow
When the pressure indicator is blinking yellow, the sprayer is operating between 0 and 200 PSI. A blinking yellow pressure indicator means:
• The sprayer is plugged in and turned “ON”
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the PRIME/SPRAY valve between positions
• It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow when the pressure control knob is set at a higher pressure and the PrImE/SPray valve is in the
SPray position, either the spray tip is worn or the sprayer is in need of service/repair.
Solid yellow
When the pressure indicator is solid yellow, the sprayer is operating between 201 and 1900 PSI. A solid yellow pressure indicator means:
• The sprayer is at the proper pressure setting for spraying stain, lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the pressure is set so that it starts at solid green, it indicates one of the following:
a. Tip wear Indicator — when spraying with latex or at high pressure the solid yellow appears. This means the tip is worn and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the sprayer is put in the gun, the pressure indicator will turn from solid green to solid yellow.
c. Fluid Section wear — if a solid yellow pressure indicator appears when using a new tip and the pressure is set at maximum, service may be required (worn packings, worn piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is operating between 1901 and 3300 PSI. A solid green pressure indicator means:
• The sprayer is at the proper pressure setting for spraying oilbased and latex house paints
• The sprayer is operating at peak performance at a high pressure setting
motor running Indicator
The Motor Running indicator is on when the motor is commanded to run. This indicator is used by service centers to troubleshoot motor problems.
Function Keys
The function keys are numbered 1–4. Each key is labeled with an additional function as well.
#1/menu Key
Pressing the #1 key scrolls through the available menu screens or performs a function described on the active menu screen.
#2/p Key
Pressing the #2 key performs a function described on the active menu screen or increases a value.
#3/q Key
Pressing the #3 key performs a function described on the active menu screen or decrease a value.
#4/Select Key
Pressing the #4 key selects the active menu screen or performs a function described on the active menu screen.
menu Screens
Several menu screens are available for the user to customize and monitor sprayer operation. They include Main Screen, User Pre-
Sets, Volume Pumped, Job Volume, Unit Serial #, TImers, Job Timers,
Service Time, Security Code, Prime, and RAPID CLEAN.
main Screen
The Main Screen is the default screen for the control system at sprayer startup.
SET PSI
ACTUAL PSI
Pressing the #2 key switches between PSI, Bar, and MPa units of measure. Press the #1 key to scroll through the remaining menu screens.
3000
2950
Volume Pumped Screen
The Volume Pumped screen shows the total number of gallons or liters sprayed by the sprayer.
To select the Volume Pumped screen, press the #4 key.
VOLUME PUMPED
MENU-1 SELECT-4
GALLONS X
MENU-1
job Volume Screen
The Job Volume screen allows the user to reset a gallon counter to track usage on specific jobs.
To select the Job Volume screen, press the #4 key.
JOB VOLUME
MENU-1 SELECT-4
JOB GAL
MENU-1
XXXX
RESET-3
unit Serial # Screen
The Unit Serial # screen shows the sprayers serial number.
To select the Unit Serial # screen, press the #4 key.
UNIT SERIAL #
MENU-1 SELECT-4
SER # XXXXXXXXXX
MENU-1
English 6 © Titan Tool Inc. All rights reserved.
English
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Safety Information
- 3 Specifications
- 4 General Description
- 4 Operation
- 4 Setup
- 5 Preparing to Paint
- 5 Painting
- 6 Control Panel Indicators
- 6 Digi-Trac™ Control System Operation
- 7 Pressure Relief Procedure
- 8 Spraying
- 8 Spraying Technique
- 8 Practice
- 9 cleanup
- 9 maintenance
- 9 General Repair and Service Notes
- 10 Replacing the Motor
- 10 Replacing the Gears
- 11 Replacing the Transducer
- 11 Replacing the PRIME/SPRAY Valve
- 12 Servicing the Fluid Section
- 13 Replacing the Filters
- 14 Troubleshooting
- 15 Digi-Trac™ Control System Error Messages
- 44 Parts Listings
- 44 Main Assembly
- 46 Siphon Assembly (skid and low rider assembly)
- 46 Skid Assembly
- 47 Drive Assembly
- 48 Fluid Section Assembly
- 50 Low Rider Assembly
- 51 High Rider Assembly
- 52 Electrical Schematic
- 52 Labels
- 53 Accessories
- 56 warranty