SPECIFICATIONS
General Specifications
Model
Rated Frequency (Hz)
Rated Voltage (V)
Rated Current (A)
Max Current (A)
DC Output Voltage
Rated Output
Maximum Output
Phase
P1000i
ALTERNATOR
7.5
8.3
900 W(
1000 W
60
P2000i
120
13.3
16.6
12V (5A)
1600 W
2000 W
Single
ENGINE
Model
Type
Displacement (cc)
Engine Oil
KG144 KG158
Single cylinder, 4 stroke, vertical shaft, air-cooled, OHV
58 106
Polaris 5W-30 Generator Oil
Engine Oil Capacity qt(L) (0.2 Liters)
Intake Valve Clearance
.42(.4)
0.0031-0.0039 in (0.18-0.10 mm)
Exhaust Valve Clearance
Spark Plug-Gap
0.0039-0.0059 in (0.10-0.15 mm)
UR5 - 0.024 - 0.028 in (0.6 - 0.7 mm)
GENERAL
Fuel
Fuel Tank Capacity
Starting System
Dimensions (L x W x H)
Weight
Full Tank Run Time Hours at Rated Load
AC Circuit Breaker
DC Fuse
DC Charging Cord
87 Octane (Up to 10% Oxygenated)
0.7 gallons (2.6 L) 1 gallon (3.8L)
Recoil
21.4”x13”x17.6”
545mm×330mm×448mm
54.45lbs.(24.7kg)
4 Hours 3.5 Hours
Electronic
5 Amp
Standard
38
Polaris Lubricants and Maintenance
Products
ENGINE OIL
PART NUMBER
2879383
DESCRIPTION
Polaris 5W-30 Generator Oil
(1 Quart) (32 oz.)
GREASE / SPECIALIZED LUBRICANTS
2871329 Dielectric Grease (Nyogel™)
2871326
ADDITIVES
Premium Carbon Clean / Fuel Stabilizer
(12 oz.) (12 count)
SPECIFICATIONS
39
SPECIFICATIONS
Modified coefficient table of ambient condition power
The conditions of generator rated output:
Altitude: 0 m Ambient temperature: 25°C Relative humidity: 30%
Ambient modified coefficient: C (Relative humidity 30%)
Altitude
(m)
25 30
Ambient temperature (
°
C)
35 40
0
500
1000
2000
1
.93
.87
.75
.98
.91
.85
.73
.96
.89
.82
.71
3000
4000
.64
.54
.62
.52
.6
.5
Note: When the relative humidity is 60%, the modified coefficient is C-0.01
When the relative humidity is 80%, the modified coefficient is C-0.02
When the relative humidity is 90%, the modified coefficient is C-0.03
When the relative humidity is 100%, the modified coefficient is C-0.04
Counting example:
When the rated power of generator is P
N
=5KW, altitude is 1000m, ambient N temperature is 35°C relative humidity is 80%, the rated power of generator is:
P=P
N
X (C-0.02) = 5 X (0.82-0.02) = 4KW
.58
.48
.93
.87
.80
.69
45
.90
.84
.78
.66
.56
.46