advertisement
EM1005X- Installation/User Manual
Ordering the System
The i8305 is configured using DIP switches for determining the EIM location; Port or Starboard and configuring the tachometer pulses per revolution (PPR) to match the engine flywheel teeth count. Another parameter stored is the engine hours. Should the EM1005x be ordered without the M701x Display, this data must be defined when placing the order.
See Table Below:
ENGINE POSITION: Port or Starboard
ENGINE HOURS:
SENDER 2 INPUT:
FLYWHEEL COUNT: xxx.x Hours
Defaults:
Fuel Tank 3 for Port
Fuel Tank 4 for Starboard
(Can be configured via
M701x for Water, Waste,
Rudder Angle or “Not Used”.)
129, 127, 117, 116 or 97
LY2 129
LP 117
JH4 116
JH4T 127
YM 97
Note 1. A charge alarm will activate the EM1005x alarm output but may not be present on the TFX i5601 display.
Note 2. Boost Alarm (over boost) is not available.
Copyright 2010 MBW Technologies, LLC All Rights Reserved 7
EM1005X- Installation/User Manual
Reading the configuration settings of the i8305 requires removing the top cover and noting the DIP switch settings. See Table below.
Switch
5
Switch
4
Switch
3
Switch
1
PPR
97
PPR 114
Off
Off
Off
Off
Off
On
X
X
PPR 116
PPR 117
PPR 127
PPR 129
PORT
STBD
Off
Off
On
On
On
On
Off
Off
Off
On
Off
On
X
X
X
X
Off
On
8 7 6 5 4 3 2 1
ON
8 7 6 5 4 3 2 1
ON
i8305 Dip Switch Locations and Settings