12
FUSES
This instrument contains four fuses. All are accessible from the rear-panel. Two protect the AC prime power input, and two protect the internal DC power supplies. The locations of the fuses on the rear panel are shown in the figure below:
Fuses #1 and #2
(AC fuses)
Fuse #4
(DC fuse)
Fuse #3
(DC fuse)
AC FUSE REPLACEMENT
To physically access the AC fuses, the power cord must be detached from the rear panel of the instrument. The fuse drawer may then be extracted using a small flat-head screwdriver, as shown below:
Pry out the fuse drawer using a screwdriver.
Fuse
Drawer
DC FUSE REPLACEMENT
The DC fuses may be replaced by inserting the tip of a flat-head screwdriver into the fuse holder slot, and rotating the slot counter-clockwise. The fuse and its carrier will then pop out.
13
FUSE RATINGS
The following table lists the required fuses:
Fuses
#1, #2 (AC)
#3 (DC)
#4 (DC)
Nominal
Mains
Voltage
115 V
230 V
N/A
N/A
Rating
0.8A, 250V,
Time-Delay
0.5A, 250V,
Time-Delay
2.0A, 250V,
Time-Delay
1.6A, 250V,
Time-Delay
Case Size
Recommended Replacement Part
Littelfuse Part Digi-Key Stock
Number Number
5×20 mm 0218.800HXP
F2418-ND
5×20 mm
5×20 mm
5×20 mm
0218.500HXP
0218002.HXP
021801.6HXP
F2416-ND
F2420-ND
F2424-ND
The recommended fuse manufacturer is Littelfuse (http://www.littelfuse.com).
Replacement fuses may be easily obtained from Digi-Key (http://www.digikey.com) and other distributors.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
advertisement
Table of contents
- 2 WARRANTY
- 2 TECHNICAL SUPPORT
- 3 TABLE OF CONTENTS
- 5 INTRODUCTION
- 5 HIGH-VOLTAGE PRECAUTIONS
- 6 SPECIFICATIONS
- 7 REGULATORY NOTES
- 7 FCC PART 18
- 7 EC DECLARATION OF CONFORMITY
- 8 DIRECTIVE 2002/95/EC (RoHS)
- 8 DIRECTIVE 2002/96/EC (WEEE)
- 9 INSTALLATION
- 9 VISUAL CHECK
- 9 POWER RATINGS
- 9 CONNECTION TO THE POWER SUPPLY
- 10 PROTECTION FROM ELECTRIC SHOCK
- 11 ENVIRONMENTAL CONDITIONS
- 12 FUSES
- 12 AC FUSE REPLACEMENT
- 13 DC FUSE REPLACEMENT
- 13 FUSE RATINGS
- 14 FRONT PANEL CONTROLS
- 16 REAR PANEL CONTROLS
- 17 GENERAL INFORMATION
- 17 BASIC CONTROL
- 17 CABLE LENGTHS
- 18 OPERATIONAL CHECK
- 20 MECHANICAL INFORMATION
- 20 TOP COVER REMOVAL
- 20 RACK MOUNTING
- 20 ELECTROMAGNETIC INTERFERENCE
- 21 MAINTENANCE
- 21 REGULAR MAINTENANCE
- 21 CLEANING
- 22 WIRING DIAGRAMS
- 22 WIRING OF AC POWER, STYLE 1
- 23 WIRING OF AC POWER, STYLE 2
- 24 PCB 158N - LOW VOLTAGE POWER SUPPLY, 1/3
- 25 PCB 158N - LOW VOLTAGE POWER SUPPLY, 2/3
- 26 PCB 158N - LOW VOLTAGE POWER SUPPLY, 3/3
- 27 PCB 168B - HIGH VOLTAGE DC POWER SUPPLY
- 28 MAIN WIRING
- 29 PERFORMANCE CHECK SHEET