7. F.A.Q
7. F.A.Q
1. In the case of that the oscilloscope is still in the black-screen state without any display after the power is switch on, implement the following fault treatment procedure.
z Check whether the power connection is connected properly. z Check whether the power switch is pushed down to the designated position. z Check whether the fuse which is beside the
AC power input jack
is blew (the cover can be pried open with a screwdriver). z Restart the instrument after completing the checks above. z If this product still can not work normally, please get in touch with Lilliput and we will be under your service.
2. After acquiring the signal, carry out the following operations if the waveform of the signal is not displayed in the screen.
z Check whether the probe is properly connected to the signal connecting wire. z Check whether the signal connecting wire is correctly connected to the BNC
(namely, the channel connector). z Check whether the probe is properly connected with the object to be measured. z Check whether there is any signal generated from the object to be measured (the trouble can be shot by the connection of the channel from which there is a signal generated with the channel in fault). z Make the signal acquisition operation again.
3. The measured voltage amplitude value is 10 times greater or smaller than the actual value.
Check whether the channel attenuation coefficient and the attenuation ration of the
probe used in practical application is match (see “How to Set the Probe Attenuation
4. There is waveform displayed, but it is not stable.
z Check whether the Source item in the TRIG MODE menu is in conformity with the signal channel used in the practical application. z Check on the trigger Type item: The common signal chooses the Edge trigger mode for Type and the video signal the Video. If Alternate trigger is selected, both of the channel 1 and channel 2 trigger levels should be adjusted to the proper position. Only if a proper trigger mode is applied, the waveform can be displayed steadily. z Try to change the trigger coupling into the high frequency suppress and the low frequency suppress to smooth the high frequency or low frequency noise triggered by the interference.
5. No Display Responses to the Push-down of Run/Stop.
Check whether Normal or Signal is chosen for Polarity in the TRIG MODE menu and the trigger level exceeds the waveform range.
If it is, make the trigger level is centered in the screen or set the trigger mode as Auto.
In addition, with the Autoset button pressed, the setting above can be completed automatically.
User Manual of Smart Digital Storage Oscilloscope 80
7. F.A.Q
6. After the Average value sampling is set in the Acqu Mode (see “How to Implement
Sampling Setup” on P42 ), or the longer duration is set in the Persist in Display (see
“Persist” on P46), the display rate is slowed down.
It is a normal phenomenon.
81 User Manual of Smart Digital Storage Oscilloscope
advertisement
Related manuals
advertisement
Table of contents
- 11
- 12 Introduction to the Structure of the Oscilloscope
- 12 Front panel
- 13 Left side panel
- 13 Right side panel
- 14 Rear Panel
- 15 Control (key and knob) area
- 16 User interface introduction
- 18 How to implement the General Inspection
- 19 How to implement the Function Inspection
- 20 How to Implement the Probe Compensation
- 20 How to Set the Probe Attenuation Coefficient
- 21 How to Use the Probe Safely
- 22 How to Implement Auto-calibration
- 22 Introduction to the Vertical System
- 23 Introduction to the Horizontal System
- 24 Introduction to the Trigger System
- 26 5. Advanced User Guidebook
- 27 How to Set the Vertical System
- 31 Implementation of Mathematical Manipulation Function
- 33 Using FFT function
- 37 Application of VERTICAL POSITION and VOLTS/DIV Knobs
- 37 How to Set the Horizontal System
- 40 How to set the Trigger System
- 40 Single trigger
- 44 Alternate trigger
- 48 How to Operate the Function Menu
- 48 How to Implement Sampling Setup
- 50 How to Set the Display System
- 55 How to Save and Recall a Waveform
- 57 How to Record/Playback Waveforms
- 60 How to Implement the Auxiliary System Function Setting
- 64 How to Measure Automatically
- 68 How to measure with cursors
- 73 How to use Autoscale
- 75 How to Use Executive Buttons
- 77 6. Demonstration
- 77 Example 1: Measurement of Simple Signals
- 78 Example 2: Gain of the Amplifier in the Metering Circuit
- 79 Example 3: Capture the Single Signal
- 81 Example 4: Analyze the Details of a Signal
- 83 Example 5: Application of X-Y Function
- 84 Example 6: Video Signal Trigger
- 86 7. F.A.Q
- 88 8. Technical Specifications
- 91
- 92 General Technical Specifications
- 93 9. Appendix
- 93 Appendix A: Enclosure
- 93 Appendix B: Maintenance, Cleaning and Repairing
- 94 Appendix C: Battery Using Guide